B112LP

B112LP

  • 厂商:

    SYSTEMSENSOR

  • 封装:

  • 描述:

    B112LP - Plug-in Detector Base - Systemsensor advanced ideas.

  • 数据手册
  • 价格&库存
B112LP 数据手册
INSTALLATION AND MAINTENANCE INSTRUCTIONS B112LP Plug-in Detector Base For use with the following smoke detectors: IN US: 1151, 2151 IN CANADA: 1151A, 2151A IN EUROPE: 1151E, 2151E Specifications Base Diameter: Base Height: Weight: Mounting: 3825 Ohio Avenue St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 6.2 inches (157 mm) 0.95 inches (24 mm) 0.3 lb. (137 g) 4-inch square box with or without plaster ring. Min. depth–1.5 inches 3-1/2-inch octagon box. Min. depth–1.5 inches Operating Temperature Range: 0° to 49°C (32° to 120°F) Operating Humidity Range: 10% to 93% Relative Humidity, Noncondensing Electrical Ratings - includes base and detector System Voltage: 24 VDC Maximum Ripple Voltage: 4 Volts peak-to-peak Start-Up Capacitance: 0.02µF Maximum Standby Ratings: 20 VDC Minimum 29 VDC Maximum 120 µA Maximum Alarm Ratings: 17 mA Minimum 36 mA Maximum Reset Voltage: 1.4 VDC Minimum Reset Time: 0.3 Seconds Maximum (The optional RA400Z operates within specified detector alarm currents.) Start-up Time: 34.0 Seconds Maximum Relay Contact Ratings: Resistive or Inductive (60% Power Factor) Form A: 2.0 A @ 30 VAC/DC Form C: 2.0 A @ 30 VAC/DC 0.6 A @ 110 VDC 1.0 A @ 125 VAC Before Installing Please thoroughly read the System Sensor manual I56-407, Guide for Proper Use of System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. Copies of this manual are available at no charge from System Sensor. (For installation in Canada, refer to CAN/ULC-S524, Standard for the Installation of Fire Alarm Systems and CEC Part 1, Sec. 32.) NOTICE: This manual should be left with the owner/user of this equipment. IMPORTANT: The detector used with this base must be tested and maintained regularly following NFPA 72 requirements. The detector used with this base should be cleaned at least once a year. General Description The Model B112LP detector base is designed for use with System Sensor model 2151 photoelectronic and 1151 ionization detector heads. This four-wire base is equipped with screw terminals for the connection of power, ground, and an optional remote annunciator. Mounting The detector base mounts directly to 3-1/2 inch and 4-inch octagon boxes and 4-inch square boxes, with or without plaster rings. To mount the base, remove the decorative ring by rotating it in either direction to unhook the snaps before separating the ring from the base. Use the screws supplied with the junction box to attach the base to the box through the appropriate slots in the base (see Figure 1). Position the decorative ring around the base and rotate it in either direction until the ring snaps into place. D150-03-00 1 I56-597-03R Installation Guidelines NOTE: Refer to the releasing device manufacturer’s instructions for connection instructions. Allowable loop resistance is an important specification for control panels as well as for smoke detectors and their bases. The alarm system cannot be expected to operate correctly if system components have incompatible allowable loop resistances. Therefore, before beginning installation, refer to the control panel manufacturer’s loop resistance specification to ensure that it is listed as compatible with the System Sensor base and smoke detector being installed. All wiring must be installed in compliance with the National Electrical Code, all applicable local codes and any special requirements of the authority having jurisdiction, using the proper wire size. The conductors used to connect smoke detectors to control panels and accessory devices should be color-coded to reduce the likelihood of wiring errors. Improper connections can prevent a system from responding properly in the event of a fire. Wiring For signal wiring (the wiring between interconnected detectors), it is recommended that the wire be no smaller than AWG 18. However, the screws and clamping plate in the base can accommodate wire sizes up to AWG 12. The use of twisted pair wiring for the power (+ and -) loop is recommended to minimize the effects of electrical interference. NOTE: To ensure that electrical connections are supervised, DO NOT loop wires under terminals 2, 3, and 5 –break the wire at each terminal. To make electrical connections, strip approximately 3/8" (1 cm) insulation from the end of each wire. Slide the wires under the clamp plate and tighten the terminal screw. If the base is being installed in a zoned system, check the zone wiring before installing the smoke detector head. The built-in shorting spring makes it convenient to do this. After the detector base is wired and attached to the electrical box, position the shorting spring against terminal 3. Use the slot in the retaining clip to hold the spring against the terminal, as shown in Figure 1. This shorts the negative-in and negative-out leads so that loop wiring can be tested for continuity. The shorting spring in the base will disengage automatically when the detector head is removed from the base. DO NOT remove the shorting spring since it reengages as the detector head is turned into the base, completing the circuit. D150-03-00 2 Figure 1. Mounting base to box: SNAP ON DECORATIVE RING SCREWS (NOT SUPPLIED) SHORTING SPRING DETECTOR BASE BOX (NOT SUPPLIED) A78-1175-01 Tamper-resistance Feature NOTE: DO NOT use the tamper-resistance feature if the System Sensor XR2 Removal Tool will be used to remove detectors from the base. This detector base can be made tamper resistant so the detector cannot be removed without the use of a tool. To make the base tamper-resistant, break off the smaller tab at the scribed line on the tamper-resistance tab, on the detector mounting bracket (see Figure 3A), before installing the detector. To remove the detector from the base after it has been made tamper resistant, remove the decorative ring by rotating it in either direction and pulling it away from the base. Then, insert a small screwdriver into the notch, as indicated in figure 3B, and press the plastic lever toward the mounting surface before rotating the detector counterclockwise for removal. I56-597-03R ALARM RELAY AUXILIARY CONTACTS N.O. N.C. C. 12 13 14 (2.8 VDC) (+) (—) 1 4 REMOTE ANNUNCIATOR OUTPUT 3 (+OUT) ALARM RELAY AUXILIARY CONTACTS N.O. N.C. C. 12 13 14 (2.8 VDC) (+) (—) 1 4 REMOTE ANNUNCIATOR OUTPUT 3 (+OUT) NOTE: Schematic Shown for Reference ALARM RELAY (+IN) 2 (+) DETECTOR POWER LOOP (–) (IN) 10 ALARM RELAY (+IN) 2 EOL RELAY (+) SPORTING SPRING 5 (–IN, –OUT) SPORTING SPRING 5 (–IN, –OUT) (–) (OUT) 11 (IN) 10 (OUT) 11 ALARM INITIATION LOOP ALARM RELAY ALARM RELAY 8 (IN) FCI CONTROL PANEL 9 (OUT) 8 (IN) 9 (OUT) EOL RESISTOR FIRST DETECTOR IN LOOP FIRST DETECTOR IN LOOP Figure 2. Typical wiring diagram: POWER LOOP + — UL LISTED 4-WIRE CONTROL PANEL REMOTE ANNUNCIATOR — REMOTE ANNUNCIATOR 3 2 + EOL RELAY + + 4 14 13 12 5 11 10 RELEASING DEVICE (OPTIONAL) 2 3 4 14 13 12 5 11 10 — POWER LOOP — 1 89 1 89 RELEASING DEVICE (OPTIONAL) ALARM CIRCUIT Figure 3A. Activating the tamper-resistance feature: BREAK TAB AT DOTTED LINE BY TWISTING TOWARD CENTER OF BASE. Figure 3B. Removing detector head from base: USE SMALL-BLADED SCREWDRIVER TO PUSH PLASTIC LEVER IN DIRECTION OF ARROW. PLASTIC LEVER D150-03-00 3 EOL I56-597-03R Please refer to insert for the Limitations of Fire Alarm Systems Three-Year Limited Warranty System Sensor warrants its enclosed smoke detector base to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for this smoke detector base. No agent, representative, dealer, or employee of the Company has the authority to increase or alter the obligations or limitations of this Warranty. The Company’s obligation of this Warranty shall be limited to the repair or replacement of any part of the smoke detector base which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: System Sensor, Repair Department, RA #__________, 3825 Ohio Avenue, St. D150-03-00 4 Charles, IL 60174. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to repair or replace units which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company’s negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. I56-597-03R ©2001 System Sensor
B112LP 价格&库存

很抱歉,暂时无法提供与“B112LP”相匹配的价格&库存,您可以联系我们找货

免费人工找货