0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EPS40-2

EPS40-2

  • 厂商:

    SYSTEMSENSOR

  • 封装:

  • 描述:

    EPS40-2 - Supervisory Pressure Switches - Systemsensor advanced ideas.

  • 数据手册
  • 价格&库存
EPS40-2 数据手册
EPS40-1 AND EPS40-2 Supervisory Pressure Switches System Sensor EPS40 Series switches are designed for use in dry pipe systems or pressure tanks and water pressure supplies of automatic water control valves. Features • Sensitivity adjustment wheel, no special tools required • Reinforced diaphragm resists pressure spikes • Two conduit entrances • Both one- and two-switch models available Agency Listings The EPS40-1 has a single SPDT switch while the EPS40-2 model contains two SPDT switches. The EPS40 Series features field adjustable pressure sensitivity to provide an alarm response between 10 and 100 psi. All models are factory set for use in a nominal 40 psi system. The EPS40-1 is factory set to respond at 30 psi at decreasing pressure while the EPS40-2 is factory set to respond at 50 psi on rising pressure and 30 psi at decreasing pressure. The pressure adjustment wheel requires no special tools and does not affect switch synchronization on the EPS40-2. The EPS40-1 and EPS40-2 supervisory pressure switches are NEMA 4 rated. 118f/01 S739 0X0A7.AY CS169 VdS G4020028 7770-1209:147 167-93-E Specifications, EPS40-1 and EPS40-2 Architectural/Engineering Specifications EPS40-1 (SPDT), EPS40-2 (2/SPDT) Model shall be an EPS40-1 or EPS40-2 pressure type waterflow switch as manufactured by System Sensor of St. Charles, IL. They shall be installed on the sprinkler system with connection as shown on the drawings and/or as specified herein. Pressure switches shall be of the bellows-activated type. Switches shall have a maximum service pressure rating of 250 psi and shall be adjustable from 10 – 100 psi. There shall be one (1) or two (2) SPDT contacts rated at 10.0 Amp @ 125/250 VAC and 2.5 Amp @ 6/12/24 VDC. The contractor shall furnish and install, where indicated on the plans, pressure switches according to appropriate NFPA standards. Switches shall be provided with a ½˝ NPT male pressure connection to be connected into the air supply line on the system side of any shut-off valve. Switches shall provide 1 knockout type and 1 open hole for ½˝ conduit fitting attachment and a ground screw provision for electrical grounding. The switch enclosure shall be weatherproof and carry a UL 4x/NEMA 4 rating when used with proper electrical fittings and conduit. The cover shall incorporate tamper-resistant screws. The unit shall be listed by Underwriters Laboratories, Inc., the California State Fire Marshal, MEA, CSFM, LPCB, VdS and approved by Factory Mutual. Specifications, EPS40-1 and EPS40-2 (continued) Physical/Operating Specifications Maximum Operating 250 psi Pressure Maximum Adjustment 10 to 100 psi Pressure Range Differential Approximately 3 psi @ 10 psi, 6 psi @ 100 psi Factory Setting EPS40-1 operates at decreasing pressure at 30 psi EPS40-2 operates at increasing pressure at 50 psi and decreasing pressure at 30 psi Switch Contact Ratings EPS10-1: One set SPDT (Form C) EPS10-2: Two sets SPDT (Form C) 10.0 A, ½ HP @ 125/250 VAC 2.5 A @ 6/12/24 VDC Pressure Connection ½˝ NPT male Dimensions 5.12˝ H × 3.325˝ W × 4.250˝ L (13.0 cm × 8.4 cm × 10.8 cm) Operating Temperature Range Cover Tamper Switch Enclosure Shipping Weight Indoor or outdoor use: –40°F to 160°F (–40°C to 71°C) UL Models: Optional P/N 546-8000 ULC Models: Factory Installed Rated UL 4x, NEMA 4 for indoor or outdoor use 1.2 lbs. (.54 Kg) Service Use Warranty Automatic Sprinkler: NFPA 13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA 72 3 years Typical Sprinkler Applications EPS40 WIRE TO SUPERVISORY CIRCUIT OF FIRE ALARM CONTROL PANEL TO SPRINKLER SYSTEM INSTALL BLEEDER VALVE FOR TESTING CHECK VALVE EPS40 WIRE TO ALARM INDICATING CIRCUIT OF FIRE ALARM CONTROL PANEL CHECK VALVE AIR LINE SHUT-OFF VALVE DRY PIPE VALVE WATER MOTOR GONG OS & Y VALVE WATER BY-PASS TEST VALVE LOCAL ALARM SHUT OFF VALVE DRY SYSTEM Electrical Connections MODELS EPS40-1 SWITCH AT 40 P.S.I. (NORMAL) B COM A SWITCH AT 30 P.S.I. (LOW TRIP PT.) B COM A MODELS EPS40-2 SWITCHES AT 30 P.S.I. (LOW TRIP PT.) B B COM COM A A SW1 SW2 SWITCHES AT 40 P.S.I. (NORMAL) B COM A SW1 SWITCH 1 B COM A SW2 Pressure Switch Basic Dimensions 4 41/ ″ GROUND SCREW (GREEN) CO M A SWITCH #2 B HEX ADJUSTMENT SCREW 51/8″ LOCKING SCREW SWITCHES AT 50 P.S.I. (HIGH TRIP PT.) B COM A SW1 B COM A SW2 MAIN ADJUSTMENT WHEEL 1 2″ / NPT Ordering Information Part No. EPS40-1 EPS40-2 EPSA40-1 EPSA40-2 Replacement Parts S07-66-XX WFDW 546-8000 Description Low Pressure Supervisory Switch, One SPDT, 10–100 PSI High/Low Pressure Supervisory Switch, Two SPDT, 10–100 PSI Low Pressure Supervisory Switch, One SPDT, 10–100 PSI (ULC Model) High/Low Pressure Supervisory Switch, Two SPDT, 10–100 PSI (ULC Model) Replacement Tamper Screws for Cover of EPS Replacement Tamper Proof Wrench for Cover of EPS Cover Tamper Switch for EPS Series 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2006 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0177-010 • 9/06 • #1676
EPS40-2 价格&库存

很抱歉,暂时无法提供与“EPS40-2”相匹配的价格&库存,您可以联系我们找货

免费人工找货