PS12/24ADA Signaling Strobe and Sounder
A Division of Pittway 3825 Ohio Avenue, St. Charles, IL 60174 1-800-SENSOR2 (736-7672), Fax 630-377-6495 http://www.systemsensor.com
Models Available
PS2415ADA PS241575ADA PS2475ADA PS24110ADA PS1215ADA PS121575ADA
Features
• • • • • Low combined strobe/horn current draw from 90 mA New “Euro-Style” appearance Easily fits into single gang backbox Fits double gang backbox with optional semi-flush plate Multiple Light intensities –24 VDC: 15, 15/75, 75 or 110 cd models –12 VDC: 15 or 15/75 cd models • Available in Red or White • No measurable in-rush in excess of peak current • Wall mount only System Sensor PS12/24ADA Series integrated sounder/ strobes comply with the Americans with Disabilities Act (ADA) and the demanding requirements of the new Standard UL 1971 for the Hearing Impaired. The 15/75 version is UL 1971 listed at 15 cd. To insure compliance with ADA and UL 1971, use the System Sensor 75 candela models for non-sleeping areas, and 110 candela models for sleeping areas. Available in red or white at 12 or 24 VDC, the PS12/24ADA series of signaling strobes can be mounted directly to a standard 2″ backbox or 4″ backbox with the optional semi-flush plate.
Specifications
Input terminals: Shipping Weight: PS12/24ADA Series Strobes: Operating Temperature Range: Mounting: Surface: Semi-flush: 18 – 12 AWG Dimensions:
4″ 3″
13 oz. (369g) 32° F to 120° F (0° C to 49° C) 2″ × 4″ × 11/4″ standard single gang box 2″ × 4″ × 11/2″ standard single gang box
7″
31/2″
1/ ″ 2
APPROVED
© System Sensor 8/96
This document is not intended to be used for installation purposes.
A05-250-02
General Description
All PS12/24ADA Series integrated sounder/strobes are suitable for primary signaling in public mode life safety applications. The sounder/strobes can be connected to the alarm indicating circuit of a UL listed fire alarm control panel. They are compatible with DC line supervision. Panels may have full-wave rectified, unfiltered power supplies. The sounder/strobes are available for either 24VDC operation, with 15, 15/75, 75, or 110 cd light intensity, or for 12VDC operation with 15 or 15/75 cd light intensity. They feature low current draw with no measurable in-rush in excess of peak current. The sounder/strobe is intended for wall mounting only to a 2″ electrical backbox. Mounting to a 4″ square electrical backbox can be done with the addition of the PS-FP accessory mounting plate.
Electrical Ratings – Strobe/Mini Horn
Model Red PS2415ADA PS241575ADA PS2475ADA PS24110ADA PS1215ADA PS121575ADA White PS2415ADAW PS241575ADAW PS2475ADAW PS24110ADAW PS1215ADAW PS121575ADAW Supply Voltage Range 20–30VDC 20–30VDC 20–30VDC 20–30VDC 10.5–17VDC 10.5–17VDC Peak Operating Current (mA) 180 220 400 500 380 560 In-rush Current in Excess of Peak Operating Current (mA) 0 0 0 0 0 0 Average Operating Current from Regulated Supply (mA) 90 108 185 225 185 240 Average Operating Current from Full Wave Rectified, Unfiltered Supply (mArms)* 105 135 215 260 212 285
* For additional information, see installation manual D900-08-00. Actual 12 volt operating voltage cannot be less than 8.5 VDC or greater than 18.7 VDC; actual 24 volt operating voltage cannot be less than 16 VDC or greater than 33 VDC.
Engineering Specifications
Sounder/Strobe shall be a System Sensor Model ______ listed to Standard UL 1971 for the Hearing Impaired and shall be approved for Fire Protective Service. Sounder/ Strobe shall be wired as a Primary Signaling Notification appliance. Sounder/strobe shall also comply with the Americans with Disabilities Act requirements for visible signaling appliances. Sounder/Strobe shall operate on 12 or 24VDC from a regulated DC supply or full-wave rectified, unfiltered supply. The sounder/strobe shall be powered from a non-coded power supply. Sounder/Strobe shall have no measurable in-rush current in excess of operating peak current. Visual signaling devices are to be installed in all non-sleeping/corridor and sleeping areas per plans and specifications. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. All sounder/strobes shall be capable of semi-flush wall mounting to a standard 2″ × 4″ × 11/2″ backbox, without a separate mounting plate or to a 4″ × 4″ × 11/2″ backbox with a separate mounting plate.
Standard Light Distribution
Vertical Dispersion
ZERO AXIS Degree 0 5-30 5 35 40 45 10 50 55 15 60 65 70 20 75 80 85 25 90 0 Percent of Rating 100 90 65 46 34 27 22 18 16 15 13 12 12 12
Horizontal Dispersion
0˚
Degree 0 5-25 30-45 50 55 60 65 70 75 80 85 –90˚ 90 Percent of Rating 100 90 75 55 45 40 35 35 30 30 25 25
45˚
–45˚
W A L L
LIGHT 90˚ WALL
90˚ 85 80 75 70 65 60 55
50
45 40 FLOOR
35
30
A polar light distribution in both horizontal and vertical directions is mandated for the strobes by the Standard UL 1971 for the Hearing Impaired, with specific minimum intensity percentages as shown in the graphs above. With its specially designed lens/reflector system, the PS12/24ADA Strobe Retrofit Plate Series meets or exceeds these requirements at all angles.
Page 2
A05-250-02
Wiring
From Control Panel or Previous Device
From Control Panel or Previous Device
To Next Device or EOL
Cut and Remove for Independent Operation Blk Red
To Next Device
Note: Remove paper shield; cut and remove red and black wires between the horn and strobe.
Mounting
Sounder/Strobe 2 Inch Box
4 Inch Box with PS-FP
2 Inch Box with PS-FP
4 Inch Box with Plaster Ring and PS-FP
Page 3
A05-250-02
Ordering Information
Signaling Strobe – UL 1971 Compliant Red White Product PS2415ADA PS2415ADAW Signaling Strobe/Sounder PS241575ADA PS241575ADAW Signaling Strobe/Sounder PS2475ADA PS2475ADAW Signaling Strobe/Sounder PS24110ADA PS24110ADAW Signaling Strobe/Sounder PS1215ADA PS1215ADAW Signaling Strobe/Sounder PS121575ADA PS121575ADAW Signaling Strobe/Sounder PS-FP PS-FPW Semi-Flush Mounting Plate *dBA measured in anechoic room at 10 feet. **Measured to be 75 cd at 0˚ viewing angle (See Light Distribution Graph). Operating Voltage 24 VDC 24 VDC 24 VDC 24 VDC 12 VDC 12 VDC Strobe and Sounder Current Combined (Average mA) 90 108 185 225 185 240 Candela 15 15/75** 75 110 15 15/75** Peak (dBA)* 90 dBA 90 dBA 90 dBA 90 dBA 83 dBA 83 dBA
How to Order
PS1215ADAW
W = White Strobe 15 = 15 cd, UL 1971 Strobe 1575 = 15 cd, UL 1971 75 = 75 cd, UL 1971 Strobe 110 = 110 cd, UL 1971 Strobe 12 = 12 Volt 24 = 24 Volt SS = Signal Strobe PS = Mini-Alert Sounder/Strobe RP = Retrofit Plate MASS = Multi-Alert Sounder/Strobe MAEH = Multi-Alert Sounder/Strobe with Electromechanical Tone V4R = 400 Series Speaker, Red SP1R = SP101 Series Speaker (Strobe), Red SP1W = SP101 Series Speaker (Strobe), White
System Sensor Worldwide Distribution
In Canada: System Sensor Canada 6581 Kitimat Road, Unit #7 Mississauga, Ontario Canada L5N 3T5 Telephone: 905-812-0767 Fax: 905-812-0771 Page 4 In the United Kingdom: System Sensor Europe, Ltd. Horsham Gates III, North St. Horsham, West Sussex RH13 5PJ, United Kingdom Telephone: 44-1403-276500 Fax: 44-1403-276501 In India: System Sensor India A-204 Maheshwari Nagar Orkay Mills Lane Andheri East, Mumbai 400093 Telefax: 91-022-8202564 In the Far East: System Sensor Pittway Far East, Ltd. Suite 706, World Shipping Centre 7 Canton Road Tsimshatsui, Kowloon, Hong Kong Telephone: 852-2730-9090 Fax: 852-2736-6580 A05-250-02
很抱歉,暂时无法提供与“PS241575ADA”相匹配的价格&库存,您可以联系我们找货
免费人工找货