0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
S1224MCP

S1224MCP

  • 厂商:

    SYSTEMSENSOR

  • 封装:

  • 描述:

    S1224MCP - Selectable Output Strobe and Horn Strobes - Systemsensor advanced ideas.

  • 数据手册
  • 价格&库存
S1224MCP 数据手册
Audible/Visible NotificAtioN Selectable Output Strobe and Horn/Strobes Models Available Strobes Red S1224MC S1224MCP S1224MCK S1224MCSP Horn/Strobes Red P1224MC P1224MCP P1224MCK P1224MCSP Horns Red H12/24 H12/24K Product Overview Operates on either 12V or 24V Widest range of candela options: 12V: 15 and 15/75 candela 24V: 15, 15/75, 30, 75, 110 candela Easy candela selection Lower current draw Easy DIP switch selection for horn options Easy mounting with QuickClick™ Synchronizable with MDL Sync•Circuit™ module Meets UL1971, NFPA72, and ADA signaling requirements All strobe and horn/strobe models incorporate a new patented voltage booster design that has a more consistent flash bulb voltage over the range of candela selections. The benefit to the customer is a high quality strobe device. White S1224MCW S1224MCPW P1224MC Horn/Strobe White P1224MCW P1224MCPW White H12/24W S1224MC Strobe SpectrAlert® Selectable Output Horns, Strobes, and Horn/Strobes offer enhanced features that include the widest range of candela options available and the capability to recognize and self-adjust for either 12 or 24 volt operation. With an overall feature set that combines performance, installation ease, flexibility, and a consistent, aesthetically pleasing appearance, the SpectrAlert Selectable Output devices provide both the innovation and efficiency synonymous with the SpectrAlert name. Performance. SpectrAlert selectable output wall-mount horns, strobes, and horn/strobes offer key performance features long associated with the SpectrAlert name. The selectable candela strobes and horn/strobes offer average current draws that are not only lower than conventional fixed-candela SpectrAlert products, but also lower than similar selectable candela products. By consuming less current, the ability to connect even more devices per loop is possible, resulting in a lower installed cost. Installation. SpectrAlert selectable output horns, strobes, and horn/strobes offer the same installation-friendly features synonymous with the SpectrAlert name, such as the option of 2- and 4-wire operation; the ability to use standard size backboxes with no encroachment into the box; and universal mounting incorporating the labor-saving QuickClick™ feature. Such labor-savings features make wire connections simple and fast, further reducing installed cost. Flexibility. SpectrAlert selectable output strobes and horn/strobes offer the broadest range of candela options. In addition, the selectable output strobes and horn/strobes can operate on either 12V or 24V, with no setting required; the device recognizes and self-adjusts to the correct current automatically. Temporal 3 or Continuous tone options continue to be available, in either an Electromechanical or 3kHz pattern. Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate the same stylish, low profile design of the conventional SpectrAlert products, for a consistent and aesthetically pleasing appearance across the entire product line. 7125-1209:222 7135-1209:223 S5512 S4011 3014150 122-02-E 126-02-E Engineering Specifications General SpectrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 4˝ × 4˝ × 11/ 2˝ back box or a single gang 2˝ × 4˝ × 17/ 8˝ back box using the universal mounting plate included with each SpectrAlert product. Also, SpectrAlert products, when used in conjunction with the accessory Sync•Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. 12 volt rated devices shall have an operating voltage range of 9–17.5 volts. 24-volt rated devices shall have an operating voltage range or 17–33 volts. SpectrAlert products shall have an operating temperature of 32° to 120°F and operate from a regulated DC or full wave rectified, unfiltered power supply. Strobe Strobe shall be a System Sensor SpectrAlert Model _______ listed to UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination Horn/Strobe shall be a System Sensor SpectrAlert Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn/ strobe models shall operate on a coded or non-coded power supply (the strobe must be powered continuously). Synchronization Module Module shall be a System Sensor Sync•Circuit _______ listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal 3. Also, the module shall silence the horns on horn/ strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting to a 411/16˝ × 411/16˝ × 21/8˝ back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply. Specifications Walk Test SpectrAlert horn/strobe and horn only work on “walk tests” with time durations of 4 seconds or greater Input Terminals 12 to 18 AWG Dimensions Strobe and horn/strobe with universal plate 5˝ × 5 5/8˝ × 2 15/16˝ Strobe and horn/strobe with small footprint plate 3 3/8˝ × 5 5/8˝ × 2 5/16˝ Horn with universal mounting plate 5˝ × 5 5/8˝ × 1 5/16˝ Horn without mounting plate 2 15/16˝ × 5 5/16˝ × 1 5/16˝ Weight, horn only 7.2 oz. Weight, strobe and horn/strobe 8.8 oz. Mounting 4˝ × 4˝ × 1 1/2˝ or 2˝ × 4˝ × 1 7/8˝ standard boxes Operating Temperature (Indoor) 32°F to 120°F (0°C to 49°C) Maximum humidity (Indoor) 95% as tested per UL464 Outdoor (K Series) Operating Temperature –40°F to 151°F (–40°C to 66°C) Outdoor rating NEMA 3R (per UL 50) Voltages 12 or 24VDC and FWR1 unfiltered Operating voltage range 12V: 8–17.5V; 24V: 16–33V Operating voltage range (with Sync•Circuit module, MDL)2 12V: 9–17.5V; 24V: 17–33V U.S. Patent Numbers 5,593,569 5,914,665 6,049,446 Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-var ying power source that is used on some power supply and panel outputs. 2. The MDL causes a one-volt voltage drop in the notification appliance circuit. Table 1-A: SpectrAlert Strobe UL Max. Current Draw Candela Setting 15 15/75 30 75 110 FWR Operating Current–Strobe (mA RMS) 8-17.5V 16-33V 112 64 135 74 93 158 208 DC Operating Current–Strobe (mA RMS) 8-17.5V 16-33V 127 59 127 69 90 160 209 Explanation of Published Voltage, Current, and SPL Specifications In May 2004 Underwriters Laboratories changed standard UL 1971 to require that operating current measuremments are made using RMS (root mean square) instead of peak or average values. RMS measurements more accurately predict the power consumption of a device since they take into account the entire current draw profile including surge, repetitive surge, and peak values. The published RMS current is the maximum operating current of that device within its operating voltage range. This current maximum may or Table 1-B: Horn UL Max. Current Draw Measurements (mA RMS) may not occur at the endpoints of the voltage range. DC FWR 16-33V 23 33 53 57 37 32 49 56 8-17.5V 13 13 20 21 19 18 46 42 16-33V 23 23 44 40 29 33 49 58 Selectable Horn Tones Temporal Low Volume High Volume NonTemporal Low Volume High Volume Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted 8-17.5V 15 15 36 43 16 16 38 44 Similarly, UL tests the audibility of devices in accordance with UL 464 by measuring them across the operating voltage range to determine the minimum sound pressure level produced at any particular setting. During May 2004, UL also changed the way they list the voltage range of a device. All 12V products will be listed between 8 – 17.5V and all 24V products will be listed between 16 – 33V. Those devices are considered “regulated”. Any product that does not operate within these ranges will be listed as a “special application” with its operating voltage specified on the device. Notes Table 1-C: 12VDC Horn/Strobe UL Max. Current Draw Measurements (mA RMS) Temporal Low Volume Candela Setting 15 15/75 Electromechanical 111 127 3000 Hz 111 127 Non-Temporal 15 15/75 113 128 112 128 114 130 115 134 High Volume Electromechanical 112 126 3000 Hz 112 129 1. urrent draw for strobe-only products is shown in Table 1-A. C 2. urrent draw for horn-only products is shown in Table 1-B. C 3. 2VDC 2-wire horn/strobe current is shown in Table 1-C. 1 4. 4VDC 2-wire horn/strobe current draw is shown in Table 2 1-D. 5. urrent draw for other horn/strobe power supplies can be C calculated by adding the strobe current in Table 1-A to the horn current in Table 1-B from the chosen settings. Table 1-D: 24VDC Horn/Strobe UL Max. Current Draw Measurements (mA RMS) Temporal Low Volume Candela Setting 15 15/75 30 75 110 Electromechanical 71 86 99 166 209 3000 Hz 70 85 98 166 209 Non-Temporal 15 15/75 30 75 110 74 86 101 167 213 74 88 101 167 213 79 93 107 173 218 82 96 110 176 222 High Volume Electromechanical 73 87 100 167 210 3000 Hz 75 88 100 170 213 SpectrAlert Strobe Candela Selections For strobe candela selection, adjust slide switch located on the rear of the product while watching the viewing window on the side of the reflector. Permissible Candela Settings Candela Setting 15 15/75 30 75 Operating Voltage 12V OK OK 24V OK OK OK OK OK Viewing Window A0133-00 110 SpectrAlert Horn Sound Measurements (dBA) Typical weatherproof mounting with universal plate 16-33V 75 75 80 81 79 79 84 86 Gasket Conduit Entrance WBB Plate #8-36 x 1/2˝ Flat Head Screw (4 total) Selectable Horn Tones Temporal Low Volume High Volume NonTemporal Low Volume High Volume Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted 8-17.5V 67 68 71 72 71 72 76 77 DIP Switch Operation on P1224MC OFF Low Temporal Electromech. ON Factory Default High Non-Temporal 3000Hz Base (rear) A0110-00 Slot Paper Liner For Plate Gasket Locking Rib A0135-02 DIP Switch SpectrAlert Ordering Information Model P1224MC P1224MCW P1224MCP P1224MCPW P1224MCK P1224MCSP S1224MC S1224MCW S1224MCP S1224MCPW S1224MCK S1224MCSP Description Selectable Output Horn/Strobe, 12/24 volt, red Selectable Output Horn/Strobe, 12/24 volt, white Selectable Output Horn/Strobe, 12/24 volt, red, plain housing Selectable Output Horn/Strobe, 12/24 volt, white, plain housing Selectable Output Horn/Strobe, 12/24 volt, red, outdoor Selectable Output Horn/Strobe, 12/24 volt, red, “FUEGO” housing Selectable Output Strobe, 12/24 volt, red Selectable Output Strobe, 12/24 volt, white Selectable Output Strobe, 12/24 volt, red, plain housing Selectable Output Strobe, 12/24 volt, white, plain housing Selectable Output Strobe, 12/24 volt, red, outdoor Selectable Output Strobe, 12/24 volt, red, “FUEGO” housing Model H12/24 H12/24W H12/24K Accessories MDL MDLW MDLWA S-MP S-MPW BBS BBSW D-MP D-MPW WBB Description Horn, 12/24 volt, red Horn, 12/24 volt, white Horn, 12/24 volt, red, outdoor Sync•Circuit Module, red Sync•Circuit Module, white Sync•Circuit Module, white, Canadian model Small Footprint Mounting Plate, red, for singlegang back box Small Footprint Mounting Plate, white, for singlegang back box Sur face Mount Back Box Skir t, red Sur face Mount Back Box Skir t, white Universal Mounting Plate (replacement), red Universal Mounting Plate (replacement), white Weatherproof Back Box Notes All of these SpectrAlert products are designed for wall mount only. All outdoor models must use weatherproof back box model WBB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn/ strobes are recommended for 20′ × 20′ rooms or less. System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377-6495 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.276500 Fx: 44.1403.276501 System Sensor in China Ph: 86.29.8832.0119 Fx: 86.29.8832.5119 System Sensor in Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 System Sensor – Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor – Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor – India Ph: 91.124.237.1770 x.2700 Fx: 91.124.237.3118 System Sensor – Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 A05-0325-006•9/05•#1526 © 2005 System Sensor. The company reserves the right to change product specifications without notice.
S1224MCP 价格&库存

很抱歉,暂时无法提供与“S1224MCP”相匹配的价格&库存,您可以联系我们找货

免费人工找货