0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SS24ADAS

SS24ADAS

  • 厂商:

    SYSTEMSENSOR

  • 封装:

  • 描述:

    SS24ADAS - Synchronized Strobes with SyncCircuit - Systemsensor advanced ideas.

  • 数据手册
  • 价格&库存
SS24ADAS 数据手册
SS24ADAS Synchronized Strobes with Sync•Circuit™ A Division of Pittway 3825 Ohio Avenue, St. Charles, IL 60174 1-800-SENSOR2 (736-7672), Fax 630-377-6495 http://www.systemsensor.com Models Available SS2415ADAS Strobe with Sync•Circuit SS241575ADAS Strobe with Sync•Circuit MASS2415ADAS Sounder/Strobe with Sync•Circuit MASS241575ADAS Sounder/Strobe with Sync•Circuit Features • Works on two wire circuit • No synchronization module required • Synchronized and unsynchronized strobes can be combined on the same zone in any combination • Patent pending Sync•Circuit™ • 24 VDC versions only • 15 and 15/75 cd versions available • Available with Multi-Alert™ Sounder • Constant current draw over voltage range • Stand alone strobe mounts to single gang box with MP-SF plate • ADA compliant, UL 1971 listed • Installer easy plug-in terminal strip on stand-alone strobe The SS24ADAS Series Synchronized Strobes are crystal controlled to flash at precisely one flash per second. When power is applied to an indicating circuit controlled by one controller, all SS24ADAS or MASS24ADAS series devices in that zone will flash simultaneously. No synchronizing modules or coded supplies are necessary. The strobes can be used in any combination with other System Sensor ADA strobes, ADA horn/strobes, and ADA speaker/ strobes. The unique lens/reflector design maintains the UL 1971 light dispersement pattern while flashing at the ADA minimum 1 flash per second. Available in red at 24 VDC, the SS24ADAS strobes can be surface mounted directly to a standard 4″ backbox or can be mounted to our semiflush plate for recessed electrical boxes. They are also available in combination with System Sensor Multi-Alert™ horns for both visible and audible signaling. Specifications Input terminals: Shipping Weight: SS-ADA Strobes: MASS-ADA Horn/Strobes: Operating Temperature Range: Mounting: Surface: Semiflush: 18 – 12 AWG 5 oz. (141g) 4″ 4″ Dimensions: TOP TOP 10.4 oz. (293g) 32° F to 120° F (0° C to 49° C) 4″ × 4″ × 11/2″ standard backbox (21/8″ recommended) 4″ × 4″ × 11/2″ standard backbox (21/8″ recommended) with MP-SF semiflush mounting plate (order separately) 4″ 23/4″ 3″ 1/4″ 4″ 33/4″ 53/32″ 111/32″ SS Series ADA MASS Series ADA APPROVED © System Sensor 8/96 This document is not intended to be used for installation purposes. A05-239-03 General Description All Series SS24ADAS strobes are suitable for primary signaling in public mode life safety applications. The strobes can be connected to the alarm indicating circuit of a UL listed fire alarm control panel. They are compatible with DC line supervision. Panels may have full-wave rectified, unfiltered power supplies. The strobes are available for 24VDC operation and can be used with the System Sensor Multi-Alert™ horn. Stand-alone strobe versions incorporate these “installer easy” features: plugin terminal strip, wiring guide, and strip gauge (on back). Semiflush mounting is available with the addition of an MP-SF accessory plate. When installed in a zone, the SS24ADAS and MASS24ADAS Series devices flash simultaneously. Note: SS24ADAS and MASS24ADAS Series devices operating in the same zone will not be synchronized if energized at different times (i.e., if more than one controller is controlling the same zone). Sound Output Selection Guide Multi-Alert Sounder – MA12/24D Available Sounds Slow Whoop 800 Hz continuous (factory setting) 800–1000 Hz Alternating 2400 Interrupted 2400 Continuous 1200 Interrupted Swept Frequency Fast Warble Clips on Tabs (ABC)1 ABC BC AC AB C B A None Current (mA) DC Regulated/FWR Unfiltered2 24V 30V 38/56 46/72 28/45 34/46 35/56 38/59 23/33 34/47 30/47 35/55 43/58 43/64 46/73 27/41 43/60 38/59 Average* 24V 92 93 92 90 94 91 92 92 Sound Output (dBA) Peak* UL (dBA) Ratings 24V 24V 100 85 99 98 98 104 101 101 100 Sound Output (dBA) Peak* 24V 100 99 98 98 104 101 101 100 85 85 85 85 82 85 85 Multi-Alert Sounder – MA12/24EH Clips on Available Sounds Tabs (ABC)1 Fast Whoop ABC 800 Hz Continuous BC 800/1000 Hz Fast Dual AC Chirp AB 2400 Hz Continuous C Bell B Laser A Electro-Mechanical None (factory setting) Current (mA) DC Regulated/FWR Unfiltered2 24V 30V 38/56 46/72 28/45 35/55 34/46 43/58 35/56 43/64 38/59 46/73 23/33 27/41 34/47 43/60 30/47 38/59 Average* 24V 92 93 92 90 94 91 92 92 UL (dBA) Ratings 24V 85 85 85 85 85 82 85 85 * dBA measured in anechoic room at 10 feet. The acoustical output shall meet the current requirements of UL Standard 464. 1. See Tone Selection diagram below for tab clip removal and storage. 2. All models can be powered using uncoded full wave rectified, unfiltered supplies. Under no circumstances can SSADAS or MASSADAS input voltage exceed 33 VDC or be less than 20 VDC. MA Sounder Tone Selection COVER SLOT FO SL R CL ID E CO IP ST VE R E OR AG TONE SELECTION TABS TAB A TAB B TAB C CLIP STORAGE CLIPS REMOVED OR ADDED TO SELECT DESIRED TONE. FOR STORING UNUSED CLIPS: SLIDE COVER BACK TO ALIGN COVER SLOT WITH CLIP STORAGE POST. USE A SMALLBLADED SCREWDRIVER TO REMOVE CLIPS Page 2 A05-239-03 Standard Light Distribution Vertical Dispersion ZERO AXIS Horizontal Dispersion Degree 0 5-30 5 35 40 45 10 50 55 15 60 65 70 20 75 80 85 25 90 0 W A L L 90˚ 85 80 75 70 65 60 55 50 45 40 FLOOR 35 30 Percent of Rating 100 90 65 46 34 27 22 18 16 15 13 12 12 12 0˚ Degree 0 5-25 30-45 50 55 60 65 70 75 80 85 –90˚ 90 Percent of Rating 100 90 75 55 45 40 35 35 30 30 25 25 45˚ –45˚ LIGHT 90˚ WALL A polar light distribution in both horizontal and vertical directions is mandated for the strobes by the Standard UL 1971 for the Hearing Impaired, with specific minimum intensity percentages as shown in the graphs above. Wiring To Next Device or EOL To Next Device – VDC – VDC STROBE IN(–) OUT(–) IN(+) OUT(+) (–)IN (–)OUT (+)IN (+)OUT or EOL + VDC From panel or previous device CAN BE SOUNDER CODED SUPPLY + VDC – VDC + VDC NONCODED SUPPLY Break off tab To Next Device or EOL From panel or previous device Note: Jumpers (included in screw-pack) must be installed as shown for tandem operation. – VDC + VDC NONCODED SUPPLY From panel or previous device Strobe Only Horn/Strobe Independent Horn/Strobe Combination Mounting MA-12/24D TO P Signal Strobe Signal Strobe Strobe Surface Mount Horn/Strobe Surface Mount MP-SF MP-SF MA-12/24D Signal Strobe Signal Strobe TO P Horn/Strobe Semiflush Mount Strobe Semiflush Mount Page 3 A05-239-03 Electrical Ratings – Strobe Only Model SS2415ADAS SS241575ADAS Supply Voltage Range 20–30VDC 20–30VDC Average Operating Current from Regulated Supply (mA) 106 195 Peak Operating Current (mA) 200 350 Operating Current from Full Wave Rectified, Unfiltered Supply (mArms)* 125 180 * For additional information, see installation manual D900-06-00; for EH models, see installation manual D900-12-00. Engineering Specifications Strobe shall be a System Sensor Model ______ listed to Standard UL 1971 for the Hearing Impaired and shall be approved for Fire Protective Service. Strobe shall be wired as a Primary Signaling Notification appliance. Strobe shall also comply with the Americans with Disabilities Act requirements for visible signaling appliances. Strobe shall operate at 24VDC from a regulated DC supply or full-wave rectified, unfiltered supply. The signaling strobe shall be powered from a non-coded power supply when powered with the horn or powered independently. Visual signaling devices are to be installed in all non-sleeping/corridor and sleeping areas (110 cd only) per plans and specifications. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Each strobe shall be designed for one flash per second over all operating conditions. All strobes shall be capable of mounting to a standard 4″ × 4″ × 11/2″ backbox, in either a surface mount or semiflush mount with separate mounting plate. Strobe shall flash synchronously with other SS24ADAS and MASS24ADAS Series devices in the same zone for a minimum of 15 minutes. Note: SS24ADAS, MASS24ADAS and MAEH24ADAS Series devices operating in the same zone will not be synchronized if energized at different times (i.e., if more than one controller is controlling the same zone). Ordering Information Models – ADA Compliant, UL 1971 Listed Product Signaling Strobes SS2415ADAS Signaling Strobe with Sync•Circuit SS241575ADAS** Signaling Strobe with Sync•Circuit Multi-Alert Sounder with Signaling Strobe MASS2415ADAS Sounder with Signaling Strobe with Sync•Circuit MASS241575ADAS** Sounder with Signaling Strobe with Sync•Circuit *Total current = strobe current + sounder current **UL 1971 listed to 15 cd. Recommended for areas 20′ × 20′ or smaller. Electromech. Tone Operating Voltage 24 VDC 24 VDC MAEH2415ADAS MAEH241575ADAS 24 VDC 24 VDC Strobe Current (Average mA) 106 195 * * Candela 15 15/75 15 15/75 How to Order SS2415ADAS Synchronizable Strobe 15 = 15 cd, UL 1971 Strobe 1575 = 15 cd UL 1971 24 Volt SS = Signal Strobe MASS = Multi-Alert Sounder/Strobe MAEH = Multi-Alert Sounder/Strobe with Electromechanical Tone System Sensor Worldwide Distribution In Canada: System Sensor Canada 6581 Kitimat Road, Unit #7 Mississauga, Ontario Canada L5N 3T5 Telephone: 905-812-0767 Fax: 905-812-0771 Page 4 In the United Kingdom: System Sensor Europe, Ltd. Horsham Gates III, North St. Horsham, West Sussex RH13 5PJ, United Kingdom Telephone: 44-1403-276500 Fax: 44-1403-276501 In India: System Sensor India A-204 Maheshwari Nagar Orkay Mills Lane Andheri East, Mumbai 400093 Telefax: 91-022-8202564 In the Far East: System Sensor Pittway Far East, Ltd. Suite 706, New T&T Centre 7 Canton Road Tsimshatsui, Kowloon, Hong Kong Telephone: 852-2730-9090 Fax: 852-2736-6580 A05-239-03
SS24ADAS 价格&库存

很抱歉,暂时无法提供与“SS24ADAS”相匹配的价格&库存,您可以联系我们找货

免费人工找货