0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
WBB

WBB

  • 厂商:

    SYSTEMSENSOR

  • 封装:

  • 描述:

    WBB - Weatherproof Back Box Accessory - Systemsensor advanced ideas.

  • 数据手册
  • 价格&库存
WBB 数据手册
INSTALLATION AND MAINTENANCE INSTRUCTIONS WBB Weatherproof Back Box Accessory Specifications Dimensions: Box: 4.33″L × 1.55″W × 4.33″H Foam gasket: 0.125″ thick, adheres to box top Conduit opening: (2) 1⁄2″ NPT, fully threaded with (2) 1⁄2″ NPT plug, (1) 7⁄8″ knockout plug Rear mounting tabs with 0.25″ diameter eyelets Top mounting holes, #8-32 × 0.50″ DP Mounting Instructions Figure 1: SpectrAlert horn, strobe, and horn/strobe (‘K’ suffix models) mounting with universal plate WBB 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 www.systemsensor.com This accessory is UL listed for use with: • H12/24K, S1224MCK, P1224MCK, and P12015K series SpectrAlert® wall horn, strobe and horn/strobe models • SSM24 and SSV120 series alarm bells Refer to specific model installation instructions for weatherproof rating, temperature operating range, indoor and outdoor application information. Figure 2: Typical SSM and SSV bell weatherproof installation GASKET WBB Plate Flat Head Screw (4 total) CONDUIT ENTRANCE Gasket Conduit Entrance Slot Paper Liner For Plate Gasket Locking Rib PAN HEAD SCREW (4 TOTAL) W0169-01 A0135-01 1. Mount back box in desired location (See Figure 1). 2. Install 1⁄2″ NPT plug into unused conduit opening. 3. For SpectrAlert models, mount plate to back box using 4 #8-32 x 1⁄2″ screws (Figure 1)supplied with product. 4. Complete field wiring. 5. Remove paper liner on plate gasket – NOTE: Perform electrical tests first, then remove liner. Paper liner must be removed from gasket before final installation. 6. Insert locking rib into slot on plate. 7. Press into plate; the SpectrAlert model will make a “click” when it has locked into place. NOTE: The weatherproof or outdoor notification appliance must be used with the System Sensor WBB back box when installed in applications requiring the appliance to be weatherproof or outdoor-listed. In such applications, using a back box other than the System Sensor WBB will void the UL designation. NOTE: All System Sensor weatherproof wall-mount horns and horn/strobes can be surface mounted or flush mounted when used with the System Sensor WBB. D770-41-00 1 1. Mount back box in desired location (See Figure 2). 2. Install 1⁄2″ NPT plug into unused conduit opening. 3. For SSM24 and SSV120 alarm bells, remove gong (refer to SSM and SSV bell series installation manual) and complete field wiring. 4. Mount bell to WBB with 4 #8-32 x 3⁄4″ screws (Figure 2) supplied with product. Figure 3: Knockout plug removal 1. If a rear conduit entry is required, remove the knockout plug using a flat blade screwdriver as shown in Figure 3. Strike sharply with a hammer to pierce the wall of the A0134-00 knockout plug. Move to an adjacent wall section and repeat until the plug falls out. Make sure that the back box is supported adequately during this operation to avoid injury. 2. To meet weatherproof or outdoor listing, the conduit entrance must be gasketed. 3. Install 1⁄2″ NPT plugs (2) into unused conduit openings. I56-1893-005 © 2004 System Sensor

很抱歉,暂时无法提供与“WBB”相匹配的价格&库存,您可以联系我们找货

免费人工找货
K4A8G165WB-BCRC
  •  国内价格
  • 1+44.69599
  • 10+41.67599
  • 50+37.146
  • 150+34.126
  • 300+32.012
  • 500+31.106

库存:739