0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
WFDTH

WFDTH

  • 厂商:

    SYSTEMSENSOR

  • 封装:

  • 描述:

    WFDTH - Waterfl ow Detector - Systemsensor advanced ideas.

  • 数据手册
  • 价格&库存
WFDTH 数据手册
WFDTH Waterflow Detector The System Sensor WFDTH Retard T-Tap Waterflow Detector is designed for primary signaling in residential systems and fits within 2×4 stud wall construction. Features • Residential sprinkler systems • Sealed retard mechanism • Visual switch activation • Rugged, dual SPDT switches enclosed in a durable terminal block • Easy to install and maintain design • Vertical or horizontal mount • Field replaceable retard mechanism and switch assembly • Twelve different flexible paddles • Durable, tamper resistant enclosure • Two conduit openings • Handy depth gauge • Accommodates up to 12 AWG wire • 100% synchronization fires alarm panel and local bell simultaneously The WFDTH fits any tee that has a 1˝ NPT branch, including: 1˝, 1¼˝, 1½˝, and 2˝ NPT threaded ferrous and brass tees; 1˝, 1¼˝, 1½˝ and 2˝ copper sweat tees; Central, Spears®, and Victaulic® brand 1˝ CPVC tees; and 1½˝ polybutylene tees. Design. The design of the WFDTH makes it easy to install and simple to maintain. It can be mounted in the vertical or horizontal position. Two conduit openings permit easy attachment to the local alarm system. The retard mechanism and switch assembly are fieldreplaceable. Features. Twelve different flexible paddles fit 1˝, 1¼˝, 1½˝, and 2˝ tees. Sizes are marked clearly on the paddle for ease of installation. Plastic paddles slip over the actuating lever and are securely fastened with one screw. The handy depth gauge insures the proper installation depth and clearance of the detector to the tee. Construction. The WFDTH includes a durable and tamper resistant enclosure. Its sealed retard assures that the delay mechanism is not contaminated by dust and dirt when the cover is removed. The long lasting cover completely encloses the electrical components to further keep out dust and dirt. Improved self-guiding security screws and removal tools make detectors resistant to tampering and simplify field maintenance. Agency Listings S739 CS169 7770-1653:114 167-93-E WFDTH Specifications Architectural/Engineering Specifications Model shall be a WFDTH as manufactured by System Sensor. T-tap waterflow detectors shall be installed on a tee that has a 1˝ NPT branch including: 1˝, 1¼˝, 1½˝, or 2˝ threaded ferrous or brass tee; 1–2˝ copper sweat tees; Central, Spears®, and Victaulic® brand 1˝ CPVC tees; or 1½˝ polybutylene tee as designated on the drawings and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate size, either a vertical or horizontal run at least 6˝ from any fittings or valves which may change water direction, flow rate, or pipe diameter or no closer than 24˝ from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 250 psi. The retard t-tap detector shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through the tee fitting and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances (one of which is a knockout type) for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. WFDTH is listed by Underwriters Laboratories for indoor use. Physical/Operating Specifications Static Pressure Rating 250 PSI (max.) Maximum Surge 18 FPS Triggering Threshold 4–10 GPM Bandwidth (Flow Rate) Overall Dimensions, 4.5˝ H × 3.55˝ W × 6.7˝ L Installed (11.4cm H × 9cm W × 17cm L) Operating Temperature Range 32°F to 120°F (0°C to 49°C) Enclosure Rating UL listed for indoor use Cover Tamper Switch Canadian models only, factory installed Service Use Automatic Sprinkler: NFPA 13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA 72 2.6 lbs. (1.2 kg.) Contact Ratings Compatible Tee Fittings Conduit Entrances Two sets of SPDT (Form C) Shipping Weight 10.0 A @ 125/250 VAC 2.5 A @ 24 VDC Threaded ferrous and brass tees, copper Warranty sweat tees, CPVC tees, and polybutylene tees Two openings for ½˝ conduit. U.S. Patent Numbers 3 years 3,845,259; 4,782,333; 5,213,205 Electrical Connections T16-0010-XXX B COM •CAUTION• ROUTE WIRING AWAY FROM SHARP EDGES & COPONENTS A Delay Adjustment Dial CONTACT RATINGS 125/250 VAC 10 AMPS 24 VDC 2.5 AMPS 0 Delay adjustment dial NU SWITCH 1 SWITCH 2 WFDT/WFDTH B B WFDT/WFDTH B B 45 To nonsilenceable initiating zone of listed FACP end-of-line resistor COM COM COM COM NOTE: Retard time may exceed 90 seconds. Adjust and verify that time does not exceed 90 seconds. Typical FACP Connection To power source compatible with bell B Break wire as shown for supervision of connection. DO NOT allow stripped wire leads to extend beyond switch housing. DO NOT loop wires. Typical Local Bell Connection WFDT, WFDTH switch assembly COM local bell Ordering Information UL Model No. WFDTH Accessories A77-01-02 PRK9 A3008-00 ULC/Canadian Model No. WFDTHA Description Waterflow Detector, Fits 1˝, 1¼˝, 1½˝, 2˝ ferrous and brass threaded tees; 1˝, 1¼˝, 1½˝, 2˝ copper sweat tees; 1˝ CPVC tees; and 1½˝ polybutylene tees S07-66002 WFDW C58-0009-000 Replacement tamper screws for covers of WFDTH Replacement tamper proof wrench for cover of WFDTH Replacement metal cover Replacement terminal block for WFDTH Replacement paddle kit – 12 paddles for WFDTH (see WFDTH for sizes included) Replacement retard mechanism Spears® is a registered trademark of the Spears Manufacturing Company. Victaulic® is a registered trademark of the Victaulic Company of America. 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2007 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0941-007 • 4/07 • #1676 55 70 CO M SWITCH SCHEMATIC •READY• STATE M CO NOTE: Common and B connections will close when vane is deflected, i.e., when water is flowing. Dual switches permit applications to be combined on a single detector. DIAL IS APP R ON R DELAY IN SECO OXI ND MA BE M IME S T TE 15 30
WFDTH 价格&库存

很抱歉,暂时无法提供与“WFDTH”相匹配的价格&库存,您可以联系我们找货

免费人工找货