for General Electronic Equipment
Notice for TAIYO YUDEN products
Please read this notice before using the TAIYO YUDEN products.
REMINDERS
■ Product Information in this Catalog
Product information in this catalog is as of October
2020. All
All of
of the
the
January 2021.
contents specified herein and production status of the products listed in
this catalog are subject to change without notice due to technical
improvement of our products, etc. Therefore, please check for the latest
information carefully before practical application or use of our products.
(4) Powe r g e n e r atio n c o ntro l e quip m e nt (nu c le a r p owe r,
hydroelectric power, thermal power plant control system, etc.)
(5) Undersea equipment (submarine repeating equipment,
underwater work equipment, etc.)
(6) Military equipment
(7) Any other equipment requiring extremely high levels of safety
and/or reliability equal to the equipment listed above
Please note that TAIYO YUDEN shall not be in any way responsible
for any damages and defects in products or equipment incorporating
our products, which are caused under the conditions other than those
specified in this catalog or individual product specification sheets.
*Notes:
1. There is a possibility that our products can be used only
for aviation equipment that does not directly affect the safe
operation of aircraft (e.g., in-flight entertainment, cabin
light, electric seat, cooking equipment) if such use meets
requirements specified separately by TAIYO YUDEN. Please
be sure to contact TAIYO YUDEN for further information
before using our products for such aviation equipment.
2. Implantable medical devices contain not only internal unit
which is implanted in a body, but also external unit which is
connected to the internal unit.
■ Approval of Product Specifications
Ple a se c ont ac t TA IYO YUD EN for fur the r det a ils of p ro duc t
specifications as the individual product specification sheets are
available. When using our products, please be sure to approve our
product specifications or make a written agreement on the product
specification with TAIYO YUDEN in advance.
■ Pre-Evaluation in the Actual Equipment and Conditions
Please conduct validation and verification of our products in actual
conditions of mounting and operating environment before using our
products.
■ Limited Application
1. Equipment Intended for Use
The products listed in this catalog are intended for generalpurpose and standard use in general electronic equipment (e.g.,
AV equipment, OA equipment, home electric appliances, office
equipment, information and communication equipment including,
without limitation, mobile phone, and PC) and other equipment
specified in this catalog or the individual product specification sheets.
TAIYO YUDEN has the line-up of the products intended for
use in automotive electronic equipment, telecommunications
infrastructure and industrial equipment, or medical devices
classified as GHTF Classes A to C (Japan Classes I to III).
Therefore, when using our products for these equipment,
please check available applications specified in this catalog
or the individual product specification sheets and use the
corresponding products.
2. Equipment Requiring Inquiry
Please be sure to contact TAIYO YUDEN for further information
before using the products listed in this catalog for the following
equipment (excluding intended equipment as specified in this
catalog or the individual product specification sheets) which may
cause loss of human life, bodily injury, serious property damage
and/or serious public impact due to a failure or defect of the
products and/or malfunction attributed thereto.
(1) Transportation equipment (automotive powertrain control
system, train control system, and ship control system, etc.)
(2) Traffic signal equipment
(3) Disaster prevention equipment, crime prevention equipment
(4) Medical devices classified as GHTF Class C (Japan Class III)
(5) H i g h l y p u b l i c i n f o r m a t i o n n e t wo r k e q u i p m e n t , d a t a processing equipment (telephone exchange, and base
station, etc.)
(6) Any other equipment requiring high levels of quality and/or
reliability equal to the equipment listed above
3. Equipment Prohibited for Use
Please do not incorporate our products into the following
equipment requiring extremely high levels of safety and/or
reliability.
(1) Aerospace equipment (artificial satellite, rocket, etc.)
(2) Aviation equipment *1
(3) Medical devices classified as GHTF Class D (Japan Class IV),
implantable medical devices *2
4. Limitation of Liability
Please note that unless you obtain prior written consent of TAIYO
YUDEN, TAIYO YUDEN shall not be in any way responsible for
any damages incurred by you or third parties arising from use of
the products listed in this catalog for any equipment that is not
intended for use by TAIYO YUDEN, or any equipment requiring
inquiry to TAIYO YUDEN or prohibited for use by TAIYO YUDEN
as described above.
■ Safety Design
When using our products for high safety and/or reliability-required
equipment or circuits, please fully perform safety and/or reliability
evaluation. In addition, please install (i) systems equipped with
a protection circuit and a protection device and/or (ii) systems
equipped with a redundant circuit or other system to prevent an
unsafe status in the event of a single fault for a failsafe design to
ensure safety.
■ Intellectual Property Rights
Information contained in this catalog is intended to convey examples
of typical performances and/or applications of our products and is
not intended to make any warranty with respect to the intellectual
property rights or any other related rights of TAIYO YUDEN or any
third parties nor grant any license under such rights.
■ Limited Warranty
Please note that the scope of warranty for our products is limited to
the delivered our products themselves and TAIYO YUDEN shall not
be in any way responsible for any damages resulting from a failure
or defect in our products. Notwithstanding the foregoing, if there is
a written agreement (e.g., supply and purchase agreement, quality
assurance agreement) signed by TAIYO YUDEN and your company,
TAIYO YUDEN will warrant our products in accordance with such
agreement.
■ TAIYO YUDEN’s Official Sales Channel
The contents of this catalog are applicable to our products which are
purchased from our sales offices or authorized distributors (hereinafter
“TAIYO YUDEN’
s official sales channel”). Please note that the contents
of this catalog are not applicable to our products purchased from any
seller other than TAIYO YUDEN’
s official sales channel.
■ Caution for Export
Some of our products listed in this catalog may require specific
procedures for export according to“U.S. Export Administration
Regulations”,“Foreign Exchange and Foreign Trade Control Law”
of Japan, and other applicable regulations. Should you have any
questions on this matter, please contact our sales staff.
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our product specification sheets.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our website (http://www.ty-top.com/) .
2
21
for General Electronic Equipment
LEADED COMMON MODE CHOKE COILS FOR DC AND SIGNAL LINES
LEADED COMMON MODE CHOKE COILS FOR DC AND SIGNAL LINES
WAVE
■PARTS NUMBER
T
L F
①
△ 9
②
U
B H
③
3
0 2
④
W
⑤
K
1
△=Blank space
⑥
④Nominal inductance
Code
(example)
302
203
⑤Inductance tolerance
Code
W
⑥Internal code
Code
K1
Series name
Common mode choke coil
Dimensions of core[mm]
9
Shape
U core, vertically split wound
U core, horizontally split wound
Nominal inductance[μH]
3000
20000
Inductance tolerance
+100/-10%
NOISE SUPPRESSION
COMPONENTS
①Series name
Code
TLF
②Dimensions of core
Code
△9
③Shape
Code
UB△
UBH
* Operating Temp.:-25~+105℃(Including self-generated heat)
Internal code
Adhesive fixation
■STANDARD EXTERNAL DIMENSIONS / MINIMUM QUANTITY
TLF 9UB Type
11.0max
TLF 9UBH Type
17.0max
17.0max
15.0max
COMMON MODE CHOKE COILS
12.0max
16.0max
φ0.6
φ0.6
④
4.5±1.0
4.5±1.0
④
③
③
8.0±0.5
(0.315±0.020)
①
7.0±0.5
(0.276±0.020)
8.0±0.5
(0.315±0.020)
①
②
7.0±0.5
(0.276±0.020)
②
Minimum quantity (pcs.)
Box
500
Minimum quantity (pcs.)
Box
500
Unit:mm(inch)
■PARTS NUMBER
Parts number
TLF
TLF
TLF
TLF
TLF
TLF
9UBH302W
9UB 302W
9UBH802W
9UB 802W
9UBH203W
9UB 203W
K1
K1
K1
K1
K1
K1
EHS
Number of
lines
Nominal
inductance [mH]
Inductance
tolerance
DC Resistance
[Ω](max.)
Rated current
[A](max.)
Rated voltage
[V](D.C.)
Insulation
resistance
[MΩ](min.)
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
2
2
2
2
2
2
3.0
3.0
8.0
8.0
20.0
20.0
+100/-10%
+100/-10%
+100/-10%
+100/-10%
+100/-10%
+100/-10%
1.5
1.5
3.0
3.0
6.5
6.5
0.40
0.40
0.30
0.30
0.18
0.18
50
50
50
50
50
50
100
100
100
100
100
100
coil_leaded_dc_signalline_e-E08R01.doc
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our product specification sheets.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our website (http://www.ty-top.com/) .
21
91
LEADED COMMON MODE CHOKE COILS FOR DC AND SIGNAL LINES
LEADED COMMON MODE CHOKE COILS FOR AC LINES
■PACKAGING
①Minimum Quantity
●TLH/TLF Type
Type
TLH10UA
TLH10UB
TLF9UA□
TLF9UB□
Minimum Quantity[pcs]
Box
1000
500
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
coil_leaded_pack_e-E08R01
LEADED COMMON MODE CHOKE COILS FOR DC AND SIGNAL LINES,
LEADED COMMON MODE CHOKE COILS FOR AC LINES
■RELIABILITY DATA
1. Operating Temperature Range
Specified Value
TLH, TLF Type
-25~+ 105℃
Test Method and
Remarks
Including temperature rise due to self-generated heat.
2. Storage temperature range
Specified Value
TLH, TLF Type
-40~+ 85℃
Specified Value
TLH, TLF Type
Within the specified range
Test Method and
Remarks
TLH10U
TLF9UA
TLF9UB
3. Rated current
: The maximum value of AC current within the temperature rise of 60℃
: The maximum value of AC current within the temperature rise of 45℃
: The maximum value of DC current within the temperature rise of 45℃
4. Inductance
Specified Value
TLH, TLF Type
Within the specified tolerance
Test Method and
Remarks
TLF9U :
Measuring equipment
Measuring frequency
Measuring voltage
TLH、TLF(except TLF9U) :
Measuring equipment
Measuring frequency
Measuring voltage
: LCR meter 4284A or its equivalent
: 1kHz
: 1Vrms
: LCR meter 4284A or its equivalent
: 1kHz
: 0.1Vrms
5. DC resistance
Specified Value
Test Method and
Remarks
TLH, TLF Type
Within the specified tolerance
Measuring equipment
: DC ohmmeter
6. Terminal strength tensile force
Specified Value
Test Method and
Remarks
TLH, TLF Type
No abnormality
TLH10UA, TLH10UB, TLF9U : Apply the stated tensile force gradually in the direction to draw terminal.
force [N]
duration [s]
5
30±5
TLF (except TLF9U): Apply the stated tensile force gradually in the direction to draw terminal.
force [N]
duration [s]
10
30±5
7. Insulation resistance between wires
Specified Value
Test Method and
Remarks
TLH, TLF Type
Applied voltage
Duration
100MΩmin.
: 500VDC (TLH, TLF (except TLF9UB))
: 250VDC (TLF9UB)
: 60sec.
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
coil_leaded_reli_e-E08R01
8. Insulation resistance between wire and core
Specified Value
Test Method and
Remarks
TLH, TLF Type
TLF :
Applied voltage
Duration
100MΩ min.(except TLH)
: 500VDC (TLF (except TLF9UB))
: 250VDC (TLF9UB)
: 60 sec.
9. Withstanding : between wires
Specified Value
Test Method and
Remarks
TLH, TLF Type
Applied voltage
Duration
No abnormality
: 2000VAC (TLH, TLF (except TLF9UB))
: 500VDC (TLF9UB)
: 60sec
10. Withstanding : between wires and core
Specified Value
Test Method and
Remarks
TLH, TLF Type
TLF :
Applied voltage
Duration
No abnormality(except TLH)
: 2000VAC (TLF (except TLF9UB))
: 500VDC (TLF9UB)
: 60sec.
11. Rated voltage
Specified Value
TLH, TLF Type
Within the specified range
Test Method and
Remarks
TLH, TLF (except TLF9UB)
TLF9UB
: 250VAC
: 50VDC
12. Resistance to vibration
TLF9U : Inductance change : Within ±5%
TLH, TLF (except TLF9U) : Appearance is no abnormality and within the specified range
Specified Value
TLH, TLF Type
Test Method and
Remarks
TLH, TLF : According to JIS C60068-2-6.
Direction
: 2hrs each in X, Y and Z direction Total : 6hrs
Frequency range
: 10 to 55 to 10Hz (1 min.)
Amplitude
: 1.5mm (shall not exceed acceleration 196m/s2)
Mounting method
: soldering onto PC board
Recovery
: At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the
measurement within 2hrs.
13. Solderability
Specified Value
Test Method and
Remarks
TLH, TLF Type
At least 90% of terminal electrode is covered by new solder.
TLH, TLF :
Solder temperature
Duration
Immersion depth
: 235±0.5℃
: 2±0.5sec.
: Up to 1.5 to 2.0mm from PBC mounted level.
TLH, TLF :
Solder temperature
Duration
Immersion depth
: 245±5℃
: 4±1sec.
: Up to 1.0 to 1.5mm from PBC mounted level.
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
coil_leaded_reli_e-E08R01
14. Resistance to soldering heat
Specified Value
Test Method and
Remarks
TLH, TLF Type
TLF9UA : Inductance change : Within ±5%
TLH, TLF :
Solder temperature
Duration
Immersion depth
Recovery
:
:
:
:
260±5℃
5±0.5sec.
Up to 1.5 to 2.0mm from PBC mounted level.
At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the
measurement within 2hrs.
TLH, TLF :
Solder temperature
Duration
Immersion depth
Recovery
:
:
:
:
260±5℃
10±1sec.
Up to 1.0 to 1.5mm from PBC mounted level.
At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the
measurement within 2hrs.
15. Thermal shock
Specified Value
Test Method and
Remarks
TLF9UA : Inductance change : Within ±15%
TLH, TLF (except TLF9UA) : Withstanding voltage : No abnormality
Insulation resistance : No abnormality
TLH, TLF Type
TLH, TLF : According to JIS C60068-2-14.
Conditions for 1 cycle
-25℃~+85℃、keep each 30min
Number of cycles
Recovery
: 10
: At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the
measurement within 2 hrs.
16. Damp heat
Specified Value
TLH, TLF :
Temperature
Test Method and
Remarks
TLF9UA : Inductance change : Within ±15%
TLH, TLF (except TLF9UA) : Withstanding voltage : No abnormality
Insulation resistance : No abnormality
TLH, TLF Type
Humidity
Duration
Recovery
:
:
:
:
:
60±2℃
40±2℃ (※except TLF9U)
90~95%RH
500 hrs
At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs.
17. Loading under damp heat
Specified Value
TLH, TLF :
Temperature
Test Method and
Remarks
Withstanding voltage : No abnormality
Insulation resistance : No abnormality
TLH, TLF Type
Humidity
Duration
Applied voltage
Recovery
:
:
:
:
:
:
60±2℃
40±2℃ (※except TLF9U )
90~95%RH
100 hrs
500 hrs Apply rated current across windings (※except TLF9U )
Apply the following specified voltage between windings.
TLF9UA
250VAC
TLF9UB
50VDC
: At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs.
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
coil_leaded_reli_e-E08R01
18. Low temperature life test
Specified Value
Test Method and
Remarks
TLF9U : Inductance change : Within ±15%
TLH, TLF (except TLF9U) : Withstanding voltage : No abnormality
Insulation resistance : No abnormality
TLH, TLF Type
TLH, TLF :
Temperature
Duration
Recovery
:
:
:
:
-25±2℃
-40±2℃ (※TLF・TLH )
500 hrs
At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs.
19. High Temperature life test
Specified Value
TLH, TLF Type
Test Method and
Remarks
TLH, TL F :
Temperature
Duration
Recovery
TLF9U : Inductance change : Within ±15%
TLH, TLF (except TLF9U) : Withstanding voltage : No abnormality
Insulation resistance : No abnormality
: 105±3℃ (※ TLF・TLH)
: 500 hrs
: At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs.
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
coil_leaded_reli_e-E08R01
LEADED COMMON MODE CHOKE COILS FOR DC AND SIGNAL LINES,
LEADED COMMON MODE CHOKE COILS FOR AC LINES
■PRECAUTIONS
1. Circuit Design
Precautions
◆Operating environment
1. The products described in this specification are intended for use in general electronic equipment, (office supply equipment,
telecommunications systems, measuring equipment, and household equipment). They are not intended for use in mission-critical
equipment or systems requiring special quality and high reliability (traffic systems, safety equipment, aerospace systems, nuclear
control systems and medical equipment including life-support systems) where product failure might result in loss of life, injury or
damage. For such uses, contact TAIYO YUDEN Sales Department in advance.
2. PCB Design
Precautions
Technical
considerations
◆Design
1. Please design insertion pitches as matching to that of leads of the component on PCBs.
◆Design
1. When Inductors are mounted onto a PC board, hole dimensions on the board should match the lead pitch of the component, if not, it will
cause breakage of the terminals or cracking of terminal roots covered with resin as excess stress travels through the terminal legs.
3. Soldering
Precautions
◆Wave soldering
1. Please refer to the specifications in the catalog for a wave soldering.
2. Do not immerse the entire inductor in the flux during the soldering operation.
◆Lead free soldering
1. When using products with lead free soldering, we request to use them after confirming of adhesion, temperature of resistance to
soldering heat, etc. sufficiently.
◆Recommended conditions for using a soldering iron
・ Put the soldering iron on the land-pattern.
・ Soldering iron's temperature - Below 350℃
・ Duration - 3 seconds or less
・ The soldering iron should not directly touch the product.
Technical
considerations
◆Lead free soldering
1. If products are used beyond the range of the recommended conditions, heat stresses may deform the products, and consequently
degrade the reliability of the products.
◆Recommended conditions for using a soldering iron
If products are used beyond the range of the recommended conditions, heat stresses may deform the products, and consequently degrade
the reliability of the products.
4. Cleaning
Precautions
◆Cleaning conditions
1. Please contact any of our offices for about a cleaning.
5. Handling
Precautions
Technical
considerations
◆Handling
1. Keep the product away from all magnets and magnetic objects.
◆Mechanical considerations
1. Please do not give the product any excessive mechanical shocks.
2. Please do not add any shock or power to a product in transportation.
◆Packing
1. Please do not give the product any excessive mechanical shocks.
In loading, please pay attention to handling indication mentioned in a packing box (a loading direction / number of maximum loading /
fragile item).
◆Handling
1. There is a case that a characteristic varies with magnetic influence.
◆Mechanical considerations
1. There is a case to be damaged by a mechanical shock.
2. There is a case to be broken by a fall.
◆Packing
1. There is a case that a lead route turns at by a fall or an excessive shock.
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
coil_leaded_prec_e-E08R01
6. Storage conditions
Precautions
◆Storage
1. To maintain the solderability of terminal electrodes and to keep the packing material in good condition, temperature and humidity in the
storage area should be controlled.
・ Recommended conditions
Ambient temperature : 0~40℃
Humidity : Below 70% RH
The ambient temperature must be kept below 30℃. Even under ideal storage conditions, the solderbility of electrodes decreases
gradually, so the products should be mounted within one year from the time of delivery.
In case of storage over 6 months, solderability shall be checked before actual usage.
Technical
considerations
◆Storage
1. Under a high temperature and humidity environment, problems such as reduced solderability caused by oxidation of terminal electrodes
and deterioration of taping/packaging materials may take place.
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
coil_leaded_prec_e-E08R01