LSQBB160808T100K

LSQBB160808T100K

  • 厂商:

    TAIYO-YUDEN(太诱)

  • 封装:

    0603

  • 描述:

    10 µH 无屏蔽 绕线 电感器 80 mA 360 毫欧 0603(1608 公制)

  • 数据手册
  • 价格&库存
LSQBB160808T100K 数据手册
Notice for TAIYO YUDEN Products Please read this notice before using the TAIYO YUDEN products. REMINDERS ■ Product Information in this Catalog Product information in this catalog is as of October 2021. All of the contents specified herein and production status of the products listed in this catalog are subject to change without notice due to technical improvement of our products, etc. Therefore, please check for the latest information carefully before practical application or use of our products. Please note that TAIYO YUDEN shall not be in any way responsible for any damages and defects in products or equipment incorporating our products, which are caused under the conditions other than those specified in this catalog or individual product specification sheets. ■ Approval of Product Specifications Please contact TAIYO YUDEN for further details of product specifications as the individual product specification sheets are available. When using our products, please be sure to approve our product specifications or make a written agreement on the product specification with TAIYO YUDEN in advance. ■ Pre-Evaluation in the Actual Equipment and Conditions Please conduct validation and verification of our products in actual conditions of mounting and operating environment before using our products. ■ Safety Design When using our products for high safety and/or reliability-required equipment or circuits, please fully perform safety and/or reliability evaluation. In addition, please install (i) systems equipped with a protection circuit and a protection device and/or (ii) systems equipped with a redundant circuit or other system to prevent an unsafe status in the event of a single fault for a failsafe design to ensure safety. ■ Intellectual Property Rights Information contained in this catalog is intended to convey examples of typical performances and/or applications of our products and is not intended to make any warranty with respect to the intellectual property rights or any other related rights of TAIYO YUDEN or any third parties nor grant any license under such rights. ■ Limited Warranty Please note that the scope of warranty for our products is limited to the delivered our products themselves conforming to the product specifications specified in the individual product specification sheets, and TAIYO YUDEN shall not be in any way responsible for any damages resulting from a failure or defect in our products. Notwithstanding the foregoing, if there is a written agreement (e.g., supply and purchase agreement, quality assurance agreement) signed by TAIYO YUDEN and your company, TAIYO YUDEN will warrant our products in accordance with such agreement, provided, however, that our products shall be used for general-purpose and standard use in the equipment specified in this catalog or the individual product specification sheets. ■ TAIYO YUDEN’s Official Sales Channel The contents of this catalog are applicable to our products which are purchased from our sales offices or authorized distributors (hereinafter “TAIYO YUDEN’s official sales channel”). Please note that the contents of this catalog are not applicable to our products purchased from any seller other than TAIYO YUDEN’s official sales channel. ■ Caution for Export Some of our products listed in this catalog may require specific procedures for export according to “U.S. Export Administration Regulations”, “Foreign Exchange and Foreign Trade Control Law” of Japan, and other applicable regulations. Should you have any questions on this matter, please contact our sales staff. 22 ■ Limited Application 1. Equipment Intended for Use The products listed in this catalog are intended for general-purpose and standard use in general electronic equipment for consumer (e.g., AV equipment, OA equipment, home electric appliances, office equipment, information and communication equipment including, without limitation, mobile phone, and PC) and other equipment specified in this catalog or the individual product specification sheets, or the equipment approved separately by TAIYO YUDEN. TAIYO YUDEN has the product series intended for use in the following equipment. Therefore, when using our products for these equipment, please check available applications specified in this catalog or the individual product specification sheets and use the corresponding products. Product Series Application Equipment Automotive Industrial Medical Consumer *1 Category (Part Number Code *2 ) Quality Grade *3 Automotive Electronic Equipment (POWERTRAIN, SAFETY) A 1 Automotive Electronic Equipment (BODY & CHASSIS, INFOTAINMENT) C 2 Telecommunications Infrastructure and Industrial Equipment B 2 Medical Devices classified as GHTF Class C (Japan Class III) M 2 Medical Devices classified as GHTF Classes A or B (Japan Classes I or II) L 3 General Electronic Equipment S 3 *Notes: 1. Based on the general specifications required for electronic components for such equipment, which are recognized by TAIYO YUDEN, the use of each product series for the equipment is recommended. Please be sure to contact TAIYO YUDEN before using our products for equipment other than those covered by the product series. 2. On each of our part number, the 2nd code from the left is a code indicating the “Category” as shown in the above table. For details, please check the explanatory materials regarding the part numbering system of each of our products. 3. Each product series is assigned a “Quality Grade” from 1 to 3 in order of higher quality. Please do not incorporate a product into any equipment with a higher Quality Grade than the Quality Grade of such product without the prior written consent of TAIYO YUDEN. 2. Equipment Requiring Inquiry Please be sure to contact TAIYO YUDEN for further information before using the products listed in this catalog for the following equipment (excluding intended equipment as specified in this catalog or the individual product specification sheets) which may cause loss of human life, bodily injury, serious property damage and/or serious public impact due to a failure or defect of the products and/or malfunction attributed thereto. (1) Transportation equipment (automotive powertrain control system, train control system, and ship control system, etc.) (2) Traffic signal equipment (3) Disaster prevention equipment, crime prevention equipment (4) Medical devices classified as GHTF Class C (Japan Class III) (5) Highly public information network equipment, data-processing equipment (telephone exchange, and base station, etc.) (6) Any other equipment requiring high levels of quality and/or reliability equal to the equipment listed above 3. Equipment Prohibited for Use Please do not incorporate our products into the following equipment requiring extremely high levels of safety and/or reliability. (1) Aerospace equipment (artificial satellite, rocket, etc.) (2) Aviation equipment *1 (3) Medical devices classified as GHTF Class D (Japan Class IV), implantable medical devices *2 (4) Power generation control equipment (nuclear power, hydroelectric power, thermal power plant control system, etc.) (5) Undersea equipment (submarine repeating equipment, etc.) (6) Military equipment (7) Any other equipment requiring extremely high levels of safety and/or reliability equal to the equipment listed above *Notes: 1. There is a possibility that our products can be used only for aviation equipment that does not directly affect the safe operation of aircraft (e.g., in-flight entertainment, cabin light, electric seat, cooking equipment) if such use meets requirements specified separately by TAIYO YUDEN. Please be sure to contact TAIYO YUDEN for further information before using our products for such aviation equipment. 2. Implantable medical devices contain not only internal unit which is implanted in a body, but also external unit which is connected to the internal unit. 4. Limitation of Liability Please note that unless you obtain prior written consent of TAIYO YUDEN, TAIYO YUDEN shall not be in any way responsible for any damages incurred by you or third parties arising from use of the products listed in this catalog for any equipment that is not intended for use by TAIYO YUDEN, or any equipment requiring inquiry to TAIYO YUDEN or prohibited for use by TAIYO YUDEN as described above. 22 for General Electronic Equipment Wire-wound Ferrite Inductors LSQB/LSQC/LSQE series for General Electronic Equipment for Consumer シリーズ前の記号は、品番から抽出したものであり、製品の種類や特性などの区分を示すためのものです。 REFLOW ■PART NUMBER L S Q ① * Operating Temp.:-40~+105℃(Including self-generated heat) B ①Series Code (1)(2)(3)(4) LSQB LSQC LSQE A ② S 0 1 ③ 2 1 2 T ⑤ ④ 1 0 0 ⑥ M ⑦ ⑧ ⑨ Wire-wound Ferrite Inductor for General Electronic Equipment for Consumer Wire-wound Ferrite Inductor for General Electronic Equipment for Consumer Wire-wound Ferrite Inductor for General Electronic Equipment for Consumer (1) Product Group Code L (2) Category Code 2 Inductors Recommended equipment General Electronic Equipment for Consumer ②Features Code A B (3) Type Code Q Quality Grade 3 Feature 5-surface electrode (Ag-resin×Sn-plate) L-shape electrode (Ag-resin×Sn-plate) ③Dimensions(L×W) Code Type(inch) 1608 2012 2016 2518 3218 3225 1608(0603) 2012(0805) 2016(0806) 2518(1007) 3218(1207) 3225(1210) ④Dimensions(T) Code 08 12 16 18 25 Dimensions(L×W) [mm] 1.6×0.8 2.0×1.25 2.0×1.6 2.5×1.8 3.2×1.8 3.2×2.5 Dimensions(T)[mm] 0.8 1.25 1.6 1.8 2.5 Ferrite Wire-wound (Horizontal type) (4) Features, Characteristics Code B C E ⑤Packaging Code T ⑥Nominal inductance Code (example) 1R0 100 101 ※R=Decimal point ⑦Inductance tolerance Code K M ⑧Special code Code R Standard High current Low Rdc Packaging Taping Nominal inductance[µH] 1.0 10 100 Inductance tolerance ±10% ±20% Special code Low Rdc type ⑨Internal code ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . CATALOG 2022 i_wound_LB_S_e-E10R01 for General Electronic Equipment ■STANDARD EXTERNAL DIMENSIONS / STANDARD QUANTITY 5-surface electrode L-shape electrode W W L L T T e Type A160808 B160808 A201212 A201616 A251818 A321818 A322525 e Recommended Land Patterns Surface Mounting ・Mounting and soldering conditions should be checked beforehand. ・Applicable soldering process to these products is reflow soldering only. Type A B C A1608 0.55 0.7 0.9 C B1608 0.55 0.7 1.0 A2012 0.60 1.0 1.45 A2016 0.60 1.0 1.8 A2518 0.60 1.5 2.0 A B A A3218 0.85 1.7 2.0 A3225 0.85 1.7 2.7 Unit:mm L W T e 1.6±0.1 (0.063±0.004) 1.6±0.2 (0.063±0.008) 2.0±0.2 (0.079±0.008) 2.0±0.2 (0.079±0.008) 2.5±0.2 (0.098±0.008) 3.2±0.2 (0.126±0.008) 3.2±0.2 (0.126±0.008) 0.8±0.1 (0.031±0.004) 0.8±0.2 (0.031±0.008) 1.25±0.2 (0.049±0.008) 1.6±0.2 (0.063±0.008) 1.8±0.2 (0.071±0.008) 1.8±0.2 (0.071±0.008) 2.5±0.2 (0.098±0.008) 0.8±0.1 (0.031±0.004) 0.8±0.2 (0.031±0.008) 1.25±0.2 (0.049±0.008) 1.6±0.2 (0.063±0.008) 1.8±0.2 (0.071±0.008) 1.8±0.2 (0.071±0.008) 2.5±0.2 (0.098±0.008) 0.35±0.15 (0.014±0.006) 0.45±0.15 (0.016±0.006) 0.5±0.2 (0.020±0.008) 0.5±0.2 (0.020±0.008) 0.5±0.2 (0.020±0.008) 0.6±0.2 (0.024±0.008) 0.6±0.3 (0.024±0.012) Standard quantity[pcs] Paper tape Embossed tape 4000 - - 3000 - 3000 - 2000 - 2000 - 2000 - 1000 Unit:mm(inch) ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . CATALOG 2022 i_wound_LB_S_e-E10R01 for General Electronic Equipment ■PART NUMBER ●1608(0603) type New part number LSQBA160808T1R0M LSQBA160808T2R2M LSQBA160808T4R7M LSQBA160808T8R2M LSQBA160808T100M New part number LSQBB160808T1R0M LSQBB160808T2R2M LSQBB160808T3R3M LSQBB160808T4R7M LSQBB160808T100K LSQBB160808T100M LSQBB160808T220K LSQBB160808T220M LSQBB160808T470K LSQBB160808T470M LB LB LB LB LB Old part number (for reference) 1608T1R0M 1608T2R2M 1608T4R7M 1608T8R2M 1608T100M Old part number (for reference) LBMF1608T1R0M LBMF1608T2R2M LBMF1608T3R3M LBMF1608T4R7M LBMF1608T100K LBMF1608T100M LBMF1608T220K LBMF1608T220M LBMF1608T470K LBMF1608T470M EHS RoHS RoHS RoHS RoHS RoHS EHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS Nominal inductance [μH] 1.0 2.2 4.7 8.2 10 Nominal inductance [μH] 1.0 2.2 3.3 4.7 10 10 22 22 47 47 Inductance tolerance ±20% ±20% ±20% ±20% ±20% Inductance tolerance ±20% ±20% ±20% ±20% ±10% ±20% ±10% ±20% ±10% ±20% Self-resonant frequency [MHz](min.) 100 80 45 32 32 DC Resistance [Ω](±30%) 0.17 0.33 0.55 0.70 0.70 Rated current [mA](max.) 160 115 70 60 60 Measuring frequency [MHz] 7.96 7.96 7.96 2.52 2.52 Self-resonant frequency [MHz](min.) 100 80 60 45 32 32 16 16 11 11 DC Resistance [Ω](±30%) 0.09 0.17 0.22 0.24 0.36 0.36 1.0 1.0 2.5 2.5 Rated current [mA](max.) 230 160 130 110 80 80 50 50 35 35 Measuring frequency [MHz] 7.96 7.96 7.96 7.96 2.52 2.52 2.52 2.52 2.52 2.52 Self-resonant frequency [MHz](min.) 100 80 55 45 38 32 32 32 32 28 28 16 16 11 11 10 10 8 8 DC Resistance [Ω](±30%) 0.15 0.23 0.30 0.40 0.47 0.70 0.70 0.50 0.50 1.3 1.3 1.7 1.7 3.7 3.7 6.0 6.0 7.0 7.0 Rated current [mA](max.) 405 260 235 190 135 120 120 120 120 100 100 80 80 60 60 50 50 45 45 Measuring frequency [MHz] 7.96 7.96 7.96 7.96 7.96 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 0.796 0.796 Self-resonant frequency [MHz](min.) 100 70 45 40 40 16 16 11 11 DC Resistance [Ω](±30%) 0.19 0.33 0.50 1.2 1.2 3.7 3.7 5.8 5.8 Rated current [mA](max.) 620 430 295 200 200 130 130 90 90 Measuring frequency [MHz] 7.96 7.96 7.96 2.52 2.52 2.52 2.52 2.52 2.52 Self-resonant frequency [MHz](min.) 100 80 45 32 32 16 16 11 11 8 8 DC Resistance [Ω](±30%) 0.07 0.13 0.24 0.36 0.36 1.0 1.0 1.7 1.7 4.0 4.0 Rated current [mA](max.) 400 260 200 150 150 100 100 75 75 50 50 Measuring frequency [MHz] 7.96 7.96 7.96 2.52 2.52 2.52 2.52 2.52 2.52 0.796 0.796 ●2012(0805) type LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB Old part number (for reference) 2012T1R0M 2012T2R2M 2012T3R3M 2012T4R7M 2012T6R8M 2012T100K 2012T100M 2012T100KR 2012T100MR 2012T150K 2012T150M 2012T220K 2012T220M 2012T470K 2012T470M 2012T680K 2012T680M 2012T101K 2012T101M LB LB LB LB LB LB LB LB LB Old part number (for reference) C2012T1R0M C2012T2R2M C2012T4R7M C2012T100K C2012T100M C2012T220K C2012T220M C2012T470K C2012T470M LB LB LB LB LB LB LB LB LB LB LB Old part number (for reference) R2012T1R0M R2012T2R2M R2012T4R7M R2012T100K R2012T100M R2012T220K R2012T220M R2012T470K R2012T470M R2012T101K R2012T101M New part number LSQBA201212T1R0M LSQBA201212T2R2M LSQBA201212T3R3M LSQBA201212T4R7M LSQBA201212T6R8M LSQBA201212T100K LSQBA201212T100M LSQBA201212T100KR LSQBA201212T100MR LSQBA201212T150K LSQBA201212T150M LSQBA201212T220K LSQBA201212T220M LSQBA201212T470K LSQBA201212T470M LSQBA201212T680K LSQBA201212T680M LSQBA201212T101K LSQBA201212T101M New part number LSQCA201212T1R0M LSQCA201212T2R2M LSQCA201212T4R7M LSQCA201212T100K LSQCA201212T100M LSQCA201212T220K LSQCA201212T220M LSQCA201212T470K LSQCA201212T470M New part number LSQEA201212T1R0M LSQEA201212T2R2M LSQEA201212T4R7M LSQEA201212T100K LSQEA201212T100M LSQEA201212T220K LSQEA201212T220M LSQEA201212T470K LSQEA201212T470M LSQEA201212T101K LSQEA201212T101M EHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS EHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS EHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS Nominal inductance [μH] 1.0 2.2 3.3 4.7 6.8 10 10 10 10 15 15 22 22 47 47 68 68 100 100 Nominal inductance [μH] 1.0 2.2 4.7 10 10 22 22 47 47 Nominal inductance [μH] 1.0 2.2 4.7 10 10 22 22 47 47 100 100 Inductance tolerance ±20% ±20% ±20% ±20% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% Inductance tolerance ±20% ±20% ±20% ±10% ±20% ±10% ±20% ±10% ±20% Inductance tolerance ±20% ±20% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% LSQB/LSQC series Rated Current : The maximum DC value having inductance decrease within 10 % and temperature increase within 20 degC by the application of DC bias. LSQE series Rated Current : The maximum DC value having inductance decrease within 20 % and temperature increase within 20 degC by the application of DC bias. ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . CATALOG 2022 i_wound_LB_S_e-E10R01 for General Electronic Equipment ■PART NUMBER ●2016(0806) type New part number LSQBA201616T1R0M LSQBA201616T1R5M LSQBA201616T2R2M LSQBA201616T3R3M LSQBA201616T4R7M LSQBA201616T6R8M LSQBA201616T100K LSQBA201616T100M LSQBA201616T150K LSQBA201616T150M LSQBA201616T220K LSQBA201616T220M LSQBA201616T330K LSQBA201616T330M LSQBA201616T470K LSQBA201616T470M LSQBA201616T680K LSQBA201616T680M LSQBA201616T101K LSQBA201616T101M LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB EHS Nominal inductance [μH] Inductance tolerance Self-resonant frequency [MHz](min.) DC Resistance [Ω](±30%) Rated current [mA](max.) Measuring frequency [MHz] 2016T1R0M 2016T1R5M 2016T2R2M 2016T3R3M 2016T4R7M 2016T6R8M 2016T100K 2016T100M 2016T150K 2016T150M 2016T220K 2016T220M 2016T330K 2016T330M 2016T470K 2016T470M 2016T680K 2016T680M 2016T101K 2016T101M RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 6.8 10 10 15 15 22 22 33 33 47 47 68 68 100 100 ±20% ±20% ±20% ±20% ±20% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% 100 80 70 55 45 38 32 32 28 28 16 16 14 14 11 11 10 10 8 8 0.09 0.11 0.13 0.20 0.25 0.35 0.50 0.50 0.70 0.70 1.0 1.0 1.7 1.7 2.4 2.4 3.0 3.0 4.5 4.5 490 380 375 285 225 200 155 155 130 130 105 105 85 85 70 70 55 55 40 40 7.96 7.96 7.96 7.96 7.96 7.96 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 0.796 0.796 Self-resonant frequency [MHz](min.) 100 80 70 55 45 38 32 32 28 28 16 16 14 14 11 11 10 10 8 8 DC Resistance [Ω](±30%) 0.10 0.15 0.20 0.27 0.37 0.59 0.82 0.82 1.2 1.2 1.8 1.8 2.8 2.8 4.3 4.3 7.0 7.0 8.0 8.0 Rated current [mA](max.) 690 600 520 410 355 290 245 245 200 200 165 165 135 135 110 110 95 95 75 75 Measuring frequency [MHz] 7.96 7.96 7.96 7.96 7.96 7.96 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 0.796 0.796 Self-resonant frequency [MHz](min.) 100 80 68 54 46 46 38 30 30 23 23 19 19 15 15 12 12 9.5 9.5 9.0 9.0 7.0 7.0 5.5 5.5 4.5 4.5 3.5 3.5 3.0 3.0 2.4 2.4 DC Resistance [Ω](±30%) 0.06 0.07 0.09 0.11 0.13 0.10 0.15 0.25 0.25 0.32 0.32 0.50 0.50 0.70 0.70 0.95 0.95 1.5 1.5 2.1 2.1 3.2 3.2 4.5 4.5 7.0 7.0 10 10 17 17 24 24 Rated current [mA](max.) 665 405 340 280 240 235 195 165 165 145 145 115 115 95 95 85 85 70 70 60 60 45 45 40 40 30 30 25 25 20 20 15 15 Measuring frequency [MHz] 7.96 7.96 7.96 7.96 7.96 7.96 7.96 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.252 0.252 LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB Old part number (for reference) C2016T1R0M C2016T1R5M C2016T2R2M C2016T3R3M C2016T4R7M C2016T6R8M C2016T100K C2016T100M C2016T150K C2016T150M C2016T220K C2016T220M C2016T330K C2016T330M C2016T470K C2016T470M C2016T680K C2016T680M C2016T101K C2016T101M LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB Old part number (for reference) 2518T1R0M 2518T1R5M 2518T2R2M 2518T3R3M 2518T4R7M 2518T4R7MR 2518T6R8M 2518T100K 2518T100M 2518T150K 2518T150M 2518T220K 2518T220M 2518T330K 2518T330M 2518T470K 2518T470M 2518T680K 2518T680M 2518T101K 2518T101M 2518T151K 2518T151M 2518T221K 2518T221M 2518T331K 2518T331M 2518T471K 2518T471M 2518T681K 2518T681M 2518T102K 2518T102M New part number LSQCA201616T1R0M LSQCA201616T1R5M LSQCA201616T2R2M LSQCA201616T3R3M LSQCA201616T4R7M LSQCA201616T6R8M LSQCA201616T100K LSQCA201616T100M LSQCA201616T150K LSQCA201616T150M LSQCA201616T220K LSQCA201616T220M LSQCA201616T330K LSQCA201616T330M LSQCA201616T470K LSQCA201616T470M LSQCA201616T680K LSQCA201616T680M LSQCA201616T101K LSQCA201616T101M Old part number (for reference) EHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS Nominal inductance [μH] 1.0 1.5 2.2 3.3 4.7 6.8 10 10 15 15 22 22 33 33 47 47 68 68 100 100 Inductance tolerance ±20% ±20% ±20% ±20% ±20% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ●2518(1007) type New part number LSQBA251818T1R0M LSQBA251818T1R5M LSQBA251818T2R2M LSQBA251818T3R3M LSQBA251818T4R7M LSQBA251818T4R7MR LSQBA251818T6R8M LSQBA251818T100K LSQBA251818T100M LSQBA251818T150K LSQBA251818T150M LSQBA251818T220K LSQBA251818T220M LSQBA251818T330K LSQBA251818T330M LSQBA251818T470K LSQBA251818T470M LSQBA251818T680K LSQBA251818T680M LSQBA251818T101K LSQBA251818T101M LSQBA251818T151K LSQBA251818T151M LSQBA251818T221K LSQBA251818T221M LSQBA251818T331K LSQBA251818T331M LSQBA251818T471K LSQBA251818T471M LSQBA251818T681K LSQBA251818T681M LSQBA251818T102K LSQBA251818T102M EHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS Nominal inductance [μH] 1.0 1.5 2.2 3.3 4.7 4.7 6.8 10 10 15 15 22 22 33 33 47 47 68 68 100 100 150 150 220 220 330 330 470 470 680 680 1000 1000 Inductance tolerance ±20% ±20% ±20% ±20% ±20% ±20% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% LSQB/LSQC series Rated Current : The maximum DC value having inductance decrease within 10 % and temperature increase within 20 degC by the application of DC bias. LSQE series Rated Current : The maximum DC value having inductance decrease within 20 % and temperature increase within 20 degC by the application of DC bias. ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . CATALOG 2022 i_wound_LB_S_e-E10R01 for General Electronic Equipment ■PART NUMBER New part number LSQCA251818T1R0M LSQCA251818T1R0MR LSQCA251818T1R5M LSQCA251818T2R2M LSQCA251818T3R3M LSQCA251818T4R7M LSQCA251818T6R8M LSQCA251818T100K LSQCA251818T100M LSQCA251818T150K LSQCA251818T150M LSQCA251818T220K LSQCA251818T220M LSQCA251818T330K LSQCA251818T330M LSQCA251818T470K LSQCA251818T470M LSQCA251818T680K LSQCA251818T680M LSQCA251818T101K LSQCA251818T101M LSQCA251818T151K LSQCA251818T151M LSQCA251818T221K LSQCA251818T221M LSQCA251818T331K LSQCA251818T331M LSQCA251818T471K LSQCA251818T471M LSQCA251818T681K LSQCA251818T681M New part number LSQEA251818T1R0M LSQEA251818T2R2M LSQEA251818T4R7M LSQEA251818T100K LSQEA251818T100M LSQEA251818T220K LSQEA251818T220M LSQEA251818T470K LSQEA251818T470M LSQEA251818T101K LSQEA251818T101M LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB Old part number (for reference) C2518T1R0M C2518T1R0MR C2518T1R5M C2518T2R2M C2518T3R3M C2518T4R7M C2518T6R8M C2518T100K C2518T100M C2518T150K C2518T150M C2518T220K C2518T220M C2518T330K C2518T330M C2518T470K C2518T470M C2518T680K C2518T680M C2518T101K C2518T101M C2518T151K C2518T151M C2518T221K C2518T221M C2518T331K C2518T331M C2518T471K C2518T471M C2518T681K C2518T681M Old part number (for reference) LB R2518T1R0M LB R2518T2R2M LB R2518T4R7M LB R2518T100K LB R2518T100M LB R2518T220K LB R2518T220M LB R2518T470K LB R2518T470M LB R2518T101K LB R2518T101M EHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS EHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS Nominal inductance [μH] 1.0 1.0 1.5 2.2 3.3 4.7 6.8 10 10 15 15 22 22 33 33 47 47 68 68 100 100 150 150 220 220 330 330 470 470 680 680 Nominal inductance [μH] 1.0 2.2 4.7 10 10 22 22 47 47 100 100 Inductance tolerance ±20% ±20% ±20% ±20% ±20% ±20% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% Inductance tolerance ±20% ±20% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% Self-resonant frequency [MHz](min.) 100 100 80 68 54 41 38 30 30 23 23 19 19 15 15 12 12 9.5 9.5 9.0 9.0 7.0 7.0 5.5 5.5 4.5 4.5 3.5 3.5 3.0 3.0 DC Resistance [Ω](±30%) 0.08 0.07 0.11 0.13 0.16 0.20 0.30 0.36 0.36 0.65 0.65 0.77 0.77 1.5 1.5 1.9 1.9 2.8 2.8 3.7 3.7 6.1 6.1 8.4 8.4 12.3 12.3 22 22 28 28 Rated current [mA](max.) 775 890 730 630 560 510 420 375 375 285 285 250 250 185 185 165 165 140 140 125 125 95 95 80 80 65 65 50 50 45 45 Measuring frequency [MHz] 7.96 7.96 7.96 7.96 7.96 7.96 7.96 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 Self-resonant frequency [MHz](min.) 100 68 45 30 30 19 19 11 11 9 9 DC Resistance [Ω](±30%) 0.045 0.07 0.10 0.19 0.19 0.44 0.44 0.84 0.84 1.89 1.89 Rated current [mA](max.) 960 480 345 235 235 175 175 120 120 80 80 Measuring frequency [MHz] 7.96 7.96 7.96 2.52 2.52 2.52 2.52 2.52 2.52 0.796 0.796 Self-resonant frequency [MHz](min.) 100 80 68 54 41 40 30 30 25 25 19 19 15 15 12 12 11 11 8.0 8.0 7.0 7.0 5.0 5.0 4.0 4.0 3.5 3.5 3.0 3.0 2.4 2.4 DC Resistance [Ω](±30%) 0.06 0.07 0.09 0.11 0.13 0.17 0.25 0.25 0.32 0.32 0.49 0.49 0.75 0.75 0.92 0.92 1.49 1.49 2.4 2.4 3.2 3.2 5.4 5.4 7.0 7.0 14 14 17 17 27 27 Rated current [mA](max.) 1,075 860 775 560 550 380 340 340 300 300 255 255 215 215 205 205 145 145 140 140 105 105 80 80 65 65 54 54 45 45 39 39 Measuring frequency [MHz] 7.96 7.96 7.96 7.96 7.96 7.96 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.796 0.252 0.252 ●3218(1207) type New part number LSQBA321818T1R0M LSQBA321818T1R5M LSQBA321818T2R2M LSQBA321818T3R3M LSQBA321818T4R7M LSQBA321818T6R8M LSQBA321818T100K LSQBA321818T100M LSQBA321818T150K LSQBA321818T150M LSQBA321818T220K LSQBA321818T220M LSQBA321818T330K LSQBA321818T330M LSQBA321818T470K LSQBA321818T470M LSQBA321818T680K LSQBA321818T680M LSQBA321818T101K LSQBA321818T101M LSQBA321818T151K LSQBA321818T151M LSQBA321818T221K LSQBA321818T221M LSQBA321818T331K LSQBA321818T331M LSQBA321818T471K LSQBA321818T471M LSQBA321818T681K LSQBA321818T681M LSQBA321818T102K LSQBA321818T102M LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB Old part number (for reference) 3218T1R0M 3218T1R5M 3218T2R2M 3218T3R3M 3218T4R7M 3218T6R8M 3218T100K 3218T100M 3218T150K 3218T150M 3218T220K 3218T220M 3218T330K 3218T330M 3218T470K 3218T470M 3218T680K 3218T680M 3218T101K 3218T101M 3218T151K 3218T151M 3218T221K 3218T221M 3218T331K 3218T331M 3218T471K 3218T471M 3218T681K 3218T681M 3218T102K 3218T102M EHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS Nominal inductance [μH] 1.0 1.5 2.2 3.3 4.7 6.8 10 10 15 15 22 22 33 33 47 47 68 68 100 100 150 150 220 220 330 330 470 470 680 680 1000 1000 Inductance tolerance ±20% ±20% ±20% ±20% ±20% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% LSQB/LSQC series Rated Current : The maximum DC value having inductance decrease within 10 % and temperature increase within 20 degC by the application of DC bias. LSQE series Rated Current : The maximum DC value having inductance decrease within 20 % and temperature increase within 20 degC by the application of DC bias. ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . CATALOG 2022 i_wound_LB_S_e-E10R01 for General Electronic Equipment ■PART NUMBER ●3225(1210) type New part number LSQCA322525T1R0MR LSQCA322525T1R5MR LSQCA322525T2R2MR LSQCA322525T3R3MR LSQCA322525T4R7MR LSQCA322525T6R8MR LSQCA322525T100KR LSQCA322525T100MR LSQCA322525T150KR LSQCA322525T150MR LSQCA322525T220KR LSQCA322525T220MR LSQCA322525T330KR LSQCA322525T330MR LSQCA322525T470KR LSQCA322525T470MR LSQCA322525T680KR LSQCA322525T680MR LSQCA322525T101KR LSQCA322525T101MR LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB LB Old part number (for reference) C3225T1R0MR C3225T1R5MR C3225T2R2MR C3225T3R3MR C3225T4R7MR C3225T6R8MR C3225T100KR C3225T100MR C3225T150KR C3225T150MR C3225T220KR C3225T220MR C3225T330KR C3225T330MR C3225T470KR C3225T470MR C3225T680KR C3225T680MR C3225T101KR C3225T101MR EHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS Nominal inductance [μH] 1.0 1.5 2.2 3.3 4.7 6.8 10 10 15 15 22 22 33 33 47 47 68 68 100 100 Inductance tolerance ±20% ±20% ±20% ±20% ±20% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% ±10% ±20% Self-resonant frequency [MHz](min.) 250 220 190 160 70 50 23 23 20 20 17 17 13 13 10 10 8 8 6 6 DC Resistance [Ω](±30%) 0.055 0.060 0.080 0.095 0.100 0.120 0.133 0.133 0.195 0.195 0.27 0.27 0.41 0.41 0.67 0.67 1.0 1.0 1.4 1.4 Rated current [mA](max.) 1,100 1,000 930 820 680 620 540 540 420 420 330 330 300 300 220 220 190 190 150 150 Measuring frequency [MHz] 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 LSQB/LSQC series Rated Current : The maximum DC value having inductance decrease within 10 % and temperature increase within 20 degC by the application of DC bias. LSQE series Rated Current : The maximum DC value having inductance decrease within 20 % and temperature increase within 20 degC by the application of DC bias. ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . CATALOG 2022 i_wound_LB_S_e-E10R01 Wire-wound Ferrite Inductors LSQB/LSQC/LSQE/LLQB/LLQC/LLQE/LMQB/LMQC/LMQE/ LBQB/LBQC/LBQE series Wire-wound Ferrite Power Inductors LSQN/LSQPA/LLQN/LLQPA/LMQN/LMQPA/ LBQN/LBQPA series Wire-wound Ferrite Inductors for Signal Lines LSQM/LLQM/LMQM/LBQM series ■PACKAGING ①Minimum Quantity Type A322525 A321818 A251818 B201616 A201616 A201212 A201209 A160808 B160808 Standard Quantity [pcs] Paper Tape Embossed Tape - 1000 - 2000 - 2000 - 2000 - 4000 4000 - 3000 - - 3000 ②Tape material ●Embossed tape ●Card board carrier tape ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . i_wound_CB_LB_pack_e-E10R01 ③Taping Dimensions ●Embossed Tape (0.315 inches wide) A B F Type B201616 A322525 A321818 A251818 A201616 A201212 B160808 1.75±0.1 (0.069±0.004) 8.0±0.3 (0.315±0.012) φ1.5+0.1/-0 (φ0.059+0.004/-0) 3.5±0.05 (0.138±0.002) Sprocket hole 4.0±0.1 (0.157±0.004) 2.0±0.1 (0.079±0.004) Chip cavity A B 1.75±0.1 2.1±0.1 (0.069±0.004) (0.083±0.004) 2.8±0.1 3.5±0.1 (0.110±0.004) (0.138±0.004) 2.1±0.1 3.5±0.1 (0.083±0.004) (0.138±0.004) 2.15±0.1 2.7±0.1 (0.085±0.004) (0.106±0.004) 1.75±0.1 2.1±0.1 (0.069±0.004) (0.083±0.004) 1.45±0.1 2.25±0.1 (0.057±0.004) (0.089±0.004) 1.1±0.1 1.9±0.1 (0.043±0.004) (0.075±0.004) Insertion pitch F 4.0±0.1 (0.157±0.004) 4.0±0.1 (0.157±0.004) 4.0±0.1 (0.157±0.004) 4.0±0.1 (0.157±0.004) 4.0±0.1 (0.157±0.004) 4.0±0.1 (0.157±0.004) 4.0±0.1 (0.157±0.004) Tape thickness T K 0.3±0.05 1.9max. (0.012±0.002) (0.075max.) 0.3±0.05 4.0max. (0.012±0.002) (0.157max.) 0.3±0.05 2.2max. (0.012±0.002) (0.087max.) 0.3±0.05 2.2max. (0.012±0.002) (0.087max.) 0.3±0.05 1.9max. (0.012±0.002) (0.075max.) 0.25±0.05 1.45max. (0.010±0.002) (0.057max.) 0.25±0.05 1.2max. (0.010±0.002) (0.047max.) Unit:mm(inch) Insertion pitch F 4.0±0.1 (0.157±0.004) 4.0±0.1 (0.157±0.004) Tape thickness T 1.1max. (0.043max.) 1.1max. (0.043max.) Unit:mm(inch) ●Card board carrier tape(0.315 inches wide) A B F Type A201209 A160808 1.75±0.1 (0.069±0.004) T 8.0±0.3 (0.315±0.012) φ1.5+0.1/-0 (φ0.059+0.004/-0) 3.5±0.05 (0.138±0.002) Sprocket hole 4.0±0.1 (0.157±0.004) 2.0±0.1 (0.079±0.004) Chip cavity A B 1.55±0.1 2.3±0.1 (0.061±0.004) (0.091±0.004) 1.0±0.1 1.8±0.1 (0.039±0.004) (0.071±0.004) ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . i_wound_CB_LB_pack_e-E10R01 ④Leader and Blank Portion ⑤Reel Size ⑥Top Tape Strength The top tape requires a peel-off force 0.1 to 1.0N in the direction of the arrow as illustrated below. ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . i_wound_CB_LB_pack_e-E10R01 Wire-wound Ferrite Inductors LSQB/LSQC/LSQE series for General Electronic Equipment for Consumer Wire-wound Ferrite Power Inductors LSQN/LSQPA series for General Electronic Equipment for Consumer Wire-wound Ferrite Inductors for Signal Lines LSQM series for General Electronic Equipment for Consumer Wire-wound Ferrite Inductors LLQB/LLQC/LLQE series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II) Wire-wound Ferrite Power Inductors LLQN/LLQPA series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II) Wire-wound Ferrite Inductors for Signal Lines LLQM series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II) ■RELIABILITY DATA 1.Operating temperature Range Specified Value -40~+105℃(Including self-generated heat) 2. Storage Temperature Range(after soldering) Specified Value -40~+85℃ Test Methods and Remarks Wire-wound Ferrite Inductors, Wire-wound Ferrite Power Inductors Please refer the term of "7. storage conditions" in precautions. 3.Rated Current Specified Value Within the specified tolerance 4.Inductance Specified Value Within the specified tolerance Test Methods and Remarks Measuring equipment Measuring frequency : :LCR Mater(HP4285A or its equivalent) Specified frequency 5.Q Specified Value Test Methods and Remarks Wire-wound Ferrite Inductors for Signal Lines: Within the specified tolerance Wire-wound Ferrite Inductors for Signal Lines: Measuring equipment : LCR Mater(HP4285A or its equivalent) Measuring frequency : Specified frequency 6.DC Resisitance Specified Value Within the specified tolerance Test Methods and Remarks Measuring equipment : DC Ohmmeter (HIOKI 3227 or its equivalent) 7.Self-Resonant Frequency Specified Value Within the specified tolerance Test Methods and Remarks Measuring equipment : Impedance analyzer (HP4291A or its equivalent) ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . i_wound_CB_LB_S_L_reli_e-E10R01 8.Temperature Characteristic LSQMB2016 Inductance change : Within±5% LLQMB2016 Specified Value Test Methods and Remarks LSQBA1608 LSQBA2012 LSQEA2012 LSQNA2012 LSQNA2012 LSQBA2016 LSQNA2016 LSQBA2518 LSQEA2518 LSQNA2518 LSQCA3225 LSQPA3225 LLQBA2016 LLQNA2012 LLQEA2518 LLQBA2012 LLQBA2016 LLQNA2518 LLQEA2012 LLQNA2016 LLQCA3225 LLQNA2012 LLQBA2518 LLQPA3225 LSQBB1608 LSQNB1608 LSQCA2016 LSQPA2016 LSQCA2518 LSQPA2518 LSQBA3218 LLQBB1608 LLQCA2518 LLQNB1608 LLQPA2518 LLQCA2016 LLQBA3218 LSQCA2012 LSQPA2012 LLQCA2012 LLQPA2012 Inductance change : Within±20% Inductance change : Within±25% LLQPA2016 Inductance change : Within±35% Based on the inductance at 20℃ and Measured at the ambient of -40℃~+85℃. 9.Rasistance to Flexure of Substrate Specified Value No damage. Warp : 2mm Test substrate : Glass epoxy-resin substrate Thickness : 1.0mm (1608 type:0.8mm) Test Methods and Remarks 10.Body Strength Specified Value No damage. Test Methods and Remarks Applied force Duration : 10N(1608 type:5N) : 10sec. 11.Adhesion of terminal electrode LB, LBC, LBR, LBMF Series Specified Value CB, CBC, CBL, CBMF Series No abnormality. LBM Series Test Methods and Remarks Applied force Duration Test substrate : 10N to X and Y directions(1608 type:5N to X and Y directions) : 5 sec. : Printed board ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . i_wound_CB_LB_S_L_reli_e-E10R01 12.Resistance to vibration Specified Value Test Methods and Remarks Wire-wound Ferrite Inductors, Wire-wound Ferrite Power Inductors Inductance change : Within±10% No significant abnormality in appearance. Wire-wound Ferrite Inductors for Signal Lines Inductance change :Within±5% No significant abnormality in appearance. The given sample is soldered to the board and then it is tested depending on the conditions of the following table. Vibration Frequency 10~55Hz Total Amplitude 1.5mm (May not exceed acceleration 196m/s2) Sweeping Method 10Hz to 55Hz to 10Hz for 1min. X Time Y For 2 hours on each X, Y, and Z axis. Z Recovery : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. 13.Drop test Specified Value - 14.Solderability Specified Value At least 90% of surface of terminal electrode is covered by new Test Methods and Remarks Solder temperature Duration Flux : 245±5℃ : 5±0.5sec : Ethanol solution with 25% of colophony 15.Resistance to soldering Specified Value Wire-wound Ferrite Inductors, Wire-wound Ferrite Power Inductors Inductance change : Within±10% Wire-wound Ferrite Inductors for Signal Lines Inductance change :Within±5% Test Methods and Remarks 3 times of reflow oven at 230℃ MIN for 40sec. with peak temperature at 260 ℃ for 5sec. Recovery : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. 16.Resisitance to solvent Specified Value - Test Methods and Remarks Solvent temperature Type of solvent Cleaning conditions : Room temperature : Isopropyl alcohol : 90s. Immersion and cleaning. 17.Thermal shock Specified Value Test Methods and Remarks Inductance change : Within±10% No significant abnormality in appearance. The given sample is soldered to the board and then its Inductance is measured after 100cycles of the following conditions. Conditions of 1 cycle Step Temperature (℃) Duration (min) 1 -40±3 30±3 2 Room temperature Within 3 3 +85±2 30±3 4 Room temperature Within 3 Recovery : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. 18.Damp heat life test Specified Value Inductance change : Within±10% No significant abnormality in appearance. Test Methods and Remarks Temperature Humidity Duration Recovery : 60±2℃ : 90~95%RH : 1000 hrs : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . i_wound_CB_LB_S_L_reli_e-E10R01 19.Loading under damp heat life test Inductance change : Within±10% No significant abnormality in appearance. Specified Value Test Methods and Remarks Temperature Humidity Duration Applied current Recovery : 60±2℃ : 90~95%RH : 1000 hrs : Rated current : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. 20.High temperature life test Specified Value Wire-wound Ferrite Power Inductors, Wire-wound Ferrite Inductors for Signal Lines : Inductance change : Within±10% No significant abnormality in appearance. Test Methods and Remarks Temperature Duration Recovery : 85±2℃ : 1000 hrs : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. 21.Loading at high temperature life test Specified Value Wire-wound Ferrite Inductors: Inductance change : Within±10% (3225 type:Within±20%) No significant abnormality in appearance. Test Methods and Remarks Temperature Duration Applied current Recovery : 85±2℃ : 1000 hrs : Rated current : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. 22.Low temperature life test Specified Value Inductance change : Within±10% No significant abnormality in appearance. Test Methods and Remarks Temperature Duration Recovery : -40±2℃ : 1000 hrs : At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs. 23.Standard condition Specified Value Standard test conditions Unless specified, Ambient temperature is 20±15℃ and the Relative humidity is 65±20%. If there is any doubt about the test results, further measurement shall be had within the following limits: Ambient Temperature: 20±2℃ Relative humidity: 65±5% Inductance value is based on our standard measurement systems. ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . i_wound_CB_LB_S_L_reli_e-E10R01 Wire-wound Ferrite Inductors LSQB/LSQC/LSQE/LLQB/LLQC/LLQE/LMQB/LMQC/LMQE/ LBQB/LBQC/LBQE series Wire-wound Ferrite Power Inductors LSQN/LSQPA/LLQN/LLQPA/LMQN/LMQPA/ LBQN/LBQPA series Wire-wound Ferrite Inductors for Signal Lines LSQM/LLQM/LMQM/LBQM series ■PRECAUTIONS 1.Circuit Design Precautions ◆Verification of operating environment, electrical rating and performance 1. A malfunction in medical equipment, spacecraft, nuclear reactors, etc. may cause serious harm to human life or have severe social ramifications. As such, any inductors to be used in such equipment may require higher safety and/or reliability considerations and should be clearly differentiated from components used in general purpose applications. 2. When inductors are used in places where dew condensation develops and/or where corrosive gas such as hydrogen sulfide, sulfurous acid, or chlorine exists in the air, characteristic deterioration may occur. Please do not use inductors under such environmental conditions. ◆Operating Current (Verification of Rated current) 1. The operating current including inrush current for inductors must always be lower than their rated values. 2. Do not apply current in excess of the rated value because the inductance may be reduced due to the magnetic saturation effect. ◆Temperature rise Temperature rise of power choke coil depends on the installation condition in end products. Make sure that temperature rise of power choke coils in actual end products is within the specified temperature range. 2.PCB Design Precautions Technical considerations ◆Land pattern design 1. Please contact any of our offices for a land pattern, and refer to a recommended land pattern of a right figure or specifications. PRECAUTIONS 【Recommended Land Patterns】 Surface Mounting ・ Mounting and soldering conditions should be checked beforehand. ・ Applicable soldering process to those products is reflow soldering only. 3.Considerations for automatic placement Precautions Technical considerations ◆Adjustment of mounting machine 1. Excessive impact load should not be imposed on the products when mounting onto the PC boards. 2. Mounting and soldering conditions should be checked beforehand. 1. When installing products, care should be taken not to apply distortion stress as it may deform the products. 4.Soldering Precautions ◆Reflow soldering(Wire-wound Ferrite Inductors, Wire-wound Ferrite Power Inductors) 1. For reflow soldering with either leaded or lead-free solder, the profile specified in "point for controlling" is recommended. ◆Recommended conditions for using a soldering iron 1. Put the soldering iron on the land-pattern. Soldering iron's temperature - Below 350℃ Duration-3 seconds or less. The soldering iron should not come in contact with inductor directly. ◆Reflow soldering(Wire-wound Ferrite Inductors, Wire-wound Ferrite Power Inductors) 1. Reflow profile Technical considerations ◆Recommended conditions for using a soldering iron 1. Components can be damaged by excessive heat where soldering conditions exceed the specified range. ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . i_wound_CB_LB_prec_e-E10R01 5.Cleaning Precautions Technical considerations ◆Cleaning conditions Washing by supersonic waves shall be avoided. ◆Cleaning conditions If washed by supersonic waves, the products might be broken. 6.Handling Precautions Technical considerations ◆Handling 1. Keep the inductors away from all magnets and magnetic objects. ◆Breakaway PC boards( splitting along perforations) 1. When splitting the PC board after mounting inductors, care should be taken not to give any stresses of deflection or twisting to the board. 2. Board separation should not be done manually, but by using the appropriate devices. ◆Mechanical considerations 1. Please do not give the inductors any excessive mechanical shocks. ◆Handling 1. There is a case that a characteristic varies with magnetic influence. ◆Breakaway PC boards( splitting along perforations) 1. Planning pattern configurations and the position of products should be carefully performed to minimize stress. ◆Mechanical considerations 1. There is a case to be damaged by a mechanical shock. 7.Storage conditions Precautions ◆Storage 1. To maintain the solderability of terminal electrodes and to keep the packing material in good condition, temperature and humidity in the storage area should be controlled. ・ Recommended conditions Ambient temperature : 0~40℃ Humidity : Below 70% RH ・ The ambient temperature must be kept below 30℃. Even under ideal storage conditions, solderability of products electrodes may decrease as time passes. For this reason, product should be used within 6 months from the time of delivery. In case of storage over 6 months, solderability shall be checked before actual usage. Technical considerations ◆Storage 1. Under a high temperature and humidity environment, problems such as reduced solderability caused by oxidation of terminal electrodes and deterioration of taping/packaging materials may take place. ▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) . i_wound_CB_LB_prec_e-E10R01
LSQBB160808T100K 价格&库存

很抱歉,暂时无法提供与“LSQBB160808T100K”相匹配的价格&库存,您可以联系我们找货

免费人工找货
LSQBB160808T100K
  •  国内价格
  • 5+0.51998
  • 50+0.42710
  • 150+0.38066
  • 500+0.34583

库存:0

LSQBB160808T100K
    •  国内价格
    • 3000+0.62846
    • 9000+0.61098

    库存:0