TLF9UA502WR32

TLF9UA502WR32

  • 厂商:

    TAIYO-YUDEN(太诱)

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
TLF9UA502WR32 数据手册
Notice for TAIYO YUDEN products  1 Please read this notice before using the TAIYO YUDEN products. ■ Product information in this catalog is as of October 2008. All of the contents specified herein are subject to change without notice due to technical improvements, etc. Therefore, please check for the latest information carefully before practical application or usage of the Products. Please note that Taiyo Yuden Co., Ltd. shall not be responsible for any defects in products or equipment incorporating such products, which are caused under the conditions other than those specified in this catalog or individual specification. INFORMATION ON THE GENERAL CATALOG REMINDERS ■ Please contact Taiyo Yuden Co., Ltd. for further details of product specifications as the individual specification is available. ■ Please conduct validation and verification of products in actual condition of mounting and operating environment before commercial shipment of the equipment. ■ All electronic components or functional modules listed in this catalog are developed, designed and intended for use in general electronics equipment.(for AV, office automation, household, office supply, information service, telecommunications, (such as mobile phone or PC) etc.). Before incorporating the components or devices into any equipment in the field such as transportation,( automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network (telephone exchange, base station) etc. which may have direct influence to harm or injure a human body, please contact Taiyo Yuden Co., Ltd. for more detail in advance. Do not incorporate the products into any equipment in fields such as aerospace, aviation, nuclear control, submarine system, military, etc. where higher safety and reliability are especially required. In addition, even electronic components or functional modules that are used for the general electronic equipment, if the equipment or the electric circuit require high safety or reliability function or performances, a sufficient reliability evaluation check for safety shall be performed before commercial shipment and moreover, due consideration to install a protective circuit is strongly recommended at customer's design stage. ■ The contents of this catalog are applicable to the products which are purchased from our sales offices or distributors (so called“TAIYO YUDEN’s official sales channel”). It is only applicable to the products purchased from any of TAIYO YUDEN’s official sales channel. ■ Please note that Taiyo Yuden Co., Ltd. shall have no responsibility for any controversies or disputes that may occur in connection with a third party's intellectual property rights and other related rights arising from your usage of products in this catalog. Taiyo Yuden Co., Ltd. grants no license for such rights. ■ Caution for export Certain items in this catalog may require specific procedures for export according to“Foreign Exchange and Foreign Trade Control Law”of Japan,“U.S. Export Administration Regulations” , and other applicable regulations. Should you have any question or inquiry on this matter, please contact our sales staff. Should you have any question or inquiry on this matter, please contact our sales staff. ! 当社カタログをご使用の際には 「当社製品に関するお断り」を必ずお読みください。 △ 9 ! Please read the "Notice for TAIYO YUDEN products" before using this catalog. △ 3 コモンモードチョークコイル (ACライン用) リードタイプ COMMON MODE CHOKE COILS (FOR AC LINES) LEADED TYPE OPERATING 等価回路(Equivalent circuit) TEMP. TLF9UAタイプ:ー25∼+115℃ TLF14CBタイプ:ー20∼+105℃ TLF25RAタイプ:ー25∼+105℃ (製品自己発熱を含む) (Including self-generated heat) 特長 FEATURES ・TLF 9UA(H)タイプ ………………………………………………… 小型形状 ・TLF14CB(H)タイプ ………………………………………………… 普通形状 ・TLF25RA タイプ ………………………………………………… 大電流容量 ・TLF 9UA(H)TYPE ............................................ Small-sized configuration ・TLF14CB(H)TYPE ................................................ Ordinary configuration ・TLF25RA TYPE ............. Large current capacity for power supply line use 用途 APPLICATIONS TV、VTR、SW電源,NCマシン、コンピュータおよび周辺機器,各種計測器、 各種制御装置などの雑音端子電圧、電源ラインノイズ対策 ・TLF 9UA(H)TYPE ………………………………………… 小電力用の機器 ・TLF14CB(H)TYPE …………………………… 入力電力数10W の機器 ・TLF25RA TYPE ……………………………………………… 高電力用の機器 As a preventive measure against noise terminal voltage or power supply noise in TV or VTR units, SW power supplies, NC machines, computer systems, peripheral units, measuring instruments, and controllers. ・TLF 9UA(H)Type ............................................... low-current applications ・TLF14CB(H)Types ...........equipment with several tens of watts of input power ・TLF25RA Type ....................................................high-current applications 形名表記法 ORDERING CODE 1 3 4 5 6 形式 形状 公称インダクタンス(μH) インダクタンス許容差(%) 定格電流(A) TLF ラインフィルタ 2 RA△ UA△ UAH CB△  CBH コア寸法(mm) △9 14 25 リングコア縦形 U字コア縦形 U字コア横形 □字コア分割巻縦型 □字コア分割巻横型 △=スペース 例 102 103 △ W 1000 10000 公称値以上 ± 100 10 △=スペース R54 0R8 R=小数点 0.54 0.8 7 8 製品区分記号 当社管理記号 △ 9 14 25 △=スペース △ 一般 △=スペース 標準品 △=スペース T L F △ 9 U A H 1 0 2 W 0 R 8 ○ ○ 1 7 6 8 1 3 4 5 6 Type  Shape  Nominal Inductance(μH) Inductance tolerance(%) Rated current(A) TLF Line filter Core dimensions(mm) △9 14 25 RA△ UA△ UAH CB△  CBH 2 386 5 4 3 2 9 14 25 △=Blank space Ring core, vertical type U core, vertical type U core, horizontal type Square type core vertically split wound Square type core horizontally split wound △=Blank space ! 当社カタログをご使用の際には 「当社製品に関するお断り」を必ずお読みください。 △ example 102 103 △ W 1000 10000 Nominal Values or higher ±100 10 △=Blank space R54 0R8 0.54 0.8 R=decimal point 7 8 Product classification code Internal code △ Standard △=Blank space △ Standard Product △=Blank space ! Please read the "Notice for TAIYO YUDEN products" before using this catalog. △ 外形寸法 EXTERNAL DIMENSIONS TLF14CB Type TLF14CBH Type TLF25RA Type 5 〔 〕参考値 TLF9UA H Type (0.177±0.039) TLF9UA Type FERRITE PRODUCTS 〔 〕Reference Values unit:mm(inch) セレクションガイド Selection Guide P.14 etc アイテム一覧 Part Numbers 特性図 Electrical Characteristics P.388 ! 当社カタログをご使用の際には 「当社製品に関するお断り」を必ずお読みください。 △ P.389 梱包 Packaging P.389 信頼性 Reliability Data P.400 使用上の注意 Precautions P.408 ! Please read the "Notice for TAIYO YUDEN products" before using this catalog. △ 387 アイテム一覧 PART NUMBERS Type 形  名 Ordering code TLF9UA TLF9UAH TLF14CB TLF14CBH TLF25RA 388 TLF 9UA 102W0R8 TLF 9UA 202WR54 TLF 9UA 302WR42 TLF 9UA 502WR32 TLF 9UA 802WR25 TLF 9UA 103WR23 TLF 9UAH 102W0R8 TLF 9UAH 202WR54 TLF 9UAH 302WR42 TLF 9UAH 502WR32 TLF 9UAH 802WR25 TLF 9UAH 103WR23 TLF14CB 102 1R5 TLF14CB 222 1R2 TLF14CB 332 1R0 TLF14CB 472 1R0 TLF14CB 562 0R8 TLF14CB 682 0R8 TLF14CB 103 0R7 TLF14CB 223 0R4 TLF14CB 333 0R3 TLF14CB 473 0R2 TLF14CB 563 0R2 TLF14CB 683 0R2 TLF14CBH 102 1R5 TLF14CBH 222 1R2 TLF14CBH 332 1R0 TLF14CBH 472 1R0 TLF14CBH 562 0R8 TLF14CBH 682 0R8 TLF14CBH 103 0R7 TLF14CBH 223 0R4 TLF14CBH 333 0R3 TLF14CBH 473 0R2 TLF14CBH 563 0R2 TLF14CBH 683 0R2 TLF25RA 102W9R0 TLF25RA 202W5R5 TLF25RA 302W5R0 TLF25RA 502W5R0 TLF25RA 802W3R5 TLF25RA 103W2R5 インダクタンス 耐電圧[V] 適用周波数[MHz] EHS 直流抵抗[Ω] 定格電流[A] 定格電圧[V] インダクタンス Withstanding Applicable (Environmental 許容差 DC resistance Rated current Rated voltage [mH] voltage frequency Hazardous Inductance 参考値 [1 minute] (max) (max) (max) Inductance Substances) Tolerance Reference Value (min) RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS ! 当社カタログをご使用の際には 「当社製品に関するお断り」を必ずお読みください。 △ 1 2 3 5 8 10 1 2 3 5 8 10 1.0 2.2 3.3 4.7 5.6 6.8 10 22 33 47 56 68 1.0 2.2 3.3 4.7 5.6 6.8 10 22 33 47 56 68 1 2 3 5 8 10 +100%/ー10% +100%/ー10% +100%/ー10% +100%/ー10% +100%/ー10% +100%/ー10% +100%/ー10% +100%/ー10% +100%/ー10% +100%/ー10% +100%/ー10% +100%/ー10% min min min min min min min min min min min min min min min min min min min min min min min min +100%/ー10% +100%/ー10% +100%/ー10% +100%/ー10% +100%/ー10% +100%/ー10% 0.5 1.0 1.5 2.5 4.0 4.5 0.5 1.0 1.5 2.5 4.0 4.5 0.1 0.18 0.32 0.38 0.42 0.6 0.85 1.7 2.7 3.6 5 6.5 0.1 0.18 0.32 0.38 0.42 0.6 0.85 1.7 2.7 3.6 5 6.5 0.03 0.05 0.06 0.07 0.11 0.17 0.80 0.54 0.42 0.32 0.25 0.23 0.80 0.54 0.42 0.32 0.25 0.23 1.5 1.2 1.0 1.0 0.8 0.8 0.7 0.4 0.3 0.2 0.2 0.2 1.5 1.2 1.0 1.0 0.8 0.8 0.7 0.4 0.3 0.2 0.2 0.2 9.0 5.5 5.0 5.0 3.5 2.5 0.1∼10 AC250 AC2000 0.1∼20 ! Please read the "Notice for TAIYO YUDEN products" before using this catalog. △ インピーダンス―周波数特性 IMPEDANCE-FREQUENCY CHARACTERISTIC TLF14CB/TLF14CBH Type TLF9UA/TLF9UAH Type TLF25RA Type 5 FERRITE PRODUCTS 梱包 PACKAGING 最小受注単位数 Minimum Quantity CM / BU Type 最小受注単位数(pcs.) Type CM05RA06 Minimum Quantity 箱づめ 袋づめ Box Bulk ̶ 500 CM05RB□□ 1000 ̶ CM08RA□□ ̶ 250 CM08RB□□ 500 ̶ CM12RA02 ̶ 100 BU08RA□□ ̶ 200 TLF Type 最小受注単位数(pcs.) Type Minimum Quantity 箱づめ Box TLF9UA□ 500 TLF9UB□ 500 TLF14CB□ 500 TLF25RA 200 ! 当社カタログをご使用の際には 「当社製品に関するお断り」を必ずお読みください。 △ ! Please read the "Notice for TAIYO YUDEN products" before using this catalog. △ 389 1/4 RELIABILITY DATA  Specified Value Item 1.Operating Temperature CMーRA/ BUーRA Type CMーRB Type ー25∼+105℃ Range TLF9U TLF14CB TLF9U:ー25∼+115℃ Test method and remarks TLF25RA ー25∼+105℃ Including temperature rise due to selfーgenerated heat. TLF14CB:ー20∼+105℃ 2.Storage temperature range ー40∼+85℃ 3.Rated current Within the specifed range CM: The maximum DC value having temperature increase within specified temperature, as detailed in individual TLF9UA, 14CB, 25RA: The maximum AC value having temperature increase within 45℃ by the application of AC current. TLF9UB: The maximum DC value having temperature increase within 45℃ by the application of DC current. 4.Inductance Within the specifed tolerance CM: Measuring equipmet:4262A(HP)or its equivalent 5 FERRITE PRODUCTS specification. Measuring frequency:1kHz TLF9U, 25RA: Measuring equipment:Impedance analyzer(HP4192A) or its equivalent Measuring frequency:1kHz Measuring voltage:0.35Vosc TLF14CB: Measuring equipment:LCR meter 4284A or its equivalent Measuring frequency:1kHz Measuring voltage:1.0V 5.DC resistance Within the specifed tolerance 6.Terminal strength No abnormality CM, TLF: Measuring equipment:DC ohmmeter CM: Fix the component in the direction to draw terminal tensile force and gradually apply tensile force as detailed in indiviual specifications. TLF9U: Apply the stated tensile force gradually in the direction to draw terminal. Nominal wire diameter tensile φd force 〔mm〕 〔N〕 〔S〕 φ0.6 5 30±5 duration TLF14CB: Apply the stated tensile force gradually in the direction to draw terminal. Nominal wire diameter tensile φd force 〔mm〕 〔N〕 〔S〕 φ0.8 10 30±5 duration TLF25RA: Apply the tensile force of 10N in the direction to draw terminal for 5 seconds. 7.Temperature rise Refer to individual specification 45℃ max. TLF: Resistance substitution method Applied current:Rated current Duration:1 hr 8.Insulation resistance 100MΩmin. CM・TLF: Applied voltage:Rated voltage(CMーRA/BUーRA、CMーRB) between wires :500VDC(TLF9UA、14CB、25RA) :250VDC(TLF 9UB) Duration:60sec. 9.Insulation resistance between wire and core 100MΩmin. TLF: Applied voltage:500VDC(TLF9UA、14CB) :250VDC(TLF 9UB) Duration:60 sec. ! 当社カタログをご使用の際には 「当社製品に関するお断り」を必ずお読みください。 △ ! Please read the "Notice for TAIYO YUDEN products" before using this catalog. △ 401 2/4 RELIABILITY DATA  Specified Value Item 10.Withstanding: CMーRA/ BUーRA Type TLF9U TLF14CB CMーRB Type Test method and remarks TLF25RA CM・TLF: No abnormality Applied voltage:250VDC(CMーRA/BUーRA、CMーRB) between wires :2000VAC(TLF9UA、14CB、25RA) :500VDC(TLF 9UB) Duration:60sec. TLF: No abnormality 11.Withstanding: Applied voltage:2000VAC(TLF9UA、14CB) between wires and core 12.Rated voltage Within the specified range TLF9UA, 14CB, 25RA:250VAC TLF9UB:50VDC 13.Resistance to vibration Appearance: TLF9U CM,TLF: No abnormality Inductance change: According to JIS C0040 Inductance change: Within±5% Direction:2hrs each in X, Y and Z direction Total:6hrs Frequency range:10 to 55 to 10Hz(1 min.) Within±15% TLF14CB Amplitude:1.5mm(shall not exceed acceleration 196m2/s) Within the specified Mounting method:soldering onto PC board range Recovery:2 to 24 hrs of recovery under the standard FERRITE PRODUCTS :500VDC(TLF9UB) Duration:60sec. 5 condition after the test.(CMーRB) : At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the measurement within 2hrs.(TLF9U、14CB) 14.Solderability At least 75% of terminal electrode is covered by Solder shall be uniformly adhered onto im- CM: new solder. mersed surfaces. Solder temperature:235±5℃ Duration:2±0.5sec. Immersion depth:According to detailed specification. TLF: Solder temperature:230±5℃ Duration:2±0.5sec.(9U、25RA) :3±0.5sec.(14CB) Immersion depth:Up to 1.0 to 1.5mm from PBC mounted level. 15.Resistance to soldering heat Appearance:No abnormality TLF9UA・TLF25RA: Impedance change : Refer to individual specifi- Inductance change:Within±5% cation CM: Solder temperature:260±5℃ Duration:5±0.5sec. TLF14CB Immersion depth:Up to 2∼2.5mm from terminal root. Within the specified range Recovery:1 to 2 hrs of recovery under the standard condition after the test. TLF: Solder temperature:260±5℃ Duration:5±1sec.(25RA) :10±1sec.(9U、14CB) Immersion depth:Up to 1.0 to 1.5mm from PBC mounted level. Recovery : At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the measurement within 2hrs. ! 当社カタログをご使用の際には 「当社製品に関するお断り」を必ずお読みください。 △ ! Please read the "Notice for TAIYO YUDEN products" before using this catalog. △ 403 3/4 RELIABILITY DATA   Specified Value Item 16.Thermnal shock CMーRA/ BUーRA Type CMーRB Type TLF9U TLF14CB Test method and remarks TLF25RA Appearance:No abnormality TLF9UA・TLF25RA: CM, TLF: Impedance change : Refer to individual specifi- Inductance change:Within±15% According to JIS C0025 Conditions for 1 cycle cation Step Temperature〔℃〕 ・Withstanding voltage:No abnormality 1 ー25±3 ・Insulation resistance:No abnormality 2 TLF14CB: Duration〔min〕 Room Temperature +85±2 3 Room Temperature 30±3 Within 3 Number of cycles:10 Recovery : At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the measurement within 2 hrs. 17.Damp heat TLF9UA・TLF25RA: TLF: Inductance change:Within±15% Temperature:60±2℃ 5 FERRITE PRODUCTS 4 30±3 Within 3 ※TLF14CB Temperature:40±2℃ TLF14CB: Humidity:90∼95%RH Withstanding voltage:No abnormality Duration:500 hrs Insulation resistance:No abnormality Recovery : At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs. 18. Loading under damp heat Appearance:No abnormality Withstanding voltage:No abnormality CM: Inductance change : Refer to individual specifi- Insulation resistance:No abnormality Temperature:40±2℃ cation Humidity:90∼95%RH Duration:500(+12, ー0)hrs Applied current:Rated current Recovery:1 to 2hrs of recovery under the standard condition after the removal from test chamber. TLF: Temperature:60±2℃ ※TLF14CB Temperature:40±2℃ Humidity:90∼95%RH Duration:100 hrs Applied voltage : Apply the following specified voltage between windings. TLF9UA、25RA 250VAC TLF9UB 50VDC ※TLF14CB Duration : 500 hrs Apply rated current across windings Recovery : At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs. 19.Loading at high temperature Withstanding voltage : No abnormality Insula- TLF: tion resistance:No abnormality Temperature:85±2℃ Duration:100 hrs Applied voltage : Apply the following specified voltage between windings. TLF9UA、25RA 250VAC TLF9UB 50VDC ※TLF14CB Duration:500 hrs Apply rated current across windings Recovery : At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs. ! 当社カタログをご使用の際には 「当社製品に関するお断り」を必ずお読みください。 △ ! Please read the "Notice for TAIYO YUDEN products" before using this catalog. △ 405 4/4 RELIABILITY DATA Specified Value Item 20.Low temperature life test CMーRA/ BUーRA Type CMーRB Type Appearance:No abnormality TLF9U TLF14CB Test method and remarks TLF25RA TLF9U・TLF25RA: Inductance change : Refer to individual specifi- Inductance change:Within±15% CM: Temperature:ー40±3℃ Duration:500(+12, ー0)hrs cation TLF14CB: Recovery:1 to 2hrs of recovery under the standard con- ・Withstanding voltage:No abnormality dition after the removal from test chamber. (CMーRA) ・Insulation resistance:No abnormality : 1 to 2hrs of recovery under the standard con- TLF: Temperature:ー25±2℃ ※TLF14CB Temperature:ー40±2℃ Duration:500 hrs Recovery : At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs. 21.High Temperature life test Appearance:No abnormality TLF9U・TLF25RA: CM: Inductance change : Refer to individual specifi- Inductance change:Within±15% Temperature:85±2℃ TLF14CB: Recovery:1 to 2hrs of recovery under the standard con- FERRITE PRODUCTS dition after the removal from test chamber. (CMーRB) 5 Duration:500(+12, ー0)hrs cation ・Withstanding voltage:No abnormality dition after the removal from test chamber. ・Insulation resistance:No abnormality (CMーRA) :1 to 2hrs of recovery under the standard condition after the removal from test chamber. (CMーRB) TLF: Temperature:85±2℃ ※TLF14CB Temperature:105±3℃ Duration:500 hrs Recovery : At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs. ! 当社カタログをご使用の際には 「当社製品に関するお断り」を必ずお読みください。 △ ! Please read the "Notice for TAIYO YUDEN products" before using this catalog. △ 407 PRECAUTIONS CM-RA Type, CM-RB Type, TLF Type Stages 1.Circuit Design Precautions Technical considerations Operating environment, 1.The products described in this specification are intended for use in general equipment, electronic equipment, (office telecommunications systems, supply measuring . They are not equipment, and household equipment) intended for use in mission-critical equipment or systems requiring special quality and high reliability(traffic systems, 5 safety equipment, aerospace systems, nuclear control systems and medical equipment including life-support injury or damage. For such uses, contact TAIYO YUDEN Sales Department in advance. 2.PCB Design 1.When Inductors are mounted onto a PC board, hole dimensions on the board should Design 1.Please design insertion pitches of a base in the pitches that fitted a terminal interval. match the lead pitch of the component, if not, it will cause breakage of the terminals or cracking of terminal roots covered with resin as excess stress travels through the terminal legs. 3.Soldering Wave soldering 1.Please refer to the specifications in the catalog for a wave soldering. FERRITE PRODUCTS systems,)where product failure might result in loss of life, 2.Do not immerse the entire Inductors in the flux during the soldering operation. Lead free soldering 1.When using products with lead free soldering, we request to use them after confirming of adhesion, temperature of 1.If products are used beyond the range of the recommended conditions, heat stresses may deform the products, and consequently degrade the reliability of the products. resistance to soldering heat, etc. sufficiently. Recommended conditions for using a soldering iron Put the soldering iron on the land-pattern. Soldering iron's temperature - Below 350 ℃ Duration - 3 seconds or less The soldering iron should not directly touch the product. 4.Cleaning Cleaning conditions 1.TLF type Please contact any of our offices for about a cleaning, 5.Handling Handling 1.Keep the product away from all magnets and magnetic 1.There is a case that a characteristic varies with magnetic influence. objects. Mechanical considerations 1.Please do not give the product any excessive mechanical 1.There is a case to be damaged by a mechanical shock. shocks. 2.TLF type 2.TLF type Please do not add any shock or and power to a product in There is a case to be broken by a fall. transportation. Packing 1.Please do not give the product any excessive mechanical 1.There is a case that a lead route turns at by a fall or an excessive shock. shocks. In loading, please pay attention to handling indication mentioned in a packing box(a loading direction / number of maximum loading / fragile item) . 6.Storage conditions Storage 1.To maintain the solderability of terminal electrodes and to 1. Under a high temperature and humidity environment, problems such as reduced keep the packing material in good condition, temperature solderability caused by oxidation of terminal electrodes and deterioration of and humidity in the storage area should be controlled. taping/packaging materials may take place. ・Recommended conditions  Ambient temperature      0∼40℃  Humidity  Below 70% RH The ambient temperature must be kept below 30℃. Even under ideal storage conditions, solderability of products electrodes may decrease as time passes. For this reason, product should be used within one year from the time of delivery. In case of storage over 6 months, solderability shall be checked before actual usage. ! 当社カタログをご使用の際には 「当社製品に関するお断り」を必ずお読みください。 △ ! Please read the "Notice for TAIYO YUDEN products" before using this catalog. △ 409
TLF9UA502WR32 价格&库存

很抱歉,暂时无法提供与“TLF9UA502WR32”相匹配的价格&库存,您可以联系我们找货

免费人工找货