AC1050 • 50 Amp Current Transformer
Low Cost 50/60Hz Current Transformers
Applications • Sensing Overload Current • Ground fault detection • Metering • Analog to Digital Circuits • Competitive pricing due to high volume production • Manufactured in an ISO-9001:2000, TS-16949:2002 and ISO-14001:2004 certified Talema facility • Fully RoHS compliant
Electrical Specifications @ 20°C ambient
E lectrical S p ecificatio n s Primary Current 50A nom., 125A max. Turns Ratio 1000:1 nominal Volt per Amp Ratio at 50A for 100 ohm load 0.100 V/A Volt per Amp Ratio at 5A for 100 ohm load 0.098 V/A DC Resistance at 20°C 49.3 ohms Dielectric Withstanding Voltage (Hi-pot) 4KVrms Mechanical Specifications C a se Encapsulant Flammibility Terminals Marking Approximate Weight Tolerance Polycarbonate Epoxy Conforms to UL94-VO Pins Ø 1.0mm
TALEMA Date Code (W/Y) AC1050, Dot at start pin
E n viro n men tal S p ecificatio n s Storage Temperature Insulation Resistance -55° to +130°C 100 megohms min.
%RE vs RL at Rated primary current (AC1050)
10000
47.3 grams ±0.2mm
Load Resistance RL in ohms
1000
Output Volts vs Input Current
For various ohmic loads
100
100
Infinity
Output Voltage in Volts
10K 5K 2K 1K 500 200 100
10 0 200 400 600 800 1000
Percent ratio error in %
10
Typical Excitation Curve (AC1040~AC1050)
100
1
50
Sec RMS Exciting Voltage in Volts
10
0.1 10 Input Current in Amps 100
1
Dimensions
34.90 14.30
0.1 0.01 0.1 1 10
Sec RMS Exciting Current in mA
34.90
TALEMA INDIA W/Y AC1050
Ø14.60
5±1mm Ø 1.016
2
3
25.40
1
2.08
Notes: 1) Unless requested, the terminating resistor and the one-turn primary are not supplied 2) Pin 3: Normally for mechanical support only but will be used on center tapped designs
1
10.16
I - Turn Primary
50A 50mA
3 2
RL
1/4W 5.0V 100 ohms