B32933B3474M000

B32933B3474M000

  • 厂商:

    TDK(东电化)

  • 封装:

    插件

  • 描述:

    0.47 µF 薄膜电容器 305V 聚酯,金属化 径向

  • 详情介绍
  • 数据手册
  • 价格&库存
B32933B3474M000 数据手册
Film Capacitors EMI Suppression Capacitors (MKT) Series/Type: B32932 ... B32936 Date: June 2020 © TDK Electronics AG 2020. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without TDK Electronics' prior express consent is prohibited. EMI Suppression Capacitors (MKT) B32932 ... B32936 X2 heavy duty series / 305 V AC Typical applications For connection in series with the mains For severe ambient conditions Capacitive power supply applications Energy meters Dimensional drawing Climatic Max. operating temperature: 105 °C Climatic category (IEC 60068-1:2013): 40/105/56 Features High stability of capacitance value X2 safety approval (up to 2.2 μF) RoHS-compatible AEC-Q200D compliant Construction Dielectric: metallized polyester Internal series connection Plastic case (UL 94 V-0) Epoxy resin sealing, flame-retardant Terminals Parallel wire leads, lead-free tinned Standard lead lengths: 6 1 mm Special lead lengths available on request Dimensions in mm Lead spacing ±0.4 Lead diameter d1 ±0.05 Type 15 0.8 B32932 22.5 0.8 B32933 27.5 0.8 B32934 37.5 1.0 B32936 Marking Manufacturer's logo, lot number, date code, rated capacitance (coded), capacitance tolerance (code letter), rated AC voltage (IEC), series number, sub-class (X2), dielectric code (MKT), climatic category Delivery mode Bulk (untaped, lead length 6 - 1 mm) Taped (Ammo pack or reel) Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 19 B32932 ... B32936 X2 heavy duty series / 305 V AC Marking example Approvals Approval mark Standards Certificate EN 60384-14:2014/A1:2016 IEC 60384-14:2013/AMD1:2016 40028058 UL 60384-14:2014 E97863 CSA E60384-14:2013 E97863 Note: X2 safety approval for C ≤2.2 μF Overview of available types Lead spacing 15 mm 22.5 mm 27.5 mm 37.5 mm Type B32933 B32934 B32936 B32932 CR (μF) 0.047 0.068 0.10 0.15 0.22 0.33 0.47 0.56 0.68 0.82 1.0 1.5 2.2 Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 19 B32932 ... B32936 X2 heavy duty series / 305 V AC Ordering codes and packing units Lead CR spacing mm μF 15 0.047 0.068 0.10 0.15 0.22 0.33 0.47 22.5 0.10 0.15 0.22 0.33 0.47 0.47 0.56 0.68 0.82 1.0 1.0 1.5 Max. dimensions w×h×l mm 5.0 × 10.5 × 18.0 5.0 × 10.5 × 18.0 6.0 × 11.0 × 18.0 7.0 × 12.5 × 18.0 8.5 × 14.5 × 18.0 9.0 × 17.5 × 18.0 11.0 × 18.5 × 18.0 6.0 × 15.0 × 26.5 6.0 × 15.0 × 26.5 7.0 × 16.0 × 26.5 7.0 × 16.0 × 26.5 8.5 × 16.5 × 26.5 10.5 × 16.5 × 26.5 10.5 × 16.5 × 26.5 10.5 × 18.5 × 26.5 12.0 × 22.0 × 26.5 12.0 × 22.0 × 26.5 14.5 × 29.5 × 26.5 14.5 × 29.5 × 26.5 Ordering code (composition see below) B32932A3473+*** B32932A3683+*** B32932A3104+*** B32932A3154+*** B32932A3224+*** B32932A3334+*** B32932A3474M*** B32933A3104+*** B32933A3154+*** B32933A3224+*** B32933A3334+*** B32933A3474M*** B32933B3474+*** B32933A3564+*** B32933A3684+*** B32933A3824+*** B32933A3105M*** B32933B3105+*** B32933A3155+*** Ammo pack pcs./MOQ 4680 4680 3840 3320 2720 2560 – 2720 2720 2320 2320 1920 1560 1560 1560 – – – – Reel Untaped X2 safety pcs./MOQ pcs./MOQ appr. 5200 4000 X 5200 4000 X 4400 4000 X 3600 4000 X 2800 2000 X 2800 2000 X 2200 1200 X 2800 2880 X 2800 2880 X 2400 2520 X 2400 2520 X 2000 2040 X 1600 2160 X 1600 2160 X 1600 2160 X – 1800 X – 1800 X – 1040 X – 1040 X X = approval granted MOQ = Minimum Order Quantity, consisting of 4 packing units. Further intermediate capacitance values on request. Composition of ordering code + = Capacitance tolerance code: M = ±20% K = ±10% Please read Cautions and warnings and Important notes at the end of this document. *** = Packaging code: 289 = Straight terminals, Ammo pack 189 = Straight terminals, Reel 000 = Straight terminals, Untaped (standard lead length 6 1 mm) Page 4 of 19 B32932 ... B32936 X2 heavy duty series / 305 V AC Ordering codes and packing units Lead CR spacing mm μF 27.5 0.47 0.56 0.68 0.82 1.0 1.0 1.5 1.5 2.2 37.5 1.0 1.5 2.2 Max. dimensions w×h×l mm 11.0 × 19.0 × 31.5 11.0 × 19.0 × 31.5 11.0 × 19.0 × 31.5 11.0 × 19.0 × 31.5 11.0 × 19.0 × 31.5 11.0 × 21.0 × 31.5 13.5 × 23.0 × 31.5 14.0 × 24.5 × 31.5 18.0 × 27.5 × 31.5 12.0 × 22.0 × 41.5 12.0 × 22.0 × 41.5 14.0 × 25.0 × 41.5 Ordering code (composition see below) B32934A3474+*** B32934A3564+*** B32934A3684+*** B32934A3824+*** B32934A3105M*** B32934B3105+*** B32934B3155M*** B32934D3155+*** B32934B3225+*** B32936A3105+*** B32936A3155+*** B32936A3225+*** Ammo pack pcs./MOQ – – – – – – – – – – – – Reel Untaped X2 safety pcs./MOQ pcs./MOQ appr. 1400 1280 X 1400 1280 X 1400 1280 X 1400 1280 X 1400 1280 X 1400 1280 X 1200 1120 X – 1040 X – 800 X – 1620 X – 1620 X – 1380 X X = approval granted MOQ = Minimum Order Quantity, consisting of 4 packing units. Further intermediate capacitance values on request. Composition of ordering code + = Capacitance tolerance code: M = ±20% K = ±10% Please read Cautions and warnings and Important notes at the end of this document. *** = Packaging code: 289 = Straight terminals, Ammo pack 189 = Straight terminals, Reel 000 = Straight terminals, Untaped (standard lead length 6 1 mm) Page 5 of 19 B32932 ... B32936 X2 heavy duty series / 305 V AC Technical data Reference standard: IEC 60384-14:2013/AMD1:2016 and AEC-Q200D. Max. operating temperature Top,max (Top = TA + self-heating) +105 °C Dissipation factor tan δ (in 10-3) at 20 °C (upper limit values) at C ≤ 1 μF 1 kHz 8 10 kHz 15 CR ≤ 0.33 μF 30 000 MΩ Insulation resistance Rins or time constant τ = CR  Rins at 20 °C, rel. humidity ≤ 65% (minimum as-delivered values) DC test voltage Passive flammability category to IEC 40 (CO) 752 Capacitance tolerances (measured at 1 kHz) Rated AC voltage ( IEC 60384-14 ) Maximum continuous DC voltage VDC Operating voltage Vop at high temperature Damp heat test Limit values after damp heat test Please read Cautions and warnings and Important notes at the end of this document. C > 1 μF 8  CR > 0.33 μF 10 000 s 1312 V DC, 2 s (4.3  VR according to IEC 60384-14) B ±10% (K), ±20% (M) 305 V (50/60 Hz) 500 V at Top ≤ 85 °C 1.5% / °C derating when 85 °C < Top ≤ 110 °C Top ≤ 105 °C Vop = 1.25  VAC (1000 h) Test conditions: 1. Temperature: Relative humidity (RH): Test duration: Voltage value: +85 °C ±2 °C 85% ±2% 1000 hours 240 V AC, 50 Hz 2. Temperature: Relative humidity (RH): Test duration: Voltage value: +40 °C ±2 °C 93% ±2% 2000 hours 305 V AC, 50 Hz Capacitance change (ΔC/C): Dissipation factor change (Δtan δ): Δtan δ/tan δ: Insulation resistance Rins or time constant τ = CR  Rins: Page 6 of 19 ≤ 10% ≤ 5  10-3 (at 1 kHz) ≤ 100% (at 10 kHz) > 10 MΩ B32932 ... B32936 X2 heavy duty series / 305 V AC Pulse handling capability "dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal voltages, expressed in V/μs. "k0" represents the maximum permissible pulse characteristic of the waveform applied to the capacitor, expressed in V2/μs. Note: The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the capacitor. dV/dt and k0 values Lead spacing (mm) dV/dt (V/μs) k0 (V2/μs) 15 90 108000 22.5 50 60000 27.5 35 42000 37.5 25 30000 Mounting guidelines 1 Soldering 1.1 Solderability of leads The solderability of terminal leads is tested to IEC 60068-2-20, test Ta, method 1. Before a solderability test is carried out, terminals are subjected to accelerated ageing (to IEC 60068-2-2, test Ba: 4 h exposure to dry heat at 155 °C). Since the ageing temperature is far higher than the upper category temperature of the capacitors, the terminal wires should be cut off from the capacitor before the ageing procedure to prevent the solderability being impaired by the products of any capacitor decomposition that might occur. Solder bath temperature 235 ±5 °C Soldering time 2.0 ±0.5 s Immersion depth 2.0 +0/0.5 mm from capacitor body or seating plane Evaluation criteria: Visual inspection Please read Cautions and warnings and Important notes at the end of this document. Wetting of wire surface by new solder ≥90%, free-flowing solder Page 7 of 19 B32932 ... B32936 X2 heavy duty series / 305 V AC 1.2 Resistance to soldering heat Resistance to soldering heat is tested to IEC 60068-2-20, test Tb, method 1. Conditions: Series Solder bath temperature Soldering time MKT boxed (except 2.5 × 6.5 × 7.2 mm) 260 ±5 °C coated uncoated (lead spacing >10 mm) MFP MKP (lead spacing >7.5 mm) MKT boxed (case 2.5 × 6.5 × 7.2 mm) MKP (lead spacing ≤7.5 mm) MKT uncoated (lead spacing ≤10 mm) insulated (B32559) 10 ±1 s 5 ±1 s
B32933B3474M000
物料型号:B32932至B32936,属于X2重型系列,额定305V交流电。

器件简介:这些电容器适用于与电源主线串联使用,特别适用于恶劣环境条件下的电容电源应用、能源计量器等。它们具有最高105°C的最大工作温度和40/105/56的气候类别。

引脚分配:电容器具有内部串联的引脚,引脚长度标准为61毫米,特殊长度可按要求提供。引脚间距和直径根据不同型号有所不同。

参数特性: - 电介质:金属化聚酯 - 外壳:UL 94 V-0等级塑料 - 密封材料:阻燃环氧树脂 - 额定电容值稳定性高 - X2安全认证(最高2.2微法拉) - 符合RoHS标准和AEC-Q200D规范

功能详解:电容器设计用于抑制电磁干扰,具有高稳定性的电容值和高脉冲负载能力,能够承受浪涌电压。

应用信息:适用于电源线串联,如电表、家用电器和工业设备的电源滤波。

封装信息:提供散装(无胶带,引脚长度6-11毫米)、胶带包装(弹药包或卷轴)等封装方式。

订购代码和包装单位:提供了详细的订购代码组成和最小订购量。

技术数据:包括最大操作温度、耗散因子、绝缘电阻、直流测试电压、被动火焰类别、电容公差、额定交流电压、最大连续直流电压、湿热测试等。

安装指南:提供了焊接性能测试、耐焊热性测试、焊接注意事项和推荐焊接参数。

注意事项和警告:强调了不要超过上类别温度、避免对电容器引脚施加机械应力、遵循焊接时间和温度限制等安全指南。

设计:电容器使用聚丙烯膜和锌金属化层,适合IEC/UL测试,并保持最小尺寸。

符号和术语:文档末尾提供了相关的电子元件参数的符号和中英文术语对照表。
B32933B3474M000 价格&库存

很抱歉,暂时无法提供与“B32933B3474M000”相匹配的价格&库存,您可以联系我们找货

免费人工找货