Standard 85 °C
General-purpose grade capacitors
Applications
Uninterruptible power supplies
Frequency converters
Features
All-welded construction ensures reliable electrical contact
RoHS-compatible
Construction
Charge-discharge proof, polar
Aluminum case with insulating sleeve
Poles with screw terminal connections
Mounting with ring clips, clamps or threaded stud
The bases of types with threaded stud and d ≤ 76.9 mm are not
insulated
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 17
B43464
B43484
B43464, B43484
Standard 85 °C
Specifications and characteristics in brief
Rated voltage VR
Surge voltage VS
Rated capacitance CR
Capacitance tolerance
350 ... 450 V DC
1.10 VR
1000 ... 12000 µF
±20% M
Dissipation factor tan δ
(20 °C, 120 Hz)
≤ 0.20
Leakage current Ileak
(20 °C, 5 min)
Self-inductance ESL
Useful life1)
85 °C; VR; IAC,R
40 °C; VR; 1.5 IAC,R
d = 51.6 mm: approx. 15 nH
d ≥ 64.3 mm: approx. 20 nH
Requirements:
∆C/C ≤ 15% of initial value
tan δ
≤ 1.75 times initial specified limit
Ileak
≤ initial specified limit
Voltage endurance test
Post test requirements:
85 °C; VR
2000 h
∆C/C ≤ 10% of initial value
tan δ
≤ 1.3 times initial specified limit
Ileak
≤ initial specified limit
Vibration resistance test To IEC 60068-2-6, test Fc:
Frequency range 10 ... 55 Hz, displacement amplitude 0.75 mm,
acceleration max. 10 g, duration 3 × 2 h. Capacitor mounted by its
body which is rigidly clamped to the work surface.
Characteristics at low
temperature
> 5000 h
> 90000 h
Max. impedance
ratio at 100 Hz
VR
350 ... 450 V
Z -25°C / Z 20°C 3
Z -40°C / Z 20°C 10
IEC climatic category
To IEC 60068-1:
40/085/56 (40 °C/+85 °C/56 days damp heat test)
Detail specification
Sectional specification
Similar to CECC 30301-810
IEC 60384-4
Ripple current capability
Due to the ripple current capability of the contact elements, the following current upper limits must
not be exceeded:
Capacitor diameter
51.6 mm
64.3 mm
76.9 mm
IAC,max
30 A
40 A
50 A
1) Refer to chapter "General technical information, 5 Useful life" on how to interpret useful life.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 17
B43464, B43484
Standard 85 °C
Dimensional drawings
B43464
Ring clip/clamp mounting
B43484
Threaded stud mounting
For types with threaded stud and d ≤ 76 mm the base is not insulated. Also refer to the mounting
instructions in chapter "Capacitors with screw terminals Accessories".
Dimensions and weights
Terminal
Dimensions (mm) with insulating sleeve
d
l ±1
l1 ±1
l2 +0/1 d1
d2 max. a +0.2/0.4
M5
M5
M5
51.6 +0/0.8
80.7
51.6 +0/0.8 105.7
51.6 +0/0.8 130.7
87.2
112.2
137.2
17
17
17
M12
M12
M12
10.2
10.2
10.2
22.2
22.2
22.2
220
280
350
M5
M5
M5
M5
64.3 +0/0.8
80.7
64.3 +0/0.8 105.7
64.3 +0/0.8 118.2
64.3 +0/0.8 130.7
87.2
112.2
124.7
137.2
17
17
17
17
M12
M12
M12
M12
13.2
13.2
13.2
13.2
28.5
28.5
28.5
28.5
370
440
510
600
M5
M5
M5
M5
M5
M5
76.9 +0/0.7
76.9 +0/0.7
76.9 +0/0.7
76.9 +0/0.7
76.9+0/0.7
76.9 +0/0.7
112.2
124.7
149.7
175.2
197.2
227.2
17
17
17
17
17
17
M12
M12
M12
M12
M12
M12
13.2
13.2
13.2
13.2
13.2
13.2
31.7
31.7
31.7
31.7
31.7
31.7
620
700
840
1000
1150
1300
105.7
118.2
143.2
168.7
190.7
220.7
Please read Cautions and warnings and
Important notes at the end of this document.
Page 4 of 17
Approx.
weight (g)
B43464, B43484
Standard 85 °C
Packing
Capacitor
diameter d (mm)
51.6
64.3
76.9
length l
(mm)
all
all
105.7 - 168.7
190.7 - 220.7
Packing units
(pcs.)
36
25
16
12
For ecological reasons the packing is pure cardboard.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 17
B43464, B43484
Standard 85 °C
Accessories
The following items are included in the delivery package, but are not fastened to the capacitors:
For terminals
Thread Toothed
washers
Screws/nuts
Maximum
torque
M5
DIN 7985 / ISO 7045-M5 × 10-5.6-Z
2.5 Nm
thread depth
t ≥ 8 mm
For mounting M12
A 5.1 DIN 6797
J 12.5 DIN 6797 Hex nut BM 12 DIN 439
10 Nm
The following items must be ordered separately. For details, refer to chapter "Screw terminals
Accessories".
Item
Ring clips
Clamps for capacitors with d ≥ 64.3 mm
Insulating parts
Please read Cautions and warnings and
Important notes at the end of this document.
Type
B44030
B44030
B44020
Page 6 of 17
B43464, B43484
Standard 85 °C
Overview of available types
VR (V DC)
350
400
450
Case dimensions d × l (mm)
CR (µF)
51.6 × 80.7
51.6 × 80.7
1500
51.6 × 80.7
51.6 × 80.7
51.6 × 105.7
2200
51.6 × 105.7
64.3 × 80.7
51.6 × 105.7
64.3 × 80.7
64.3 × 105.7
2700
64.3 × 80.7
51.6 × 130.7
64.3 × 105.7
3300
64.3 × 105.7
64.3 × 105.7
76.9 × 105.7
3900
64.3 × 105.7
64.3 × 118.2
64.3 × 130.7
4700
64.3 × 118.2
64.3 × 130.7
76.9 × 105.7
76.9 × 118.2
5600
76.9 × 105.7
76.9 × 118.2
76.9 × 143.2
6800
76.9 × 118.2
76.9 × 143.2
76.9 × 168.7
8200
76.9 × 143.2
76.9 × 168.7
76.9 × 220.7
10000
76.9 × 168.7
76.9 × 190.7
76.9 × 220.7
12000
76.9 × 190.7
76.9 × 220.7
1000
The capacitance and voltage ratings listed above are available in different cases upon request.
Other voltage and capacitance ratings are also available upon request.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 17
B43464, B43484
Standard 85 °C
Technical data and ordering codes
CR
100 Hz
20 °C
µF
Case
dimensions
d×l
mm
VR = 350 V DC
1500
51.6 × 80.7
2200
51.6 × 105.7
2200
64.3 × 80.7
2700
64.3 × 80.7
3300
64.3 × 105.7
3900
64.3 × 105.7
4700
64.3 × 118.2
5600
76.9 × 105.7
6800
76.9 × 118.2
8200
76.9 × 143.2
10000
76.9 × 168.7
12000
76.9 × 190.7
VR = 400 V DC
1000
51.6 × 80.7
1500
51.6 × 80.7
2200
51.6 × 105.7
2200
64.3 × 80.7
2700
51.6 × 130.7
3300
64.3 × 105.7
3900
64.3 × 118.2
4700
64.3 × 130.7
4700
76.9 × 105.7
5600
76.9 × 118.2
6800
76.9 × 143.2
8200
76.9 × 168.7
10000
76.9 × 190.7
12000
76.9 × 220.7
ESRtyp
100 Hz
20 °C
mΩ
Zmax
10 kHz
20 °C
mΩ
IAC,max
100 Hz
40 °C
A
IAC,R
100 Hz
85 °C
A
Ordering code
(composition see
below)
85
57
57
45
37
32
28
25
20
16
12
10
106
71
71
56
46
40
35
31
25
20
15
13
15
20
20
23
27
30
33
37
43
50
50
50
5.5
7.3
7.3
8.5
9.8
10.9
12.2
13.4
15.7
18.4
22.4
26.1
B434*4A4158M000
B434*4A4228M000
B434*4B4228M000
B434*4A4278M000
B434*4A4338M000
B434*4A4398M000
B434*4A4478M000
B434*4A4568M000
B434*4A4688M000
B434*4A4828M000
B434*4A4109M000
B434*4A4129M000
100
74
55
55
45
37
31
25
25
22
18
15
12
10
125
93
69
56
56
46
39
31
31
28
23
19
15
13
13
16
21
21
25
28
32
37
36
40
47
50
50
50
4.8
6.0
7.7
7.5
9.0
10.1
11.5
13.5
13.3
14.8
17.2
19.9
23.8
27.8
B434*4A9108M000
B434*4A9158M000
B434*4A9228M000
B434*4B9228M000
B434*4A9278M000
B434*4A9338M000
B434*4A9398M000
B434*4A9478M000
B434*4B9478M000
B434*4A9568M000
B434*4A9688M000
B434*4A9828M000
B434*4A9109M000
B434*4A9129M000
Composition of ordering code
* = Mounting style
6 = for capacitors with ring clip/clamp mounting
8 = for capacitors with threaded stud
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 17
B43464, B43484
Standard 85 °C
Technical data and ordering codes
CR
100 Hz
20 °C
µF
Case
dimensions
d×l
mm
VR = 450 V DC
1000
51.6 × 80.7
1500
51.6 × 105.7
2200
64.3 × 105.7
2700
64.3 × 105.7
3300
76.9 × 105.7
3900
64.3 × 130.7
4700
76.9 × 118.2
5600
76.9 × 143.2
6800
76.9 × 168.7
8200
76.9 × 220.7
10000
76.9 × 220.7
ESRtyp
100 Hz
20 °C
mΩ
Zmax
10 kHz
20 °C
mΩ
IAC,max
100 Hz
40 °C
A
IAC,R
100 Hz
85 °C
A
Ordering code
(composition see
below)
110
72
50
44
35
30
23
20
17
14
12
138
90
63
55
44
38
29
25
21
18
15
13
17
23
25
30
33
39
44
50
50
50
4.7
6.4
8.2
9.1
10.8
12.2
14.4
16.2
18.5
21.7
24.9
B434*4A5108M000
B434*4A5158M000
B434*4A5228M000
B434*4A5278M000
B434*4A5338M000
B434*4A5398M000
B434*4A5478M000
B434*4A5568M000
B434*4A5688M000
B434*4A5828M000
B434*4A5109M000
Composition of ordering code
* = Mounting style
6 = for capacitors with ring clip/clamp mounting
8 = for capacitors with threaded stud
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 17
B43464, B43484
Standard 85 °C
Useful life1)
depending on ambient temperature TA under ripple current operating conditions
Frequency factor of permissible ripple current IAC versus frequency f
1) Refer to chapter "General technical information, 5 Useful life" on how to interpret useful life.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 10 of 17
B43464, B43484
Standard 85 °C
Frequency characteristics of ESR
Typical behavior
Impedance Z versus frequency f
Typical behavior at 20 °C
Please read Cautions and warnings and
Important notes at the end of this document.
Page 11 of 17
B43464, B43484
Standard 85 °C
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have been optimized both with a view to the intended
application and with regard to health and environmental compatibility. They do not contain any
solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, some of the high-voltage electrolytes used by EPCOS are self-extinguishing.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no alternative materials are currently
known. However, the amount of dangerous materials used in our products is limited to an
absolute minimum.
Materials and chemicals used in EPCOS aluminum electrolytic capacitors are continuously
adapted in compliance with the EPCOS Corporate Environmental Policy and the latest EU
regulations and guidelines such as RoHS, REACH/SVHC, GADSL, and ELV.
MDS (Material Data Sheets) are available on the EPCOS website for all types listed in the data
book. MDS for customer specific capacitors are available upon request.
MSDS (Material Safety Data Sheets) are available for all of our electrolytes upon request.
Nevertheless, the following rules should be observed when handling aluminum electrolytic
capacitors: No electrolyte should come into contact with eyes or skin. If electrolyte does come
into contact with the skin, wash the affected areas immediately with running water. If the eyes are
affected, rinse them for 10 minutes with plenty of water. If symptoms persist, seek medical
treatment. Avoid inhaling electrolyte vapor or mists. Workplaces and other affected areas should
be well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 12 of 17
B43464, B43484
Standard 85 °C
Product safety
The table below summarizes the safety instructions that must be observed without fail. A detailed
description can be found in the relevant sections of chapter "General technical information".
Topic
Safety information
Polarity
Make sure that polar capacitors are connected
with the right polarity.
Reverse voltage
Voltages polarity classes should be prevented by
connecting a diode.
Do not mount the capacitor with the terminals
(safety vent) upside down.
Mounting
position of screwterminal capacitors
Robustness of
terminals
Mounting of
single-ended
capacitors
Soldering
Soldering,
cleaning agents
Upper category
temperature
Passive
flammability
The following maximum tightening torques must
not be exceeded when connecting screw
terminals:
M5: 2.5 Nm
M6: 4.0 Nm
The internal structure of single-ended capacitors
might be damaged if excessive force is applied to
the lead wires.
Avoid any compressive, tensile or flexural stress.
Do not move the capacitor after soldering to PC
board.
Do not pick up the PC board by the soldered
capacitor.
Do not insert the capacitor on the PC board with a
hole space different to the lead space specified.
Do not exceed the specified time or temperature
limits during soldering.
Do not allow halogenated hydrocarbons to come
into contact with aluminum electrolytic capacitors.
Do not exceed the upper category temperature.
Avoid external energy, such as fire or electricity.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 13 of 17
Reference
chapter "General
technical information"
1
"Basic construction of
aluminum electrolytic
capacitors"
3.1.6
"Reverse voltage"
11.1.
"Mounting positions of
capacitors with screw
terminals"
11.3
"Mounting torques"
11.4
"Mounting
considerations for
single-ended capacitors"
11.5
"Soldering"
11.6
"Cleaning agents"
7.2
"Maximum permissible
operating temperature"
8.1
"Passive flammability"
B43464, B43484
Standard 85 °C
Topic
Safety information
Active
flammability
Maintenance
Avoid overload of the capacitors.
Storage
Make periodic inspections of the capacitors.
Before the inspection, make sure that the power
supply is turned off and carefully discharge the
electricity of the capacitors.
Do not apply any mechanical stress to the
capacitor terminals.
Do not store capacitors at high temperatures or
high humidity. Capacitors should be stored at
+5 to +35 °C and a relative humidity of ≤ 75%.
Breakdown strength Do not damage the insulating sleeve, especially
of insulating
when ring clips are used for mounting.
sleeves
Please read Cautions and warnings and
Important notes at the end of this document.
Page 14 of 17
Reference
chapter "General
technical information"
8.2
"Active flammability"
10
"Maintenance"
7.3
Storage conditions
Reference
chapter "Capacitors with
screw terminals"
"Screw terminals
accessories"
B43464, B43484
Standard 85 °C
Symbols and terms
Symbol
English
German
C
CR
CS
CS,T
Cf
d
dmax
ESL
ESR
ESRf
Capacitance
Rated capacitance
Series capacitance
Series capacitance at temperature T
Capacitance at frequency f
Case diameter, nominal dimension
Maximum case diameter
Self-inductance
Equivalent series resistance
Equivalent series resistance at
frequency f
Equivalent series resistance at
temperature T
Frequency
Current
Alternating current (ripple current)
Root-mean-square value of alternating
current
Ripple current at frequency f
Maximum permissible ripple current
Rated ripple current
Rated ripple current for base cooling
Leakage current
Operating leakage current
Case length, nominal dimension
Maximum case length (without
terminals and mounting stud)
Resistance
Insulation resistance
Balancing resistance
Temperature
Temperature difference
Ambient temperature
Case temperature
Capacitor base temperature
Time
Period
Service life (operating hours)
Kapazität
Nennkapazität
Serienkapazität
Serienkapazität bei Temperatur T
Kapazität bei Frequenz f
Gehäusedurchmesser, Nennmaß
Maximaler Gehäusedurchmesser
Eigeninduktivität
Ersatzserienwiderstand
Ersatzserienwiderstand bei Frequenz f
ESRT
f
I
IAC
IAC,rms
IAC,f
IAC,max
IAC,R
IAC,R (B)
Ileak
Ileak,op
l
lmax
R
Rins
Rsymm
T
∆T
TA
TC
TB
t
∆t
tb
Please read Cautions and warnings and
Important notes at the end of this document.
Ersatzserienwiderstand bei Temperatur T
Frequenz
Strom
Wechselstrom
Wechselstrom, Effektivwert
Wechselstrom bei Frequenz f
Maximal zulässiger Wechselstrom
Nennwechselstrom
Nennwechselstromstrom für Bodenkühlung
Reststrom
Betriebsreststrom
Gehäuselänge, Nennmaß
Maximale Gehäuselänge (ohne Anschlüsse
und Gewindebolzen)
Widerstand
Isolationswiderstand
Symmetrierwiderstand
Temperatur
Temperaturdifferenz
Umgebungstemperatur
Gehäusetemperatur
Temperatur des Becherbodens
Zeit
Zeitraum
Brauchbarkeitsdauer (Betriebszeit)
Page 15 of 17
B43464, B43484
Standard 85 °C
Symbol
V
VF
Vop
VR
VS
XC
XL
Z
ZT
tan δ
λ
ε0
εr
ω
English
Voltage
Forming voltage
Operating voltage
Rated voltage, DC voltage
Surge voltage
Capacitive reactance
Inductive reactance
Impedance
Impedance at temperature T
Dissipation factor
Failure rate
Absolute permittivity
Relative permittivity
Angular velocity; 2 π f
German
Spannung
Formierspannung
Betriebsspannung
Nennspannung, Gleichspannung
Spitzenspannung
Kapazitiver Blindwiderstand
Induktiver Blindwiderstand
Scheinwiderstand
Scheinwiderstand bei Temperatur T
Verlustfaktor
Ausfallrate
Elektrische Feldkonstante
Dielektrizitätszahl
Kreisfrequenz; 2 π f
Note
All dimensions are given in mm.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 16 of 17
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CeraLink, CeraPlas, CSMP, CSSP,
CTVS, DeltaCap, DigiSiMic, DSSP, FilterCap, FormFit, MiniBlue, MiniCell, MKD, MKK,
MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI,
SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K,
ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
Page 17 of 17