SIOV metal oxide varistors
Strap varistors, HighE, AdvanceD, LS41 series
Series/Type:
B722*
Date:
January 2018
© EPCOS AG 2018. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Strap varistors
B722*
HighE, AdvanceD, LS41 series
Construction
Rectangular varistor element
Coating: epoxy resin, flame-retardant to UL 94 V-0
Bolt-holed strap terminals for screw fixing or soldering
Bent or straight strap terminals
Features
Dimensions equivalent to SIOV-LS40
High surge current up to 50 kA
Wide operating voltage range 130 … 460 VRMS
Designed in accordance with the requirements of IEC 61643-1, class II, for low-voltage
surge protection devices
Approvals
UL
CSA
Delivery mode
Vacuum-packed styrofoam box
General technical data
Climatic category
Operating temperature
Storage temperature
Electric strength
Insulation resistance
Please read Cautions and warnings and
Important notes at the end of this document.
to IEC 60068-1
to CECC 42000
to CECC 42 000
to CECC 42 000
Page 2 of 13
40/85/56
25 ... + 85
25 ... +110
≥ 2.5
≥ 10
°C
°C
kVRMS
MΩ
Strap varistors
B722*
HighE, AdvanceD, LS41 series
Electrical specifications and ordering codes
Maximum ratings (TA = 85 °C)
Ordering code
Bent strap terminals
B72241L0131K100
B72241L0141K100
B72241L0151K100
B72241L0231K100
B72241L0251K100
B72241L0271K100
B72241L0321K100
B72241L0381K100
B72241L0421K100
B72241L0441K100
B72241L0461K100
Straight strap terminals
B72241L0131K102
B72241L0141K102
B72241L0151K102
B72241L0231K102
B72241L0251K102
B72241L0271K102
B72241L0321K102
B72241L0381K102
B72241L0421K102
B72241L0441K102
B72241L0461K102
In2)
(8/20 µs)
15 times
A
Wmax
(2 ms)
Pmax
V
Imax1)
(8/20 µs)
1 time
A
J
W
130
140
150
230
250
275
320
385
420
440
460
170
180
200
300
320
350
420
505
560
585
615
50000
50000
50000
50000
50000
50000
50000
50000
50000
50000
50000
20000
20000
20000
20000
20000
20000
20000
20000
20000
20000
20000
310
340
360
460
490
550
640
800
910
950
960
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
130
140
150
230
250
275
320
385
420
440
460
170
180
200
300
320
350
420
505
560
585
615
50000
50000
50000
50000
50000
50000
50000
50000
50000
50000
50000
20000
20000
20000
20000
20000
20000
20000
20000
20000
20000
20000
310
340
360
460
490
550
640
800
910
950
960
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
Type
VRMS
VDC
SIOV-
V
LS41K130QP
LS41K140QP
LS41K150QP
LS41K230QP
LS41K250QP
LS41K275QP
LS41K320QP
LS41K385QP
LS41K420QP
LS41K440QP
LS41K460QP
LS41K130QPK2
LS41K140QPK2
LS41K150QPK2
LS41K230QPK2
LS41K250QPK2
LS41K275QPK2
LS41K320QPK2
LS41K385QPK2
LS41K420QPK2
LS41K440QPK2
LS41K460QPK2
1) Imax = Maximum discharge current to IEC 61643-11, class II
2) In = Nominal discharge current to IEC 61643-11, class II
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 13
Strap varistors
B722*
HighE, AdvanceD, LS41 series
Characteristics (TA = 25 °C)
Ordering code
Type
SIOVBent strap terminals
B72241L0131K100 LS41K130QP
B72241L0141K100 LS41K140QP
B72241L0151K100 LS41K150QP
B72241L0231K100 LS41K230QP
B72241L0251K100 LS41K250QP
B72241L0271K100 LS41K275QP
B72241L0321K100 LS41K320QP
B72241L0381K100 LS41K385QP
B72241L0421K100 LS41K420QP
B72241L0441K100 LS41K440QP
B72241L0461K100 LS41K460QP
Straight strap terminals
B72241L0131K102 LS41K130QPK2
B72241L0141K102 LS41K140QPK2
B72241L0151K102 LS41K150QPK2
B72241L0231K102 LS41K230QPK2
B72241L0251K102 LS41K250QPK2
B72241L0271K102 LS41K275QPK2
B72241L0321K102 LS41K320QPK2
B72241L0381K102 LS41K385QPK2
B72241L0421K102 LS41K420QPK2
B72241L0441K102 LS41K440QPK2
B72241L0461K102 LS41K460QPK2
Please read Cautions and warnings and
Important notes at the end of this document.
Vv
(1 mA)
V
∆Vv
(1 mA)
%
vc,max
(ic)
V
ic
A
Ctyp
(1 kHz)
pF
205
220
240
360
390
430
510
620
680
715
750
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
340
365
395
595
650
710
840
1025
1120
1180
1240
300
300
300
300
300
300
300
300
300
300
300
5600
5200
4800
3200
2900
2700
2300
1900
1800
1700
1600
205
220
240
360
390
430
510
620
680
715
750
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
±10
340
365
395
595
650
710
840
1025
1120
1180
1240
300
300
300
300
300
300
300
300
300
300
300
5600
5200
4800
3200
2900
2700
2300
1900
1800
1700
1600
Page 4 of 13
Strap varistors
B722*
HighE, AdvanceD, LS41 series
Dimensional drawings
Bent strap terminals
SIOV-LS41K ... QP
Weight: 20 ... 40 g
Straight strap terminals
Ordering code
Bent strap terminals
B72241L0131K100
B72241L0141K100
B72241L0151K100
B72241L0231K100
B72241L0251K100
B72241L0271K100
B72241L0321K100
B72241L0381K100
B72241L0421K100
B72241L0441K100
B72241L0461K100
Straight strap terminals
B72241L0131K102
B72241L0141K102
B72241L0151K102
B72241L0231K102
B72241L0251K102
B72241L0271K102
B72241L0321K102
B72241L0381K102
B72241L0421K102
B72241L0441K102
B72241L0461K102
SIOV-LS41K ... QPK2
Weight: 20 ... 40 g
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 13
thmax
mm
L ±1.0
mm
8.1
8.2
8.3
9.0
9.2
9.4
9.9
10.6
10.9
11.1
11.4
3.5
3.3
3.2
2.0
1.8
1.6
1.1
0.4
0.0
0.2
0.4
8.1
8.2
8.3
9.0
9.2
9.4
9.9
10.6
10.9
11.1
11.4
4.4
4.5
4.6
5.4
5.6
5.8
6.3
6.9
7.3
7.6
7.8
Strap varistors
B722*
HighE, AdvanceD, LS41 series
Reliability data
Test
Test methods/conditions
Varistor voltage
The voltage between two terminals with To meet the specified value
the specified measuring current applied
is called VV (1 mADC @ 0.2 ... 2 s).
Clamping voltage
The maximum voltage between two
terminals with the specified standard
impulse current (8/20 µs) applied.
Max. DC operating
voltage
The maximum allowable DC operating Ileak (t = 1000 h) ≤ Ileak (t = 0 h)
voltage VDC at UCT +5/–0 °C is applied |∆V/V (1 mA)| ≤10%
for 1000 ±48 h.
The leakage current Ileak (t) during test is
recorded.
Then the specimen shall be stored at
room temperature and normal humidity
for 1 to 2 h.
Thereafter, the change of VV shall be
measured.
Surge current derating,
8/20 µs
10 surge currents (8/20 µs), unipolar,
interval ≥60 s, amplitude corresponding
to derating curve for 10 impulses at
20 µs
Fast temperature cycling IEC 60068-2-14, test Na, LCT/UCT,
dwell time 30 min, 5 cycles
Requirement
To meet the specified value
|∆V/V (1 mA)| ≤10%
(measured in direction of
surge current)
No visible damage
|∆V/V (1 mA)| ≤10%
No visible damage
Damp heat, steady state IEC 60068-2-78
|∆V/V (1 mA)| ≤10%
The specimen shall be subjected to
40 ±2 °C, 90 to 95% r. H. for 56 ±2 days
with 10% of the maximum continuous
DC operating voltage VDC.
Then stored at room temperature and
normal humidity for 1 to 2 h.
Thereafter, the change of VV shall be
measured.
Note:
UCT = Upper category temperature
LCT = Lower category temperature
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 13
Strap varistors
B722*
HighE, AdvanceD, LS41 series
v/i characteristics
v = f (i) for explanation of the characteristics refer to "General technical information", chapter 1.6.3
A = Leakage current, B = Protection level } for worst-case varistor tolerances
SIOV-LS41K130QP(K2) ... K460QP(K2)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 13
Strap varistors
B722*
HighE, AdvanceD, LS41 series
Derating curves
Maximum surge current imax = f (tr, pulse train)
For explanation of the derating curves refer to "General technical information", section 1.8.1
SIOV-LS41K130QP(K2) ... K150QP(K2)
SIOV-LS41K230QP(K2) ... K460QP(K2)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 13
Strap varistors
B722*
HighE, AdvanceD, LS41 series
Cautions and warnings
General
1. EPCOS metal oxide varistors are designed for specific applications and should not be used
for purposes not identified in our specifications, application notes and data books unless otherwise agreed with EPCOS during the design-in-phase.
2. Ensure suitability of SIOVs through reliability testing during the design-in phase. SIOVs
should be evaluated taking into consideration worst-case conditions.
3. For applications of SIOVs in line-to-ground circuits based on various international and local
standards there are restrictions existing or additional safety measures required.
Storage
1. Store SIOVs only in original packaging. Do not open the package prior to processing.
2. Recommended storage conditions in original packaging:
Storage temperature: 25 °C ... +45 °C,
Relative humidity:
很抱歉,暂时无法提供与“B72241L0251K100”相匹配的价格&库存,您可以联系我们找货