CCG 15-30W Series
13.2 to 30W DC-DC Converters
https://product.tdk.com/en/power/ccg
www.emea.lambda.tdk.com/ccg
The 1” x 1” footprint CCG15 and CCG30 series of isolated DC-DC converters operate from wide range 9 to 36Vdc or 18 to 76V inputs with 15W and 30W
power levels and output voltages from 3.3V to 30V (1). Single output models can be adjusted -10% to +10% by using the trim terminal. The CCG can operate
in ambient temperatures of -40 to 85°C and has an input to output isolation of 1,500Vdc. Six sided shielding reduces radiated and conducted EMI.
Features
Benefits
• Wide 4:1 Input Ranges
• Supports Dual 12/24V or 24/48V System Voltages
• Space Saving Package Sizes
• Less Board Area Needed
• Certified to IEC 62368-1
• Easier System Compliance
• Reduced Derating at High Ambient Temperatures
• More Useable Power
Model Selector
Model
Input
Voltage
(V)
CCG15-24-03S
CCG30-24-03S
CCG15-24-05S
CCG30-24-05S
CCG15-24-12S
CCG30-24-12S
CCG15-24-15S
CCG30-24-15S
9 - 36
CCG15-24-12D (1)
CCG30-24-12D (1)
CCG15-24-15D (1)
CCG30-24-15D (1)
CCG15-24-12D
CCG30-24-12D
CCG15-24-15D
CCG30-24-15D
CCG15-48-03S
CCG30-48-03S
CCG15-48-05S
CCG30-48-05S
CCG15-48-12S
CCG30-48-12S
CCG15-48-15S
CCG30-48-15S
18 - 76
CCG15-48-12D (1)
CCG30-48-12D (1)
CCG15-48-15D (1)
CCG30-48-15D (1)
CCG15-48-12D
CCG30-48-12D
CCG15-48-15D
CCG30-48-15D
Voltage
(V)
Output
Current
(A)
3.3 4
3.3
7
5
3
5
6
12
1.3
12
2.5
15
1
15
2
24
0.65
24
1.25
30
0.5
30
1
±12
±0.65
±12
±1.25
±15
±0.5
±15
±1.0
3.3
4
3.3
7
5
3
5
6
12
1.3
12
2.5
15
1
15
2
24
0.65
24
1.25
30
0.5
30
1
±12
±0.65
±12
±1.25
±15
±0.5
±15
±1.0
Maximum
Power
(W)
Input Current at
nominal input
(A)
13.2
23.1
15.0
30.0
15.6
30.0
15.0
30.0
15.6
30.0
15.0
30.0
15.6
30.0
15.0
30.0
13.2
23.1
15.0
30.0
15.6
30.0
15.0
30.0
15.6
30.0
15.0
30.0
15.6
30.0
15.0
30.0
Efficiency (%)
(100% load,
nominal input)
0.65
1.12
0.72
1.4
0.74
1.4
0.71
1.4
0.73
1.4
0.7
0.38
0.73
1.4
0.7
0.38
0.32
0.55
0.36
0.69
0.37
0.69
0.36
0.69
0.37
0.69
0.35
0.68
0.37
0.69
0.35
0.68
85
86
87
89
88
89
88
89
89
89
90
91
89
89
90
91
85
87
87
90
88
90
88
91
89
91
90
92
89
91
90
92
(1) ±12V dual output models can provide a 24V single output by utilizing just the +Vout and -Vout pins, leaving the COM unconnected.
Similarly ±15V dual output models can be used as a 30V single output.
CCG15-30W Series
1
CCG
Series Name
15
-24
Output Power
15 = 15W
30 = 30W
Input Voltage
24 = 9 - 36V
48 = 18 - 76V
-03
Output Voltage
03 = 3.3V
05 = 5V
12 = 12V
15 = 15V
±12V = +12V, -12V
±15V = +15V, -15V
S
S = Single
Output
D = Dual
Output
Remote on/off
Blank = Negative Logic
/P = Positive Logic
Related Products
Type
Part Number
Description
Isolated DC-DC Converter
Evaluation Kit
Isolated DC-DC Converter
DC-DC Non-isolated Buck Converter
DC-DC Non-isolated Buck Converter
DC-DC Non-isolated Buck Converter
Ruggedized DC-DC Buck-Boost Converter
Isolated DC-DC Converter
Isolated DC-DC Converter
CCG15-30
CCG-EVK-D0
PXD40
i3A
i6A4W
i7A
RGC
PYD20
PYQ50
15-30W, 9 up to 76Vin, Single or Dual Output, 1x1 inch
Evaluation board (no module) for CCG15 or CCG30
40W, 9-36 or 18-75Vin, Single or Dual Outputs, 2x1 inch
100W, 9-53Vin, Output 5-30V 4.5A; 3.3-16.5V 8A, 1/32nd brick
250W, 9-53Vin, Output 3.3-40V 10A; 3.3-15V 20A, 16th brick
400-750W, 9 up to 60Vin, 0.8 up to 24Vout, 33A, 45A, 60A, 16th brick pinout
300W, 9-53Vin, Output 9.6-48V 8A; 5-28V 12.5A, 16th brick pinout
20W, 8.5-160Vin, Single or Dual Outputs, 2x1 inch
30-50W, 14-160Vin, Single Output, Quarter brick
Specification
Model
Input
Input Voltage Range
Vdc
No Load Power Consumption
W
Efficiency
-
Conducted & Radiated EMI
-
Immunity
-
Safety Certifications and Markings
-
CCG15-30W
See model selector table
0.6 to 0.9 (model dependent). See evaluation data on website for further details(1)
No load power can be reduced using the remote on/off function (standby mode)
See model selector table
EN55011/EN55032-A, FCC Class A, VCCI-A
(External components are required, consult Evaluation Data on website)(1)
IEC61000-4-2, -3, -4, -5, -6, -8; IEC61000-6-2
(External components are required, consult Immunity Data on website)(1)
IEC/UL/CSA/EN62368-1, CE Mark and UKCA Mark
Immunity
Test
Standard
Test Level
Criteria
ESD
EN61000-4-2
Radiated Susceptibility
EN61000-4-3
Electrical Fast Transient Burst
EN61000-4-4
Surge
EN61000-4-5
Conducted Susceptibility
EN61000-4-6
Magnetic Fields
EN61000-4-8
2
Notes: See IEC61000 immunity test report on
website for external filtering circuitry(1)
Air and contact ± 8kV
A
80M -1GHz: 10V/m
1.4 - 2.0GHz: 3V/m
A
2.0 - 2.7GHz: 1V/m
± 4kV for input and output
A/B
CCG15S: B
± 2kV for signal pins
± 2kV
A
Normal mode
10Vrms
A
30A/m
A
CCG15-30W Series
Specification
Model
Output
Output Voltage Tolerance
%
Output Voltage Adjustment
%
Switching Frequency
kHz
Cross Regulation
%
External Load Capacitance
uF
Ripple & Noise
mV
Temperature Coefficient
%/°C
Minimum Load
-
Overcurrent Protection
%
Overvoltage Protection
-
Overtemperature Protection
Remote Sense
Remote On/Off
-
Parallel Operation
-
Series Operation
-
Environmental
Operating Temperature
°C
Maximum Case Temperature
°C
Storage Temperature
°C
Humidity (non condensing)
%RH
Cooling
-
Altitude
m
Withstand Voltage (For 1 minute)
Vdc
Isolation Resistance
MΩ
Vibration (Non operating)
-
Shock (Non operating)
-
Other
Weight (Typ)
g
Size (LxWxH)
mm
Size (LxWxH)
Inches
Case Material
-
MTBF - Telcordia SR-332 issue 3*
Hours
Warranty yrs
CCG15-30W
± 2
Single output only. ± 10%
CCG15-S: 430, CCG30S: 3.3/5V: 270, 12/15: 360, CCG-D: 430
Dual output only. ± 12V: 480, ± 15V: 600 (Asymmetrical, one output at 20%, the other at 100%)
3.3V: 10,000, 5V: 7,200, 12V: 1,200, 15V: 1,000 ±12V: ±1,200, ±15V: ±1,000, 24V: 560, 30V: 470
3.3/5V: 70, 12/15V: 95
0.02
No minimum load required
Hiccup mode. >105%
No
No
No remote sense
No suffix: Negative Logic - ON when pin is shorted , OFF when open
/P suffix: Positive Logic - ON when pin is open, OFF when pin is Low
Not possible
Possible
-40 to +85 (Ambient)
110
-55 to +125
5 - 95 (Operating & Storage)
Convection or forced air
5000
Input to case 1,000, input to output 1,500, output to case, 1,000
>100, output to case 500Vdc (25°C, 70%RH)
10-55Hz (Sweep for 3 min.)
Amplitude 1.52 mm Constant (Maximum 90.8m/s2) X, Y, Z 1 hour each
490.3m/s2, 11ms, ±X, ±Y, ±Z 3 times each
20
25.4 x 25.4 x 9.9
1 x 1 x 0.39
Metal
3,191,064
5
Notes
(1) See website for detailed specifications, test methods and installation manual
*CCG30-24-12S model, 25°C ambient, full load, 24Vdc input
CCG15-30W Series
3
Outline Drawing CCG15-S (Single Output)
Outline Drawing CCG15-D (Dual Output)
Unit mm
Unit mm
Outline Drawing CCG30-S (Single Output)
Outline Drawing CCG30-D (Dual Output)
Unit mm
4
Unit mm
CCG15-30W Series
TDK-Lambda France SAS
TDK-Lambda Americas
Tel: +33 1 60 12 71 65
tlf.fr-powersolutions@tdk.com
Tel: +1 800-LAMBDA-4 or 1-800-526-2324
tla.powersolutions@tdk.com
www.us.lambda.tdk.com
www.emea.lambda.tdk.com/fr
Italy Sales Office
Tel: +39 02 61 29 38 63
tlf.it-powersolutions@tdk.com
www.emea.lambda.tdk.com/it
Netherlands
tlf.nl-powersolutions@tdk.com
TDK Electronics do Brasil Ltda
Tel: +55 11 3289-9599
sales.br@tdk-electronics.tdk.com
www.tdk-electronics.tdk.com/en
www.emea.lambda.tdk.com/nl
TDK-Lambda Germany GmbH
Tel: +49 7841 666 0
tlg.powersolutions@tdk.com
www.emea.lambda.tdk.com/de
TDK-Lambda Corporation
Tel: +81-3-6778-1113
www.jp.lambda.tdk.com
TDK-Lambda (China) Electronics Co. Ltd.
Tel: +86 21 6485-0777
tlc.powersolutions@tdk.com
www.lambda.tdk.com.cn
Austria Sales Office
Tel: +43 2256 655 84
tlg.at-powersolutions@tdk.com
TDK-Lambda Singapore Pte Ltd.
Switzerland Sales Office
Tel: +65 6251 7211
tls.marketing@tdk.com
www.sg.lambda.tdk.com
Tel: +41 44 850 53 53
tlg.ch-powersolutions@tdk.com
TDK India Private Limited, Power Supply Division
www.emea.lambda.tdk.com/at
www.emea.lambda.tdk.com/ch
Nordic Sales Office
Tel: +91 80 4039-0660
mathew.philip@tdk.com
www.sg.lambda.tdk.com
Tel: +45 8853 8086
tlg.dk-powersolutions@tdk.com
www.emea.lambda.tdk.com/dk
TDK-Lambda UK Ltd.
Tel: +44 (0) 12 71 85 66 66
tlu.powersolutions@tdk.com
www.emea.lambda.tdk.com/uk
TDK-Lambda Ltd.
Tel: +9 723 902 4333
tli.powersolutions@tdk.com
www.emea.lambda.tdk.com/il-en
For Additional Information, please visit
https://product.tdk.com/en/power/
CCG15-30_260829_January 2nd, 2024 V3
CCG15-30W Series