HAQ10T

HAQ10T

  • 厂商:

    TDK(东电化)

  • 封装:

    -

  • 描述:

    HEATSINK FOR CNA30-100

  • 数据手册
  • 价格&库存
HAQ10T 数据手册
CN-A110 SERIES Optimum DC-DC Power Module for Railway Related Instruments OTHERS UL60950-1 CSA60950-1 EN60950-1 EN60950-1 (TUV) Low Voltage Directive 5 warranty (CN200A110 is designed to meet) ■ Features ● Optimum wide input voltage range for Railway Related Instruments, input voltage: 60 to 160 VDC ●A  nti-vibration and shock resistance characteristics Y E A R S ■ Model naming method CN 100 A 110 - 5 Output voltage Input voltage conforming to IEC61373 ● 5 years free warranty Series name ● Brick shaped utilized (1/4 brick for 30W-50W- Output power 100W, 1/2 brick for 200W) Series name ■ Applications ■ Conformity to RoHS Directive This means that, in conformity with EU Directive 2002/95/ EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, OTHERS have not been used, except for exempted applications. Y ■ Product Line up E A R S Output Voltage warranty Output Current 30W 50W 100W 200W Model Output Current Model Output Current Model Output Current Model 5 6 CN30A110-5 10 CN50A110-5 20 CN100A110-5 40 CN200A110-5 12 2.5 CN30A110-12 4.2 CN50A110-12 8.4 CN100A110-12 16.7 CN200A110-12 15 2 CN30A110-15 3.4 CN50A110-15 6.7 CN100A110-15 13.4 CN200A110-15 24 1.3 CN30A110-24 2.1 CN50A110-24 4.2 CN100A110-24 8.4 CN200A110-24 ・All specifications are subject to change without notice.  CN30A110 CN30A110 Specifications ITEMS/UNITS  MODEL Voltage Range V Input Efficiency(typ) (*1) % Current (*1) CN30A110-5 CN30A110-12 CN30A110-15 60 - 160 83 84 A 0.34 VDC 5 12 15 Maximum Current A 6 2.5 2 Maximum Power W Nominal Voltage CN30A110-24 30 Voltage Setting Accuracy (*1) % 24 1.3 31.2 -/+ 1 Output Maximum Line Regulation(*2) mV 20 48 60 96 Maximum Load Regulation(*3) mV 40 96 120 192 0.02%/°C Temperature Coefficient Maximum Ripple & Noise (*8) mVp-p 100 Voltage Adjustable Range (*8) VDC -10 / +20 Over Current Protection (*4) A Over Voltage Protection(*5)(*7) VDC Function Remote Sensing 150 240 -/+ 10 105 - 140 125 - 145 (Inverter shutdown method) Possible (*7) Possible (SHORT : ON OPEN : OFF) Remote ON/OFF Control  (*7) - Parallel Operation Possible Series Operation (*7) Operating Temperature (*6) ℃ -40 - +100 (Baseplate) Ambient Temperature min=-40°C ℃ -40 - +100 Operating Humidity % RH 5 - 95 (No Dewdrop) Storage Humidity % RH Storage Temperature Environment 5 - 95 (No Dewdrop) At No Operating, 10-55Hz (Sweep for 1min.) Amplitude 0.825mm Constant (Maximum 49.0m/s²) X,Y,Z 1 hour each Vibration IEC61373 - Categoly 1 - Grade B 196.1m/s² Shock Conduction Cooled Cooling Isolation Input-Baseplate : 1.5kVAC, Input-Output : 3.0kVAC for 1min. Withstand Voltage Output-Baseplate : 500VAC for 1min. Isolation Resistance More than 100MΩ at 25°C and 70%RH Output-Baseplate…500VDC Standards Safety Standards Mechanical Weight(typ) Size (W×H×D) Approved by UL60950-1, CSA60950-1, EN60950-1 g 100 mm 36.8 x 12.7 x 57.9 (Refer to Outline Drawing) *1. At 110VDC and maximum output current. (Baseplate Temperature = +25°C) *2. 60 - 160VDC, Constant load. *3. No Load - Full Load, Constant input voltage. *4. 5V automatically shutdown when left in OCP condition, with the output voltage less than the LVP level. 12V, 15V and 24V constant current limiting with automatic recovery. LVP reset : Line off or Control off. *5. OVP reset : Line off or Control off. *6. Rating - Refer to Derating Curve on the right. - Load(%) is percent of maximum output current. - Refer to Instruction Manual. *7. Refer to Instruction Manual. *8. External components are needed for operation. (Refer to Basic Connection and Instruction Manual.)  ・All specifications are subject to change without notice. CN30A110 CN30A110 Outline Drawing ( unit:mm ) CL 57.9±0.5 6-Φ1  Input and signal terminals 2-Φ1.5  TRM +S +V 7.62±0.25 -S 15.24±0.25 -V +Vin +Vin -S CNT TRM 28±0.25 36.8±0.5 12.7±0.25 CNT CL -V +S -Vin -Vin +V Output terminals MADE IN JAPAN 2-M3 For mounting (FG) Name plate 12.7±0.5 5±0.5 49.7±0.5 Lot No. seal *Heatsink for 30,50,100W:HAQ-10T Output Derating Output Load(%) Derating Curve 100 80 60 40 20 0 -40 -20 0 20 40 60 80 100 Baseplate temperature(℃) ・All specifications are subject to change without notice.  CN50A110 CN50A110 Specifications ITEMS/UNITS  MODEL Voltage Range V Input Efficiency(typ) (*1) % Current (*1) CN50A110-5 CN50A110-12 CN50A110-15 CN50A110-24 60 - 160 84 86 A 0.55 VDC 5 Maximum Current A 10 4.2 3.4 2.1 Maximum Power W 50 50.4 51.0 50.4 Output Maximum Line Regulation(*2) mV 20 48 60 96 Maximum Load Regulation(*3) mV 40 96 120 192 Nominal Voltage 12 Voltage Setting Accuracy (*1) % 0.02%/°C Maximum Ripple & Noise (*8) mVp-p 100 Voltage Adjustable Range (*8) VDC -10 / +20 Over Current Protection (*4) A Over Voltage Protection(*5)(*7) VDC Remote Sensing 150 240 -/+ 10 105 - 140 125 - 145 (Inverter shutdown method) Possible (*7) Possible (SHORT : ON OPEN : OFF) Remote ON/OFF Control  (*7) - Parallel Operation Possible Series Operation (*7) Operating Temperature (*6) ℃ -40 - +100 (Baseplate) Ambient Temperature min=-40°C ℃ -40 - +100 Operating Humidity % RH 5 - 95 (No Dewdrop) Storage Humidity % RH Storage Temperature 24 -/+ 1 Temperature Coefficient Function 15 Environment 5 - 95 (No Dewdrop) At No Operating, 10-55Hz (Sweep for 1min.) Amplitude 0.825mm Constant (Maximum 49.0m/s²) X,Y,Z 1 hour each Vibration IEC61373 - Categoly 1 - Grade B 196.1m/s² Shock Conduction Cooled Cooling Isolation Input-Baseplate : 1.5kVAC, Input-Output : 3.0kVAC for 1min. Withstand Voltage Output-Baseplate : 500VAC for 1min. Isolation Resistance More than 100MΩ at 25°C and 70%RH Output-Baseplate…500VDC Standards Safety Standards Mechanical Weight(typ) Size (W×H×D) Approved by UL60950-1, CSA60950-1, EN60950-1 g 100 mm 36.8 x 12.7 x 57.9 (Refer to Outline Drawing) *1. At 110VDC and maximum output current. (Baseplate Temperature = +25°C) *2. 60 - 160VDC, Constant load. *3. No Load - Full Load, Constant input voltage. *4. 5V automatically shutdown when left in OCP condition, with the output voltage less than the LVP level. 12V, 15V and 24V constant current limiting with automatic recovery. LVP reset : Line off or Control off. *5. OVP reset : Line off or Control off. *6. Rating - Refer to Derating Curve on the right. - Load(%) is percent of maximum output current. - Refer to Instruction Manual. *7. Refer to Instruction Manual. *8. External components are needed for operation. (Refer to Basic Connection and Instruction Manual.)  ・All specifications are subject to change without notice. CN50A110 CN50A110 Outline Drawing ( unit:mm ) CL 57.9±0.5 6-Φ1  Input and signal terminals 2-Φ1.5  TRM +S +V 7.62±0.25 -S 15.24±0.25 -V +Vin +Vin -S CNT TRM 28±0.25 36.8±0.5 12.7±0.25 CNT CL -V +S -Vin -Vin +V Output terminals MADE IN JAPAN Name plate 2-M3 For mounting(FG) 12.7±0.5 5±0.5 49.7±0.5 Lot No. seal *Heatsink for 30,50,100W:HAQ-10T Output Derating Output Load(%) Derating Curve 100 80 60 40 20 0 -40 -20 0 20 40 60 80 100 Baseplate temperature(℃) ・All specifications are subject to change without notice.  CN100A110 CN100A110 Specifications ITEMS/UNITS  MODEL Voltage Range V Input Efficiency(typ) (*1) % Current (*1) Nominal Voltage CN100A110-5 CN100A110-12 CN100A110-15 CN100A110-24 60 - 160 85 88 A 1.08 1.05 VDC 5 12 15 24 Maximum Current A 20 8.4 6.7 4.2 Maximum Power W 100 100.8 100.5 100.8 Output Maximum Line Regulation(*2) mV 20 48 60 96 Maximum Load Regulation(*3) mV 40 96 120 192 Voltage Setting Accuracy (*1) % -/+ 1 0.02%/°C Temperature Coefficient Maximum Ripple & Noise (*8) mVp-p 100 Voltage Adjustable Range (*8) VDC -10 / +20 Over Current Protection (*4) A Remote Sensing 240 -/+ 10 105 - 140 Over Voltage Protection(*5)(*7) VDC Function 150 125 - 145 (Inverter shutdown method) Possible (*7) Possible (SHORT : ON OPEN : OFF) Remote ON/OFF Control  (*7) - Parallel Operation Possible Series Operation (*7) Operating Temperature (*6) ℃ Possible -40 - +100 (Baseplate) Ambient Temperature min=-40°C ℃ -40 - +100 Operating Humidity % RH 5 - 95 (No Dewdrop) Storage Humidity % RH Storage Temperature Environment 5 - 95 (No Dewdrop) At No Operating, 10-55Hz (Sweep for 1min.) Amplitude 0.825mm Constant (Maximum 49.0m/s²) X,Y,Z 1 hour each Vibration IEC61373 - Category 1 - Grade B 196.1m/s² Shock Conduction Cooled Cooling Isolation Withstand Voltage Input-Baseplate : 1.5kVAC (20mA), Input-Output : 3.0kVAC for 1min. (*9) Output-Baseplate : 500VAC for 1min (20mA). Isolation Resistance More than 100MΩ at 25°C and 70%RH Output-Baseplate…500VDC Standards Safety Standards Mechanical Weight(typ) Size (W×H×D) Approved by UL60950-1, CSA60950-1, EN60950-1 g 70 mm 36.8 x 12.7 x 57.9 (Refer to Outline Drawing) *1. At 110VDC and maximum output current. (Baseplate Temperature = +25°C) *2. 60 - 160VDC, Constant load. *3. No Load - Full Load, Constant input voltage. *4. 5V delay shutdown when left in OCP condition, with the output voltage less than the LVP level. 12V, 15V and 24V constant current limiting with automatic recovery. LVP reset : Line off or Control off. *5. OVP reset : Line off or Control off. *6. Rating - Refer to Derating Curve on the right. - Load(%) is percent of maximum output current. - Refer to Instruction Manual. *7. Refer to Instruction Manual. *8. External components are necessary for operation. (Refer to Basic Connection and Instruction Manual.) *9. This specification applies to power supply module as stand-alone.  ・All specifications are subject to change without notice. CN100A110 CN100A110 Outline Drawing ( unit:mm ) CL 57.9±0.5 6-Φ1  Input and signal terminals 2-Φ1.5  -S DC-DC TRM +Vin +Vin +S +V BAR CODE 7.62±0.25 CNT 15.24±0.25 -V -S 28±0.25 36.8±0.5 -V R CNT 12.7±0.25 2.5A 4.2A TRM -Vin CL INPUT:60-160V OUTPUT:24V +S CN100A110-24 -Vin +V Output terminals MADE IN JAPAN Name plate 2-M3 For mounting(FG) 12.7±0.5 5±0.5 49.7±0.5 Lot No. seal *Heatsink for 30,50,100W:HAQ-10T Output Derating Output Load(%) Derating Curve 100 80 60 40 20 0 -40 -20 0 20 40 60 80 100 Baseplate temperature(℃) ・All specifications are subject to change without notice.  CN200A110 CN200A110 Specifications ITEMS/UNITS  MODEL Voltage Range V Input Efficiency(typ) (*1) % Current (*1) Nominal Voltage CN200A110-5 CN200A110-12 CN200A110-15 CN200A110-24 60 - 160 85 88 A 2.16 2.09 2.10 2.11 VDC 5 12 15 24 Maximum Current A 40 16.7 13.4 8.4 Maximum Power W 200 200.4 201.0 201.6 Output Maximum Line Regulation(*2) mV 20 48 60 96 Maximum Load Regulation(*3) mV 40 96 120 192 Voltage Setting Accuracy (*1) % -/+ 1 0.02%/°C Temperature Coefficient Maximum Ripple & Noise (*8) mVp-p 100 Voltage Adjustable Range (*8) VDC -10 / +20 Over Current Protection (*4) A Over Voltage Protection(*5)(*7) VDC Function Remote Sensing 150 240 -/+ 10 105 - 140 125 - 145 (Inverter shutdown method) Possible (*7) Possible (SHORT : ON OPEN : OFF) Remote ON/OFF Control  (*7) Possible Parallel Operation (*7) Series Operation (*7) Operating Temperature (*6) ℃ Possible -40 - +100 (Baseplate) Ambient Temperature min=-40°C ℃ -40 - +100 Operating Humidity % RH 5 - 95 (No Dewdrop) Storage Humidity % RH Storage Temperature Environment 5 - 95 (No Dewdrop) At No Operating, 10-55Hz (Sweep for 1min.) Amplitude 0.825mm Constant (Maximum 49.0m/s²) X,Y,Z 1 hour each Vibration IEC61373 - Category 1 - Grade B 196.1m/s² Shock Conduction Cooled Cooling Isolation Input-Baseplate : 1.5kVAC, Input-Output : 3.0kVAC for 1min. Withstand Voltage Output-Baseplate : 500VAC for 1min. Isolation Resistance More than 100MΩ at 25°C and 70%RH Output-Baseplate…500VDC Standards Safety Standards Mechanical Weight(typ) Size (W×H×D) Designed to meet UL60950-1, CSA60950-1, EN60950-1 g 150 mm 61.0 x 12.7 x 57.9 (Refer to Outline Drawing) *1. At 110VDC and maximum output current. (Baseplate Temperature = +25°C) *2. 60 - 160VDC, Constant load. *3. No Load - Full Load, Constant input voltage. *4. 5V delay shutdown when left in OCP condition, with the output voltage less than the LVP level. 12V, 15V and 24V constant current limiting with automatic recovery. LVP reset : Line off or Control off. *5. OVP reset : Line off or Control off. *6. Rating - Refer to Derating Curve on the right. - Load(%) is percent of maximum output current. - Refer to Instruction Manual. *7. Refer to Instruction Manual. *8. External components are needed for operation. (Refer to Basic Connection and Instruction Manual.)  ・All specifications are subject to change without notice. CN200A110 CN200A110 Outline Drawing ( unit:mm ) CL +S +V 10.16 TRM 7.62 7.62 +Vin BAR CODE 10.16 CNT +Vin -V CNT -S 61±0.5 50.8±0.3 15.24 DC-DC 10.16 CL -S 4A 8.4A PC PC -V TRM 10.16 INPUT:60-160V OUTPUT:24V +S CN200A110-24 -Vin -Vin 2-Φ2.0 Output terminals +V 7-Φ1 Input and signal terminals MADE IN JAPAN 48.3±0.3 4-M3 For mounting(FG) 5±0.5 57.9±0.5 12.7±0.5 Name plate Lot No. seal *Heatsink for 200W:HAH-10T, HAH-10L, HAH-15L Output Derating Output Load(%) Derating Curve 100 80 60 40 20 0 -40 -20 0 20 40 60 80 100 Baseplate temperature(℃) ・All specifications are subject to change without notice.  Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TDK-Lambda: HAQ10T
HAQ10T 价格&库存

很抱歉,暂时无法提供与“HAQ10T”相匹配的价格&库存,您可以联系我们找货

免费人工找货