CN-A110 SERIES
Optimum DC-DC Power Module for
Railway Related Instruments
OTHERS
UL60950-1
CSA60950-1
EN60950-1
EN60950-1
(TUV) Low Voltage Directive
5
warranty
(CN200A110 is designed to meet)
■ Features
● Optimum wide input voltage range for Railway Related Instruments, input voltage: 60 to 160 VDC
●A
nti-vibration and shock resistance characteristics
Y
E
A
R
S
■ Model naming method
CN 100 A 110 - 5
Output voltage
Input voltage
conforming to IEC61373
● 5 years free warranty
Series name
● Brick shaped utilized (1/4 brick for 30W-50W-
Output power
100W, 1/2 brick for 200W)
Series name
■ Applications
■ Conformity to RoHS Directive
This means that, in conformity with EU Directive 2002/95/
EC, lead, cadmium, mercury, hexavalent chromium, and
specific bromine-based flame retardants, PBB and PBDE,
OTHERS
have not been used, except for exempted applications.
Y
■ Product
Line up
E
A
R
S
Output Voltage
warranty
Output Current
30W
50W
100W
200W
Model
Output Current
Model
Output Current
Model
Output Current
Model
5
6
CN30A110-5
10
CN50A110-5
20
CN100A110-5
40
CN200A110-5
12
2.5
CN30A110-12
4.2
CN50A110-12
8.4
CN100A110-12
16.7
CN200A110-12
15
2
CN30A110-15
3.4
CN50A110-15
6.7
CN100A110-15
13.4
CN200A110-15
24
1.3
CN30A110-24
2.1
CN50A110-24
4.2
CN100A110-24
8.4
CN200A110-24
・All specifications are subject to change without notice.
CN30A110
CN30A110 Specifications
ITEMS/UNITS
MODEL
Voltage Range
V
Input Efficiency(typ)
(*1) %
Current
(*1)
CN30A110-5
CN30A110-12
CN30A110-15
60 - 160
83
84
A
0.34
VDC
5
12
15
Maximum Current
A
6
2.5
2
Maximum Power
W
Nominal Voltage
CN30A110-24
30
Voltage Setting Accuracy (*1) %
24
1.3
31.2
-/+ 1
Output Maximum Line Regulation(*2) mV
20
48
60
96
Maximum Load Regulation(*3) mV
40
96
120
192
0.02%/°C
Temperature Coefficient
Maximum Ripple & Noise (*8) mVp-p
100
Voltage Adjustable Range (*8) VDC
-10 / +20
Over Current Protection (*4)
A
Over Voltage Protection(*5)(*7) VDC
Function
Remote Sensing
150
240
-/+ 10
105 - 140
125 - 145 (Inverter shutdown method)
Possible
(*7)
Possible (SHORT : ON OPEN : OFF)
Remote ON/OFF Control (*7)
-
Parallel Operation
Possible
Series Operation
(*7)
Operating Temperature
(*6) ℃
-40 - +100 (Baseplate) Ambient Temperature min=-40°C
℃
-40 - +100
Operating Humidity
% RH
5 - 95 (No Dewdrop)
Storage Humidity
% RH
Storage Temperature
Environment
5 - 95 (No Dewdrop)
At No Operating, 10-55Hz (Sweep for 1min.)
Amplitude 0.825mm Constant (Maximum 49.0m/s²) X,Y,Z 1 hour each
Vibration
IEC61373 - Categoly 1 - Grade B
196.1m/s²
Shock
Conduction Cooled
Cooling
Isolation
Input-Baseplate : 1.5kVAC, Input-Output : 3.0kVAC for 1min.
Withstand Voltage
Output-Baseplate : 500VAC for 1min.
Isolation Resistance
More than 100MΩ at 25°C and 70%RH Output-Baseplate…500VDC
Standards Safety Standards
Mechanical
Weight(typ)
Size (W×H×D)
Approved by UL60950-1, CSA60950-1, EN60950-1
g
100
mm
36.8 x 12.7 x 57.9 (Refer to Outline Drawing)
*1. At 110VDC and maximum output current.
(Baseplate Temperature = +25°C)
*2. 60 - 160VDC, Constant load.
*3. No Load - Full Load, Constant input voltage.
*4. 5V automatically shutdown when left in OCP condition, with the output voltage less than the LVP level.
12V, 15V and 24V constant current limiting with automatic recovery.
LVP reset : Line off or Control off.
*5. OVP reset : Line off or Control off.
*6. Rating - Refer to Derating Curve on the right.
- Load(%) is percent of maximum output current.
- Refer to Instruction Manual.
*7. Refer to Instruction Manual.
*8. External components are needed for operation. (Refer to Basic Connection and Instruction Manual.)
・All specifications are subject to change without notice.
CN30A110
CN30A110 Outline Drawing
( unit:mm )
CL
57.9±0.5
6-Φ1
Input and signal terminals
2-Φ1.5
TRM
+S
+V
7.62±0.25
-S
15.24±0.25
-V
+Vin
+Vin
-S
CNT
TRM
28±0.25
36.8±0.5
12.7±0.25
CNT
CL
-V
+S
-Vin
-Vin
+V
Output terminals
MADE IN JAPAN
2-M3 For mounting
(FG)
Name plate
12.7±0.5
5±0.5
49.7±0.5
Lot No. seal
*Heatsink for 30,50,100W:HAQ-10T
Output Derating
Output Load(%)
Derating Curve
100
80
60
40
20
0
-40 -20 0 20 40 60 80 100
Baseplate temperature(℃)
・All specifications are subject to change without notice.
CN50A110
CN50A110 Specifications
ITEMS/UNITS
MODEL
Voltage Range
V
Input Efficiency(typ)
(*1) %
Current
(*1)
CN50A110-5
CN50A110-12
CN50A110-15
CN50A110-24
60 - 160
84
86
A
0.55
VDC
5
Maximum Current
A
10
4.2
3.4
2.1
Maximum Power
W
50
50.4
51.0
50.4
Output Maximum Line Regulation(*2) mV
20
48
60
96
Maximum Load Regulation(*3) mV
40
96
120
192
Nominal Voltage
12
Voltage Setting Accuracy (*1) %
0.02%/°C
Maximum Ripple & Noise (*8) mVp-p
100
Voltage Adjustable Range (*8) VDC
-10 / +20
Over Current Protection (*4)
A
Over Voltage Protection(*5)(*7) VDC
Remote Sensing
150
240
-/+ 10
105 - 140
125 - 145 (Inverter shutdown method)
Possible
(*7)
Possible (SHORT : ON OPEN : OFF)
Remote ON/OFF Control (*7)
-
Parallel Operation
Possible
Series Operation
(*7)
Operating Temperature
(*6) ℃
-40 - +100 (Baseplate) Ambient Temperature min=-40°C
℃
-40 - +100
Operating Humidity
% RH
5 - 95 (No Dewdrop)
Storage Humidity
% RH
Storage Temperature
24
-/+ 1
Temperature Coefficient
Function
15
Environment
5 - 95 (No Dewdrop)
At No Operating, 10-55Hz (Sweep for 1min.)
Amplitude 0.825mm Constant (Maximum 49.0m/s²) X,Y,Z 1 hour each
Vibration
IEC61373 - Categoly 1 - Grade B
196.1m/s²
Shock
Conduction Cooled
Cooling
Isolation
Input-Baseplate : 1.5kVAC, Input-Output : 3.0kVAC for 1min.
Withstand Voltage
Output-Baseplate : 500VAC for 1min.
Isolation Resistance
More than 100MΩ at 25°C and 70%RH Output-Baseplate…500VDC
Standards Safety Standards
Mechanical
Weight(typ)
Size (W×H×D)
Approved by UL60950-1, CSA60950-1, EN60950-1
g
100
mm
36.8 x 12.7 x 57.9 (Refer to Outline Drawing)
*1. At 110VDC and maximum output current.
(Baseplate Temperature = +25°C)
*2. 60 - 160VDC, Constant load.
*3. No Load - Full Load, Constant input voltage.
*4. 5V automatically shutdown when left in OCP condition, with the output voltage less than the LVP level.
12V, 15V and 24V constant current limiting with automatic recovery.
LVP reset : Line off or Control off.
*5. OVP reset : Line off or Control off.
*6. Rating - Refer to Derating Curve on the right.
- Load(%) is percent of maximum output current.
- Refer to Instruction Manual.
*7. Refer to Instruction Manual.
*8. External components are needed for operation. (Refer to Basic Connection and Instruction Manual.)
・All specifications are subject to change without notice.
CN50A110
CN50A110 Outline Drawing
( unit:mm )
CL
57.9±0.5
6-Φ1
Input and signal terminals
2-Φ1.5
TRM
+S
+V
7.62±0.25
-S
15.24±0.25
-V
+Vin
+Vin
-S
CNT
TRM
28±0.25
36.8±0.5
12.7±0.25
CNT
CL
-V
+S
-Vin
-Vin
+V
Output terminals
MADE IN JAPAN
Name plate
2-M3 For mounting(FG)
12.7±0.5
5±0.5
49.7±0.5
Lot No. seal
*Heatsink for 30,50,100W:HAQ-10T
Output Derating
Output Load(%)
Derating Curve
100
80
60
40
20
0
-40 -20 0 20 40 60 80 100
Baseplate temperature(℃)
・All specifications are subject to change without notice.
CN100A110
CN100A110 Specifications
ITEMS/UNITS
MODEL
Voltage Range
V
Input Efficiency(typ)
(*1) %
Current
(*1)
Nominal Voltage
CN100A110-5
CN100A110-12
CN100A110-15
CN100A110-24
60 - 160
85
88
A
1.08
1.05
VDC
5
12
15
24
Maximum Current
A
20
8.4
6.7
4.2
Maximum Power
W
100
100.8
100.5
100.8
Output Maximum Line Regulation(*2) mV
20
48
60
96
Maximum Load Regulation(*3) mV
40
96
120
192
Voltage Setting Accuracy (*1) %
-/+ 1
0.02%/°C
Temperature Coefficient
Maximum Ripple & Noise (*8) mVp-p
100
Voltage Adjustable Range (*8) VDC
-10 / +20
Over Current Protection (*4)
A
Remote Sensing
240
-/+ 10
105 - 140
Over Voltage Protection(*5)(*7) VDC
Function
150
125 - 145 (Inverter shutdown method)
Possible
(*7)
Possible (SHORT : ON OPEN : OFF)
Remote ON/OFF Control (*7)
-
Parallel Operation
Possible
Series Operation
(*7)
Operating Temperature
(*6) ℃
Possible
-40 - +100 (Baseplate) Ambient Temperature min=-40°C
℃
-40 - +100
Operating Humidity
% RH
5 - 95 (No Dewdrop)
Storage Humidity
% RH
Storage Temperature
Environment
5 - 95 (No Dewdrop)
At No Operating, 10-55Hz (Sweep for 1min.)
Amplitude 0.825mm Constant (Maximum 49.0m/s²) X,Y,Z 1 hour each
Vibration
IEC61373 - Category 1 - Grade B
196.1m/s²
Shock
Conduction Cooled
Cooling
Isolation
Withstand Voltage
Input-Baseplate : 1.5kVAC (20mA), Input-Output : 3.0kVAC for 1min.
(*9)
Output-Baseplate : 500VAC for 1min (20mA).
Isolation Resistance
More than 100MΩ at 25°C and 70%RH Output-Baseplate…500VDC
Standards Safety Standards
Mechanical
Weight(typ)
Size (W×H×D)
Approved by UL60950-1, CSA60950-1, EN60950-1
g
70
mm
36.8 x 12.7 x 57.9 (Refer to Outline Drawing)
*1. At 110VDC and maximum output current.
(Baseplate Temperature = +25°C)
*2. 60 - 160VDC, Constant load.
*3. No Load - Full Load, Constant input voltage.
*4. 5V delay shutdown when left in OCP condition, with the output voltage less than the LVP level.
12V, 15V and 24V constant current limiting with automatic recovery.
LVP reset : Line off or Control off.
*5. OVP reset : Line off or Control off.
*6. Rating - Refer to Derating Curve on the right.
- Load(%) is percent of maximum output current.
- Refer to Instruction Manual.
*7. Refer to Instruction Manual.
*8. External components are necessary for operation. (Refer to Basic Connection and Instruction Manual.)
*9. This specification applies to power supply module as stand-alone.
・All specifications are subject to change without notice.
CN100A110
CN100A110 Outline Drawing
( unit:mm )
CL
57.9±0.5
6-Φ1
Input and signal terminals
2-Φ1.5
-S
DC-DC
TRM
+Vin
+Vin
+S
+V
BAR CODE
7.62±0.25
CNT
15.24±0.25
-V
-S
28±0.25
36.8±0.5
-V
R
CNT
12.7±0.25
2.5A
4.2A
TRM
-Vin
CL
INPUT:60-160V
OUTPUT:24V
+S
CN100A110-24
-Vin
+V
Output terminals
MADE IN JAPAN
Name plate
2-M3 For mounting(FG)
12.7±0.5
5±0.5
49.7±0.5
Lot No. seal
*Heatsink for 30,50,100W:HAQ-10T
Output Derating
Output Load(%)
Derating Curve
100
80
60
40
20
0
-40 -20 0 20 40 60 80 100
Baseplate temperature(℃)
・All specifications are subject to change without notice.
CN200A110
CN200A110 Specifications
ITEMS/UNITS
MODEL
Voltage Range
V
Input Efficiency(typ)
(*1) %
Current
(*1)
Nominal Voltage
CN200A110-5
CN200A110-12
CN200A110-15
CN200A110-24
60 - 160
85
88
A
2.16
2.09
2.10
2.11
VDC
5
12
15
24
Maximum Current
A
40
16.7
13.4
8.4
Maximum Power
W
200
200.4
201.0
201.6
Output Maximum Line Regulation(*2) mV
20
48
60
96
Maximum Load Regulation(*3) mV
40
96
120
192
Voltage Setting Accuracy (*1) %
-/+ 1
0.02%/°C
Temperature Coefficient
Maximum Ripple & Noise (*8) mVp-p
100
Voltage Adjustable Range (*8) VDC
-10 / +20
Over Current Protection (*4)
A
Over Voltage Protection(*5)(*7) VDC
Function
Remote Sensing
150
240
-/+ 10
105 - 140
125 - 145 (Inverter shutdown method)
Possible
(*7)
Possible (SHORT : ON OPEN : OFF)
Remote ON/OFF Control (*7)
Possible
Parallel Operation
(*7)
Series Operation
(*7)
Operating Temperature
(*6) ℃
Possible
-40 - +100 (Baseplate) Ambient Temperature min=-40°C
℃
-40 - +100
Operating Humidity
% RH
5 - 95 (No Dewdrop)
Storage Humidity
% RH
Storage Temperature
Environment
5 - 95 (No Dewdrop)
At No Operating, 10-55Hz (Sweep for 1min.)
Amplitude 0.825mm Constant (Maximum 49.0m/s²) X,Y,Z 1 hour each
Vibration
IEC61373 - Category 1 - Grade B
196.1m/s²
Shock
Conduction Cooled
Cooling
Isolation
Input-Baseplate : 1.5kVAC, Input-Output : 3.0kVAC for 1min.
Withstand Voltage
Output-Baseplate : 500VAC for 1min.
Isolation Resistance
More than 100MΩ at 25°C and 70%RH Output-Baseplate…500VDC
Standards Safety Standards
Mechanical
Weight(typ)
Size (W×H×D)
Designed to meet UL60950-1, CSA60950-1, EN60950-1
g
150
mm
61.0 x 12.7 x 57.9 (Refer to Outline Drawing)
*1. At 110VDC and maximum output current.
(Baseplate Temperature = +25°C)
*2. 60 - 160VDC, Constant load.
*3. No Load - Full Load, Constant input voltage.
*4. 5V delay shutdown when left in OCP condition, with the output voltage less than the LVP level.
12V, 15V and 24V constant current limiting with automatic recovery.
LVP reset : Line off or Control off.
*5. OVP reset : Line off or Control off.
*6. Rating - Refer to Derating Curve on the right.
- Load(%) is percent of maximum output current.
- Refer to Instruction Manual.
*7. Refer to Instruction Manual.
*8. External components are needed for operation. (Refer to Basic Connection and Instruction Manual.)
・All specifications are subject to change without notice.
CN200A110
CN200A110 Outline Drawing
( unit:mm )
CL
+S
+V
10.16
TRM
7.62
7.62
+Vin
BAR CODE
10.16
CNT
+Vin
-V
CNT
-S
61±0.5
50.8±0.3
15.24
DC-DC
10.16
CL
-S
4A
8.4A
PC
PC
-V
TRM
10.16
INPUT:60-160V
OUTPUT:24V
+S
CN200A110-24
-Vin
-Vin
2-Φ2.0 Output terminals
+V
7-Φ1 Input and signal terminals
MADE IN JAPAN
48.3±0.3
4-M3 For mounting(FG)
5±0.5
57.9±0.5
12.7±0.5
Name plate
Lot No. seal
*Heatsink for 200W:HAH-10T, HAH-10L, HAH-15L
Output Derating
Output Load(%)
Derating Curve
100
80
60
40
20
0
-40 -20 0 20 40 60 80 100
Baseplate temperature(℃)
・All specifications are subject to change without notice.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TDK-Lambda:
HAQ10T