KWD5-1515

KWD5-1515

  • 厂商:

    TDK(东电化)

  • 封装:

    DIP-6

  • 描述:

    5W双输出AC/DC转换器

  • 数据手册
  • 价格&库存
KWD5-1515 数据手册
*This catalog is for KS and KWS series.) KS/KWS/KWD SERIES KWD Dual Output AC/DC Converter 5W-15W 1 Y E A R warranty KWD15 KWD10 KWS15 KWD5 KWS10 ks その他 KWS5 計 測 F A 医 療 ph KWS Single Output AC/DC Converter 5W-15W 半導体 その他 KS Single Output AC/DC Converter 5W-15W KS10 pf-a KS5 コンピュータ 通 信 F A ● On board type AC/DC converter, making full use of hk-a SMT technology, and reduction in size and weight is pursued. ● Functions of over current protection (OCP) and over voltage protection (OVP) equipped. hws ● AC100Vin and single-output type (KS series) コンピュータ ● Worldwide-applicable input and single output (KWS通 信 series) ● Worldwide-applicable input and dual output (KWD フォーマット series) ● Internal capacitor: Aluminum electrolytic (input smoothing), organic semiconductor electrolytic (output smoothing), ceramic コンピュータ 通 信 ■ Product Line updlp KS(Single output, AC100Vin) コンピュータ 1.0A 12V 0.45A Output voltage Output power Series name 5VDC, 12VDC 5W, 10W, 15W KS, KWS, KWD その他 ■ Applications 医 療 計 測 F A 半導体 This means that, in conformity with EU Directive 2002/95/ 医 療 計 測 F A 半導体 EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except forその他 exempted applications. 通 信 医 療 計 測 F A 半導体 10W fps 15W Model Output Current Model Output Current Model KS5-5 2.0A KS10-5 3.0A KS15-5 1.3A KS15-12 KS5-12 0.9A コンピュータ KWS(Single output, AC100/200Vin) Output Voltage ■ Model naming method KS 5 − 5 5W 5V 半導体 ■ Conformity to RoHS Directive その他 alpha Output Current 1 Y E A R warranty その他 ■ Features Output Voltage 1 Y E A R warranty その他 KS15 KS KWS KWD 通 信 その他 KS10-12 医 療 5W 計 測 F A 半導体 10W 15W Output Current Model Output Current Model Output Current Model 5V 1.0A KWS5-5 2.0A KWS10-5 3.0A KWS15-5 12V 0.45A KWS5-12 0.9A KWS10-12 1.3A KWS15-12 15V 0.35A KWS5-15 0.7A KWS10-15 1A KWS15-15 Output Current Model Output Current Model Output Current Model ±12V 0.22A KWD5-1212 0.45A KWD10-1212 0.65A KWD15-1212 ±15V 0.18A KWD5-1515 0.36A KWD10-1515 0.52A KWD15-1515 KWD(Dual output, AC100/200Vin) Output Voltage 5W ・All specifications are subject to change without notice. 10W 15W web190411 B-47 KS5 KS5 Specifications ITEMS/UNITS MODEL Voltage Range (*2) Frequency (*2) Hz Input Efficiency (typ) Current (100VAC)(typ) KS KWS KWD (*1) AC85 - 132 or DC110 - 175 47 - 440Hz 67 Minimum Current A 15 at Ta = 25℃ 5 Maximum Current A 1.0 0.45 W 5.0 5.4 Maximum Line Regulation (*3)(*4) mV 20 48 Maximum Load Regulation (*3)(*5) mV 40 96 Fixed ±5% (Max) Voltage Setting Accuracy Temperature Coefficient (*3)(*6) 50 120 Maximum Ripple & Noise (*3) mVp-p 120 150 ms 17 at 5W, Ta = 25℃ Over Current Protection (*7) >105% Over Voltage Protection (*8) >110% Parallel Operation No Series Operation Yes Storage Temperature Environment Storage Humidity ℃ -10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%) ℃ -30 to 85 %RH 30 - 90 (No dewdrop) %RH 20 - 95 (No dewdrop) 10 - 55Hz, constant amplitude 1.65mmp-p (Max98.1m/s2), sweep 1 minute X, Y, Z 1 hour each Vibration Less than 490.3m/s2 for 11±5ms on ±(X, Y, Z) axis each 3 times Shock Cooling Convection cooling Input - Output : 2kVAC(20mA), Input - FG : 2kVAC(20mA) Withstand Voltage Output - FG : 500VAC(100mA) for 1 minute each Isolation Resistance Mechanical 12 0 Maximum Power Operating Humidity Standards 69 0.2 A VDC Operating Temperature Isolation KS5-12 A Nominal Voltage Hold-up Time (100VAC)(typ) Function V (*1) % Inrush Current (100VAC)(typ) Output KS5-5 More than 100MΩ at 25℃ and 70%RH, Output - FG 500VDC Safety Standards Approved by UL60950 - 1 & CSA C22.2 No.60950-1, Built to meet DENAN EMI Weight Size (W x H x D) Built to meet VCCI - Class A & FCC class B g 70 mm 43 x 19.5 x 48 (*1) At 100VAC and maximum output power, Ta = 25℃. Measurement point for Vo, load/line reguration (*2) For cases where conformance to various safety specs (UL, CSA) are required, to be described as 100 - 120VAC, 50/60Hz on name plate. (*3) Please refer to Fig. A for measurement determination of line & load regulation and output ripple & noise voltage. (*4) From 85 - 132VAC, constant load. Measurement point for output ripple & noise (JEITA RC-9002A probe) C=0.1uF Film Cap. KS (*5) From min load - full load (maximum power), constant input voltage. (*6) From 0 to 50℃, constant input voltage and load. (*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. (*8) Over voltage clamping by zener diode. L=50mm Bandwidth of scope 100MHz Fig.A Output Derating LOAD (%) 100 80 60 40 25% 20 0 − 10 0 B-48 10 20 30 40 50 60 70 Ta (℃) ・All specifications are subject to change without notice. KS10 KS10 Specifications ITEMS/UNITS Input Output Function Environment Isolation MODEL Voltage Range (*2) Frequency (*2) Efficiency (typ) (*1) Current (100VAC)(typ) (*1) Inrush Current (100VAC)(typ) Nominal Voltage Minimum Current Maximum Current Maximum Power Voltage Setting Accuracy Maximum Line Regulation (*3)(*4) Maximum Load Regulation (*3)(*5) Temperature Coefficient (*3)(*6) Maximum Ripple & Noise (*3) Hold-up Time (100VAC)(typ) Over Current Protection (*7) Over Voltage Protection (*8) Parallel Operation Series Operation Operating Temperature Storage Temperature Operating Humidity Storage Humidity Vibration Shock Cooling V Hz % A A VDC A A W % mV mV mVp-p ms ℃ ℃ %RH %RH Withstand Voltage Isolation Resistance Safety Standards Standards EMI Weight Mechanical Size (W x H x D) KS10-5 KS10-12 AC85 - 132 or DC110 - 175 47 - 440Hz 73 74 0.3 10 at Ta = 25℃, cold start 5 12 0 2.0 10.0 Fixed ±5% (Max) 20 40 50 120 0.9 10.8 48 96 120 150 KS KWS KWD 17 at 10W, Ta = 25℃ >105% >110% No Yes -10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%) -30 to 85 30 - 90 (No dewdrop) 20 - 95 (No dewdrop) 10 - 55Hz, constant amplitude 1.65mmp-p (max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each Less than 490.3m/s2 for 11±5mS on ±(X, Y, Z) axis each 3 times Convection cooling Input - Output : 2kVAC (20mA), Input - FG : 2kVAC (20mA) Output - FG : 500VAC (100mA) for 1 minute each More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC Approved by UL60950 - 1 & CSA C22.2 No.60950-1, Built to meet DENAN Built to meet VCCI - Class A & FCC class B 85 45 x 20.5 x 55 g mm Measurement point for Vo, load / line reguration (*1) At 100VAC and maximum output power, Ta = 25℃. (*2) For cases where conformance to various safety specs (UL, CSA) are required, to be described as 100 - 120VAC, 50/60Hz on name plate. (*3) Please refer to Fig. A for measurement determination of line & load regulation and output ripple & noise voltage. (*4) From 85 - 132VAC, constant load. -V KS (*5) From min load - full load (maximum power), constant input voltage. (*6) From 0 to +50℃, constant input voltage and load. C=0.1uF Film Cap. Measurement point for output ripple & noise (JEITA RC-9002A probe) A +V (*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. L=50mm (*8) Over voltage clamping by zener diode. Bandwidth of scope 100MHz Fig.A Output Derating LOAD (%) 100 80 60 40 25% 20 0 − 10 0 10 20 30 40 50 60 70 Ta (℃) ・All specifications are subject to change without notice. B-49 KS15 KS15 ITEMS/UNITS Input Output KS KWS KWD Function Environment Isolation KS15 Specifications MODEL Voltage Range (*2) Frequency (*2) Efficiency (typ) (*1) Current (100VAC)(typ) (*1) Inrush Current (100VAC)(typ) Nominal Voltage Minimum Current Maximum Current Maximum Power Voltage Setting Accuracy Maximum Line Regulation (*3)(*4) Maximum Load Regulation (*3)(*5) Temperature Coefficient (*3)(*6) Maximum Ripple & Noise (*3) Hold-up Time (100VAC)(typ) Over Current Protection (*7) Over Voltage Protection (*8) Parallel Operation Series Operation Operating Temperature (*9) Storage Temperature Operating Humidity Storage Humidity Vibration (*10) Shock Cooling V Hz % A A VDC A A W % mV mV mV mVp-p ms ℃ ℃ %RH %RH Withstand Voltage Isolation Resistance Safety Standards Standards EMI Weight Mechanical Size (W x H x D) KS15-5 KS15-12 AC85 - 132 or DC110 - 175 47 - 440 74 76 0.4 10 at Ta = 25℃, cold start 5 12 0 3.0 15.0 Fixed ± 5% (Max) 20 40 50 120 1.3 15.6 48 96 120 150 17 at 15W, Ta = 25℃ >105% >110% No Yes -10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%) -30 to 85 30 - 90 (No dewdrop) 20 - 95 (No dewdrop) 10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each Less than 490.3m/s2 for 11±5mS on ±(X, Y, Z) axis each 3 times Convection cooling Input - Output : 2kVAC (20mA), Input - FG : 2kVAC (20mA) Output - FG : 500VAC (100mA) for 1minute each More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC Approved by UL60950 - 1 & CSA C22.2 No.60950-1, Built to meet DENAN Built to meet VCCI-Class A & FCC class B 100 45 x 20.5 x 64 g mm Measurement point for Vo, load / line reguration (*1) At 100VAC and maximum output power, Ta = 25℃. (*2) For cases where conformance to various safety specs (UL, CSA) are required to be described as 100 - 120VAC, 50/60Hz on name plate. (*3) Please refer to Fig. A for measurement determination of line & load regulation and output ripple & noise voltage. (*4) From 85 - 132VAC or 110 - 175VDC, constant load. -V KS (*5) From min load - full load (maximum power), constant input voltage. (*6) From 0 to +50℃, constant input voltage and load. C=0.1uF Film Cap. Measurement point for output ripple & noise (JEITA RC-9002A probe) A +V (*7) Current limiting with automatic recovery. Avioid to operate over load or dead short for more than 30 seconds. L=50mm (*8) Over voltage clamping by zener diode. Bandwidth of scope 100MHz Fig.A Output Derating LOAD (%) 100 80 60 40 25% 20 0 − 10 0 10 20 30 40 50 60 70 Ta (℃) B-50 ・All specifications are subject to change without notice. KS SERIES Outline Drawing 【KS5】 *TERMINAL ASSIGNMENTS  ①…FG  ②…AC(N)  ③…AC(L)  ④…-V NAME PLATE  ⑤…+V INPUT OUTPUT *MATERIAL  CASE:PLASTIC(UL94V-0) KS KWS KWD (unit:mm) 【KS10】 *TERMINAL ASSIGNMENTS  ①…FG  ②…AC(N)  ③…AC(L) NAME PLATE  ④…-V  ⑤…+V INPUT OUTPUT *MATERIAL  CASE:PLASTIC(UL94V-0) (unit:mm) 【KS15】 *TERMINAL ASSIGNMENTS  ①…FG  ②…AC(N)  ③…AC(L) NAME PLATE  ④…-V  ⑤…+V INPUT OUTPUT   *MATERIAL  CASE:PLASTIC(UL94V-0) (unit:mm) ・All specifications are subject to change without notice. B-51 KS 5 KWS KWS5 Specifications ITEMS/UNITS Input Output KS KWS KWD Function Environment Isolation MODEL Voltage Range (*2) Frequency (*2) Efficiency (typ) (*1) Current (100VAC)(typ) (*1) Inrush Current (100/200VAC)(typ) Nominal Voltage Minimum Current Maximum Current Maximum Power Voltage Setting Accuracy Maximum Line Regulation (*3)(*4) Maximum Load Regulation (*3)(*5) Temperature Coefficient (*3)(*6) Maximum Ripple & Noise (*3) Hold-up Time (100VAC)(typ) Over Current Protection (*7) Over Voltage Protection (*8) Parallel Operation Series Operation Operating Temperature Storage Temperature Operating Humidity Storage Humidity Vibration Shock Cooling Withstand Voltage Isolation Resistance Safety Standards Standards EMI Weight Mechanical Size (W x H x D) KWS5-5 KWS5-12 KWS5-15 V Hz % A A VDC A A W % mV mV mV mVp-p ms AC85 - 265 or DC110 - 340 47 - 440 67 70 0.2 15 / 30 5 12 15 0 1.0 0.45 0.35 5.0 5.4 5.25 Fixed ±5% (Max) 20 48 60 40 96 120 50 120 150 120 150 17 at 5W, Ta=25℃ >105% >110% No Possible ℃ -10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%) ℃ -30 to 85 %RH 30 - 90 (No dewdrop) %RH 20 - 95 (No dewdrop) 10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each Less than 490.3m/s2 for 11 ± 5ms on ± (X, Y, Z) axis each 3 times Convection cooling Input-Output : 3kVAC (20mA), Input-FG : 2kVAC (20mA) Output-FG : 500VAC (100mA) for 1 minute each More than 100MΩ at 25℃ and 70% RH Output-FG 500VDC Approved by UL60950-1, CSA C22.2 No.60950-1 & EN60950 Built to meet VCCI-Class A & FCC class B & VDE class B 75 45 x 20.5 x 55 (*9) g mm (*1) At 100VAC and maximum output power, Ta=25℃. Measurement point for Vo, load / line reguration (*2) For cases where conformance to various safety specs (UL, CSA, TUV) are required, to be described as 100 - 240VAC, 50/60Hz on name plate. (*3) Please refer to Fig. A for measurement determination of line & load regulation and output ripple & noise voltage. (*4) From 85 - 265VAC, constant load. -V C=0.1uF Film Cap. KWS (*5) From min load - full load (maximum power), constant input voltage. Measurement point for output ripple & noise (JEITA RC-9002A probe) A (*6) From 0 to 50℃, constant input voltage and load. (*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. +V (*8) Over voltage clamping by zener diode. L=50mm (*9) VDE class-B with external capacitor. Bandwidth of scope 100MHz Fig.A Output Derating LOAD (%) 100 80 60 40 25% 20 0 − 10 0 10 20 30 40 50 60 70 Ta (℃) B-52 ・All specifications are subject to change without notice. KS 10 KWS KWS10 Specifications ITEMS/UNITS Input Output Function Environment Isolation MODEL Voltage Range (*2) Frequency (*2) Efficiency (typ) (*1) Current (100VAC)(typ) (*1) Inrush Current (100/200VAC)(typ) Nominal Voltage Minimum Current Maximum Current Maximum Power Voltage Setting Accuracy Maximum Line Regulation (*3)(*4) Maximum Load Regulation (*3)(*5) Temperature Coefficient (*3)(*6) Maximum Ripple & Noise (*3) Hold-up Time (100VAC)(typ) Over Current Protection (*7) Over Voltage Protection (*8) Parallel Operation Series Operation Operating Temperature Storage Temperature Operating Humidity Storage Humidity Vibration Shock Cooling Withstand Voltage Isolation Resistance Safety Standards Standards EMI Weight Mechanical Size (W x H x D) KWS10-5 KWS10-12 KWS10-15 V Hz % A A VDC A A W % mV mV mV mVp-p ms AC85 - 265 or DC110 - 340 47 - 440 73 75 0.3 15 / 30 5 12 15 0 2.0 0.9 0.7 10.0 10.8 10.5 Fixed ±5% (Max) 20 48 60 40 96 120 50 120 150 120 150 17 at 10W, Ta=25℃ >105% >110% No Possible ℃ -10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%) ℃ -30 to 85 %RH 30 - 90 (No dewdrop) %RH 20 - 95 (No dewdrop) 10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each Less than 490.3m/s2 for 11±5ms on ± (X, Y, Z) axis each 3 times Convection cooling Input-Output : 3kVAC (20mA), Input-FG : 2kVAC (20mA) KS KWS KWD Output-FG : 500VAC (100mA) for 1 minute each More than 100MΩ at 25℃ and 70% RH Output-FG 500VDC Approved by UL60950-1, CSA C22.2 No.60950-1 & EN60950 Built to meet VCCI-Class A & FCC class B & VDE class B 100 45 x 20.5 x 64 (*9) g mm Measurement point for Vo, load / line reguration (*1) At 100VAC and maximum output power, Ta=25℃. (*2) For cases where conformance to various safety specs (UL, CSA, TUV) are required, to be described as 100 - 240VAC, 50/60Hz on name plate. (*3) Please refer to Fig. A for measurement determination of line & load regulation and output ripple & noise voltage. (*4) From 85 - 265VAC, constant load. -V KWS (*5) From min load - full load (maximum power), constant Input voltage. (*6) From 0 to +50℃, constant input voltage and load. C=0.1uF Film Cap. A +V (*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. L=50mm (*8) Over voltage clamping by zener diode. (*9) VDE class-B with external capacitor. Measurement point for output ripple & noise (JEITA RC-9002A probe) Bandwidth of scope 100MHz Fig.A Output Derating LOAD (%) 100 80 60 40 25% 20 0 − 10 0 10 20 30 40 50 60 70 Ta (℃) ・All specifications are subject to change without notice. B-53 KS 15 KWS KWS15 ITEMS/UNITS Input Output KS KWS KWD Function Environment Isolation KWS15 Specifications MODEL (*2) Voltage Range (*2) Frequency (*1) Efficiency (typ) (*1) Current (100VAC)(typ) Inrush Current (100/200VAC)(typ) Nominal Voltage Minimum Current Maximum Current Maximum Power Voltage Setting Accuracy Maximum Line Regulation(*3)(*4) Maximum Load Regulation (*3)(*5) Temperature Coefficient (*3)(*6) Maximum Ripple & Noise (*3) Hold-up Time (100VAC)(typ) Over Current Protection (*7) Over Voltage Protection (*8) Parallel Operation Series Operation Operating Temperature Storage Temperature Operating Humidity Storage Humidity Vibration Shock Cooling Withstand Voltage Isolation Resistance Safety Standards Standards EMI Weight Mechanical Size (W x H x D) KWS15-5 KWS15-12 KWS15-15 V Hz % A A VDC A A W % mV mV mV mVp-p ms AC85 - 265 or DC110 - 340 47 - 440 74 77 0.4 20 / 40 5 12 15 0 3 1.3 1.0 15.0 15.6 15 Fixed ±5% (Max) 20 48 60 40 96 120 50 120 150 120 150 17 at 15W, Ta=25℃ >105% >110% No Possible ℃ -10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%) ℃ -30 to 85 %RH 30 - 90 (No dewdrop) %RH 20 - 95 (No dewdrop) 10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each Less than 490.3m/s2 for 11±5ms on ± (X, Y, Z) axis each 3 times Convection cooling Input-Output : 3kVAC (20mA), Input-FG : 2kVAC (20mA) Output-FG : 500VAC (100mA) 1 min More than 100MΩ at 25℃ and 70% RH Output-FG 500VDC Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950 Built to meet VCCI-Class A & FCC class B & VDE class B 150 48 x 23.5 x 70 (*9) g mm Measurement point for Vo, load / line reguration (*1) At 100VAC and maximum output power, Ta=25℃. (*2) For cases where conformance to various safety specs (UL, CSA, TUV) are required, to be described as 100 - 240VAC, 50/60Hz on name plate. (*3) Please refer to Fig. A for measurement determination of line & load regulation and output ripple & noise voltage. -V KWS (*4) From 85 - 265VAC, constant load. (*5) From min load - full load (maximum power), constant input voltage. (*6) From 0 to 50℃, constant input voltage and load. C=0.1uF Film Cap. A +V (*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. (*8) Over voltage clamping by zener diode. L=50mm (*9) VDE class-B with external capacitor. Measurement point for output ripple & noise (JEITA RC-9002A probe) Bandwidth of scope 100MHz Fig.A Output Derating LOAD (%) 100 80 60 40 25% 20 0 − 10 0 10 20 30 40 50 60 70 Ta (℃) B-54 ・All specifications are subject to change without notice. KS SERIES KWS Outline Drawing 【KWS5】 *TERMINAL ASSIGNMENTS  ①…FG  ②…AC(N)  ③…AC(L) NAME PLATE  ④…-V  ⑤…+V INPUT OUTPUT   *MATERIAL  CASE:PLASTIC(UL94V-0)        KS KWS KWD (unit:mm) 【KWS10】 *TERMINAL ASSIGNMENTS  ①…FG  ②…AC(N)  ③…AC(L) NAME PLATE  ④…-V  ⑤…+V INPUT OUTPUT   *MATERIAL  CASE:PLASTIC(UL94V-0) (unit:mm) 【KWS15】 *TERMINAL ASSIGNMENTS  ①…FG  ②…AC(N)  ③…AC(L) NAME PLATE  ④…-V  ⑤…+V INPUT OUTPUT   *MATERIAL  CASE:PLASTIC(UL94V-0) (unit:mm) ・All specifications are subject to change without notice. B-55 KS 5 KWD KWD5 KWD5 Specifications MODEL ITEMS/UNITS Input KS KWS KWD Output Function Environment Isolation CH Voltage Range (*2) Frequency (*2) Efficiency (typ) (*1) Current (100VAC)(typ) (*1) Inrush Current (100/200VAC)(typ) Nominal Voltage Minimum Current Maximum Current Maximum Power Voltage Setting Accuracy Maximum Line Regulation (*3)(*4) Maximum Load Regulation (*3)(*5) Temperature Coefficient (*3)(*6) Maximum Ripple & Noise (*3) Hold-up Time (100VAC)(typ) Over Current Protection (*7) Over Voltage Protection (*8) Parallel Operation Series Operation Operating Temperature (*9) Storage Temperature Operating Humidity Storage Humidity Vibration Shock Cooling V Hz % A A VDC A A W % mV mV mV mVp-p ms ℃ ℃ %RH %RH Withstand Voltage Isolation Resistance Safety Standards Standards EMI Weight Mechanical Size (W x H x D) KWD5-1212 (*9) g mm 1 KWD5-1515 2 1 AC85 - 265 or DC110 - 340 47 - 440 69 2 69 0.2 15 / 30 at Ta = 25℃ -12 +15 0 0 0.22 0.18 +12 0 0.22 -15 0 0.18 5.3 5.4 Fixed ±5% (Max) Fixed ±5% (Max) 60 60 75 75 600 600 750 750 120 120 150 150 150 150 150 150 17 at 5W, Ta = 25℃ >105% >110% -----------Possible -10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%) -30 to 85 30 - 90 (No dewdrop) 20 - 95 (No dewdrop) 10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each Less than 490.3m/s2 for 11±5mS on ±(X, Y, Z) axis each 3 times Convection cooling Input - Output : 3kVAC (20mA), Input - FG : 2kVAC (20mA), Output - FG : 500VAC (100mA) 1 min More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC Approved by UL60950 - 1, CSA C22.2 No.60950-1 & EN60950 Built to meet VCCI - Class B, FCC class B, VDE class B 75 45 x 20.5 x 55 Measurement point for Vo, load / line reguration (*1) At 100VAC and maximum output power, Ta = 25℃. (*2) For cases where conformance to various safety specs (UL, CSA, TUV) are required, to be described as 100 - 240VAC, 50/60Hz on name plate. (*3) Please refer to Fig. A for measurement determination of line & load regulation and output ripple & noise voltage. -V KWD (*4) From 85 - 265VAC constant load. (*5) From min load - full load (maximum power), constant input voltage. (*6) From 0 to 50℃, constant input voltage and load. COM +V (*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. (*8) Over voltage clamping by zener diode (on CH2 only). C=0.1uF Film Cap. C=0.1uF Film Cap. L=50mm (*9) VDE class B with external capacitor. Measurement point for output ripple & noise (JEITA RC-9002A probe) A A Bandwidth of scope 100MHz Fig.A Output Derating LOAD (%) 100 80 60 40 25% 20 0 − 10 0 10 20 30 40 50 60 70 Ta (℃) B-56 ・All specifications are subject to change without notice. KS 10 KWD KWD10 Specifications MODEL ITEMS/UNITS Input Output Function Environment Isolation Voltage Range (*2) Frequency (*2) Efficiency (typ) (*1) Current (100VAC)(typ) (*1) Inrush Current (100/200VAC)(typ) Nominal Voltage Minimum Current Maximum Current Maximum Power Voltage Setting Accuracy Maximum Line Regulation (*3)(*4) Maximum Load Regulation (*3)(*5) Temperature Coefficient (*3)(*6) Maximum Ripple & Noise (*3) Hold-up Time (100VAC)(typ) Over Current Protection (*7) Over Voltage Protection (*8) Parallel Operation Series Operation Operating Temperature Storage Temperature Operating Humidity Storage Humidity Vibration Shock Cooling CH 1 V Hz % A A VDC A A W % mV mV +12 0 mVp-p ms ℃ ℃ %RH %RH Withstand Voltage Isolation Resistance Safety Standards Standards EMI Weight Mechanical Size (W x H x D) KWD10-1212 (*9) g mm KWD10-1515 2 1 AC85 - 265 or DC110 - 340 47 - 440 72 0.3 15 / 30 at Ta = 25℃ -12 +15 0 0 0.45 10.8 2 -15 0 0.36 10.8 Fixed ±5% (Max) 60 75 75 600 750 750 120 150 150 150 150 150 17 at 5W, Ta = 25℃ >105% >110% -----------Possible -10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%) -30 to 85 30 - 90 (No dewdrop) 20 - 95 (No dewdrop) 10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each Less than 490.3m/s2 for 11±5mS on ±(X, Y, Z) axis each 3 times Convection cooling Input - Output : 3kVAC (20mA), Input - FG : 2kVAC (20mA), Output - FG : 500VAC (100mA) for 1 minute each More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC Approved by UL60950 - 1, CSA C22.2 No.60950-1 & EN60950 Built to meet VCCI - Class B, FCC class B, VDE class B 100 45 x 20.5 x 64 60 600 120 150 Measurement point for Vo, load / line reguration (*1) At 100VAC and maximum output power, Ta = 25℃. (*2) For cases where conformance to various safety specs (UL, CSA, TUV) are required, to be described as 100 - 240VAC, 50/60Hz on name plate. (*3) Please refer to Fig. A for measurement determination of line & load regulation and output ripple & noise voltage. -V KWD (*4) From 85 - 265VAC, constant load. (*5) From min load - full load (maximum power), constant input voltage. COM (*6) From 0 to +50℃, constant input voltage and load. +V (*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. (*8) Over voltage clamping by zener diode (on CH2 only). C=0.1uF Film Cap. C=0.1uF Film Cap. L=50mm (*9) VDE class B with external capacitor. KS KWS KWD Measurement point for output ripple & noise (JEITA RC-9002A probe) A A Bandwidth of scope 100MHz Fig.A Output Derating LOAD (%) 100 80 60 40 25% 20 0 − 10 0 10 20 30 40 50 60 70 Ta (℃) ・All specifications are subject to change without notice. B-57 KS 15 KWD KWD15 Specifications MODEL ITEMS/UNITS Input Output KS KWS KWD Function Environment Isolation CH Voltage Range (*2) Frequency (*2) Efficiency (typ) (*1) Current (100VAC)(typ) (*1) Inrush Current (100/200VAC)(typ) Nominal Voltage Minimum Current Maximum Current Maximum Power Voltage Setting Accuracy Maximum Line Regulation (*3)(*4) Maximum Load Regulation (*3)(*5) Temperature Coefficient (*3)(*6) Maximum Ripple & Noise (*3) Hold-up Time (100VAC)(typ) Over Current Protection (*7) Over Voltage Protection (*8) Parallel Operation Series Operation Operating Temperature Storage Temperature Operating Humidity Storage Humidity Vibration Shock Cooling V Hz % A A VDC A A W % mV mV mVp-p ms ℃ ℃ %RH %RH Withstand Voltage Isolation Resistance Safety Standards Standards EMI Weight Mechanical Size (W x H x D) KWD15-1212 1 KWD15-1515 2 1 AC85 - 265 or DC110 - 340 47 - 440 75 2 75 0.4 20 / 40 at Ta = 25℃ -12 +15 0 +12 0.65 15.6 -15 0.52 15.6 Fixed ±5% (Max) 60 75 75 600 750 750 120 150 150 150 150 150 17 at 5W, Ta = 25℃ >105% >110% -----------Possible -10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%) -30 to 85 30 - 90 (No dewdrop) 20 - 95 (No dewdrop) 10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each Less than 490.3m/s2 for 11±5mS on ±(X, Y, Z) axis each 3 times Convection cooling Input - Output : 3kVAC (20mA), Input - FG : 2kVAC (20mA), 60 600 120 150 Output - FG : 500VAC (100mA) for 1 minute each More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC Approved by UL60950 - 1, CSA C22.2 No.60950-1 & EN60950 Built to meet VCCI - Class B, ECC Class B, VDE class B 150 48 x 23.5 x 70 (Refer to outline drawing) (*9) g mm Measurement point for Vo, load / line reguration (*1) At 100VAC and maximum output power, Ta = 25℃. (*2) For cases where conformance to various safety specs (UL, CSA, TUV) are required, to be described as 100 - 240VAC, 50/60Hz on name plate. (*3) Please refer to Fig. A for measurement determination of line & load regulation and output ripple & noise voltage. -V KWD (*4) From 85 - 265VAC constant load. COM (*5) From min load - full load (maximum power), constant input voltage. (*6) From 0 to 50℃, constant input voltage and load. +V (*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds. (*8) Over voltage clamping by zener diode (on CH2 only). C=0.1uF Film Cap. C=0.1uF Film Cap. L=50mm (*9) VDE class B with external capacitor. Measurement point for output ripple & noise (JEITA RC-9002A probe) A A Bandwidth of scope 100MHz Fig.A Output Derating LOAD (%) 100 80 60 40 25% 20 0 −10 0 10 20 30 40 50 60 70 Ta (℃) B-58 ・All specifications are subject to change without notice. KS SERIES KWD Outline Drawing 【KWD5】 *TERMINAL ASSIGNMRNTS  ①…FG  ②…AC(N)  ③…AC(L) INPUT  ④…−V  ⑤…COM OUTPUT  ⑥…+V *MATERIAL  CASE:PLASTIC(UL94V-0)        KS KWS KWD (unit:mm) 【KWD10】 *TERMINAL ASSIGNMRNTS  ①…FG  ②…AC(N)  ③…AC(L) INPUT  ④…−V  ⑤…COM OUTPUT  ⑥…+V *MATERIAL  CASE:PLASTIC(UL94V-0)        (unit:mm) 【KWD15】 *TERMINAL ASSIGNMRNTS  ①…FG  ②…AC(N)  ③…AC(L) INPUT  ④…−V  ⑤…COM OUTPUT  ⑥…+V *MATERIAL  CASE:PLASTIC(UL94V-0)        (unit:mm) ・All specifications are subject to change without notice. B-59 KS KS/KWS/KWD SERIES Block Diagram N A − ●Topology‥Single-ended forward Type(ON/OFF) A Control KS KWS KWD Output OCP Oscillator FG + OVP 85 - 132VAC 110 - 175VAC Switching Input Rectifier & Filter Fuse Line Filter L Rectifier & Filter ■ KS SERIES Voltage Sensing ●Swtching Frequency‥KS5:330kHz(Fixed) KS10、KS15:200kHz(Fixed) ●Fuse Rating‥4A N A Output − OCP A Control Oscillator FG + OVP 85 - 265VAC 110 - 340VDC Switching Input Rectifier & Filter Fuse Line Filter L Rectifier & Filter ■ KWS SERIES Voltage Sensing ●Topology‥Fly back Type(ON/OFF) ●Swtching Frequency‥KWS5、KWS10:220kHz(Fixed) KWS15:200kHz(Fixed) ●Fuse Rating‥4A ■ KWD SERIES Output +V Rectifier & Filter N Switching 85 - 265VAC 110 - 340VAC Rectifier & Filter Input Line Filter L Fuse COM Rectifier & Filter A FG −V Control Oscillator OCP Voltage Sensing A ●Topology‥Fly back Type(ON/OFF) ●Swtching Frequency:KWD5、KWD10…200kHz(Fixed) KWD15…140kHz(Fixed) ●Fuse Rating…4A B-60 ・All specifications are subject to change without notice. KS/KWS/KWD SERIES KS/KWS/KWD Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT ● Check that input/output terminals are correctly connected according to instruction manual. ● KWS/KWD series are designed for 85-265VAC continuous input. No need to switch operation to 100VAC or 200VAC input voltage. ● KS series is designed for 85-132VAC input. If a 200VAC is input, the power supply unit will be damaged. 1. Terminal Explanation 1 KS/KWS (single output) KS KWS KWD Nameplate (upper side) (3) (5) (2) Bottom side (1) FG: AC IN (N): AC IN (L): DC OUT (-V): DC OUT (+V): Frame ground terminal for grounding AC input terminal (neutral line) AC input terminal (live line) fuse in line DC output terminal ("-" side) DC output terminal ("+" side) (1) (2) (3) (4) (5) (6) FG: AC IN (N): AC IN (L): -V: COM: +V: Frame ground terminal for grounding AC input terminal (neutral line) AC input terminal (live line) fuse in line CH2 output terminal (-) Ground terminal of CH1/CH2 CH1 output terminal (+) (4) 2 KWD (dual outputs) Nameplate (upper side) (3) (1) (2) (3) (4) (5) (6) (2) (5) Bottom side (4) (1) 2. Terminal Connecting Method 1 KS/KWS (single output)     AC input     KS series: 85-132VAC     KWS series: 85-265VAC     (Continuous input type) FG −V N Input ACIN Nameplate (upper side) L OUT Load +V ● A fuse in line of the power supply unit (L side of AC IN). ● KS series is designed for 85-132VAC input. If a 200VAC is input, the unit may be damaged. ● KWS series is designed for 85-256VAC continuous input. No need to switch. 2 KWD terminal (dual outputs)     AC input     85-265VAC     (Continuous input type) ● A fuse in line of the power supply unit (L side of AC IN). ● KWD series is designed for 85-256VAC continuous input and the input switching operation is not necessary. ・All specifications are subject to change without notice. FG N Input −V OUT Nameplate Load COM ACIN (upper side) OUT +V L Load B-61 KS/KWS/KWD SERIES 3. Explanation of Functions and Precautions 1 Over Current Protection (OCP) 6 Series/Parallel Operations OCP type is current limiting with automatic recovery. OCP For series operation, either (A) or (B) is possible. Please function operates when the output current exceeds 105% or above of OCP specifications. The output automatically recovers when the over current / shorted conditions is removed. Do not operate under overload or dead short conditions for more than 30 seconds, which could result in damage to the unit. connect a diode for by-pass when using method (A) of the series operation. Please use the diode whose rated forward current is equal or more than load current and the rated maximum reverse voltage is higher than the output voltage for each power supply. 3 Ripple The maximum ripple voltage value in the specifications is measured in the ripple measurement circuit designated by JEITA RC-9131 probe. When the load wire is long, connect a film capacitor, etc., to prevent the ripple at the load terminal from becoming large. Note that the accurate measurement is not possible if the probe ground lead of the oscilloscope is long in measurement. "Ripple measurement circuit" + − + − + − ex: KWD5-1212 +V AC (L) AC (N) +V COM AC (N) COM −V I1 I1 OUT +12V Load+12V Load0 Load0 Load−12V I(max) 0 :Maximum output current per channel IN IN I I OUT AC (L) +V AC (L) +V OUT +24V COM COM Load −V ex: KWD5-1212 −V 0 0 I≦I(max) 0 I≦I(max) 0 OUT +V OUT +V (N) AC COM (N) AC COM ex: KWD5-1212 +24V Load ex: KWD5-1212 ex: KWD5-1212 − I2 −V −12V I2 I1, I2≦I(max) 0 II(max) 0 : Maximum output current per channel 1, I2≦I(max) 0 ex: KWD5-1212 〔Two different outputs〕 IN 〔Two different outputs〕 (L) IN AC AC (L) Wire Film capacitor + − (B) OUT AC (L) (N) AC Measurement point of maximum ripple voltage + (B) (N) AC Measurement point of output voltage + − (A) ● KWD series 〔+/− Outputs〕 IN 〔+/− Outputs〕 IN 〔2 Serial outputs〕 − + − − (A) 〔2 Serial outputs〕 + − − LoadLoad + − + + − LoadLoad Power supply + + − Output Output terminal terminal Power supply Power supply + LoadLoad KS KWS KWD The over voltage protection (OVP) circuit with zener diode clamp system is built in. (In KWD series, OVP circuit is built into CH2 only.) Over 110% of nominal voltage will clamp the output. If the output voltage is lowered due to the over voltage application, the output will not resume. Replacement of the power supply unit is necessary. ● KS, KWS series Power supply Output Output terminal terminal 2 Over Voltage Protection (OVP) I1 I1 I2 I2 I0 I0 −V −V Pararel operation is not possible. +24V +24V +12V Load +12V Load Load 0 Load 0 I1、I2≦I(max) 0 I1、I2≦I(max) 0 Pararel operation is not possible. 4 EMI 7 Isolation Test KWS and KWD series are built to meet the VDE Class B standards by adding external capacitor between L and N on the input side. Refer to the recommended values below.   KWS5, KWD5: AC250V 0.22μF The insulation resistance between output and FG is more than 100MΩ at 500VDC. For safety operation, voltage setting of DC isolation tester must be done before the test. Ensure that it is fully discharged after the test. Between output and FG   KWS10, KWD10: AC250V 0.22μF   KWS15, KWD15: AC250V 0.33μF AC (L) AC (N) 5 Inrush Current KS10 and KS15 use power thermistor to protect the circuit from inrush current. In power thermistor, the suppressed current value changes depending on the temperature, and the inrush current may become large in conditions with high temperature or when restarting input soon after stopping it. B-62 +V COM -V FG 500VDC 8 Withstand Voltage This series is designed to withstand 2kVAC for between input and output, 2kVAC between input and FG, and 500VAC between output and FG each for 1 minute. When testing withstand voltage, set current limit or withstand voltage test equipment at 20mA. (Output-FG: 100mA) ・All specifications are subject to change without notice. KS/KWS/KWD SERIES The applied voltage must be gradually increased from zero to testing value and then gradually decrease for shut down. Input-FG (solid (solid line) line) Input-FG Input-Output (dotted (dotted line) line) Input-Output When timer is used, the power supply may be damaged by AC (L) AC (L) high impulse voltage at timer switch on and off. If a timer AC (N) AC (N) is used for measuring the test time, impulsive high voltage may be generated in applying and cutting off the voltage, causing damage to the unit. * 3kVAC between input and output for KWS/KWD series 2 KVAC KVAC 21 KVAC 22 KVAC MIN 1 MIN MIN 11 MIN (20mA) (20mA) (20mA) (20mA) KWD series series KWD +V +V COM COM −V −V FG FG KWD series series KWD Output-FG Output-FG AC (L) AC (L) AC (N) AC (N) 500KVAC 500KVAC MIN 11 MIN (100mA) (100mA) +V +V COM COM −V −V FG FG KS KWS KWD * For KS/KWS series, connect the +V and -V terminals of the output.  (KS/KWS series are not equipped with the COM terminal.) There is no restriction on mountintg direction but there should be enough consideration for airflow so that heat does not accumulate around the power module vicinity. Also note that the output derating is necessary when the ambient temperature is high, as shown in the figure in the right. Output current (%) 4. Output Derating 100 80 60 40 25% 20 0 −10 0 10 20 30 40 50 60 70 Ambient temperature (° C) 5. Recommended soldering/cleaning 1 Recommended soldering medhod 2 Recommended cleaning conditions The temperature conditions in soldering should be the following. Recommended cleaning conditions after soldering are shown below. ● Dip condition: 260℃, within 10 seconds   Pre-heat conditions: 110℃ for 30-40 seconds ● Soldering iron: 350℃ within 3 seconds ● Cleaning solvent    IPA (isopropyl alcohol) ● Cleaning procedure    Cleaning should be conducted with a method that does not cause intrusion of the cleaning fluid into the inside of the power supply unit. (Note that if the cleaning fluid intrudes into inside of the power supply unit, the reliability of the power supply may be impaired.)    Note) Consult us if your cleaning method is other than that recommended above. 6. Before concluding power module damage Check if the rated input voltage is connected. Check if the wiring of input and output are correct. Check if the pattern width connected to input/output is not too narrow. Ensure that a large capacitor is not connected on the output side. Please use within maximum capacitance shown below. KS5: 5V 100μF or lower, 12V 200μF or lower KS10: 5V 200μF or lower, 12V 400μF or lower KS15: 5V 400μF or lower, 12V 1,000μF or lower KWS5: 5V 2,000μF or lower, 12V/15V 200μF or lower KWS10: 5V 2,000μF or lower, 12V/15V 1,000μF or lower KWS15: 5V 2,000μF or lower, 12V/15V 1,000μF or lower KWD5: 800μF or lower KWD10: 1212 1,000μF or lower, 1515 500μF or lower KWD15: 1212 1,000μF or lower, 1515 1,000μF or lower ・All specifications are subject to change without notice. B-63 B-64 ALL-1006E web111014
KWD5-1515 价格&库存

很抱歉,暂时无法提供与“KWD5-1515”相匹配的价格&库存,您可以联系我们找货

免费人工找货
KWD5-1515
    •  国内价格
    • 1+432.83160
    • 200+172.70280
    • 500+166.93560
    • 1000+164.08440

    库存:0