*This catalog is for KS and KWS series.)
KS/KWS/KWD SERIES
KWD Dual Output
AC/DC Converter 5W-15W
1
Y
E
A
R
warranty
KWD15
KWD10
KWS15
KWD5
KWS10
ks
その他
KWS5
計 測
F A
医 療
ph
KWS Single Output
AC/DC Converter 5W-15W
半導体
その他
KS Single Output
AC/DC Converter 5W-15W
KS10
pf-a
KS5
コンピュータ
通 信
F A
● On board type AC/DC converter,
making full use of
hk-a
SMT technology, and reduction in size and weight
is pursued.
● Functions of over current protection (OCP) and over
voltage protection (OVP) equipped.
hws
● AC100Vin and single-output type
(KS series)
コンピュータ
● Worldwide-applicable input and single output
(KWS通 信
series)
● Worldwide-applicable input and dual output (KWD
フォーマット
series)
● Internal capacitor: Aluminum electrolytic (input
smoothing), organic semiconductor electrolytic (output smoothing), ceramic
コンピュータ
通 信
■ Product Line updlp
KS(Single output, AC100Vin)
コンピュータ
1.0A
12V
0.45A
Output voltage
Output power
Series name
5VDC, 12VDC
5W, 10W, 15W
KS, KWS, KWD
その他
■ Applications
医 療
計 測
F A
半導体
This
means
that, in
conformity
with EU Directive 2002/95/
医 療
計 測
F A
半導体
EC, lead, cadmium, mercury, hexavalent chromium, and
specific bromine-based flame retardants, PBB and PBDE,
have not been used, except forその他
exempted applications.
通 信
医 療
計 測
F A
半導体
10W
fps
15W
Model
Output Current
Model
Output Current
Model
KS5-5
2.0A
KS10-5
3.0A
KS15-5
1.3A
KS15-12
KS5-12
0.9A
コンピュータ
KWS(Single output, AC100/200Vin)
Output Voltage
■ Model naming method
KS 5 − 5
5W
5V
半導体
■ Conformity to RoHS
Directive
その他
alpha
Output Current
1
Y
E
A
R
warranty
その他
■ Features
Output Voltage
1
Y
E
A
R
warranty
その他
KS15
KS
KWS
KWD
通 信
その他
KS10-12
医 療
5W
計 測
F A
半導体
10W
15W
Output Current
Model
Output Current
Model
Output Current
Model
5V
1.0A
KWS5-5
2.0A
KWS10-5
3.0A
KWS15-5
12V
0.45A
KWS5-12
0.9A
KWS10-12
1.3A
KWS15-12
15V
0.35A
KWS5-15
0.7A
KWS10-15
1A
KWS15-15
Output Current
Model
Output Current
Model
Output Current
Model
±12V
0.22A
KWD5-1212
0.45A
KWD10-1212
0.65A
KWD15-1212
±15V
0.18A
KWD5-1515
0.36A
KWD10-1515
0.52A
KWD15-1515
KWD(Dual output, AC100/200Vin)
Output Voltage
5W
・All specifications are subject to change without notice.
10W
15W
web190411
B-47
KS5
KS5 Specifications
ITEMS/UNITS
MODEL
Voltage Range
(*2)
Frequency
(*2) Hz
Input Efficiency (typ)
Current (100VAC)(typ)
KS
KWS
KWD
(*1)
AC85 - 132 or DC110 - 175
47 - 440Hz
67
Minimum Current
A
15 at Ta = 25℃
5
Maximum Current
A
1.0
0.45
W
5.0
5.4
Maximum Line Regulation (*3)(*4) mV
20
48
Maximum Load Regulation (*3)(*5) mV
40
96
Fixed ±5% (Max)
Voltage Setting Accuracy
Temperature Coefficient (*3)(*6)
50
120
Maximum Ripple & Noise (*3) mVp-p
120
150
ms
17 at 5W, Ta = 25℃
Over Current Protection (*7)
>105%
Over Voltage Protection (*8)
>110%
Parallel Operation
No
Series Operation
Yes
Storage Temperature
Environment Storage Humidity
℃
-10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%)
℃
-30 to 85
%RH
30 - 90 (No dewdrop)
%RH
20 - 95 (No dewdrop)
10 - 55Hz, constant amplitude 1.65mmp-p (Max98.1m/s2), sweep 1 minute X, Y, Z 1 hour each
Vibration
Less than 490.3m/s2 for 11±5ms on ±(X, Y, Z) axis each 3 times
Shock
Cooling
Convection cooling
Input - Output : 2kVAC(20mA), Input - FG : 2kVAC(20mA)
Withstand Voltage
Output - FG : 500VAC(100mA) for 1 minute each
Isolation Resistance
Mechanical
12
0
Maximum Power
Operating Humidity
Standards
69
0.2
A
VDC
Operating Temperature
Isolation
KS5-12
A
Nominal Voltage
Hold-up Time (100VAC)(typ)
Function
V
(*1) %
Inrush Current (100VAC)(typ)
Output
KS5-5
More than 100MΩ at 25℃ and 70%RH, Output - FG 500VDC
Safety Standards
Approved by UL60950 - 1 & CSA C22.2 No.60950-1, Built to meet DENAN
EMI
Weight
Size (W x H x D)
Built to meet VCCI - Class A & FCC class B
g
70
mm
43 x 19.5 x 48
(*1) At 100VAC and maximum output power, Ta = 25℃.
Measurement point for
Vo, load/line reguration
(*2) For cases where conformance to various safety specs (UL, CSA) are required,
to be described as 100 - 120VAC, 50/60Hz on name plate.
(*3) Please refer to Fig. A for measurement determination of line & load regulation
and output ripple & noise voltage.
(*4) From 85 - 132VAC, constant load.
Measurement point for
output ripple & noise
(JEITA RC-9002A probe)
C=0.1uF
Film Cap.
KS
(*5) From min load - full load (maximum power), constant input voltage.
(*6) From 0 to 50℃, constant input voltage and load.
(*7) Current limiting with automatic recovery. Avoid to operate over load or dead short
for more than 30 seconds.
(*8) Over voltage clamping by zener diode.
L=50mm
Bandwidth of scope
100MHz
Fig.A
Output Derating
LOAD
(%)
100
80
60
40
25%
20
0
− 10 0
B-48
10 20 30 40 50 60 70
Ta
(℃)
・All specifications are subject to change without notice.
KS10
KS10 Specifications
ITEMS/UNITS
Input
Output
Function
Environment
Isolation
MODEL
Voltage Range
(*2)
Frequency
(*2)
Efficiency (typ)
(*1)
Current (100VAC)(typ)
(*1)
Inrush Current (100VAC)(typ)
Nominal Voltage
Minimum Current
Maximum Current
Maximum Power
Voltage Setting Accuracy
Maximum Line Regulation (*3)(*4)
Maximum Load Regulation (*3)(*5)
Temperature Coefficient (*3)(*6)
Maximum Ripple & Noise (*3)
Hold-up Time (100VAC)(typ)
Over Current Protection (*7)
Over Voltage Protection (*8)
Parallel Operation
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Cooling
V
Hz
%
A
A
VDC
A
A
W
%
mV
mV
mVp-p
ms
℃
℃
%RH
%RH
Withstand Voltage
Isolation Resistance
Safety Standards
Standards
EMI
Weight
Mechanical
Size (W x H x D)
KS10-5
KS10-12
AC85 - 132 or DC110 - 175
47 - 440Hz
73
74
0.3
10 at Ta = 25℃, cold start
5
12
0
2.0
10.0
Fixed ±5% (Max)
20
40
50
120
0.9
10.8
48
96
120
150
KS
KWS
KWD
17 at 10W, Ta = 25℃
>105%
>110%
No
Yes
-10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%)
-30 to 85
30 - 90 (No dewdrop)
20 - 95 (No dewdrop)
10 - 55Hz, constant amplitude 1.65mmp-p (max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each
Less than 490.3m/s2 for 11±5mS on ±(X, Y, Z) axis each 3 times
Convection cooling
Input - Output : 2kVAC (20mA), Input - FG : 2kVAC (20mA)
Output - FG : 500VAC (100mA) for 1 minute each
More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC
Approved by UL60950 - 1 & CSA C22.2 No.60950-1, Built to meet DENAN
Built to meet VCCI - Class A & FCC class B
85
45 x 20.5 x 55
g
mm
Measurement point for
Vo, load / line reguration
(*1) At 100VAC and maximum output power, Ta = 25℃.
(*2) For cases where conformance to various safety specs (UL, CSA) are required, to be
described as 100 - 120VAC, 50/60Hz on name plate.
(*3) Please refer to Fig. A for measurement determination of line & load regulation and
output ripple & noise voltage.
(*4) From 85 - 132VAC, constant load.
-V
KS
(*5) From min load - full load (maximum power), constant input voltage.
(*6) From 0 to +50℃, constant input voltage and load.
C=0.1uF
Film Cap.
Measurement point for
output ripple & noise
(JEITA RC-9002A probe)
A
+V
(*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for
more than 30 seconds.
L=50mm
(*8) Over voltage clamping by zener diode.
Bandwidth of scope
100MHz
Fig.A
Output Derating
LOAD
(%)
100
80
60
40
25%
20
0
− 10 0
10 20 30 40 50 60 70
Ta
(℃)
・All specifications are subject to change without notice.
B-49
KS15
KS15
ITEMS/UNITS
Input
Output
KS
KWS
KWD
Function
Environment
Isolation
KS15 Specifications
MODEL
Voltage Range
(*2)
Frequency
(*2)
Efficiency (typ)
(*1)
Current (100VAC)(typ)
(*1)
Inrush Current (100VAC)(typ)
Nominal Voltage
Minimum Current
Maximum Current
Maximum Power
Voltage Setting Accuracy
Maximum Line Regulation (*3)(*4)
Maximum Load Regulation (*3)(*5)
Temperature Coefficient (*3)(*6)
Maximum Ripple & Noise (*3)
Hold-up Time (100VAC)(typ)
Over Current Protection (*7)
Over Voltage Protection (*8)
Parallel Operation
Series Operation
Operating Temperature (*9)
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
(*10)
Shock
Cooling
V
Hz
%
A
A
VDC
A
A
W
%
mV
mV
mV
mVp-p
ms
℃
℃
%RH
%RH
Withstand Voltage
Isolation Resistance
Safety Standards
Standards
EMI
Weight
Mechanical
Size (W x H x D)
KS15-5
KS15-12
AC85 - 132 or DC110 - 175
47 - 440
74
76
0.4
10 at Ta = 25℃, cold start
5
12
0
3.0
15.0
Fixed ± 5% (Max)
20
40
50
120
1.3
15.6
48
96
120
150
17 at 15W, Ta = 25℃
>105%
>110%
No
Yes
-10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%)
-30 to 85
30 - 90 (No dewdrop)
20 - 95 (No dewdrop)
10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each
Less than 490.3m/s2 for 11±5mS on ±(X, Y, Z) axis each 3 times
Convection cooling
Input - Output : 2kVAC (20mA), Input - FG : 2kVAC (20mA)
Output - FG : 500VAC (100mA) for 1minute each
More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC
Approved by UL60950 - 1 & CSA C22.2 No.60950-1, Built to meet DENAN
Built to meet VCCI-Class A & FCC class B
100
45 x 20.5 x 64
g
mm
Measurement point for
Vo, load / line reguration
(*1) At 100VAC and maximum output power, Ta = 25℃.
(*2) For cases where conformance to various safety specs (UL, CSA) are required to be
described as 100 - 120VAC, 50/60Hz on name plate.
(*3) Please refer to Fig. A for measurement determination of line & load regulation and
output ripple & noise voltage.
(*4) From 85 - 132VAC or 110 - 175VDC, constant load.
-V
KS
(*5) From min load - full load (maximum power), constant input voltage.
(*6) From 0 to +50℃, constant input voltage and load.
C=0.1uF
Film Cap.
Measurement point for
output ripple & noise
(JEITA RC-9002A probe)
A
+V
(*7) Current limiting with automatic recovery. Avioid to operate over load or dead short for
more than 30 seconds.
L=50mm
(*8) Over voltage clamping by zener diode.
Bandwidth of scope
100MHz
Fig.A
Output Derating
LOAD
(%)
100
80
60
40
25%
20
0
− 10 0
10 20 30 40 50 60 70
Ta
(℃)
B-50
・All specifications are subject to change without notice.
KS SERIES
Outline Drawing
【KS5】
*TERMINAL ASSIGNMENTS
①…FG
②…AC(N)
③…AC(L)
④…-V
NAME PLATE
⑤…+V
INPUT
OUTPUT
*MATERIAL
CASE:PLASTIC(UL94V-0)
KS
KWS
KWD
(unit:mm)
【KS10】
*TERMINAL ASSIGNMENTS
①…FG
②…AC(N)
③…AC(L)
NAME PLATE
④…-V
⑤…+V
INPUT
OUTPUT
*MATERIAL
CASE:PLASTIC(UL94V-0)
(unit:mm)
【KS15】
*TERMINAL ASSIGNMENTS
①…FG
②…AC(N)
③…AC(L)
NAME PLATE
④…-V
⑤…+V
INPUT
OUTPUT
*MATERIAL
CASE:PLASTIC(UL94V-0)
(unit:mm)
・All specifications are subject to change without notice.
B-51
KS 5
KWS
KWS5 Specifications
ITEMS/UNITS
Input
Output
KS
KWS
KWD
Function
Environment
Isolation
MODEL
Voltage Range
(*2)
Frequency
(*2)
Efficiency (typ)
(*1)
Current (100VAC)(typ)
(*1)
Inrush Current (100/200VAC)(typ)
Nominal Voltage
Minimum Current
Maximum Current
Maximum Power
Voltage Setting Accuracy
Maximum Line Regulation (*3)(*4)
Maximum Load Regulation (*3)(*5)
Temperature Coefficient (*3)(*6)
Maximum Ripple & Noise (*3)
Hold-up Time (100VAC)(typ)
Over Current Protection (*7)
Over Voltage Protection (*8)
Parallel Operation
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Cooling
Withstand Voltage
Isolation Resistance
Safety Standards
Standards
EMI
Weight
Mechanical
Size (W x H x D)
KWS5-5
KWS5-12
KWS5-15
V
Hz
%
A
A
VDC
A
A
W
%
mV
mV
mV
mVp-p
ms
AC85 - 265 or DC110 - 340
47 - 440
67
70
0.2
15 / 30
5
12
15
0
1.0
0.45
0.35
5.0
5.4
5.25
Fixed ±5% (Max)
20
48
60
40
96
120
50
120
150
120
150
17 at 5W, Ta=25℃
>105%
>110%
No
Possible
℃
-10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%)
℃
-30 to 85
%RH
30 - 90 (No dewdrop)
%RH
20 - 95 (No dewdrop)
10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each
Less than 490.3m/s2 for 11 ± 5ms on ± (X, Y, Z) axis each 3 times
Convection cooling
Input-Output : 3kVAC (20mA), Input-FG : 2kVAC (20mA)
Output-FG : 500VAC (100mA) for 1 minute each
More than 100MΩ at 25℃ and 70% RH Output-FG 500VDC
Approved by UL60950-1, CSA C22.2 No.60950-1 & EN60950
Built to meet VCCI-Class A & FCC class B & VDE class B
75
45 x 20.5 x 55
(*9)
g
mm
(*1) At 100VAC and maximum output power, Ta=25℃.
Measurement point for
Vo, load / line reguration
(*2) For cases where conformance to various safety specs (UL, CSA, TUV) are required,
to be described as 100 - 240VAC, 50/60Hz on name plate.
(*3) Please refer to Fig. A for measurement determination of line & load regulation and
output ripple & noise voltage.
(*4) From 85 - 265VAC, constant load.
-V
C=0.1uF
Film Cap.
KWS
(*5) From min load - full load (maximum power), constant input voltage.
Measurement point for
output ripple & noise
(JEITA RC-9002A probe)
A
(*6) From 0 to 50℃, constant input voltage and load.
(*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for
more than 30 seconds.
+V
(*8) Over voltage clamping by zener diode.
L=50mm
(*9) VDE class-B with external capacitor.
Bandwidth of scope
100MHz
Fig.A
Output Derating
LOAD
(%)
100
80
60
40
25%
20
0
− 10 0
10 20 30 40 50 60 70
Ta
(℃)
B-52
・All specifications are subject to change without notice.
KS 10
KWS
KWS10 Specifications
ITEMS/UNITS
Input
Output
Function
Environment
Isolation
MODEL
Voltage Range
(*2)
Frequency
(*2)
Efficiency (typ)
(*1)
Current (100VAC)(typ)
(*1)
Inrush Current (100/200VAC)(typ)
Nominal Voltage
Minimum Current
Maximum Current
Maximum Power
Voltage Setting Accuracy
Maximum Line Regulation (*3)(*4)
Maximum Load Regulation (*3)(*5)
Temperature Coefficient (*3)(*6)
Maximum Ripple & Noise (*3)
Hold-up Time (100VAC)(typ)
Over Current Protection (*7)
Over Voltage Protection (*8)
Parallel Operation
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Cooling
Withstand Voltage
Isolation Resistance
Safety Standards
Standards
EMI
Weight
Mechanical
Size (W x H x D)
KWS10-5
KWS10-12
KWS10-15
V
Hz
%
A
A
VDC
A
A
W
%
mV
mV
mV
mVp-p
ms
AC85 - 265 or DC110 - 340
47 - 440
73
75
0.3
15 / 30
5
12
15
0
2.0
0.9
0.7
10.0
10.8
10.5
Fixed ±5% (Max)
20
48
60
40
96
120
50
120
150
120
150
17 at 10W, Ta=25℃
>105%
>110%
No
Possible
℃
-10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%)
℃
-30 to 85
%RH
30 - 90 (No dewdrop)
%RH
20 - 95 (No dewdrop)
10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each
Less than 490.3m/s2 for 11±5ms on ± (X, Y, Z) axis each 3 times
Convection cooling
Input-Output : 3kVAC (20mA), Input-FG : 2kVAC (20mA)
KS
KWS
KWD
Output-FG : 500VAC (100mA) for 1 minute each
More than 100MΩ at 25℃ and 70% RH Output-FG 500VDC
Approved by UL60950-1, CSA C22.2 No.60950-1 & EN60950
Built to meet VCCI-Class A & FCC class B & VDE class B
100
45 x 20.5 x 64
(*9)
g
mm
Measurement point for
Vo, load / line reguration
(*1) At 100VAC and maximum output power, Ta=25℃.
(*2) For cases where conformance to various safety specs (UL, CSA, TUV) are required,
to be described as 100 - 240VAC, 50/60Hz on name plate.
(*3) Please refer to Fig. A for measurement determination of line & load regulation and
output ripple & noise voltage.
(*4) From 85 - 265VAC, constant load.
-V
KWS
(*5) From min load - full load (maximum power), constant Input voltage.
(*6) From 0 to +50℃, constant input voltage and load.
C=0.1uF
Film Cap.
A
+V
(*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for
more than 30 seconds.
L=50mm
(*8) Over voltage clamping by zener diode.
(*9) VDE class-B with external capacitor.
Measurement point for
output ripple & noise
(JEITA RC-9002A probe)
Bandwidth of scope
100MHz
Fig.A
Output Derating
LOAD
(%)
100
80
60
40
25%
20
0
− 10 0
10 20 30 40 50 60 70
Ta
(℃)
・All specifications are subject to change without notice.
B-53
KS 15
KWS
KWS15
ITEMS/UNITS
Input
Output
KS
KWS
KWD
Function
Environment
Isolation
KWS15 Specifications
MODEL
(*2)
Voltage Range
(*2)
Frequency
(*1)
Efficiency (typ)
(*1)
Current (100VAC)(typ)
Inrush Current (100/200VAC)(typ)
Nominal Voltage
Minimum Current
Maximum Current
Maximum Power
Voltage Setting Accuracy
Maximum Line Regulation(*3)(*4)
Maximum Load Regulation (*3)(*5)
Temperature Coefficient (*3)(*6)
Maximum Ripple & Noise (*3)
Hold-up Time (100VAC)(typ)
Over Current Protection (*7)
Over Voltage Protection (*8)
Parallel Operation
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Cooling
Withstand Voltage
Isolation Resistance
Safety Standards
Standards
EMI
Weight
Mechanical
Size (W x H x D)
KWS15-5
KWS15-12
KWS15-15
V
Hz
%
A
A
VDC
A
A
W
%
mV
mV
mV
mVp-p
ms
AC85 - 265 or DC110 - 340
47 - 440
74
77
0.4
20 / 40
5
12
15
0
3
1.3
1.0
15.0
15.6
15
Fixed ±5% (Max)
20
48
60
40
96
120
50
120
150
120
150
17 at 15W, Ta=25℃
>105%
>110%
No
Possible
℃
-10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%)
℃
-30 to 85
%RH
30 - 90 (No dewdrop)
%RH
20 - 95 (No dewdrop)
10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each
Less than 490.3m/s2 for 11±5ms on ± (X, Y, Z) axis each 3 times
Convection cooling
Input-Output : 3kVAC (20mA), Input-FG : 2kVAC (20mA)
Output-FG : 500VAC (100mA) 1 min
More than 100MΩ at 25℃ and 70% RH Output-FG 500VDC
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950
Built to meet VCCI-Class A & FCC class B & VDE class B
150
48 x 23.5 x 70
(*9)
g
mm
Measurement point for
Vo, load / line reguration
(*1) At 100VAC and maximum output power, Ta=25℃.
(*2) For cases where conformance to various safety specs (UL, CSA, TUV) are required,
to be described as 100 - 240VAC, 50/60Hz on name plate.
(*3) Please refer to Fig. A for measurement determination of line & load regulation and
output ripple & noise voltage.
-V
KWS
(*4) From 85 - 265VAC, constant load.
(*5) From min load - full load (maximum power), constant input voltage.
(*6) From 0 to 50℃, constant input voltage and load.
C=0.1uF
Film Cap.
A
+V
(*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for
more than 30 seconds.
(*8) Over voltage clamping by zener diode.
L=50mm
(*9) VDE class-B with external capacitor.
Measurement point for
output ripple & noise
(JEITA RC-9002A probe)
Bandwidth of scope
100MHz
Fig.A
Output Derating
LOAD
(%)
100
80
60
40
25%
20
0
− 10 0
10 20 30 40 50 60 70
Ta
(℃)
B-54
・All specifications are subject to change without notice.
KS SERIES
KWS
Outline Drawing
【KWS5】
*TERMINAL ASSIGNMENTS
①…FG
②…AC(N)
③…AC(L)
NAME PLATE
④…-V
⑤…+V
INPUT
OUTPUT
*MATERIAL
CASE:PLASTIC(UL94V-0)
KS
KWS
KWD
(unit:mm)
【KWS10】
*TERMINAL ASSIGNMENTS
①…FG
②…AC(N)
③…AC(L)
NAME PLATE
④…-V
⑤…+V
INPUT
OUTPUT
*MATERIAL
CASE:PLASTIC(UL94V-0)
(unit:mm)
【KWS15】
*TERMINAL ASSIGNMENTS
①…FG
②…AC(N)
③…AC(L)
NAME PLATE
④…-V
⑤…+V
INPUT
OUTPUT
*MATERIAL
CASE:PLASTIC(UL94V-0)
(unit:mm)
・All specifications are subject to change without notice.
B-55
KS 5
KWD
KWD5
KWD5 Specifications
MODEL
ITEMS/UNITS
Input
KS
KWS
KWD
Output
Function
Environment
Isolation
CH
Voltage Range
(*2)
Frequency
(*2)
Efficiency (typ)
(*1)
Current (100VAC)(typ)
(*1)
Inrush Current (100/200VAC)(typ)
Nominal Voltage
Minimum Current
Maximum Current
Maximum Power
Voltage Setting Accuracy
Maximum Line Regulation (*3)(*4)
Maximum Load Regulation (*3)(*5)
Temperature Coefficient (*3)(*6)
Maximum Ripple & Noise (*3)
Hold-up Time (100VAC)(typ)
Over Current Protection (*7)
Over Voltage Protection (*8)
Parallel Operation
Series Operation
Operating Temperature (*9)
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Cooling
V
Hz
%
A
A
VDC
A
A
W
%
mV
mV
mV
mVp-p
ms
℃
℃
%RH
%RH
Withstand Voltage
Isolation Resistance
Safety Standards
Standards
EMI
Weight
Mechanical
Size (W x H x D)
KWD5-1212
(*9)
g
mm
1
KWD5-1515
2
1
AC85 - 265 or DC110 - 340
47 - 440
69
2
69
0.2
15 / 30 at Ta = 25℃
-12
+15
0
0
0.22
0.18
+12
0
0.22
-15
0
0.18
5.3
5.4
Fixed ±5% (Max)
Fixed ±5% (Max)
60
60
75
75
600
600
750
750
120
120
150
150
150
150
150
150
17 at 5W, Ta = 25℃
>105%
>110%
-----------Possible
-10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%)
-30 to 85
30 - 90 (No dewdrop)
20 - 95 (No dewdrop)
10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each
Less than 490.3m/s2 for 11±5mS on ±(X, Y, Z) axis each 3 times
Convection cooling
Input - Output : 3kVAC (20mA), Input - FG : 2kVAC (20mA),
Output - FG : 500VAC (100mA) 1 min
More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC
Approved by UL60950 - 1, CSA C22.2 No.60950-1 & EN60950
Built to meet VCCI - Class B, FCC class B, VDE class B
75
45 x 20.5 x 55
Measurement point for
Vo, load / line reguration
(*1) At 100VAC and maximum output power, Ta = 25℃.
(*2) For cases where conformance to various safety specs (UL, CSA, TUV) are required,
to be described as 100 - 240VAC, 50/60Hz on name plate.
(*3) Please refer to Fig. A for measurement determination of line & load regulation and
output ripple & noise voltage.
-V
KWD
(*4) From 85 - 265VAC constant load.
(*5) From min load - full load (maximum power), constant input voltage.
(*6) From 0 to 50℃, constant input voltage and load.
COM
+V
(*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for
more than 30 seconds.
(*8) Over voltage clamping by zener diode (on CH2 only).
C=0.1uF
Film Cap.
C=0.1uF
Film Cap.
L=50mm
(*9) VDE class B with external capacitor.
Measurement point for
output ripple & noise
(JEITA RC-9002A probe)
A
A
Bandwidth of scope
100MHz
Fig.A
Output Derating
LOAD
(%)
100
80
60
40
25%
20
0
− 10 0
10 20 30 40 50 60 70
Ta
(℃)
B-56
・All specifications are subject to change without notice.
KS 10
KWD
KWD10 Specifications
MODEL
ITEMS/UNITS
Input
Output
Function
Environment
Isolation
Voltage Range
(*2)
Frequency
(*2)
Efficiency (typ)
(*1)
Current (100VAC)(typ)
(*1)
Inrush Current (100/200VAC)(typ)
Nominal Voltage
Minimum Current
Maximum Current
Maximum Power
Voltage Setting Accuracy
Maximum Line Regulation (*3)(*4)
Maximum Load Regulation (*3)(*5)
Temperature Coefficient (*3)(*6)
Maximum Ripple & Noise (*3)
Hold-up Time (100VAC)(typ)
Over Current Protection (*7)
Over Voltage Protection (*8)
Parallel Operation
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Cooling
CH
1
V
Hz
%
A
A
VDC
A
A
W
%
mV
mV
+12
0
mVp-p
ms
℃
℃
%RH
%RH
Withstand Voltage
Isolation Resistance
Safety Standards
Standards
EMI
Weight
Mechanical
Size (W x H x D)
KWD10-1212
(*9)
g
mm
KWD10-1515
2
1
AC85 - 265 or DC110 - 340
47 - 440
72
0.3
15 / 30 at Ta = 25℃
-12
+15
0
0
0.45
10.8
2
-15
0
0.36
10.8
Fixed ±5% (Max)
60
75
75
600
750
750
120
150
150
150
150
150
17 at 5W, Ta = 25℃
>105%
>110%
-----------Possible
-10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%)
-30 to 85
30 - 90 (No dewdrop)
20 - 95 (No dewdrop)
10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each
Less than 490.3m/s2 for 11±5mS on ±(X, Y, Z) axis each 3 times
Convection cooling
Input - Output : 3kVAC (20mA), Input - FG : 2kVAC (20mA),
Output - FG : 500VAC (100mA) for 1 minute each
More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC
Approved by UL60950 - 1, CSA C22.2 No.60950-1 & EN60950
Built to meet VCCI - Class B, FCC class B, VDE class B
100
45 x 20.5 x 64
60
600
120
150
Measurement point for
Vo, load / line reguration
(*1) At 100VAC and maximum output power, Ta = 25℃.
(*2) For cases where conformance to various safety specs (UL, CSA, TUV) are required,
to be described as 100 - 240VAC, 50/60Hz on name plate.
(*3) Please refer to Fig. A for measurement determination of line & load regulation and
output ripple & noise voltage.
-V
KWD
(*4) From 85 - 265VAC, constant load.
(*5) From min load - full load (maximum power), constant input voltage.
COM
(*6) From 0 to +50℃, constant input voltage and load.
+V
(*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for
more than 30 seconds.
(*8) Over voltage clamping by zener diode (on CH2 only).
C=0.1uF
Film Cap.
C=0.1uF
Film Cap.
L=50mm
(*9) VDE class B with external capacitor.
KS
KWS
KWD
Measurement point for
output ripple & noise
(JEITA RC-9002A probe)
A
A
Bandwidth of scope
100MHz
Fig.A
Output Derating
LOAD
(%)
100
80
60
40
25%
20
0
− 10 0
10 20 30 40 50 60 70
Ta
(℃)
・All specifications are subject to change without notice.
B-57
KS 15
KWD
KWD15 Specifications
MODEL
ITEMS/UNITS
Input
Output
KS
KWS
KWD
Function
Environment
Isolation
CH
Voltage Range
(*2)
Frequency
(*2)
Efficiency (typ)
(*1)
Current (100VAC)(typ)
(*1)
Inrush Current (100/200VAC)(typ)
Nominal Voltage
Minimum Current
Maximum Current
Maximum Power
Voltage Setting Accuracy
Maximum Line Regulation (*3)(*4)
Maximum Load Regulation (*3)(*5)
Temperature Coefficient (*3)(*6)
Maximum Ripple & Noise (*3)
Hold-up Time (100VAC)(typ)
Over Current Protection (*7)
Over Voltage Protection (*8)
Parallel Operation
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Cooling
V
Hz
%
A
A
VDC
A
A
W
%
mV
mV
mVp-p
ms
℃
℃
%RH
%RH
Withstand Voltage
Isolation Resistance
Safety Standards
Standards
EMI
Weight
Mechanical
Size (W x H x D)
KWD15-1212
1
KWD15-1515
2
1
AC85 - 265 or DC110 - 340
47 - 440
75
2
75
0.4
20 / 40 at Ta = 25℃
-12
+15
0
+12
0.65
15.6
-15
0.52
15.6
Fixed ±5% (Max)
60
75
75
600
750
750
120
150
150
150
150
150
17 at 5W, Ta = 25℃
>105%
>110%
-----------Possible
-10 to 70 (-10 : 80%, 0 to 50 : 100%, 70 : 25%)
-30 to 85
30 - 90 (No dewdrop)
20 - 95 (No dewdrop)
10 - 55Hz, constant amplitude 1.65mmp-p (Max 98.1m/s2), sweep 1 minute X, Y, Z 1 hour each
Less than 490.3m/s2 for 11±5mS on ±(X, Y, Z) axis each 3 times
Convection cooling
Input - Output : 3kVAC (20mA), Input - FG : 2kVAC (20mA),
60
600
120
150
Output - FG : 500VAC (100mA) for 1 minute each
More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC
Approved by UL60950 - 1, CSA C22.2 No.60950-1 & EN60950
Built to meet VCCI - Class B, ECC Class B, VDE class B
150
48 x 23.5 x 70 (Refer to outline drawing)
(*9)
g
mm
Measurement point for
Vo, load / line reguration
(*1) At 100VAC and maximum output power, Ta = 25℃.
(*2) For cases where conformance to various safety specs (UL, CSA, TUV) are required,
to be described as 100 - 240VAC, 50/60Hz on name plate.
(*3) Please refer to Fig. A for measurement determination of line & load regulation and
output ripple & noise voltage.
-V
KWD
(*4) From 85 - 265VAC constant load.
COM
(*5) From min load - full load (maximum power), constant input voltage.
(*6) From 0 to 50℃, constant input voltage and load.
+V
(*7) Current limiting with automatic recovery. Avoid to operate over load or dead short for
more than 30 seconds.
(*8) Over voltage clamping by zener diode (on CH2 only).
C=0.1uF
Film Cap.
C=0.1uF
Film Cap.
L=50mm
(*9) VDE class B with external capacitor.
Measurement point for
output ripple & noise
(JEITA RC-9002A probe)
A
A
Bandwidth of scope
100MHz
Fig.A
Output Derating
LOAD
(%)
100
80
60
40
25%
20
0
−10
0
10 20 30 40 50 60 70
Ta
(℃)
B-58
・All specifications are subject to change without notice.
KS SERIES
KWD
Outline Drawing
【KWD5】
*TERMINAL ASSIGNMRNTS
①…FG
②…AC(N)
③…AC(L)
INPUT
④…−V
⑤…COM
OUTPUT
⑥…+V
*MATERIAL
CASE:PLASTIC(UL94V-0)
KS
KWS
KWD
(unit:mm)
【KWD10】
*TERMINAL ASSIGNMRNTS
①…FG
②…AC(N)
③…AC(L)
INPUT
④…−V
⑤…COM
OUTPUT
⑥…+V
*MATERIAL
CASE:PLASTIC(UL94V-0)
(unit:mm)
【KWD15】
*TERMINAL ASSIGNMRNTS
①…FG
②…AC(N)
③…AC(L)
INPUT
④…−V
⑤…COM
OUTPUT
⑥…+V
*MATERIAL
CASE:PLASTIC(UL94V-0)
(unit:mm)
・All specifications are subject to change without notice.
B-59
KS
KS/KWS/KWD
SERIES
Block Diagram
N
A
−
●Topology‥Single-ended forward Type(ON/OFF)
A
Control
KS
KWS
KWD
Output
OCP
Oscillator
FG
+
OVP
85 - 132VAC
110 - 175VAC
Switching
Input
Rectifier & Filter
Fuse
Line Filter
L
Rectifier & Filter
■ KS SERIES
Voltage
Sensing
●Swtching Frequency‥KS5:330kHz(Fixed)
KS10、KS15:200kHz(Fixed)
●Fuse Rating‥4A
N
A
Output
−
OCP
A
Control
Oscillator
FG
+
OVP
85 - 265VAC
110 - 340VDC
Switching
Input
Rectifier & Filter
Fuse
Line Filter
L
Rectifier & Filter
■ KWS SERIES
Voltage
Sensing
●Topology‥Fly back Type(ON/OFF)
●Swtching Frequency‥KWS5、KWS10:220kHz(Fixed)
KWS15:200kHz(Fixed)
●Fuse Rating‥4A
■ KWD SERIES
Output
+V
Rectifier & Filter
N
Switching
85 - 265VAC
110 - 340VAC
Rectifier & Filter
Input
Line Filter
L
Fuse
COM
Rectifier & Filter
A
FG
−V
Control
Oscillator
OCP
Voltage
Sensing
A
●Topology‥Fly back Type(ON/OFF)
●Swtching Frequency:KWD5、KWD10…200kHz(Fixed)
KWD15…140kHz(Fixed)
●Fuse Rating…4A
B-60
・All specifications are subject to change without notice.
KS/KWS/KWD SERIES
KS/KWS/KWD Series Instruction Manual
BEFORE USING THE POWER SUPPLY UNIT
● Check that input/output terminals are correctly connected
according to instruction manual.
● KWS/KWD series are designed for 85-265VAC continuous
input. No need to switch operation to 100VAC or 200VAC
input voltage.
● KS series is designed for 85-132VAC input. If a 200VAC is
input, the power supply unit will be damaged.
1. Terminal Explanation
1 KS/KWS (single output)
KS
KWS
KWD
Nameplate
(upper side)
(3)
(5)
(2)
Bottom side
(1)
FG:
AC IN (N):
AC IN (L):
DC OUT (-V):
DC OUT (+V):
Frame ground terminal for grounding
AC input terminal (neutral line)
AC input terminal (live line) fuse in line
DC output terminal ("-" side)
DC output terminal ("+" side)
(1)
(2)
(3)
(4)
(5)
(6)
FG:
AC IN (N):
AC IN (L):
-V:
COM:
+V:
Frame ground terminal for grounding
AC input terminal (neutral line)
AC input terminal (live line) fuse in line
CH2 output terminal (-)
Ground terminal of CH1/CH2
CH1 output terminal (+)
(4)
2 KWD (dual outputs)
Nameplate
(upper side)
(3)
(1)
(2)
(3)
(4)
(5)
(6)
(2)
(5)
Bottom side
(4)
(1)
2. Terminal Connecting Method
1 KS/KWS (single output)
AC input
KS series: 85-132VAC
KWS series: 85-265VAC
(Continuous input type)
FG
−V
N
Input
ACIN
Nameplate
(upper side)
L
OUT
Load
+V
● A fuse in line of the power supply unit (L side of AC IN).
● KS series is designed for 85-132VAC input.
If a 200VAC is input, the unit may be damaged.
● KWS series is designed for 85-256VAC continuous input.
No need to switch.
2 KWD terminal (dual outputs)
AC input
85-265VAC
(Continuous input type)
● A fuse in line of the power supply unit (L side of AC IN).
● KWD series is designed for 85-256VAC continuous input and
the input switching operation is not necessary.
・All specifications are subject to change without notice.
FG
N
Input
−V
OUT
Nameplate
Load
COM
ACIN (upper side) OUT
+V
L
Load
B-61
KS/KWS/KWD SERIES
3. Explanation of Functions and Precautions
1 Over Current Protection (OCP)
6 Series/Parallel Operations
OCP type is current limiting with automatic recovery. OCP
For series operation, either (A) or (B) is possible. Please
function operates when the output current exceeds 105%
or above of OCP specifications. The output automatically recovers when the over current / shorted conditions
is removed. Do not operate under overload or dead short
conditions for more than 30 seconds, which could result
in damage to the unit.
connect a diode for by-pass when using method (A) of
the series operation. Please use the diode whose rated
forward current is equal or more than load current and the
rated maximum reverse voltage is higher than the output
voltage for each power supply.
3 Ripple
The maximum ripple voltage value in the specifications is
measured in the ripple measurement circuit designated by
JEITA RC-9131 probe. When the load wire is long, connect a film capacitor, etc., to prevent the ripple at the load
terminal from becoming large. Note that the accurate measurement is not possible if the probe ground lead of the
oscilloscope is long in measurement.
"Ripple measurement circuit"
+
−
+
−
+
−
ex: KWD5-1212
+V
AC
(L)
AC
(N)
+V
COM
AC
(N)
COM
−V
I1
I1
OUT
+12V
Load+12V
Load0
Load0
Load−12V
I(max)
0
:Maximum output current per channel
IN
IN
I
I
OUT
AC
(L)
+V
AC
(L)
+V
OUT
+24V
COM
COM
Load
−V
ex: KWD5-1212
−V
0
0
I≦I(max)
0
I≦I(max)
0
OUT
+V
OUT
+V
(N)
AC
COM
(N)
AC
COM
ex: KWD5-1212
+24V
Load
ex: KWD5-1212
ex: KWD5-1212
−
I2
−V
−12V
I2
I1, I2≦I(max)
0
II(max)
0
:
Maximum output current per channel
1, I2≦I(max)
0
ex: KWD5-1212
〔Two different outputs〕
IN
〔Two different outputs〕
(L)
IN AC
AC
(L)
Wire
Film capacitor
+
−
(B)
OUT
AC
(L)
(N)
AC
Measurement point
of maximum ripple voltage
+
(B)
(N)
AC
Measurement point
of output voltage
+
−
(A)
● KWD
series
〔+/−
Outputs〕
IN
〔+/− Outputs〕
IN
〔2 Serial outputs〕
−
+
−
− (A)
〔2 Serial outputs〕
+
−
−
LoadLoad
+
−
+
+
−
LoadLoad
Power supply
+
+
−
Output
Output
terminal
terminal
Power supply
Power supply
+
LoadLoad
KS
KWS
KWD
The over voltage protection (OVP) circuit with zener diode
clamp system is built in. (In KWD series, OVP circuit is
built into CH2 only.) Over 110% of nominal voltage will
clamp the output. If the output voltage is lowered due to
the over voltage application, the output will not resume.
Replacement of the power supply unit is necessary.
● KS, KWS series
Power supply
Output
Output
terminal
terminal
2 Over Voltage Protection (OVP)
I1
I1
I2
I2
I0
I0
−V
−V
Pararel operation is not possible.
+24V
+24V
+12V Load
+12V Load
Load
0
Load
0
I1、I2≦I(max)
0
I1、I2≦I(max)
0
Pararel operation is not possible.
4 EMI
7 Isolation Test
KWS and KWD series are built to meet the VDE Class B
standards by adding external capacitor between L and N
on the input side.
Refer to the recommended values below.
KWS5, KWD5: AC250V 0.22μF
The insulation resistance between output and FG is more
than 100MΩ at 500VDC. For safety operation, voltage
setting of DC isolation tester must be done before the test.
Ensure that it is fully discharged after the test.
Between output and FG
KWS10, KWD10: AC250V 0.22μF
KWS15, KWD15: AC250V 0.33μF
AC
(L)
AC
(N)
5 Inrush Current
KS10 and KS15 use power thermistor to protect the circuit
from inrush current. In power thermistor, the suppressed
current value changes depending on the temperature, and
the inrush current may become large in conditions with
high temperature or when restarting input soon after stopping it.
B-62
+V
COM
-V
FG
500VDC
8 Withstand Voltage
This series is designed to withstand 2kVAC for between
input and output, 2kVAC between input and FG, and
500VAC between output and FG each for 1 minute. When
testing withstand voltage, set current limit or withstand
voltage test equipment at 20mA. (Output-FG: 100mA)
・All specifications are subject to change without notice.
KS/KWS/KWD SERIES
The applied voltage must be gradually increased from zero
to testing value and then gradually decrease for shut down.
Input-FG (solid
(solid line)
line)
Input-FG
Input-Output (dotted
(dotted line)
line)
Input-Output
When timer is used, the power supply may be damaged by
AC
(L)
AC
(L)
high impulse voltage at timer switch on and off. If a timer
AC
(N)
AC
(N)
is used for measuring the test time, impulsive high voltage
may be generated in applying and cutting off the voltage,
causing damage to the unit.
* 3kVAC between input and output for KWS/KWD series
2 KVAC
KVAC 21 KVAC
22 KVAC
MIN
1 MIN
MIN
11 MIN
(20mA)
(20mA) (20mA)
(20mA)
KWD series
series
KWD
+V
+V
COM
COM
−V
−V
FG
FG
KWD series
series
KWD
Output-FG
Output-FG
AC
(L)
AC
(L)
AC
(N)
AC
(N)
500KVAC
500KVAC
MIN
11 MIN
(100mA)
(100mA)
+V
+V
COM
COM
−V
−V
FG
FG
KS
KWS
KWD
* For KS/KWS series, connect the +V and -V terminals of the output.
(KS/KWS series are not equipped with the COM terminal.)
There is no restriction on mountintg direction but there
should be enough consideration for airflow so that heat
does not accumulate around the power module vicinity.
Also note that the output derating is necessary when the
ambient temperature is high, as shown in the figure in the
right.
Output current (%)
4. Output Derating
100
80
60
40
25%
20
0
−10 0
10 20 30 40 50 60 70
Ambient temperature (°
C)
5. Recommended soldering/cleaning
1 Recommended soldering medhod
2 Recommended cleaning conditions
The temperature conditions in soldering should be the following.
Recommended cleaning conditions after soldering are
shown below.
● Dip condition: 260℃, within 10 seconds
Pre-heat conditions: 110℃ for 30-40 seconds
● Soldering iron: 350℃ within 3 seconds
● Cleaning solvent
IPA (isopropyl alcohol)
● Cleaning procedure
Cleaning should be conducted with a method that does
not cause intrusion of the cleaning fluid into the inside of
the power supply unit. (Note that if the cleaning fluid intrudes into inside of the power supply unit, the reliability of
the power supply may be impaired.)
Note) Consult us if your cleaning method is other than that
recommended above.
6. Before concluding power module damage
Check if the rated input voltage is connected.
Check if the wiring of input and output are correct.
Check if the pattern width connected to input/output is
not too narrow.
Ensure that a large capacitor is not connected on the
output side.
Please use within maximum capacitance shown below.
KS5:
5V 100μF or lower, 12V 200μF or lower
KS10: 5V 200μF or lower, 12V 400μF or lower
KS15: 5V 400μF or lower, 12V 1,000μF or lower
KWS5: 5V 2,000μF or lower, 12V/15V 200μF or lower
KWS10: 5V 2,000μF or lower, 12V/15V 1,000μF or
lower
KWS15: 5V 2,000μF or lower, 12V/15V 1,000μF or
lower
KWD5: 800μF or lower
KWD10: 1212 1,000μF or lower, 1515 500μF or lower
KWD15: 1212 1,000μF or lower, 1515 1,000μF or
lower
・All specifications are subject to change without notice.
B-63
B-64
ALL-1006E
web111014