Discontinue Issue Date
Last Purchase Order Date
Last Shipment Date
Aug. 5, 2019
Mar. 31, 2021
Sep. 30, 2021
E M C
• Please refer to our Web site about replacement information.
C o m p o n e n t s
3-terminal filters, SMD array
Differential signal line (cellular band compatible)
MEA-LD series
RoHS
REACH
SVHC-Free
Cl
Br
Pb
Halogen
Free
Lead
Free
pr
od
u
st cts
op w
pe il
d lb
pr e
od or
uc ha
tio ve
n
be
en
MEA2010LD type
FEATURES
LC filter with differential lines (D+ and D–) for high-density mounting.
Compact with a low profile design.
Can reduce radiation noise generated from differential signal lines (LVDS, MIPI, MDDI).
Effective as a desensitization countermeasure in information transmission terminals such as smart phones.
Operating temperature range: –40 to +85°C
APPLICATION
Noise removal for differential transmission lines (MIPI, etc.) of various mobile devices.
Application guides: Smart phones/tablets
PART NUMBER CONSTRUCTION
MEA
Series name
2010
LD
220
T
002
L×W×T dimensions
2.0×1.0×0.5 mm
Product internal
code
Capacitance
(pF)
Packaging style
Internal code
CHARACTERISTICS SPECIFICATION TABLE
Capacitance
(pF)
22
17
12
Cutoff frequency
Rated voltage
Rated current
Part No.
(MHz)typ.
240(Sdd)
330(Sdd)
430(Sdd)
(V)max.
6.3
6.3
6.3
(mA)max.
100
100
100
MEA2010LD220T002
MEA2010LD170T002
MEA2010LD120T002
Measurement equipment
Manufacturer
Keysight Technologies
Keysight Technologies
Th
e
Measurement item
Product No.
Capacitance
4294A
Frequency characteristics
N5230C
* Equivalent measurement equipment may be used.
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
(1/4)
20190807
3tf_commercial_signal_mea2010ld_en.fm
E M C
C o m p o n e n t s
MEA2010LD type
INSERTION LOSS VS. FREQUENCY CHARACTERISTICS
Insertion loss (dB)
10
20
30
pr
od
u
st cts
op w
pe il
d lb
pr e
od or
uc ha
tio ve
n
be
en
0
220 Scc
150 Sdd
40
220 Sdd
170 Scc
120 Scc
50
60
10
100
1000
100 Sdd
10000
Frequency (MHz)
Measurement equipment
Th
e
Product No.
Manufacturer
N5230C
Keysight Technologies
* Equivalent measurement equipment may be used.
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
(2/4)
20190807
3tf_commercial_signal_mea2010ld_en.fm
E M C
C o m p o n e n t s
MEA2010LD type
SHAPE & DIMENSIONS
0.10min.
CH4
GND
0.5±0.1
0.5±0.1
0.5±0.1
0.5±0.1
E
2.0±0.5
ø60min.
GND
CH3
1.0±0.15
0.15min.
1.0
Dimensions in mm
8.4 +2.0
–0.0
ø13±0.2
ø21±0.8
RECOMMENDED LAND PATTERN
Dimensions in mm
0.25
2.80
1.60
1.80
0.60
TAPE DIMENSIONS
Sprocket
hole
0.50
14.4max.
ø180±2.0
1.5 +0.1
–0
2.0±0.05
4.0±0.1
3.5±0.05
0.25±0.1
1.75±0.1
0.25
B
8.0±0.3
0.25±0.1
CH2
REEL DIMENSIONS
pr
od
u
st cts
op w
pe il
d lb
pr e
od or
uc ha
tio ve
n
be
en
2.0±0.15
CH1
PACKAGING STYLE
Dimensions in mm
K
A
Cavity
4.0±0.1
CIRCUIT DIAGRAM
CH1
CH2 CH3
Dimensions in mm
CH4
Type
MEA2010LD
GND
A
1.15±0.05
B
2.15±0.05
K
1.0max.
GND
160min.
Taping
200min.
RECOMMENDED REFLOW PROFILE
Preheating
Soldering
Natural
cooling
Drawing direction
300min.
Peak
250 to 260°C
Th
e
Temperature
Dimensions in mm
230°C
230°C
PACKAGE QUANTITY
Package quantity
4,000 pcs/reel
180°C
10s max.
150°C
60 to 120s
30 to 60s
TEMPERATURE RANGE, INDIVIDUAL WEIGHT
Operating
Storage
temperature range
temperature range
–40 to +85 °C
–40 to +85 °C
The storage temperature range is for after the assembly.
Individual
weight
5 mg
Time
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
(3/4)
20190807
3tf_commercial_signal_mea2010ld_en.fm
E M C
C o m p o n e n t s
REMINDERS FOR USING THESE PRODUCTS
Before using these products, be sure to request the delivery specifications.
pr
od
u
st cts
op w
pe il
d lb
pr e
od or
uc ha
tio ve
n
be
en
SAFETY REMINDERS
Please pay sufficient attention to the warnings for safe designing when using this products.
REMINDERS
The storage period is less than 12 months. Be sure to follow the storage conditions (temperature: 5 to 40°C, humidity: 10 to 75% RH or
less).
If the storage period elapses, the soldering of the terminal electrodes may deteriorate.
Do not use or store in locations where there are conditions such as gas corrosion (salt, acid, alkali, etc.).
Before soldering, be sure to preheat components.
The preheating temperature should be set so that the temperature difference between the solder temperature and chip temperature
does not exceed 150°C.
Soldering corrections after mounting should be within the range of the conditions determined in the specifications.
If overheated, a short circuit, performance deterioration, or lifespan shortening may occur.
When embedding a printed circuit board where a chip is mounted to a set, be sure that residual stress is not given to the chip due to
the overall distortion of the printed circuit board and partial distortion such as at screw tightening portions.
Self heating (temperature increase) occurs when the power is turned ON, so the tolerance should be sufficient for the set thermal
design.
Carefully lay out the coil for the circuit board design of the non-magnetic shield type.
A malfunction may occur due to magnetic interference.
Use a wrist band to discharge static electricity in your body through the grounding wire.
Do not expose the products to magnets or magnetic fields.
Do not use for a purpose outside of the contents regulated in the delivery specifications.
The products listed on this catalog are intended for use in general electronic equipment (AV equipment, telecommunications equipment, home appliances, amusement equipment, computer equipment, personal equipment, office equipment, measurement equipment, industrial robots) under a normal operation and use condition.
The products are not designed or warranted to meet the requirements of the applications listed below, whose performance and/or quality require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious damage to society,
person or property.
If you intend to use the products in the applications listed below or if you have special requirements exceeding the range or conditions
set forth in the each catalog, please contact us.
Th
e
(1) Aerospace/aviation equipment
(2) Transportation equipment (cars, electric trains, ships, etc.)
(3) Medical equipment
(4) Power-generation control equipment
(5) Atomic energy-related equipment
(6) Seabed equipment
(7) Transportation control equipment
(8) Public information-processing equipment
(9) Military equipment
(10) Electric heating apparatus, burning equipment
(11) Disaster prevention/crime prevention equipment
(12) Safety equipment
(13) Other applications that are not considered general-purpose
applications
When designing your equipment even for general-purpose applications, you are kindly requested to take into consideration securing protection circuit/device or providing backup circuits in your equipment.
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
(4/4)
20190807
3tf_commercial_signal_mea2010ld_en.fm
很抱歉,暂时无法提供与“MEA2010LD120T002”相匹配的价格&库存,您可以联系我们找货