• 90 - 150W Convection Cooled Ratings
• 1U High
• ATX SFX 12V Compatible
• Power Factor Corrected
• Peak Power Ratings
• No Minimum Loading Required
Key Market Segments & Applications
Industrial & Rack Mount
PC Applications
ZWX Series
180W to 300W
Industrial ATX Power Supplies
ZWX Features and Benefits
Features
Benefits
• Convection Cooled Ratings
• Low Profile
• Industrial Grade
• No minimum loading
• No Forced Air or Fan Needed
• Fits into 1U High Enclosures
• Greater Reliability & Field Life
• Easier to Use
Specifications
MODELS
ITEMS
Input Voltage
V
Input Current
(1)(2)
A
Inrush Current
(2)
A
Power Factor
Leakage Current
mA
Overcurrent Protection
(3)
Overvoltage Protection
(4)
V
Hold Up Time (Typ)
(1)
ms
Efficiency
(1)(2)
%
Remote On/Off
DC Good PWR_OK
Remote Sense
Output Voltage Setpoint Accuracy
Output Voltage Adjustment
Line Regulation
mV
Load Regulation
mV
Ripple & Noise
mV
Operating Temperature
°C
Storage Temperature
°C
Humidity (non condensing)
%RH
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock (non operating)
m/s2
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
g
Size (WxHxD)
mm
Warranty
yrs
ZWX180
ZWX240
ZWX300
85-265VAC (47-63Hz)
2.6 / 1.3
3.2 / 1.6
14 / 28 Cold start 25°C ambient
Meets EN61000-3-2
< 0.75
>1.05% of forced air current rating (5s delay and manual reset on V1, 2 & 3)
+3.3V: 3.76 - 4.3V, +5V: 5.74 - 7V, +12V: 13.4 - 15.6V
20ms at 100VAC
81 / 84
High: Unit off, Low: Unit On (enabled). Meets SFX12V
High: Power supply is good. Meets SFX12V
+3.3V Only
±5% (all outputs)
None
3.3V: 20mV, 5V: 48mV, +12V: 48mV, -12V: 20mV, +5Vsb: 20mV
3.3V: 100mV, 5V: 300mV, +12V: 300mV, -12V: 100mV, +5Vsb: 100mV
3.3V: 120mV, 5V: 150mV, +12V: 150mV, -12V: 120mV, +5Vsb: 120mV
-10 to +70, derate linearly to 20% load from 50 to 70
-30 to +85°C
Operating: 30 - 90, Non operating: 10 - 95
Convection or forced air cooled (30CFM, 0.85m3/min)
I/P to Gnd 2kVAC (20mA), I/P to O/P 3kVAC (20mA), O/P to Gnd 500VAC (100mA) for 1 min.
>100Ω at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
< 392
UL60950-1, CSA60950-1, EN60950-1, EN50178 (OV II), CE Mark
EN55011/EN55022-B, FCC Class B, VCCI-B
EN61000-4-2, -3, -4, -5, -6, -8, -11
500
650
800
94 X 36 X 210
106 X 36 X 225
118 X 36 X 250
3 Years
1.9 / 1.0
ZWX Series
1
Model Selector
Model
V1
V2
V3
V4
V5
V1
V2
V3
V4
V5
V1
V2
V3-1
V3-2
V4
V5
ZWX180
ZWX240
ZWX300
Output
Voltage
Max Curr.
(Convection)
+3.3V
+5V
+12V
-12V
+5V (sb)
+3.3V
+5V
+12V
-12V
+5V (sb)
+3.3V
+5V
+12V
+12V
-12V
+5V (sb)
6A(5)
5A(5)
6A
0.2A
1.4A
7A
6A
8A
0.2A
1.4A
10A
6A
4A(6)
8A(6)
0.2A
1.4A
Max Power
Max Curr
(Convection) (Forced Air)
8.4A(5)
7A(5)
9A
0.3A
2A
9.8A
8.4A
11.2A
0.3A
2A
14A
8.4A
5.6A
11.2A
0.4A
2A
90W
120W
150W
153W
204W
255W
Peak Curr. (4) Peak Power (4)
(Forced Air)
(Forced Air)
12A(5)
10A(5)
13A
0.3A
2A
14A
12A
16A
0.3A
2A
20A
12A
8A(7)
16A(7)
0.4A
2A
180W
240W
300W
NOTES: Specification Table Page 1
Options
Suffix
Description
Blank
/L1
/L2
/A1
/A2
Open frame
L Bracket - input on the left side (rear mounting side facing away)
L Bracket - input on the right side (rear mounting side facing away)
L Bracket & Cover - input on the left side (rear mounting side facing away)
L Bracket & Cover - input on the right side (rear mounting side facing away)
Connector
CN1
CN21
CN21(S-ATA)
CN31/CN41
CN51
(1) With output loading of:
ZWX180: V1=6.5A, V2=6.5A, V3=7.7A, V4=0.2A, V5=1A
ZWX240: V1=8.9A, V2=7.7A, V3=10.2A, V4=0.3A, V5=2A
ZWX300: V1=12A, V2=7A, V3-1=5A, V3-2=9.4A, V4=0.2A, V5=1A
(2) 100/200VAC
(3) Avoid prolonged operation in overload
(4)