0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DCS015

DCS015

  • 厂商:

    TELEDYNE

  • 封装:

    -

  • 描述:

    DESKEW CALIBRATION SOURCE FOR AP

  • 数据手册
  • 价格&库存
DCS015 数据手册
Current Probes Accurately Measure AC, DC and Impulse Currents Measure Currents in a Wide Range of Applications Measuring AC and DC Currents LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements. Fully Integrated with Oscilloscope Many current probes require external power supplies or amplifiers to display a waveform on the oscilloscope screen. All LeCroy current probes are powered through the LeCroy 2 ProBus® connection and require includes models with bandwidths no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This full integration also allows for Degauss and Autozero functions to be done directly from the oscilloscope with a single button press. up to 100 MHz, peak currents up to 700 A and sensitivities to 10 mA/div. Multiple current probes can be used together to make measurements on three-phase systems, or a single current probe can be used with a voltage probe to make accurate instantaneous power measurements. LeCroy current probes are often used Applications LeCroy current probes are available in a wide range of models for a wide range of applications. The full range of LeCroy current probes in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies. CP031 – 30A, 100 MHz Current Probe Features • 100 MHz bandwidth • Small form factor accommodates large conductors with small jaw size • 30 Arms continuous current, 50 A peak current The CP031 is LeCroy’s highest bandwidth current probe. Along with the high 100 MHz bandwidth the CP031can probe continuous currents of 30 A rms and peak currents up to 50 A. The CP031 features a small form factor making it easier to probe on a crowded, compact board. General Characteristics Electrical Characteristics* Cable Length 1.5 m Max. Continuous Input Current 30 A Bandwidth 100 MHz Weight 240 g Max. Peak Current at Pulse Width 50 A < 10 µs Max. Conductor Size (diameter) 5 mm Rise Time (typical) < 3.5 ns Interface ProBus, 1 MΩ only† Minimum Sensitivity 20 mA/div Usage Environment Indoors Low Frequency Accuracy 1% Operating Temperature 0 °C to 40 °C AC Noise < 2.5 mA Max. Relative Humidity 80% Coupling AC, DC, GND Max. Altitude 2000 m Maximum Insulated Wire Voltage 300 V CAT I * Guaranteed at 23 °C ±3 °C † Requires AP-1M for use with 50 Ω input only oscilloscopes. 10 35 30 25 Current (Arms) Insertion Impedance (Ω) 20 1 0.1 15 10 0.01 5 0 0.001 Frequency (Hz) Maximum Input Current vs. Frequency Frequency (Hz) Insertion Impedance vs. Frequency (typical) The CP031 is compatible with LeCroy X-Stream oscilloscopes running firmware version 4.3.1.1 or greater. 3 CP030 – 30 A, 50 MHz Current Probe Features • Small form factor accommodates large conductors with small jaw size • 30 Arms continuous current, 50 MHz bandwidth • 50 A peak current The CP030 was designed with a small form factor for today’s crowded boards. The small jaw can probe currents in tight spaces and still clamp onto conductors up to 5 mm in diameter. Continuous currents of 30 Arms and peak currents of 50 A can be measured by the CP030, which also features a 50 MHz bandwidth. General Characteristics Electrical Characteristics* Max. Continuous Input Current Bandwidth Max. Peak Current at Pulse Width Rise time (typical) Minimum Sensitivity Low Frequency Accuracy AC Noise Coupling 30 A 50 MHz 50 A < 10 µs < 7 ns 20 mA/div 1% < 2.5 mA AC, DC, GND * Guaranteed at 23 °C ±3 °C Cable Length Weight Max. Conductor Size (diameter) Interface Usage Environment Operating Temperature Max. Relative Humidity Max. Altitude Maximum Insulated Wire Voltage 1.5 m 240 g 5 mm ProBus, 1 MΩ only† Indoors 0 °C to 40 °C 80% 2000 m 300 V CAT I † Requires AP-1M for use with 50 Ω input only oscilloscopes. 10 35 30 Insertion Impedance (Ω) 25 Current (Arms) 20 15 10 0.1 0.01 5 0.001 0 Frequency (Hz) Maximum Input Current vs. Frequency 4 1 Frequency (Hz) Insertion Impedance vs. Frequency (typical) The CP030 is compatible with LeCroy X-Stream oscilloscopes running firmware version 4.3.1.1 or greater. AP015 – 30 A, 50 MHz Current Probe Features • 30 A rms continuous current, 50 MHz bandwidth • 50 A peak current for up to 10 seconds • Overheating and Probe Unlock Detection The AP015 current probe can measure continuous current of 30 A rms and peak pulses of up to 50 A for durations up to 10 seconds. This probe also features an overheating protection circuit, which will display an on-screen warning to the user to prevent damage. A probe unlock detection feature is also built in to the AP015 to ensure accurate measurements. General Characteristics Electrical Characteristics Max. Continuous Input Current Bandwidth Max. Peak Current at Pulse Width Rise time (typical) Minimum Sensitivity Low Frequency Accuracy Coupling 30 A 50 MHz 50 A < 10 s < 7 ns 10 mA/div 1% AC, DC, GND Cable Length Weight Max. Conductor Size (diameter) Interface Usage Environment Operating Temperature Max. Relative Humidity Max. Altitude Maximum Insulated Wire Voltage 2m 300 g 5 mm ProBus, 1 MΩ only† Indoors 0 °C to 40 °C 80% (Max. 31 °C) 2000 m 300 V CAT I, 150 V CAT II † Requires AP-1M for use with 50 Ω input only oscilloscopes. 10 1 Insertion Impedance ( ) 0.1 0.01 0.001 Frequency (Hz) Insertion Impedance vs. Frequency (typical) 5 CP150 – 150 A, 10 MHz Current Probe CP500 – 500 A, 2 MHz Current Probe CP150 Features 160 140 • 150 Arms continuous 120 current 100 • 500 A peak Current (A rms) 80 60 • 10 MHz bandwidth 40 20 0 Frequency (Hz) General Characteristics Electrical Characteristics Max. Continuous Input Current Bandwidth Max. Peak Current at Pulse Width Rise time (typical) Minimum Sensitivity Max. In-Phase Current Low Frequency Accuracy AC Noise Coupling 150 A 10 MHz 500 A < 30 µs < 35 ns 200 mA/div 500 A 1% 25 mA AC, DC, GND Cable Length Weight (probe only) Max. Conductor Size (diameter) Interface Usage Environment Operating Temperature Max. Relative Humidity Max. Altitude Maximum Insulated Wire Voltage Maximum Input Current vs. Frequency 2m 500 g 20 mm ProBus, 1 MΩ only† Indoors 0 °C to 40 °C 80% 2000 m 600 V CAT II, 300 V CAT III 1 0.01 0.001 Frequency (Hz) Insertion Impedance vs. Frequency (typical) † Requires AP-1M for use with 50 Ω input only oscilloscopes. 550 CP500 Features 500 450 400 • 500 Arms continuous current • 700 A peak • 2 MHz bandwidth 0.1 Insertion Impedance Current (A rms) 350 300 250 200 150 100 50 0 10 100 1k 10 k 100 k 1M 10 M Frequency (Hz) Maximum Input Current vs. Frequency General Characteristics Electrical Characteristics Cable Length 6m Weight (probe only) 630 g Max. Continuous Input Current 500 A Bandwidth 2 MHz Max. Conductor 20 mm Max. Peak Current at Pulse Width 700 A Size (diameter) Interface ProBus, 1 MΩ only† Rise time (typical) < 175 ns Usage Environment Indoors Minimum Sensitivity 200 mA/div Operating Temperature 0 °C to 40 °C Max. In-Phase Current 1150 A Max. Relative Humidity 80% Low Frequency Accuracy 1% Max. Altitude 2000 m AC Noise 25 mA Coupling AC, DC, GND Maximum Insulated Wire Voltage 600 V CAT II, 300 V CAT III † Requires AP-1M for use with 50 Ω input only oscilloscopes. 6 0.100 Insertion Impedance 0.010 0.001 Frequency (Hz) Insertion Impedance vs. Frequency (typical) Related Products and Ordering Information Related Products DA1855A – Differential Amplifier The DA1855A high-performance differential amplifier provides 100 MHz bandwidth, industry leading overdrive recovery, and outstanding common mode rejection ratio. The fast overdrive recovery provides the ability to make critical saturation voltage measurements while the high CMRR enables upper gate drive measurements. Built into the DA1855A is a precision voltage generator for offset far greater than the oscilloscope can provide on its own. The DA1855A can be operated in true differential mode or switched to comparator mode. DCS015 – Deskew Calibration Source To make accurate instantaneous power measurements it is critical that both the current and voltage waveforms be aligned in time. The DCS015 calibration source has both voltage and current time-aligned signals, which enables the precise deskew of voltage and current probes. Most voltage probes along with the AP015, CP015, CP030, and CP031 are compatible with the DCS015. ADP300 and ADP305 – Active Differential Probes The ADP300 and ADP305 are high-voltage differential probes ideal for measuring power electronics. The 20 MHz bandwidth ADP300 is good for troubleshooting low frequency power devices and other circuits where the reference potential is elevated from the ground or the ground is unknown. The 100 MHz bandwidth ADP305 is designed for measuring the floating voltages found in today’s high-speed power electronics. PMA2 – Power Measurement Analysis Software The PMA2 software option is used to make critical power switching device measurements, perform control loop modulation analysis, and measure power harmonics. With PMA2, the display and setup of voltage waveforms, current waveforms, and necessary measurement parameters are done automatically. Important device measurements like power losses, saturation voltage dynamic-on resistance, and safe operating area are easily performed. Pre-compliance testing to EN 61000-3-2 with easy-to -read graphical and tabular pass/fail results is built in to PMA2. Ordering Information Description Product Code 30 A; 100 MHz Current Probe – AC/DC; 30 Arms; 50 A Peak Pulse 30 A; 50 MHz Current Probe – AC/DC; 30 Arms; 50 A Peak Pulse 30 A; 50 MHz Current Probe – AC/DC; 30 Arms; 50 A Peak Pulse 150 A; 10 MHz Current Probe – AC/DC; 150 Arms; 500 A Peak Pulse 500 A; 2 MHz Current Probe – AC/DC; 500 Arms; 700 A Peak Pulse CP031 CP030 AP015 CP150 CP500 Customer Service LeCroy oscilloscopes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our digital oscilloscopes are fully warranted for three years. This warranty includes: • No charge for return shipping • Long term 7-year support • Upgrade to latest software at no charge 1-800-5-LeCroy www.lecroy.com Local sales offices are located throughout the world. To find the most convenient one visit www.lecroy.com © 2005 by LeCroy Corporation. All rights reserved. Specifications subject to change without notice. Other product or brand names are trademarks or requested trademarks of their respective holders. DCCP 07/05
DCS015 价格&库存

很抱歉,暂时无法提供与“DCS015”相匹配的价格&库存,您可以联系我们找货

免费人工找货