0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LPA-BNC

LPA-BNC

  • 厂商:

    TELEDYNE

  • 封装:

    -

  • 描述:

    PROLINK-TO-BNC ADAPTER, 1 EACH

  • 数据手册
  • 价格&库存
LPA-BNC 数据手册
WaveMaster 8600A 8500A 8300A Oscilloscopes LEADING FEATURES • 6, 5 or 3 GHz bandwidth • 10 GS/s sample rate/channel • 20 GS/s dual channel mode • All-SiGe front end for high signal fidelity (up to 75 ps rise time) WaveMaster oscilloscopes are the only scopes that include an all SiGe front end, X-Stream technology; and also offer user customization. • 1 ps rms jitter noise floor Maximum Performance Maximum Benefits • 1 ppm internal sample clock The WaveMaster™ oscilloscope is designed to • X-Stream™ technology data transfer is 10 –100X faster than other scopes meet next-generation Research and Development needs. It is the only high bandwidth scope to include an all-SiGe front end for highest signal fidelity, to use unique X-Stream technology to provide fast display updates (up to 100X faster) of your analyses, and to provide the ability to customize the scope with your own measurements or functions. Imagine the power this provides to solve your unique problems and to speed product development. In addition, the WaveMaster contains a SiGe trigger circuit for maximum trigger sensitivity at high bandwidths and extremely low (< 2.5 ps) trigger jitter. A high stability (1 ppm) internal sample clock ensures the most precise timing measurements. Capture up to 1 Mpt with standard memory (4 ch mode), or upgrade to longer memory (up to 48 Mpts in 2 ch mode) to enable debug and design characterization of complex or rare occurrences in long duration signals. LeCroy’s extensive measurement and analysis tool sets combined with innovative and intuitive displays make WaveShape Analysis simple. The high fidelity all-SiGe front end is ideal for use with the fastest, highest bandwidth requirements. Users making timing measurements will appreciate the low trigger jitter and superior timebase stability. The high resolution (800x600 pixel) display and 20% larger viewing area allow for crisp, clear display of signals. Our unique “Histicons” (small images showing live statistical variations in measurements), enable you to find signal problems you weren’t even aware of. • Customizable – add your own measurements or functions (VBScript, MATLAB, Mathcad, or Excel) using the optional XMAP software package • < 2.5 ps rms trigger jitter • SiGe trigger circuit (5 GHz bandwidth) • 10.4" TFT SVGA color display with 800 x 600 pixel resolution • 100BaseT Ethernet, standard • Intuitive graphical user interface makes advanced Waveshape Analysis simple • Win2000 O/S Easy to Use The familiar scope controls on the front panel,coupled with a powerful,efficient,easy-to-use graphical user interface,let you simply and quickly control the scope from the touch screen,front panel,mouse,or any combination of the above. The WaveMaster scope is able to quickly display long,complex signals,processed functions in various domains (time, frequency,and statistical),and measurements (choose from an extensive library). WaveMaster 8600A/8500A/8300A Oscilloscopes Unprecedented True Customization The precision and fidelity of the WaveMaster front end is unprecedented in a real-time oscilloscope. LeCroy has delivered the first product to truly meet the needs of high-speed digital designers with a combination of exceptional front end, trigger, and timebase performance together with long memory, X-Stream technology, and the first true ability to customize your scope to your exact needs. Only WaveMaster provides the ability to create your own parameter measurements or math functions in the scope’s user interface. Unique or proprietary MATLAB, Mathcad,VBScript, or even Excel calculations can be simply selected like any other LeCroy-installed parameter or math function, and the results displayed on the scope screen. It’s that easy! Since the resulting waveform is inserted back into the X-Stream processing flow, cursors, measurements, and math can be performed on it, giving much more power and flexibility than a simple export of data to a third party program. LeCroy’s advanced features also provide the ability to program the scope using ActiveX Automation language, embedded scripts, and other open Windows features, to create a scope that meets your specific needs. Why accept only connectivity when you can have true customization? Measurement Accuracy – Stable and Precise The WaveMaster oscilloscope delivers superior timebase performance and the lowest jitter noise floor of any DSO. The most advanced jitter characterization and analysis is possible with the WaveMaster scope’s 1 ps rms jitter noise floor and exceptional timebase stability (+/-1 ppm clock accuracy) for short and long record lengths. In addition,very low trigger jitter (< 2.5 ps) contributes to the ease and accuracy of acquiring high-speed signals. A front end which supports a rise time as fast as 75 ps, enables measurement of the fastest signal edges,with high signal fidelity. Exceptional Trigger Performance The WaveMaster SiGe trigger circuit delivers the fastest trigger capability on the market with a 5 GHz edge trigger bandwidth for capturing fast signals, and superior trigger sensitivity at high bandwidths.The versatile SMART Trigger® captures a variety of signals, including glitches and pulse widths down to 600 ps.The logic trigger makes it easy to trigger on a pattern of up to 5 inputs, or to qualify on 4 signal inputs and trigger on the 5th. A user-created MATLAB low-pass filter is easily inserted as function F1 in the WaveMaster user interface. Cursors LeCroy has responded to demand from oscilloscope users for dedicated cursor knobs and a very flexible selection of cursors. Different cursor modes are easily recalled and set. You can access them from the front panel or the graphical user interface. User Interface A 2 GHz sine wave input with persistence “on” demonstrates the exceptionally low trigger jitter on WaveMaster scopes. X-Stream Technology X-Stream should be a standard feature in every DSO, but it is only available in WaveMaster. X-Stream makes processing of waveform records up to 100X faster than other scopes. Imagine having the ability to see deep memory calculations updated quickly on the screen, and getting fast insight into the source of problems. Innovative views like “Histicons”help you identify signal problems without slowing down your display update. Why would you accept anything less? Leave outdated “viewing”technologies behind and upgrade to X-Stream. The familiar scope controls on the front panel, coupled with a natural, contextsensitive graphical user interface, react quickly to your commands. Functionality is exactly where you expect it to be. If you have questions, the context-sensitive on-line help gives immediate assistance. WaveMaster 8600A/8500A/8300A Oscilloscopes Specifications Vertical System Analog Bandwidth @ 50 Ω (-3 dB) Rise Time (Typical) Input Channels Bandwidth Limiters Input Impedance Input Coupling Maximum Input Vertical Resolution Sensitivity Offset Range WaveMaster 8600A WaveMaster 8500A 6 GHz 5 GHz 75 ps 90 ps 4 4 25 MHz; 250 MHz; 1 GHz, 3 GHz, 4 GHz 25 MHz; 250 MHz; 1 GHz, 3 GHz, 4 GHz 50 Ω ±2% DC, GND ±4 Vpeak 8 bits; up to 11 bits with enhanced resolution (ERES) 2 mV – 1 V/div fully variable; Full bandwidth at ≥ 10 mV/div 2 mV – 194 mV/div: ±750 mV; 195 mV – 1 V/div: ±4 V WaveMaster 8300A 3 GHz 150 ps 4 25 MHz, 250 MHz, 1 GHz Horizontal System Timebases Math & Zoom Traces Clock Accuracy Time Interval Accuracy Sample Rate + Delay Time Accuracy Jitter Noise Floor External Clock Frequency Internal timebase common to 4 input channels; an external clock may be applied at the Auxiliary Input 4 independent zoom and 4 math/zoom traces standard; 8 math/zoom traces available with XMAP (Master Analysis Package) ≤ 1 ppm @ 0–40 degrees C ≤ 0.06/SR + (1 ppm + Reading) (RMS) +/- 1 ppm ≤ 10s interval 1 ps rms (typical) 2 GHz maximum / 50 Ω impedance / applied at the auxiliary input Acquisition System Single-Shot Sample Rate/Ch 2 Channel Max Maximum Acquisition Points/Ch Standard M – Memory Option L – Memory Option VL – Memory Option XL – Memory Option 10 GS/s 20 GS/s ( 2 Ch) / (4 Ch) 2M / 1M 8M / 4M 16M / 8M 32M / 16M 48M / 24M Acquisition Modes Random Interleaved Sampling (RIS) Single-Shot Sequence Intersegment Time 200 GS/s for repetitive signals: 20 ps/div – 1 µs/div For transient and repetitive signals: 20 ps/div – 1000 s/div 2 – 20,000 segments (number of segments depends upon memory options) Typically 6 µs Acquisition Processing Averaging Enhanced Resolution (ERES) Envelope (Extrema) Summed averaging to 1 million sweeps. Continuous averaging to 1 million sweeps From 8.5 to 11 bits vertical resolution Envelope, floor, roof for up to 1 million sweeps Triggering System Modes Sources Coupling mode Pre-trigger delay Post-trigger delay Hold-off by time or events Internal trigger range Max trigger frequency External trigger input range Normal, Auto, Single, and Stop Any input channel, External, EXT X10, EXT/10, or line; slope and level unique to each source (except line trigger) DC 0 – 100% of horizontal time scale 0 – 10,000 divisions Up to 20 s or from 1 to 99 999 999 events ±5 div from center Up to 5 GHz with Edge Trigger; 750 MHz with SMART Trigger AUX (±0.4 V); AUX X10 (±0.04 V); AUX/10 (±4 V) Automatic setup Auto Setup Vertical Find Scale Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals. Automatically sets the vertical sensitivity and offset for the selected channels to display a waveform with maximum dynamic range. Probes Probes Probe System: ProLink with Probus Scale Factors A variety of passive and active probes is optional Automatically detects and supports a variety of compatible probes; Supports ProLink SMA or BNC input adapters. Automatically or manually selected depending on probe used. 8600A bandwidth and rise time specification is for sample speed ≥ 20 GS/s WaveMaster 8600A/8500A/8300A Oscilloscopes Specifications (continued) Color Waveform Display Type Resolution Realtime Clock Number of Traces Grid Styles Waveform Styles Color 10.4" flat-panel TFT-LCD with high resolution touch screen SVGA; 800 x 600 pixels Dates, hours, minutes, seconds displayed with waveform, SMTP support to synchronize to precision internet clocks Display a maximum of 8 traces. Simultaneously display channel, zoom, memory, and math traces. Single, Dual, Quad, Octal, XY, Single + XY, Dual + XY, or Auto Sample dots joined or dots only Analog Persistence Display Analog & Color-Graded Persistence Persistence Selections Trace Selection Persistence Aging Time Sweeps Displayed Variable saturation levels; stores each trace’s persistence data in memory. Select analog, color, or 3D Activate Analog Persistence on all or any combination of traces. Select from 500 ms to infinity. All accumulated, or all accumulated with last trace, highlighted. Zoom Expansion Traces Display up to 4 Zoom and 4 Math/Zoom traces (8 Math/Zoom traces available with XMAP Master Analysis Package option). CPU Processor Processing Memory Intel Pentium III (or better) with MS Windows 2000 Platform Up to 512 MBytes Internal Waveform Memory M1, M2, M3, M4 Internal Waveform Memory (Store full-length waveforms with 16 bits/data point) Or store to any number of files limited only by data storage media. Setup Storage Front Panel and Instrument Status Save to the internal hard drive, floppy drive or to a USB connected peripheral device. Interface Remote Control GPIB Port (Optional) Ethernet Port Floppy Drive USB Ports External Monitor Port Standard Parallel Port Via Windows automation, or via LeCroy GPIB command set Supports IEEE – 488.2 10/100BaseT Ethernet interface Internal, DOS-format, 3.5" high-density 4 USB ports support Windows compatible devices. 15-pin D-Type SVGA-compatible 1 standard Auxiliary Output Signal Types Calibrator Signal Control Signals Select from calibrator or control signals output on front panel. 5 Hz – 5 MHz square wave or DC Level; 0.0 to +0.5 Volts into 50 Ω (0 - 1 V into 1 MΩ), or TTL Volts (selectable) Trigger enabled, trigger out, pass/fail status Auxiliary Input Signal Types Select from External Trigger or External Clock input on front panel. General Auto Calibration Power Requirements Environmental EMC and Safety Certifications Ensures specified DC and timing accuracy is maintained for 1 year minimum. 100–120 VAC at 50/60/400 Hz; 200–240 VAC at 50/60 Hz; Power consumption: 800 VA , 800 Watts max. 5 to 40 °C operating temperature, -20 to 60 °C storage temperature CE approved, UL and cUL listed; Conforms to EN61326-1; EN61010-1, UL3111, and CSA C22.2 No. 1010.1 Physical Dimensions Dimensions (HWD) Weight Shipping Weight 264 mm x 397 mm x 491 mm; 10.4" x 15.6" x 19.3" (height excludes feet) 18 kg; 39 lbs. 24 kg; 53 lbs. Warranty and Service 3-year warranty; calibration recommended annually Optional service programs include extended warranty, upgrades, and calibration services. Specifications are subject to change. WaveMaster 8600A/8500A/8300A Oscilloscopes Specifications (continued) Basic Triggers Edge/Slope/Line Triggers when signal meets slope and level condition. SMART Triggers State or Edge Qualified Dropout Pattern Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events. Triggers if signal drops out for longer than selected time between 2 ns and 20 s. Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input) Each source can be high, low, or don’t care. Triggers at start or end of the pattern. SMART Triggers with Exclusion Technology Glitch Signal or Pattern Width Signal or Pattern Interval Triggers on positive or negative glitches with widths selectable from 600 ps to 20 s or on intermittent faults. Triggers on positive or negative pulse widths selectable from 600 ps to 20 s or on intermittent faults. Triggers on intervals selectable between 2 ns and 20 s. Math Tools (Standard) Master Analysis Package (XMAP) Display up to four math function traces (F1 – F4).The easy-to-use graphical interface simplifies setup of up to two operations on each function trace. Function traces can be chained together to perform math-on-math. invert (negate) absolute value log (base e) average (summed) log (base 10) average (continuous) product (x) derivative ratio (/) deskew (resample) reciprocal difference (–) rescale (with units) enhanced resolution (to 11 bits vertical) roof envelope (sin x)/x exp (base e) square exp (base 10) square root fft (power spectrum,magnitude phase up to 25 kpts) sum (+) floor trend (datalog) of 1,000 events histogram of 1,000 events zoom (identity) integral This package provides a comprehensive set of signal WaveShape Analysis Tools providing insight into the waveshape of complex signals. Additional capability provided by XMAP includes Automated Measure Tools (Standard) Displays any 8 parameters together with statistics, including their average, high, low, and standard deviations. Histicons provide a fast, dynamic view of parameters and wave shape characteristics. risetime (10-90%,20-80%,@ level) last amplitude rms level@x area std.deviation maximum base top mean cycles width median data time @ minimum (min.) minimum delay time @ maximum (max.) number of points ∆ delay ∆ time @ level +overshoot duty cycle ∆ time @ level from trigger –overshoot duration x @ max falltime (90-10%,80-20%,@ level) peak-to-peak x @ min period frequency phase first Pass/Fail Testing Simultaneously test multiple parameters against selectable parameter limits or pre-defined masks. Pass or fail conditions can initiate actions including document to local or networked files, email the image of the failure, save waveforms, send a pulse out of the front panel auxiliary BNC output, or (with the GPIB option) send a GPIB SRQ. • 8 math traces total (4 additional) • Parameter math – add,subtract,multiply,or divide two different parameters • Create your own measurement parameter or math function using third-party software packages and display the result in the scope. Supported third-party software packages include: VBScript(VisualBasic) Excel MATLAB Mathcad • Histograms expanded with 19 histogram parameters and up to 2 billion events • Trend (datalog) of up to 20,000 events • Track graphs of any measurement parameter • FFT capability added to include: power averaging, power density, real and imaginary components, frequency domain parameters, and FFT on up to 25 Mpts. • Narrow-band power measurements • Auto-correlation function • Persistence histogram, persistence trace (mean range, sigma) • All parameters in the JTA2 package Jitter and Timing Analysis Package (JTA2) This package provides jitter timing and analysis using time, frequency, and statistical views for common timing parameters, and also includes other useful tools. • Jitter and timing parameters, with “Track”graphs of Period Time Interval Error Cycle-Cycle Jitter Half Period Setup N-Cycle Hold N-Cycle w/ start selection Width Frequency Skew Duty Cycle Duty Cycle Error • Edge@lv parameter (counts edges) • Histograms expanded with 19 histogram parameters and up to 2 billion events • Trend (datalog) of up to 20,000 events • Track graphs of all parameters • Persistence histogram, persistence trace (mean, range, sigma) Sales and Service Throughout the World Ordering Information WaveMaster 8600A Four Channel Digital Oscilloscope 6 GHz, 20 GS/s 2 Ch (10 GS/s, 4 ch), 2 Mpts/2Ch; 1 Mpt/Ch Standard WaveMaster 8500A Four Channel Digital Oscilloscope 5 GHz, 20 GS/s 2 Ch (10 GS/s, 4 ch), 2 Mpts/2Ch; 1 Mpt/Ch Standard WaveMaster 8300A Four Channel Digital Oscilloscope 3 GHz, 20 GS/s 2 Ch (10 GS/s, 4 ch), 2 Mpts/2Ch; 1 Mpt/Ch Standard Product Code WAVEMASTER 8600A Product Code WAVEMASTER 8500A Product Code Corporate Headquarters 700 Chestnut Ridge Road Chestnut Ridge, NY 10977 USA http://www.lecroy.com WAVEMASTER 8300A LeCroy Sales Offices: Included with Standard 8600A and 8500A Configurations: Asia: Hong Kong Phone (852) 2834 5630 Fax (852) 2834 9893 ProLink Adapter SMA; 4 each ProLink Adapter BNC; 2 each Operator’s Manual; Quick Reference Guide; CD-ROM with OM/ RCM, Utility Software and Recovery Software Remote Control Manual Floppy Disk Drive CD ROM Drive Optical 3 button Wheel Mouse-USB Standard Ports; 10/100BaseT Ethernet, Parallel, SVGA Video Output, USB Protective Front Cover Standard Commercial Calibration and Performance Certificate 3 Year Warranty Austria: Markersdorf Phone (43) 2749 30050 Fax (43) 2749 30051 Benelux:The Netherlands Phone (31) 40 211 6998 Fax (31) 40 211 6999 France: Les Ulis Phone (33) 1 69 18 83 20 Fax (33) 1 69 07 40 42 Included with Standard 8300A Configuration: ProLink Adapter BNC; 5 each Operator’s Manual; Quick Reference Guide; CD-ROM with OM/ RCM, Utility software and Recovery Software Remote Control Manual Floppy Disk Drive CD ROM Drive Optical 3 button Wheel Mouse-USB Standard Ports; 10/100BaseT Ethernet, Parallel, SVGA Video Output, USB Protective Front Cover Standard Commercial Calibration and Performance Certificate 3 Year Warranty Germany: Heidelberg Phone (49) 6221 827 00 Fax (49) 6221 834 655 Memory Options Japan:Tokyo Phone (81) 3 3376 9400 Fax (81) 3 3376 9587 8 Mpts/2 Ch, 4 Mpts/ch 16 Mpts/2 Ch, 8 Mpts/ch 32 Mpts/2 Ch, 16 Mpts/ch 48 Mpts/2 Ch, 24 Mpts/ch Italy:Venice Phone (39) 041 456 97 00 Fax (39) 041 456 95 42 Japan: Osaka Phone (81) 6 6396 0961 Fax (81) 6 6396 0962 -M -L -VL -XL Software Options Master Analysis Package Jitter and Timing Analysis Disk Drive Measurement Package XMAP JTA2 DDM2 Selected Accessories ProLink Adapter BNC; 1 each ProLink Adapter BNC kit of 4 Keyboard 3.5 GHz Active Voltage Probe 7.5 GHz Low Capacitance Passive Probe 1.0 GHz Differential Probe 1 MΩ Adapter Norton Anti-Virus Oscilloscope Cart Oscilloscope Cart with additional shelf and drawer Rackmount Kit - 25”Slide Rackmount Kit - 30”Slide WaveMaster Soft Carrying Case WaveMaster Hard Shell Transit Case LPA-BNC LPA-BNC-Kit KYBD-1 HFP3500 PP066 AP034 AP-1M WM-AV OC1021 OC1024 RMA-25 RMA-30 WMSCC WMTC1 Korea: Seoul Phone (82) 2 3452 0400 Fax (82) 2 3452 0490 Spain: Madrid Phone: (34) 91 571 0024 Fax: (34) 91 571 2346 Switzerland: Geneva Phone (41) 22 719 2228 Fax (41) 22 719 2230 U.K.: Abingdon Phone (44) 1 235 536 973 Fax (44) 1 235 528 796 U.S.A.: Chestnut Ridge Phone (1) 845 578 6020 Fax (1) 845 578 5985 Warranty & Calibration A variety of extended warranty, certification, and calibration services are available. Contact LeCroy Sales and Service for details Copyright © 2002 by LeCroy Corp. LeCroy and ProBus are registered trademarks of LeCroy Corporation. WaveMaster and X-Stream are trademarks of LeCroy Corporation. All rights reserved. All other product names and brand names are trademarks of their respective companies. Information in this publication supersedes all earlier versions. Specifications subject to change without notice. DSWM MTECH 7.5K 07/02
LPA-BNC 价格&库存

很抱歉,暂时无法提供与“LPA-BNC”相匹配的价格&库存,您可以联系我们找货

免费人工找货