0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PK116

PK116

  • 厂商:

    TELEDYNE

  • 封装:

    -

  • 描述:

    PP006 SPARE ACCES KIT

  • 数据手册
  • 价格&库存
PK116 数据手册
Probe PP006A The PP006A is a high impedance passive probe with a wide range of probing accessories. It is designed to give high impedance probing capability to a circuit when attached to a LeCroy Oscilloscope. System BW (-3dB) System Attenuation System Input Resistance Compensation Range Cable Length Max. non-destructive input voltage Probe Sense : : : : : : : 500 MHz 10×±2% 10 M (Ω) // 12 pF 13 pF to 23 pF 1.2 meters, Connector type BNC 600 V (DC + Peak AC) (see derating curve) Yes 6 5 4 3 1 2 Accessories Table ① ② ③ ④ ⑤ ⑥ Item PP006A PK116 accessory package Sprung hook Ground lead (11 cm) Ground lead on probe tip IC Insulating tip Color marking band (yellow, red, blue, green) Trimmer tool 1 1 1 1 4×2 1 1 1 1 1 4×2 1 Probe Adjustment LF Adjustment LF compensation is made by connecting the probe to the cal signal and adjusting the compensation trimmer in the BNC-box at end of the probe. Connect the BNC end of the probe to a channel of the oscilloscope. Connect the sprung hook end (1) and the ground lead (2) to the CAL out and GND on the scope Calibrator area. The CAL signal is available in many speeds. Select the Utilities in the scope to set the CAL to 1 kHz. Turn the scope channel on. Press Auto Setup and adjust the time base and volts/div settings until the signal on the screen contains two cycles (see figures below). Use the Trimmer tool (6) to adjust the probe response to match the correct trim shown below. [Note] Do not apply excess pressure to the screwdriver when you use it. screwdriver are is easy to brake, because of made by plastics. Undershoot Correct Typical Voltage Derating Curve The tip of Overshoot Typical Input Impedance 1.0E +08 1000 1.0E +06 100 Zin[ohms] Voltage[V(DC+AC peak )] 1.0E +07 1.0E +05 1.0E +04 10 1.0E +03 1 0.1 1 10 100 Frequency[M H z] 1000 1.0E +02 1.0E +00 1.0E +02 1.0E +04 1.0E +06 Frequency[H z] 1.0E +08 1.0E +10 Installation for Safe and Efficient Operation Operating Environment Before using the Probe, ensure that its operating environment will be maintained within these parameters : Operation : In-door Use Temperature : 5 to 40 oC or 41 to 104 oF Humidity : < 80 % RH (non-condensing) The Probe has been designed to comply with EN61010-1 Installation (Overvoltage) Category II, 600 V, Pollution Degree 2. Safety Symbols Wherever the following safety symbols appear on the Probe or in the instruction manual, they alert the user to an aspect of safety. Symbol CAUTION WARNING Meaning Refer to accompanying documents (for Safety-related information). Risk of electric shock. Calls attention to a procedure, practice or condition that could possibly cause damage to equipment. Calls attention to a procedure, practice or condition that could possibly cause bodily injury or death. Usage The probe is intended to be used only with instruments which are connected to earth ground through the input BNC connector. Connect the grounding terminal of the probe to the ground potential of a device to be measured. WARNING Do not disconnect the probe while it is connected to a voltage source. Do not directly touch a measuring point. Do not use the probe in wet or explosive atmospheres. WARNING Probe tips are sharp, misuse can result in injury. Use with care. The use of the probe and/or the instrument it is connected to in a manner other than specified may impair the safety mechanisms. CAUTION To guarantee accurate performance characteristics, mechanical shocks should be avoided, as well as damage to the cable through excessive bending. Do not exceed the maximum specified signal voltage levels (See Specifications). Cleaning and Maintenance The exterior of the probe and cable should only be cleaned using a soft cloth moistened with water or isopropyl alcohol. The use of abrasive agents, strong detergents, or other solvents may damage the probe. Assure that the input receptacles are free of debris before inserting connection accessories. All repair and maintenance should be referred to qualified service personnel. Do not use the probe if any part is damaged. Sales & Service LeCroy Corporation Headquarters 700 Chestnut Ridge Road Chestnut Ridge, NY 10977-6499 Tel (800) 5 LECROY Fax (845) 578 5985 Copyright, January 1999. LeCroy is a registered trademark of LeCroy Corporation. All rights reserved. Information in this publication supercedes all earlier versions. Specifications subject to change without notice.
PK116 价格&库存

很抱歉,暂时无法提供与“PK116”相匹配的价格&库存,您可以联系我们找货

免费人工找货