T3DMM6-5

T3DMM6-5

  • 厂商:

    TELEDYNE

  • 封装:

  • 描述:

    手动 真有效值 RMS 工作台 数字(DMM) 万用表 6.5 位 TFT LCD 显示 电压,电流,电阻,电容,温度,频率 连续性,二极管测试 功能特性 Min/Max/Ave

  • 数据手册
  • 价格&库存
T3DMM6-5 数据手册
T3DMM6-5 /T3DMM6-5-SC Data Sheet 6.5 Digit Digital Multimeter with optional Scanner capability Broad Measurement Range DC: 1000 Volts AC: 750 Volts Current: 10A Tools for Improved Debugging ●● ●● ●● ●● ●● ●● Wide range of measurements – DC/AC voltage and Current, Resistance, Capacitance, Frequency, Period, Temperature, and more.  More application coverage from a single Digital multimeter. True-RMS measurements – All AC Voltage and Current ranges give True-RMS readings.  Excellent accuracy regardless of the waveform shape. Low level measurement, high sensitivity ranges – Voltage ranges as low as 200 mV full scale, DC Current 200 µA, AC Current 200 µA full scale.  High sensitivity ranges give greater accuracy of small signal measurements. Advanced measurement features – Min, Max, Average, Standard Deviation dBm/dB, Pass/fail, Histogram, Trend, Relative measurements.  Advanced features for today’s measurement needs. Built-in cold terminal thermocouple compensation – 4.3 inch (10.92 cm) color TFT-LCD 480 x 272 display.  Accurate Temperature measurements. USB Device, USB Host and LAN support  Remote control your measurements. Key Specifications DC Voltage 200 mV to 1000 V DC Current 200 µA to 10 A True RMS AC Voltage 200 mV to 750 V True RMS AC Current 200 µA to 10 A 2 /4 Wire Resistance 200 Ohms to 100 MOhms Connectivity USB Device, LAN Remote Control SCPI, LabView Driver PRODUCT OVERVIEW Teledyne Test Tools T3DMM6-5 is a 6½ digit digital multimeter incorporating the latest 4.3 inch (10.92cm) dualdisplay technology which can be configured to show data histograms, Data fluctuation Trends, Bar Graph, Statistics or the traditional Number mode, all in an easy to use interface. A great feature of the Teledyne Test Tools T3DMM6-5 is it’s ability to made highly accurate True RMS AC Voltage and Current measurements, meaning no loss of accuracy even when measuring complex voltage and current waveforms. The T3DMM6-5 is especially well suited for the needs of High precision multifunctional environments, as well as supporting a full range of automatic measurements. Main Functions Application fields Basic Measurement Function ●● Research Laboratory ●● DC Voltage: 200 mV ~ 1000 V ●● Development Laboratory ●● DC Current: 200 μA ~ 10 A ●● Repair and Maintenance ●● AC Voltage: True-RMS, 200 mV ~ 750 V ●● Calibration Laboratory ●● AC Current: True-RMS, 200 µA ~ 10 A ●● Automatic Production Test ●● 2/4-Wire Resistance: 200 Ω ~ 100 MΩ ●● General bench-top use ●● Capacitance: 2 nF ~ 100 mF ●● Continuity Test: Range is fixed at 2 kΩ ●● Diode Test: Adjustable range is 0 ~ 4 V. ●● Real 6½ digit (2,200,000 count) readings resolution ●● Frequency Measurement: 3 Hz ~ 1 MHz ●● Up to 10,000 rdgs/s measurement speed ●● Period Measurement: 1 μs ~ 333 ms ●● True-RMS AC Voltage and AC Current measuring ●● Temperature: Support for TC and RTD sensor ●● Max, Min, Average, Standard Deviation, dBm/dB, Relative Measurement, Pass/Fail Histogram, Trend Chart, Bar Graph ●● ●● Main Features ●● User-friendly Design ●● ●● 4.3” TFT-LCD, 480*272 ●● ●● Dual display, Chinese and English Menu ●● Built-in front panel accessible help system ●● File management (support for U-disc and local storage) 2 1 Gb flash memory for mass storage configuration files and data files Built-in cold terminal compensation for thermocouple T3DMM6-5-SC: Includes Scanner with 16 inputs (12 general purpose, 4 current channels) Standard interface: USB Device, USB Host, LAN USB & LAN remote interfaces support common SCPI command set. Compatible with other popular DMMs on the market. SPECIAL FEATURES Dual Display Bar Chart Statistics Histogram Trend Chart Hold Measurement dBm Hold Measurement Rear Panel Interfaces The Scanner Module is only included with the T3DMM6-5-SC DMM, it is not included with the T3DMM6-5 3 SPECIFICATIONS DC Characteristics Function DC Voltage DC Current Resistance 6) Diode Test 7) Continuity Test Range 2) 200.0000 mV 2.000000 V 20.00000 V 200.0000 V 1000.000 V4) 200.0000 μA 2.000000 mA 20.00000 mA 200.0000 mA 2.000000 A 10.00000 A5) 200.0000 Ω 2.000000 KΩ 20.00000 KΩ 200.0000 KΩ 1.000000 MΩ 10.00000 MΩ 100.0000 MΩ 0 ~ 2V 2 ~ 4V 2000.0 Ω Accuracy ± (% of reading + % of range) 1) Test Current Or Shunt Voltage < 0.03V < 0.25V < 0.07 V < 0.7V < 0.12 V < 0.6 V 1 mA 1 mA 100 μA 10 μA 2 μA 200 nA 200 nA || 10 MΩ 1 mA 1 mA 1 mA 24 Hour3) TCAL °C ± 1°C 90 day TCAL °C ± 5°C 1 Year TCAL °C ± 5°C 0.0020 + 0.0015 0.0015 + 0.0004 0.0020 + 0.0003 0.0020 + 0.0005 0.0020 + 0.0005 0.009 + 0.010 0.007 + 0.001 0.006 + 0.008 0.009 + 0.001 0.045 + 0.015 0.090 + 0.002 0.0030 + 0.0031 0.0020 + 0.0005 0.0020 + 0.0005 0.0020 + 0.0005 0.0020 + 0.0010 0.015 + 0.001 0.300 + 0.010 0.002 + 0.009 0.002 + 0.010 0.002 + 0.010 0.0030 + 0.0020 0.0020 + 0.0004 0.0030 + 0.0004 0.0040 + 0.0004 0.0040 + 0.0008 0.040 + 0.005 0.030 + 0.001 0.030 + 0.005 0.030 + 0.001 0.080 + 0.005 0.120 + 0.005 0.008 + 0.005 0.008 + 0.001 0.008 + 0.001 0.008 + 0.001 0.010 + 0.001 0.030 + 0.001 0.800 + 0.010 0.008 + 0.020 0.008 + 0.020 0.008 + 0.020 0.0040 + 0.0023 0.0035 + 0.0006 0.0040 + 0.0004 0.0050 + 0.0005 0.0055 + 0.0008 0.050 + 0.005 0.050 + 0.002 0.050 + 0.005 0.050 + 0.002 0.100 + 0.012 0.150 + 0.005 0.010 + 0.004 0.010 + 0.001 0.010 + 0.001 0.010 + 0.001 0.012 + 0.001 0.040 + 0.001 0.800 + 0.010 0.010 + 0.020 0.010 + 0.020 0.010 + 0.020 Temperature coefficient 0 °C to (TCAL °C - 5 °C) (TCAL °C + 5 °C) to 50 °C 0.0005 + 0.0003 0.0005 + 0.0001 0.0005 + 0.0001 0.0005 + 0.0001 0.0005 + 0.0001 0.0020 + 0.0026 0.0020 + 0.0001 0.0020 + 0.0015 0.0020 + 0.0001 0.0050 + 0.0008 0.0050 + 0.0018 0.0006 + 0.0006 0.0006 + 0.0001 0.0006 + 0.0001 0.0006 + 0.0001 0.0010 + 0.0002 0.0030 + 0.0005 0.1500 + 0.0002 0.0010 + 0.0020 0.0010 + 0.0020 0.0010 + 0.0020 Remarks: 1) Specifications are for 90-minute warm-up and 100 NPLC integration time. For integration time 7A DC or 7A AC RMS, use 30 seconds ON followed by 30 seconds OFF. 6) Specifications are for 4-wire resistance measurement or 2-wire resistance measurement using REL operation. Without REL operation, add 0.2 Ω additional error in 2-wire resistance measurement. 7) Accuracy specifications for the voltage measured at the input terminal only. 1 mA test current is typical. Variation in the current source will create some variation in the voltage drop across a diode junction. Adjustable voltage range: 0 ~ 4V. 4 SPECIFICATIONS Performance Versus Integration Time – 50 Hz (60 Hz) Power-line Frequency Integration Time Number of Power line Cycles5) (NPLC) 0.005(0.006) 0.05 (0.06) 0.5 (0.6) 1 10 100 Resolution1) NMRR2) Readings/s3) RMS Noise Adder 4) (% of Range) (ppm Range) (dB) 50 Hz 60 Hz DCV 20 V 2.7 1.6 1 0.22 0.08 0.035 10000 1000 100 50 5 0.5 10000 1000 100 60 6 0.6 0.0006 0.0004 0.0003 0 0 0 0 0 0 60 60 60 DCV 2 V 200 V Resistance 2 KΩ 20 KΩ 0.0008 0.0005 0.0003 0.0001 0 0 DCV 1000 V DCI 2 mA 200 mA 0.0015 0.0008 0.0006 0.0002 0 0 DCV 200 mV Resistance 200 Ω DCI 10 A 0.0040 0.0025 0.0025 0.0005 0.0002 0 Remarks: 1) Typical value. Resolution is defined as the typical 20V range RMS noise. 2) Normal mode rejection ratio for power-line frequency ± 0.1%. For power-line frequency ± 1%, subtract 20 dB. For ± 3 %, subtract 30 dB. 3) Maximum rate for DCV, DCI, 2-wire resistance and 4-wire resistance functions. 4) The basic DC accuracy specifications include RMS noise at 100 NPLC. For 3Hz ac filter and sine wave input. 2) 10 % over range on all ranges except ACV 750 V and ACI 10 A ranges. 3) Relative to calibration standards. 4) Specifications are for sine wave input > 5 % of range. For inputs within 1% and 5 % of range and 3 Hz > 20 Hz > 200 Hz 10 Hz – 20 Hz 0 0.74 – 20 Hz – 40 Hz 0 0.22 – 40 Hz – 100 Hz 0 0.06 0.73 100 Hz – 200 Hz 0 0.01 0.22 200 Hz – 1 kHz 0 0 0.18 > 1 kHz 0 0 0 Temperature coefficient 0 °C to (TCAL °C - 5 °C) (TCAL °C + 5 °C) to 50 °C 0.200 + 0.005 0.100 + 0.005 0.015 + 0.005 0.030 + 0.005 0.100 + 0.005 0.035 + 0.005 0.015 + 0.005 0.030 + 0.005 0.200 + 0.005 0.100 + 0.005 0.015 + 0.005 0.030 + 0.005 0.100 + 0.006 0.035 + 0.006 0.015 + 0.006 0.030 + 0.006 0.100 + 0.006 0.035 + 0.006 0.015 + 0.006 0.030 + 0.006 0.100 + 0.008 0.035 + 0.008 0.015 + 0.008 Additional Crest Factor Errors (non-sine wave)7) Crest Factor error (% of reading) 1 – 2 2 – 3 3 – 4 4 – 5 0.05 0.2 0.4 0.5 Remarks: 1) Specifications are for 90-minute warm-up, > 3 Hz ac filter and sine wave input. 2) 10 % over range on all ranges except ACV 750 V and ACI 10 A ranges. 3) Relative to calibration standards. 4)  Specifications are for sine wave input > 5 % of range. For inputs within 1% and 5 % of range and DC 7A or AC RMS 7A, use 30 seconds ON followed by 30 seconds OFF. 7) For frequency blow 100 Hz, the specification of the low frequency filters is for sine wave only. 8) Specifications are for sine wave input > 5 % of range. For inputs within 1% to 5 % of range, add 0.1% of range additional error. Specifications are typical values for 200 µA, 2 mA, 2 A and 10 A ranges when frequency > 1 kHz. 7 SPECIFICATIONS Frequency and Period Characteristics Function Frequency, Period Range 200 mV to 750 V Accuracy± (% of Reading) 1) 2) Frequency Range 24 Hour3) TCAL °C ± 1°C 90 day TCAL °C ± 5°C 1 Year TCAL °C ± 5°C 3 Hz – 5 Hz 5 Hz – 10 Hz 10 Hz – 40 Hz 40 Hz –300 KHz 300 KHz – 1 MHz 0.07 0.04 0.02 0.005 0.005 0.07 0.04 0.02 0.006 0.006 0.07 0.04 0.02 0.007 0.007 Frequency 3 Hz– 5Hz 5 Hz– 10 Hz 10 Hz–40 Hz 40 Hz–100 Hz 100 Hz–300 Hz 300Hz–1 KHz > 1 K Hz 1 s (0.1 ppm) 0 0 0 0 0 0 0 0.1 s (1 ppm) 0.12 0.17 0.20 0.06 0.03 0.01 0 Gate Time (Resolution) 0.01 s (10 ppm) 0.12 0.17 0.20 0.21 0.21 0.07 0.02 Temperature coefficient 0 °C to (TCAL °C - 5 °C) (TCAL °C + 5 °C) to 50 °C 0.005 0.005 0.001 0.001 0.001 0.001 s (100 ppm) 0.12 0.17 0.20 0.21 0.21 0.07 0.02 Remarks: 1) Specifications are for 90 minutes warm-up, using 1s gate time. 2) For frequency ≤ 300 kHz, the specification is the 10 % to 110 % of range of the AC input voltage. For frequency > 300 kHz, the specification is the 20 % to 110 % of range of the AC input voltage. The maximum input is limited to 750 V rms or 8 × 107 Volts-Hz (whichever is less). The 200 mV range is full range input or input that is larger than the full range. For 20 mV to 200 mV, multiply % of reading error × 10. 3) Relative to calibration standards. Capacitance Characteristic Accuracy± (% of Reading + % of Range) 1) Function Range 2) Test Current 1 Year TCAL °C ± 5°C Capacitance 2.0000 nF 20.000 nF 200.00 nF 2.0000 μF 20.000 μF 200.00 μF 2.0000 mF 20.000 mF 100.00 mF 10 μA 10 μA 100 μA 100 μA 1 mA 1 mA 1 mA 1 mA 1 mA 2 + 2.4 1 + 0.1 1 + 0.1 1 + 0.1 1 + 0.1 1 + 0.1 1 + 0.1 1 + 0.1 3 + 0.1 Remarks: 1) Specifications are for 90 minutes warm-up and using REL operation. Additional errors may be caused by non-film capacitors. 2) Specifications are the 1% to 110 % of range on 2 nF range and 10 % to 110 % of range on all other ranges. 8 Temperature coefficient 0 °C to (TCAL °C - 5 °C) (TCAL °C + 5 °C) to 50 °C 0.05 + 0.06 0.05 + 0.01 0.01 + 0.01 0.01 + 0.01 0.01 + 0.01 0.01 + 0.01 0.01 + 0.01 0.01 + 0.01 0.05 + 0.02 Temperature Characteristics Function Temperature Probe Type Accuracy± (% of Reading) 1) Type α = 0.00385 RTD 2) (R0 is 49 Ω to 2.1 kΩ) B E J K Thermocouple3) N R S T Optimum Range 1 Year TCAL °C ± 5°C -200 °C ~ 660 °C 0.16 °C Temperature coefficient 0 °C to (TCAL °C - 5 °C) (TCAL °C + 5 °C) to 50 °C 0.01°C 0 °C ~ 1820 °C -270 °C ~ 1000 °C -210 °C ~ 1200 °C -270 °C ~ 1370 °C -270 °C ~ 1300 °C -270 °C ~ 1760 °C -270 °C ~ 1760 °C -270 °C ~ 400 °C 0.76 °C 0.5 °C 0.5 °C 0.5 °C 0.5 °C 0.5 °C 0.6 °C 0.5 °C 0.14 °C 0.02 °C 0.02 °C 0.03 °C 0.04 °C 0.09 °C 0.11 °C 0.03 °C Remarks: 1) Specifications are for 90 minutes warm-up. Exclusive of sensor error. 2) Specification is for 4WR sensor measurement or 2WR measurement using REL operation. 3) Relative to cold junction temperature, accuracy is based on ITS-90. Built-in cold junction temperature refers to the temperature inside the banana jack and its accuracy is ± 2.5 . Measurement Rate Function DC Voltage DC Current 2-wire Resistance 4-wire Resistance AC Voltage AC Current Frequency and Period1) Capacitance2) Measurement rate 3) Setting 0.005 (0.006) NPLC 0.05 (0.06) NPLC 0.5 (0.5) NPLC 1 NPLC 10 NPLC 100 NPLC 3 Hz AC Filter 20 Hz 200 Hz 1 s Gate time 0.1 s 0.01 s 0.001 s 100 mF Range Integration 100 (100) µs 1 (1) ms 4 (4) ms 20 (16.7) ms 200 (167) ms 2 (1.67) s Readings/s 50 Hz (60 Hz) 10000 (10000) 1000 (1000) 100 (100) 50 (60) 5 (6) 0.5 (0.6) 0.5 2 50 1 10 100 500 0.5 Remarks: 1) 20 V range, 1 kHz input. 2) The measurement period changes with the capacitance under test. 3) Auto zero off, auto range off. 9 MEASURING METHOD AND OTHER CHARACTERISTICS DC Voltage Input Resistance 200 mV, 2 V, 20 V ranges: Selectable 10 MΩ or > 10 GΩ (For these ranges, input beyond ±26V are clamped through 106 kΩ (typical) 200 V and 1000 V ranges; 10 MΩ ± 1 % Input Offset Current 50 pA, 25 °C, typical Input Protection 1000 V CMRR (common mode rejection ratio) 140 dB for 1 kΩ unbalance in LO lead, ± 500 VDC peak maximum Resistance Measurement Method Open-circuit Voltage Max. Lead Resistance (4-wire) Offset Compensation Input Protection Selectable 4-wire or 2-wire resistance Current source referenced to LO input Limited to 300 Vrms (or > 5 Arms) will cause self-heating of signal-conditioning components and these error are included in the instrument specifications. Internal temperature changes due to self-heating may cause additional error on lower ac voltage ranges. The additional error will be lower than 0.02 % of reading and will generally dissipate within a few minutes as the signal-conditioning components return to normal operating temperature. Frequency and Period Measurement Method Input Impedance Input Protection Measurement Considerations Settling Time Considerations Reciprocal-counting technique, AC-coupled input using the AC voltage function. 1 MΩ ± 2% in parallel with < 150 pF capacitance on any range 750 V rms on all ranges All frequency counters are susceptible to error when measuring low-voltage, low-frequency signals. Shielding inputs from external noise is recommended. Errors will occur when attempting to measure the frequency or period of an input following a dc offset voltage change. Make sure the RC input circuit at the input terminals has fully settled (about 1 s) before making accurate measurements. Capacitance Measurement Measurement Method Connection Type Input Protection Measurement considerations Apply constant current into the capacitance, and measure the rate of voltage change. 2-wire 1000 V on all ranges Since small capacitance measurements are susceptible to the external noise, shielding inputs from external noise pickup is critical for minimizing measurement errors. Temperature Measurement Measurement Method Measurement considerations Support for TC and RTD types of sensor The built-in cold junction temperature tracks the temperature inside the banana jack. The change of the temperature in the banana jack may cause additional error. When using the built-in cold junction compensation, connect the sensor terminal of the thermocouple to the banana jack and allow it to warm up for at least 3 minutes to minimize errors. 11 MEASURING METHOD AND OTHER CHARACTERISTICS Triggering and Storage Trigger Time Base Resolution Trigger Delay Reading Sensitivity Single Trigger Samples External Trigger Input VMC Output Pre-trigger or Post-trigger, Internal Trigger or External Trigger, Rising Edge Trigger or Falling Edge Trigger 40 µs, 0.01 % Accuracy 0 to 1000s 0.01 %,0.1 %,1 %or10 %reading 1 to 599999999 Level: TTL compatible (High level when input terminal is disconnected) Trigger: Selectable rising edge or falling edge InputImpedance:≥30KΩ//500pF Delay: 100000 operations, at 1 A 30V DC (at 0.5 Hz) > 100000 operations, at 0.3 A 125 V AC (at 0.5 Hz) 75 mΩ (maximum at 6 VDC, 1 A) 5 ms maximum on/off (channel to channel ) Minimum 1 GΩ ( 500 VDC ) Clamp terminal, #24 AWG wire size Remarks: Please do not use the scanner capability to measure signals that exceed the specifications as this can damage or reduce the life of the scanner and cause electric shock or personal injury. Channel Capabilities Item No. of wires No. of channels DCV, ACV DCI, ACI 1) 2W Resistance 4W Resistance Capacitance Diode/Continuity Period/Frequency Temp (Thermocouple) Temp (RTD) 2 wires (H , L) 2 wires (H , L) 2 wires (H , L) 4 wires (Input H , L + sense H, L) 2 wires (H , L) 2 wires (H , L) 2 wires (H , L) 2 wires (H , L) 2 wires (H , L) 12 (CH1 ~ CH12) 4 (CH13 ~ CH16) (2A Range Only ) 12 (CH1 ~ CH12) 6 pairs (CH1 [input] & CH7[sense], 2&8, •••, 6&12) 12 (CH1 ~ CH12) 12 (CH1 ~ CH12) 12 (CH1 ~ CH12) 12 (CH1 ~ CH12) 12 (CH1 ~ CH12) Remarks: 1) For continuous current < 2.2 A, Accuracy ± (% 3 (reading) + 0.02 % (range)). 13 GENERAL SPECIFICATIONS Power Supply AC 100 V ~ 120 V 45 Hz – 66 Hz AC 200 V ~ 240 V 45 Hz – 66 Hz Detect the power-line frequency automatically at power-on, 400 Hz defaults to 50 Hz Power Consumption 25VA max Mechanical Dimension Weight (length × width × height): 345.45 mm × 260.29 mm × 107.21 mm 3.377 Kg (Net weight) Other characteristics Display Screen Working Environment EMC Safety Remote Interface Programming Language Warm Up Time 14 4.3 ”TFT-LCD with resolution 480*272 Full accuracy for 0°C to 50 °C Full accuracy to 40°C , 80 % R.H., Non-condensing Storage Temperature – 20 °C to 70 °C Shock and Vibration: conforming to MIL-T-28800E, III, 5 level (only for sine) Height above sea level: up to 3000 meters Conforming to EMC (2004/108/EC) and EN 61326-1:2013 IEC 61010-1; EN 61010-1; UL 61010-1; CAN/CSA-C22.2 No. 61010-1 Measurement CAT I 1000 V/CAT II 600 V 10/100Mbit LAN, USB2.0 Full Speed Device, Host Standard SCPI 90 minutes Ordering Information Product Name Models Standard Accessories Teledyne Test Tools T3DMM6-5 Digital Multimeter T3DMM6-5 6.5 Digit Digital Multimeter T3DMM6-5-SC 6.5 Digit Digital Multimeter including Scanner capability Power Cord that fits the destination country Two Test Leads, Two Alligator Clips USB Cable Quick Start Guide Warranty Card 15 ABOUT TELEDYNE TEST TOOLS Company Profile Teledyne LeCroy is a leading provider of oscilloscopes, protocol analyzers and related test and measurement solutions that enable companies across a wide range of industries to design and test electronic devices of all types. Since our founding in 1964, we have focused on creating products that improve productivity by helping engineers resolve design issues faster and more effectively. Oscilloscopes are tools used by designers and engineers to measure and analyze complex electronic signals in order to develop high-performance systems and to validate electronic designs in order to improve time to market. The Teledyne Test Tools brand extends the Teledyne LeCroy product portfolio with a comprehensive range of test equipment solutions. This new range of products delivers a broad range of quality test solutions that enable engineers to rapidly validate product and design and reduce time-tomarket. Designers, engineers and educators rely on Teledyne Test Tools solutions to meet their most challenging needs for testing, education and electronics validation. Location and Facilities Headquartered in Chestnut Ridge, New York, Teledyne Test Tools and Teledyne LeCroy has sales, service and development subsidiaries in the US and throughout Europe and Asia. Teledyne Test Tools and Teledyne LeCroy products are employed across a wide variety of industries, including semiconductor, computer, consumer electronics, education, military/aerospace, automotive/industrial, and telecommunications. Distributed by: Teledyne LeCroy (US Headquarters) 700 Chestnut Ridge Road Chestnut Ridge, NY. USA 10977-6499 Phone: Fax Sales: Phone Support: Email Sales: Email Support: Web Site: 800-553-2769 or 845-425-2000 845-578-5985 1-800-553-2769 contact.corp@teledynelecroy.com support@teledynelecroy.com http://teledynelecroy.com/ Teledyne LeCroy (European Headquarters) Teledyne LeCroy GmbH Im Breitspiel 11c D-69126 Heidelberg, Germany Phone: Fax: Phone Service: Phone Support: Email Sales: Email Service: Email Support: Web Site: +49 6221 82700 +49 6221 834655 +49 6221 8270 85 +49 6221 8270 28 contact.gmbh@teledynelecroy.com service.gmbh@teledynelecroy.com tlc.t3.appsupport.eu@teledyne.com http://teledynelecroy.com/germany teledynelecroy.com © 2018 Teledyne Test Tools is a brand and trademark of Teledyne LeCroy Inc. All rights reserved. Specifications, prices, availability and delivery subject to change without notice. Product brand or brand names are trademarks or requested trademarks of their respective holders. T3 stands for Teledyne Test Tools.
T3DMM6-5 价格&库存

很抱歉,暂时无法提供与“T3DMM6-5”相匹配的价格&库存,您可以联系我们找货

免费人工找货
T3DMM6-5
    •  国内价格
    • 1+13169.55179

    库存:1