T3DSO1000 Data Sheet
Oscilloscopes
Debug with Confidence
100 MHz – 200 MHz
Front panel of the four channel series
Front panel of the two channel series
Tools for Improved Debugging
●
●
●
●
●
●
Long Capture – 7 Mpts/Ch and 14 Mpts interleaved.
Capture more time and show more waveform detail.
Math and Measure – 7 basic math functions plus FFT
and 38 automatic measurement parameters.
Extract results from waveforms and measurements.
Connectivity – USB for mass storage, printing and
PC control, plus LAN for fast data transfer.
Save data for external analysis and screen images
for reports.
Serial Bus Trigger and Decode – I2C, SPI, UART,
RS232, CAN, LIN.
Debug serial buses directly in your Oscilloscope.
Waveform Sequence Recorder – record and play back
up to 80,000 waveforms.
Replay the changing waveform history.
Optional MSO – 16 Digital Channels
(4 channel series only).
Add mixed signal debugging to your Oscilloscope.
Key Specifications
Bandwidth
100 MHz, 200 MHz
Channels
2 or 4
Memory
up to 7 Mpts/Ch (14 Mpts interleaved)
Sample Rate
up to 500 MS/s / 1 GS/s interleaved
Display
7" Bright TFT LCD (800 x 480)
Connectivity
USB Host, USB Device, LAN
PRODUCT OVERVIEW
T3DSO1102: 2 Channel 100 MHz
T3DSO1104: 4 Channel 100 MHz
T3DSO1204: 4 Channel 200 MHz
Teledyne Test Tools new T3DSO1000 Oscilloscopes feature two channel and four channel models. The two channel
model is available with 100 MHz analog bandwidth, a single ADC with a 1 GSa/s maximum sample rate, and a single
memory module with 14 Mpts of sample memory. The four channel scope is available in 100 and 200 MHz models
and incorporates two 1 GSa/s ADCs and two 14 Mpts memory modules. When all channels are enabled, each channel
has sample rate of 500 MSa/s and a standard record length of 7 Mpts. When only a single channel per ADC is active,
the maximum sample rate is 1 GSa/s and the maximum record length is 14 Mpts.
For ease-of-use, the most commonly used functions can be accessed with its user-friendly front panel design.
The T3DSO1000 series employs a new generation of high
speed display technology that provides excellent signal
clarity, fidelity and performance. The system noise floor is
also lower than similar products in the industry. It comes
with a minimum vertical input range of 500 uV/div, an
innovative digital trigger system with high sensitivity and
low jitter, and a waveform capture rate of 400,000 frames/
sec (sequence mode). The T3DSO1000 also employs
a 256-level intensity grading display function and a color
temperature display mode not found in other models in
this class. Teledyne Test Tools latest oscilloscope offering
supports multiple powerful triggering modes including
serial bus triggering. Serial bus decoding for IIC, SPI, UART,
CAN, LIN bus types is included. The models also include
History waveform recording, and sequential triggering
that enable extended waveform recording and analysis.
Key Features
●
●
●
100 MHz, 200 MHz bandwidth models
Two channel series have one 1 GSa/s ADC, four
channel series have two 1 GSa/s ADCs. When all
channels are enabled, each channel has a maximum
sample rate of 500 MSa/s. When a single channel
per ADC is active, it has sample rate of 1 GSa/s
The newest generation of high speed display
technology
Waveform capture rate up to 100,000 wfm/s
(normal mode), and 400,000 wfm/s (sequence
mode)
Supports 256-level intensity grading and color
display modes Record length up to 14 Mpts
Digital trigger system
Another powerful addition is the new 1 million point
FFT math function that gives the T3DSO1000 very high
frequency resolution when observing signal spectra. The
new digital design also includes a hardware co-processor
that delivers measurements quickly and accurately
without slowing acquisition and front-panel response.
The features and performance of Teledyne Test Tools new
T3DSO1000 cannot be matched in this price class.
The four channel series includes even more functions,
including: searching and navigating, on-screen Bode plot,
16 digital channels (Option), an external USB powered
25 MHz AWG module (Option), a USB WIFI adapter
(Option), and an embedded application that allows remote
control via web browser.
●
●
●
●
●
›
›
›
2
●
Intelligent trigger: Edge, Slope, Pulse Width, Window,
Runt, Interval, Time out (Dropout), Pattern
Serial bus triggering and decoding (Standard), supports
protocols IIC, SPI, UART, RS232, CAN, LIN
Video trigger, supports HDTV
Low background noise with voltage scales from
500 μV/div to 10 V/div
10 types of one-button shortcuts, supports Auto Setup,
Default, Cursors, Measure, Roll, History, Display/Persist,
Clear Sweep, Zoom and Print Segmented acquisition
(Sequence) mode, divides the maximum record length
into multiple segments (up to 80,000), according to
trigger conditions set by the user, with a very small dead
time segment to capture the qualifying event.
History waveform record (History) function, maximum
recorded waveform length is 80,000 frames.
Models and key Specification
Model
T3DSO1102
T3DSO1104
T3DSO1204
Bandwidth
100 MHz
200 MHz
SamplingRate (Max.)
Two channel series have a single 1 GSa/s ADC, four channel series have two 1 GSa/s
ADCs. When all channels are enabled, each channel has a maximum sample rate of
500 MSa/s. When a single channel per pair is active, that channel has sample rate of
1 GSa/s
Channels
4 (four channel series)
2+EXT (two channel series)
Memory Depth (Max.)
7 Mpts/CH (not interleave mode);
14 Mpts/CH (interleave mode)
Waveform Capture Rate (Max.)
100,000 wfm/s (normal mode), 400,000 wfm/s (sequence mode)
Trigger Type
Edge, Slope, Pulse Width, Window, Runt, Interval, Dropout, Pattern, Video
Serial Trigger and decoder (Standard)
IIC, SPI, UART/RS232, CAN, LIN
16 Digital Channels
(four channel series only, option)
Maximum waveform capture rate up to 1 GSa/s, Record length up to 14 Mpts/CH
USB AWG module
(four channel series only, option)
One channel, 25 MHz, sample rate of 125 MHz, wave length of 16 kpts
Bode plot ( four channel series only)
Minimum start frequency of 10 Hz, minimum scan bandwidth of 500 Hz, maximum
scan bandwidth of 120 MHz (dependent on Oscilloscope and AWG bandwidth),
500 maximum scan frequency points
USB WIFI adapter
(four channel series only, option)
802.11b/g/b, WPA-PSK, the adapter must be purchased separately by the scope user
(TP-Link TL-WN725N)
I/O
USB Host, USB Device, LAN, Pass/Fail, Trigger Out, Sbus (Teledyne Test Tools MSO)
Probe (Std)
2/4 pcs passive probe T3PP300
Display
7 inch TFT-LCD (800 x 480)
Weight
Four channel series: Without package 2.6 Kg; With package 3.8 Kg
Two channel series: Without package 2.5 Kg; With package 3.5 Kg
●
●
●
●
●
Automatic measurement function for 38 parameters
as well as Measurement Statistics, Zoom, Gating,
Math, History and Reference functions
●
Bode plot (four channel series only)
●
Search and navigate (four channel series only)
●
USB AWG module (four channel series only, option)
●
USB WIFI adapter (four channel series only, option)
●
Web Browser based control (four channel series only)
Math functions (FFT, addition, subtraction,
multiplication,division, integration, differential, square
root)
●
Large 7 inch TFT-LCD display with 800 * 480 resolution
Preset key can be customized for user settings or
factory “defaults”
●
1 Mpts FFT
Math and measurement functions use all sampled
data points (up to 14 Mpts)
●
Security Erase mode
●
High Speed hardware based Pass/ Fail function
●
2/4 pcs passive probe T3PP300
●
●
Multiple interface types: USB Host, USB Device
(USB-TMC), LAN, Trigger Out
Supports SCPI remote control commands
Supports Multi-language display and embedded
online help
MSO, 16 digital channels (four channel series only,
option)
3
FUNCTION & CHARACTERISTICS
7 inch TFT-LCD display and
10 one-button menus
When all channels are enabled, each channel
has a maximum sample rate of 500 MSa/s.
When a single channel per pair is active,
that channel has sample rate of 1 GSa/s
Front panel of the four channel series
Front panel of the two channel series
●
●
●
7-inch TFT-LCD display with 800 * 480 resolution
Most commonly used functions are accessible using
10 different one-button operation keys: Auto Setup,
Default, Cursor, Measure, Roll, History, Persist, Clear
Sweep, Zoom, Print
Record Length of Up to 14 Mpts
(single channel/pair mode),
7 Mpts/CH (two channels/ pair mode)
Using hardware-based Zoom technologies and max record
length of up to 14 Mpts, users are able to over-sample to
capture longer time periods at higher resolution and use
the zoom feature to see more details within each signal.
4
The four channel series has two 1 GSa/s ADC chips
(channel 1 and 2 share one, channel 3 and 4 share
another), so that each channel can achieve sample rates
up to 500 MSa/and work on bandwidths of 200 MHz
when all channels are enabled.
Waveform Capture Rate
Up to 400,000 wfm/s
With a waveform capture rate of up to 400,000 wfm/s
(sequence mode), the oscilloscope can easily capture
the unusual or low-probability events.
256-Level Intensity Grading and
Color Temperature Display
History Waveforms (History) Mode and
Segmented Acquisition (Sequence)
New display technology provides for fast refresh rates.
The resulting intensity-graded trace is brighter for events
that occur with more frequency and dims when the
events occur with less frequency.
Playback the latest triggered events using the history
function. Segmented memory collection will store trigger
events into multiple (Up to 80,000) memory segments,
each segment will store triggered waveforms and
timestamp each frame.
True measurement to 14 M points
The color temperature display is similar to the intensitygraded trace function, but the trace occurrence is
represented by different colors (color “temperature”) as
opposed to changes in the intensity of one color. Red
colors represents the more frequent events, while blue is
used to mark points that occur lest frequently.
At any one timebase, T3DSO1000 can measure using
all 14 M sample points. This ensures the accuracy of
measurements while the math coprocessor decreases
measurement time and increases ease-of-use.
Serial Bus Decoding Function (Standard)
Gate and Zoom Measurement
T3DSO1000 displays the decoding through the
events list. Bus protocol information can be quickly
and intuitively displayed in a tabular format.
Through Gate and Zoom measurement, the user can
specify an arbitrary interval of waveform data analysis
and statistics. This helps avoid measurement errors
that can be caused by invalid or extraneous data, greatly
enhancing the measurements’ validity and flexibility.
5
FUNCTION & CHARACTERISTICS
1 M points FFT
16 Digital Channels/MSO
(four channel series only, option)
The new math co-processor enables FFT analysis of
incoming signals using up to 1 M samples per waveform.
This provides high frequency resolution with a fast refresh
rate. The FFT function also supports a variety of window
functions so that it can adapt to different spectrum
measurement needs.
16 digital channels enables users to acquire and trigger on
the waveforms then analyze the pattern, simultaneously
with one instrument. Color coded logic levels clearly
differentiate high and low states.
Hardware-Based High Speed
Pass/Fail function
Search and Navigate
(four channel series only)
The T3DSO1000 utilizes a hardware-based Pass/Fail
function, performing up to 40,000 Pass/Fail decisions
each second. Easily generate user defined test templates
provide trace mask comparison making it suitable for
long-term signal monitoring or automated production
line testing.
Customizable Default Key
The T3DSO1000 4 channel series can search events
specified by the user in a frame. It can also navigate by
time (delay position) and historical frames.
The current parameters of the oscilloscope can be
preset to Default Key through the Save menu.
6
Bode Plot (four channel series only)
USB 25 MHz AWG Module
(four channel series only, option)
The four channel series supports an optional USB 25 MHz
function/arbitrary waveform generator that is operated
from the USB host connection. Functions include
Sine, Square, Ramp, Pulse, Noise, DC and 45 built-in
waveforms. The arbitrary waveforms can be accessed
and edited by the Teledyne Test Tools PC software.
Complete Connectivity
T3DSO1000 can control the USB AWG module, control an
independent Teledyne Test Tools T3AFG instrument, scan
an object’s amplitude and phase frequency response,
and display the data as a Bode Plot. It can also show the
result lists, and export the data to a USB disk.
USB WiFi Adapter
(four channel series only, option)
Back panel of
the four channel
series
Back panel of
the two channel
series
T3DSO1000 supports USB Host, USB Device (USB-TMC),
LAN(VXI-11), Pass/Fail and Trigger Out.
Web control (four channel series only)
USB WiFi Adapter
WiFi control of instrumentation can provide a convenient
and safe method of configuring and collecting data.
This new feature works with a Teledyne Test Tools
approved WiFi adapter to provide wireless control and
communications with Teledyne Test Tools 4 channel
scopes. The approved adapter is the TP-Link TL-WN725N
(not supplied).
With the new embedded web server, users can control the
4 channel scopes from a simple web page. This provides
remote troubleshooting and monitoring capabilities.
7
SPECIFICATIONS
Acquire System
Sampling Rate
Memory Depth
Peak Detect
Average
Eres
Waveform interpolation
1 GSa/s (single channel/pair), 500 MSa/s (two channels/pair)
Max 14 Mpts/Ch (single channel/pair), 7 Mpts/Ch (two channels/pair)
2 nsec (Four channel series)
4 nsec (Two channel series)
Averages: 4, 16, 32, 64, 128, 256, 512, 1024
Enhance bits: 0.5, 1.5, 2, 2.5, 3; Selectable
Sin(x)/x, Linear
Input
Channels
Coupling
Impedance
Max.Input voltage
CH to CH Isolation
Probe attenuation
4 (Four channel series)
2+EXT (Two channel series)
DC, AC, GND
DC: (1 MΩ ± 2 %) || (15 pF ± 2 pF) (Four channel series)
DC: (1 MΩ ± 2 %) || (18 pF ± 2 pF) (Two channel series)
1 MΩ ≤ 400 Vpk (DC + Peak AC 40 dB
0.1X, 0.2X, 0.5X, 1X, 2X, 5X, 10X……1000X, 2000X, 5000X, 10000X
Vertical System
Bandwidth (–3 dB )
Vertical Resolution
Vertical Scale (Probe 1X)
Offset Range (Probe 1X)
Bandwidth Limit
Bandwidth Flatness
Low Frequency Response (AC – 3 dB)
Noise
SFDR including harmonics
DC Gain Accuracy
Offset Accuracy
Risetime
Overshoot (500 ps Pulse)
200 MHz (T3DSO1204)
100 MHz (T3DSO1102 / T3DSO1104)
8-bit
500 μV/div – 10 V/div (1-2-5 sequence )
500 μV – 150 mV: ± 2 V
152 mV – 1.5 V: ± 20 V
20 MHz ± 40%
DC – 10 % (BW): ± 1 dB
10 % – 50 % (BW): ± 2 dB
50 % – 100 % (BW): + 2 dB/-3 dB
≤ 10 Hz (at input BNC)
ST-DEV ≤ 0.5 division (< 1 mV/div)
ST-DEV ≤ 0.2 division (< 2 mV/div)
ST-DEV ≤ 0.1 division (≥ 2 mV/div)
≥ 35 dB
≤ ± 3.0%: 5 mV/div – 10 V/div
≤ ± 4.0%: ≤ 2 mV/div
± (1 % * Offset + 1.5 % * 8 * div + 2 mV): ≥ 2 mV/div
± (1 % * Offset + 1.5 % * 8 * div + 500 uV): ≤ 1 mv/div
Typical 1.8 ns (T3DSO1204)
Typical 3.5 ns (T3DSO1102 / T3DSO1104)
< 10 %
Horizontal System
Timebase Scale
Channel Skew
Waveform Capture Rate
Intensity grading
Display Format
Timebase Accuracy
Roll Mode
8
1.0 ns/div – 100 s/div
< 100 ps
Up to 100,000 wfm/s (normal mode), 400,000 wfm/s (sequence mode)
256 Levels
Y-T, X-Y, Roll
± 25 ppm
50 ms/div – 100 s/div (1-2-5 step)
Trigger System
Trigger Mode
Trigger Level
Holdoff Range
Trigger Coupling
Coupling Frequency Response
Coupling Frequency Response
components below 10 KHz
Trigger Sensitivity
Trigger Jitter
Trigger Displacement
Auto, Normal, Single
Internal: ± 4.5 div from the center of the screen
EXT: ± 0.6 V (Two channel series)
EXT/5: ± 3 V (Two channel series)
80 ns – 1.5 s
AC
DC
LFRJ
HFRJ
Noise RJ
DC: Passes all components of the signal
AC: Blocks DC components and attenuates signals below 8 Hz
LFRJ: Blocks the DC component and attenuates the low-frequency components below 2 MHz
HFRJ: Attenuates the high-frequency components above 1.2 MHz
DC: Passes all components of the signal
LFRJ: Blocks the DC component and attenuates the low-frequency components below 10 KHz
HFRJ: Attenuates the high-frequency components above 500 KHz
Internal: ± 0.2 div
EXT (Two channel series): ± 0.4 div
DC – Max BW 0.6 div
EXT (Two channel series): 200 mVpp DC – 10 MHz
300 mVpp 10 MHz – BW frequency
EXT/5 (Two channel series): 1 Vpp DC – 10 MHz
1.5 Vpp 10 MHz – BW frequency
< 100 ps
Pre-Trigger: 0 – 100 % Memory
Delay Trigger: 0 to 10,000 div
Edge Trigger
Slope
Source
Rising, Falling, Rising & Falling
All channels/ EXT/ (EXT/5)/ AC Line (Two channel series)
All channels/ AC Line (Four channel series)
Slope Trigger
Slope
LimitRange
Source
TimeRange
Resolution
Rising, Falling
,,><
All channels
2 ns – 4.2 s
1 ns
Pulse Trigger
Polarity
Limit Range
Source
Pulse Range
Resolution
+wid , -wid
,,><
All channels
2 ns ~ 4.2 s
1 ns
Video Trigger
Signal Standard
Source
Sync
Trigger condition
NTSC, PAL, 720p/50, 720p/60, 1080p/50, 1080p/60, 1080i/50, 1080i/60, Custom
All channels
Any, Select
Line, Field
9
SPECIFICATIONS
Window Trigger
Window Type
Source
Absolute, Relative
All channels
Interval Trigger
Slope
Limit Range
Source
Time Range
Resolution
Rising, Falling
,,><
All channels
2 ns ~ 4.2 s
1 ns
Dropout Trigger
Timeout Type
Source
Slope
Time Range
Resolution
Edge, State
All channels
Rising, Falling
2 ns ~ 4.2 s
1 ns
Runt Trigger
Polarity
Limit Range
Source
Time Range
Resolution
+wid , -wid
,,><
All channels
2 ns ~ 4.2 s
1 ns
Pattern Trigger
Pattern Setting
Logic
Source
Limit Range
Time Range
Resolution
Invalid, Low, High
AND, OR, NAND, NOR
All channels
,,><
2 ns ~ 4.2 s
1 ns
Serial Trigger
I2C Trigger
Condition
Source (SDA/SCL)
Data format
Limit Range
Data Length
R/W bit
SPI Trigger
Condition
Source (CS/CL/Data)
Data format
Data Length
Bit Value
Bit Order
10
Start, Stop, Restart, No Ack, EEPROM, 7 bits Address & Data, 10 bits Address & Data,
Data Length
All channels
Hex
EEPROM: =, >, <
EEPROM: 1 byte
Addr & Data: 1 ~ 2 byte
Data Length: 1 ~ 12 byte
Addr & Data: Read, Write, Don’t care
Data
All channels
Binary
4 ~ 96 bit
0, 1, X
LSB, MSB
UART / RS232 Trigger
Condition
Source (RX/TX)
Data format
Limit Range
Data Length
Data Width
Parity Check
Stop Bit
Idle Level
Baud (Selectable)
(Custom)
CAN Trigger
Condition
Source
ID
Data Format
Data Length
Baud Rate (Selectable)
Baud Rate (Custom)
LIN Trigger
Condition
Source
ID
Data Format
Data Length
Baud Rate (Selectable)
Baud Rate (Custom)
Start, Stop, Data, Parity Error
All channels
Hex
=, >, <
1 byte
5 bit, 6 bit, 7 bit, 8 bit
None, Odd, Even
1 bit, 1.5 bit, 2 bit
High, Low
600/1200/2400/4800/960019200/38400/57600/115200 bit/s
300 bit/s ~ 334000 bit/s
All, Remote, ID, ID + Data, Error
All channels
STD (11 bit), EXT (29 bit)
Hex
1~2 byte
5 k/10 k/20 k/50 k/100 k/125 k/250 k/500 k/800 k/1 M bit/s
5 kbit/s ~ 1 Mbit/s
Break, Frame ID, ID+Data, Error
All channels
1 byte
Hex
1 ~ 2 byte
600/1200/2400/4800/9600/19200 bit/s
300 bit/s ~ 20 kbit/s
Serial Decoder
I2C Decoder
Signal
Address
Threshold
List
SPI Decoder
Signal
Edge Select
Idle Level
Bit Order
Threshold
List
UART / RS232 Decoder
Signal
Data Width
Parity Check
Stop Bit
Idle Level
Threshold
List
CAN Decoder
Signal
Source
Threshold
List
LIN Decoder
LIN Specification Package Revision
Threshold
List
SCL, SDA
7 bits, 10 bits
-4.5 ~ 4.5 div
1 ~ 7 lines
SCL,MISO, MOSI, CS * NOTE 2 channel scopes can only use 2 signal identifiers
Rising, Falling
Low, High
MSB, LSB
-4.5 ~ 4.5 div
1 ~ 7 lines
RX, TX
5 bit, 6 bit, 7 bit, 8 bit
None, Odd, Even
1 bit, 1.5 bit, 2 bit
Low, High
-4.5 ~ 4.5 div
1 ~ 7 lines
CAN_H, CAN_L
CAN_H, CAN_L, CAN_H-CAN_L
-4.5 ~ 4.5 div
1 ~ 7 lines
Ver1.3, Ver2.0
-4.5 ~ 4.5 div
1 ~ 7 lines
11
SPECIFICATIONS
Measurement
Source
Number of Measurements
Measurement Range
Measurement Parameters (38 Types)
Vertical (Voltage)
Horizontal( Time)
Delay
Cursors
Statistics
Counter
12
All channels, All channels in Zoom, Math, All References, History
Display 5 measurements at the same time
Screen region, Gate region
Max
Highest value in input waveform
Min
Lowest value in input waveform
Pk-Pk
Difference between maximum and minimum data values
Ampl Difference between top and base in a bimodal signal, or between max and
min in an unimodal signal
Top
Value of most probable higher state in a bimodal waveform
Base
Value of most probable lower state in a bimodal waveform
Mean
Average of all data values
Cmean
Average of data values in the first cycle
Stdev
Standard deviation of all data values
Cstd
Standard deviation of all data values in the first cycle
VRMS
Root mean square of all data values
Crms
Root mean square of all data values in the first cycle
FOV
Overshoot after a falling edge; (base-min)/Amplitude
FPRE
Overshoot before a falling edge; (max-top)/Amplitude
ROV
Overshoot after a rising edge; (max-top)/Amplitude
RPRE
Overshoot before a rising edge; (base-min)/Amplitude
Level@X
the voltage value of the trigger point
Period
Period for every cycle in waveform at the 50 % level, and positive slope
Freq
Frequency for every cycle in waveform at the 50 % level, and positive slope
+Wid
Width measured at 50 % level and positive slope
-Wid
Width measured at 50 % level and negative slope
Rise Time Duration of rising edge from 10 – 90 %
Fall Time
Duration of falling edge from 90 – 10 %
Bwid Time from the first rising edge to the last falling edge, or the first falling edge
to the last rising edge at the 50 % crossing
+Dut
Ratio of positive width to period
-Dut
Ratio of negative width to period
Delay
Time from the trigger to the first transition at the 50 % crossing
Time@Level Time from the trigger to each rising edge at the 50 % crossing.
When Statistics is Off, it shows the time from the trigger to the last rising
edge at the 50 % crossing.
When Statistics is On, it shows the Current, Mean, Min, Max, Standard
Deviation of time from the trigger to each rising edge at the 50 % crossing
in multiple frames (number = Count).
Phase
Calculate the phase difference between two edges
FRR
Time between the first rising edges of the two channels
FRF
Time from the first rising edge of channel A to the first falling edge of channel B
FFR
Time from the first falling edge of channel A to the first rising edge of channel B
FFF
Time from the first falling edge of channel A to the first falling edge of channel B
LRR
Time from the first rising edge of channel A to the last rising edge of channel B
LRF
Time from the first rising edge of channel A to the last falling edge of channel B
LFR
Time from the first falling edge of channel A to the last rising edge of channel B
LFF
Time from the first falling edge of channel A to the last falling edge of channel B
Skew
Time of source A edge minus time of nearest source B edge
Manual : Time X1, X2, (X1-X2), (1/ΔT) Voltage Y1, Y2, (Y1-Y2)
Track: Time X1, X2, (X1-X2)
Current, Mean, Min, Max, Stdev, Count
Hardware 6 bit counter( channels are selectable)
Math Function
Operation
FFT window
FFT display
Number of Decoders
+ , - , * , / , FFT , d/dt , ∫dt , √
Rectangular, Blackman, Hanning, Hamming, Flattop
Full Screen, Split, Exclusive
2
USB AWG Module (four channel series only, option)
Channel
Max. Output Frequency
Sampling Rate
Frequency Resolution
Frequency Accuracy
Vertical Resolution
AmplitudeRange
Waveform Type
Output impedance
Protection
1
25 MHz
125 MSa/s
1 μHz
± 50 ppm
14-bits
-1.5 ~ +1.5 V (50 Ω)
-3 ~ +3 V (High-Z)
Sine, Square, Ramp, pulse, Noise, DC and 45 built-in waveforms
50 Ω ± 2 %
Over-Voltage Protection, Current-Limiting Protection
Sine
Frequency
Offset Accuracy (10 kHz)
Amplitude flatness (10 kHz, 5 Vpp)
SFDR
HD
1 μHz ~ 25 MHz
± (1 % * Offset Setting Value + 1 mVpp)
± 0.3 dB
DC ~ 1 MHz -60 dBc
1 MHz ~ 5 MHz -55 dBc
5 MHz ~ 25 MHz -50 dBc
DC ~ 5 MHz -50 dBc
5 MHz ~ 25 MHz -45 dBc
Square/Pulse
Frequency
Duty Cycle
Rise/Fall time
Overshoot (1 kHz,1 Vpp, Typical)
Pulse Width
Jitter
1 μHz ~ 10 MHz
1 % ~ 99 %
< 24 ns (10 % ~ 90 %)
< 3 % (typical 1 kHz, 1 Vpp)
> 50 ns
< 500 ps + 10 ppm
Ramp
Frequency
Linearity (Typical)
Symmetry
1 μHz ~ 300 kHz
< 0.1 % of Pk-Pk (Typical, 1 kHz, 1 Vpp, 100 % Symmetry)
0 % ~ 100 % (Adjustable)
DC
Offset range
Accuracy
± 1.5 V (50 Ω)
± 3 V (High-Z)
± (|offset| * 1 % + 3 mV)
Noise
Bandwidth
> 25 MHz (-3 dB)
Arbitrary Wave
Frequency
Wave Length
Sampling Rate
Waveform Entry
1 μHz ~ 5 MHz
16 kpts
125 MSa/s
EasyScope and USB-Stick
13
SPECIFICATIONS
Digital Channels (four channel series only, option)
No. of Channels
Max. Sampling Rate
Memory Depth
Min. Detectable Pulse Width
Level Group
Level Range
Logic Type
Skew[2]
16
1 GSa/s
14 Mpts/CH
4 ns
D0~D7, D8~D15
-8 V ~ 8 V
TTL, CMOS, LVCMOS3.3, LVCMOS2.5, custom
D0~D15: ±1 sampling interval
Analog To Digital: ± (1 sampling interval +1 ns)
I/O
Standard
Pass/Fail
USB Host, USB Device, LAN, Pass/Fail, Trigger Out
3.3 V TTL Output
Display (Screen)
Display Type
Display Resolution
Display Color
Contrast (Typical)
Backlight
Range
7-inch TFT LCD
800 × 480
24 bit
500:1
300 nit
8 x 14 divisions
Display (Waveform)
Display Mode
Persist Time
Color Display
Screen Saver
Language
Dot, Vector
Off, 1 Sec, 5 Sec, 10 Sec, 30 Sec, Infinite
Normal, Color
1 min, 5 min, 10 min, 30 min, 1 hour, Off
Simplified Chinese, Traditional Chinese, English, French, Japanese, Korean, German,
Russian, Italian, Portuguese
Environments
Temperature
Humidity
Height
Electromagnetic Compatibility
Safety
Operating: 10 ~ +40
Non-operating: -20 ~ +60
Operating: 85 % RH, 40 Deg C, 24 hours
Non-operating: 85 % RH, 65 Deg C, 24 hours
Operating: ≤ 3000 m
Non-operating: ≤ 15,266 m
2004/108/EC)
Execution Standard EN 61326-1:2006
EN 61000-3-2:2006 + A2:2009, EN 61000-3-3:2008
2006/95/EC
Execution Standard EN 61010-1:2010 / EN 61010-2-030:2010
Power Supply
Input Voltage
Frequency
Power
100 ~ 240 VAC, CAT II, Auto selection
50/60/400 Hz
25 W Max
Mechanical (Four channel series)
Dimensions
Weight
Length: 312 mm / Width: 132.6 mm / Height: 151 mm
N.W: 2.6 kg; G.W: 3.8 kg
Mechanical (Two channel series)
Dimensions
Weight
14
Length: 312 mm / Width: 134 mm / Height: 150 mm
N.W: 2.5 Kg; G.W: 3.5 Kg
Probes and Accessories
Probe
Model
Passive Probes
T3PP300
Picture
Passive Probe, Bandwidth: 300 MHz
Description
Current Probes
T3CP50
Bandwidth: 50 MHz, Max. continuous current: 30 Arms,
Peak current: 50 A
Switch Ratio: 100 mV/A, 1 V/A, Accuracy: 1 V/A (±1 % ±1 mA),
100 mV/A (±1 % ±10 mA), DC 12 V /1.2 A power adapter
Differential
Voltage Probes
T3DP7000
Bandwidth: 100 MHz
Differential Range: 7000 V (DC + Peak AC),
100X/1000X, Accuracy: ±2 %, DC 5 V/1 A USB adapter
High Voltage
Probe
T3HVP100
Bandwidth: 40 MHz
Voltage Range: DC 10 KV, AC (rms): 7 KV (sine), AC (Vpp): 20 KV (Pulse)
1000X, Accuracy: ≤ 3 %
USB AWG Module
T3DSO1000FGMOD
Output Sine, Square, Ramp, pulse, Noise, DC and 45 built-in waveforms.
The arbitrary waveforms can be accessed and edited by the EasyScope
PC software
Ordering information
Product Name
Standard Accessories
Optional Accessories
T3DSO1102 100 MHz Two Channels
T3DSO1104 100 MHz Four Channels
T3DSO1204 200 MHz Four Channels
USB Cable -1
Quick Start -1
Passive Probe -4 / 2
Certification -1
Power Cord -1
16 Channel MSO Software (four channel series only)
T3DSO1000-MSO
16 Channel Logic Analyzer Lead (four channel series only) T3DSO1000-LS
(Requires T3MSO1000 Software)
AWG Software (four channel series only)
T3DSO1000-FG
USB AWG Module Hardware (four channel series only)
T3DSO1000-FGMOD
(Requires T3DSO1000-FG)
WIFI Software (four channel series only)
T3DSO1000-WIFI
High Voltage Probe
T3HVP100
Current Probes
T3CP50
Differential Probes
T3DP7000
15
ABOUT TELEDYNE TEST TOOLS
Company Profile
Teledyne LeCroy is a leading provider of oscilloscopes, protocol
analyzers and related test and measurement solutions that
enable companies across a wide range of industries to design
and test electronic devices of all types. Since our founding
in 1964, we have focused on creating products that improve
productivity by helping engineers resolve design issues
faster and more effectively. Oscilloscopes are tools used by
designers and engineers to measure and analyze complex
electronic signals in order to develop high-performance
systems and to validate electronic designs in order to improve
time to market.
The Teledyne Test Tools brand extends the Teledyne LeCroy
product portfolio with a comprehensive range of test
equipment solutions. This new range of products delivers
a broad range of quality test solutions that enable engineers
to rapidly validate product and design and reduce time-tomarket. Designers, engineers and educators rely on Teledyne
Test Tools solutions to meet their most challenging needs for
testing, education and electronics validation.
Location and Facilities
Headquartered in Chestnut Ridge, New York, Teledyne
Test Tools and Teledyne LeCroy has sales, service and
development subsidiaries in the US and throughout
Europe and Asia. Teledyne Test Tools and Teledyne LeCroy
products are employed across a wide variety of industries,
including semiconductor, computer, consumer electronics,
education, military/aerospace, automotive/industrial, and
telecommunications.
Distributed by:
Teledyne LeCroy
(US Headquarters)
700 Chestnut Ridge Road
Chestnut Ridge, NY. USA 10977-6499
Phone:
Fax Sales:
Phone Support:
Email Sales:
Email Support:
Web Site:
800-553-2769 or 845-425-2000
845-578-5985
1-800-553-2769
contact.corp@teledynelecroy.com
support@teledynelecroy.com
http://teledynelecroy.com/
Teledyne LeCroy
(European Headquarters)
Teledyne LeCroy GmbH
Im Breitspiel 11c
D-69126 Heidelberg, Germany
Phone:
Fax:
Phone Service:
Phone Support:
Email Sales:
Email Service:
Email Support:
Web Site:
+49 6221 82700
+49 6221 834655
+49 6221 8270 85
+49 6221 8270 28
contact.gmbh@teledynelecroy.com
service.gmbh@teledynelecroy.com
tlc.t3.appsupport.eu@teledyne.com
http://teledynelecroy.com/germany
teledynelecroy.com
© 2018 Teledyne Test Tools is a brand and trademark of Teledyne LeCroy Inc. All rights reserved. Specifications, prices, availability and delivery subject to change without notice.
Product brand or brand names are trademarks or requested trademarks of their respective holders.
T3 stands for Teledyne Test Tools.