0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
T3LCR1300

T3LCR1300

  • 厂商:

    TELEDYNE

  • 封装:

  • 描述:

    测试元件 LCR 测试仪

  • 数据手册
  • 价格&库存
T3LCR1300 数据手册
T3LCR1002, T3LCR1100, T3LCR1300 Precision LCR Meters Datasheet Measure With Confidence 10Hz - 300KHz Tools for Improved Debugging ● Clear visibility of your power settings. 3.5” Large TFT LCD Display. Consecutive and adjustable frequency within provided frequency range. ● Flexibility in choosing measuring frequency for various components. ● Basic Accuracy of 0.05%. Measurements will be faster as well as accurate. ● Provides PASS/FAIL Judgement function. Helps in faster validation process. Standard Interface: RS-232C, Handler, USB and USB Storage. ● ● Support for the maximum control flexibility. Reliable product gives peace of mind. 3 years warranty as standard. Key Specifications Model Test Frequency Resolution Measuring Speed T3LCR1002 10Hz - 2KHz 4 digits FAST: 25ms T3LCR1100 10Hz - 100KHz 4 digits MED: 100ms T3LCR1300 10Hz - 300KHz 4 digits SLOW: 33ms PRODUCT OVERVIEW Teledyne Test Tools introduces the brand new series of high precision LCR meters. The T3LCR series offers three models with maximum test frequency ranging from 2kHz to 300kHz and basic accuracy of 0.05%. The compact size design, 2U height and 1/2 rack, is one of the practical features of the series which is the optimum space saver suitable for either bench top or system rack. The compacted T3LCR series with abundant features is absolutely the excellent tool for R&D, production test, IQC, etc. on implementing each test stages for passive components. The T3LCR series provides a rich set of functionalities while maintaining a compact size. The entire series adopts 3.5-inch color LCD and features opulent display parameters. In addition to simultaneously displaying setting criteria and measurement results, the series increases two additional monitoring parameters. The four parameters (primary+secondary and two monitoring) are simultaneously shown on the screen that tremendously enhances the measurement efficiency. The enlarge display mode not only emphasizes the measurement results, but also provides PASS/FAIL judgment to facilitate a rapid and convenient test result. Convenience is one of the unique features. The T3LCR series comes equipped with full frequency range zero and spot zero selections. Users can freely change frequency within the provided frequency range to conduct measurements without having to power off the instrument or changing test fixture. This feature is particularly useful for repeated zeroing operation and saves a tremendous amount of time for the user. Additionally, frequency range of the series is consecutive that allows users to input precise frequency value to conduct the most genuine test on components. The T3LCR series also features diverse ancillary measurements to meet the measurement requirements of different materials. For instance, the series provides the automatic level control (ALC) function to satisfy the test voltage requirement of MLCC. For inductive component measurements, the series provides the adjustable test current function and the D.C. resistance measurement function. With respect to the D.C. bias voltage test for capacitive components requirements, the series allows users to conduct verification measurement on materials by its internal ±2.5V adjustable voltage. Furthermore, 10 steps of listed test functionalities allow users to set testing parameters (either by frequency, or voltage, or current) for each step based on users' requirements in order to observe the trend of DUT characteristics. The T3LCR series has 10 memory sets defined by panel setting criteria to facilitate users in selecting test criteria and saving time in repeated settings. 10,000 measurement result storage capability can easily record measurement results instantaneously. The USB host allows easy access to recorded results without connecting the series to the PC. The USB host also allows USB to retrieve and save screen so as to assist users in compiling setting guidelines. For the external control, theT3LCR series provides handler interface and collocates with its measurement sorting function (9BIN, AUX: 1BIN) to facilitate the connection with sorting machine so as to sort out the materials. For remote control and measurement result retrieval requirements, the T3LCR series provides RS-232C and USB interfaces to assist setting control or measurement result retrieval via the PC commands. Additionally, the free PC software gives users an instant tool to store measurement results that saves time in developing programs. The brand new compact T3LCR series meters can effectively improve the limitation of space. Diverse measurement functionalities and display methods are making the series the best choice in meeting the requirements of R&D, component assessment for engineering departments, category sorting requirements for component production, and IQC for verification on component specifications. 1 1. 3.5” Large TFT LCD Provides Setting Parameters and Measurement Result Observation Simultaneously 2. Corresponding Funcitonal Keys Provide More Intutive And Fast Operation 3. USB host for Data Storage and Display Screen Retrival 4. Four Wire Measurement Terminal 5. Universal Power Input AC 100-240V 6. USB Interface (Type B) 7. RS-232C Port 8. Handler Port 2 4 3 6 7 8 5 FEATURES Features • 3.5” Color LCD Display • DCR Measurement and Internal D.C. Bias Voltage(±2.5V) • Consecutive test frequency • PASS/FAIL Judgement • Basic Accuracy of 0.05% • Auto Level Control (ALC) Function • Measuring speed upto 25ms (max) • BIN Function Provides 9BIN and 1AUX, Totally 10BIN • Full Frequency range or SPOT OPEN/SHORT • 10 Steps listed tests to select different Frequecny, Voltage • 16 Major/Secondary Parameter Measurement Combinations and 2 additional Monitoring Parameters (maximum four and Current Criteria • Standard Interface: RS232C, USB, Handler and USB Storage • Compact Size, Ideal for Automatic Equipment (2U, 1/2 Rack) different parameters can be shown simultanously) A. Consecutive Frequencyand Convenient Zero Function Consecutive and Adjustable Frequency SelectableFixture Zeroing Methods Freely Input FrequencyWithin Provided Frequency Range Full FrequencyRange Zero or Spot Zero B. Rich and Diverse Information Display MEAS Display ENLARGEDisplay Parameter Setting and Four Measurement Parameters Enlarge Measurement Results and Include PASS/FAIL Judgment The T3LCR series, within the provided frequency range, features The measurement result display of the T3LCR series not only consecutive and adjustable frequency capability which allows displays major and secondary measurement parameters but users to conduct measurement and analysis on components also includes two monitoring parameters. Therefore, four DUT with the most genuine frequency requirements. For OPEN/ related parameters can be simultaneously shown on the SHORT fixture compensation function, the T3LCR series is display screen to save time if repeated measurements are equipped with full frequency range zero and spot zero selections. required. With respect to display screen, the T3LCR series After executing full frequency range users can freely change test features diverse display to meet user observation requirements. frequency to execute component measurements without having For instance, MEAS display shows setting parameters and to power off the instrument or changing the test fixture. This measurement results at the same time; ENLARGE display allows for a faster measurement time during repeated zeroing focuses on measurement results and PASS/FAIL judgment is operations. available, which assists engineers to swiftly obtain the validity of measurement results. FEATURES C. Diverse Ancillary Measurement Functions Automatic Level Control Internal Bias(±2.5V Adjustable) D.C. ResistanceMeasurement Ideal for Measuring Components With Voltage Requirements Ideal for Capacitive Components' Characteristic Tests Ideal for inductive components' D.C. Characteristics Verification To satisfy the diverse measurement application requirements for different components and materials, the T3LCR series offers many auxiliary measurement functions. Automatic Level Control (ALC) fucntion is mainly for components which requires a constant or rated test voltage such as multilayer ceramic capacitor (MLCC). An internal D.C. bias voltage (±2.5V) allows simulating A.C and D.C simultanously to measure the capacitance variation. For measurements involving inductors, the D.C. resistance measurement function allows the user to validate D.C. Resistance characteristics. Additionally, the Auto LCZ function helps in selection of proper measurement parameters automatically. The Auto LCZ fuction, when activated will automatically determine the characteristics of the DUT and dispay the optimum measurement parameters. D. 10 Points Listed Tests and PC Software Listed Tests On Software - Characteristic Curve Variation Criteria BasedUpon Frequencyor Voltage/Current Provide More Delicate Characteristic Variation Trend E. Standard Interface Standard Interface The T3LCR series provides the 10 points listed test function, For interface connectivity, the T3LCR series comes equipped which allows users to define a set of DUT measurement with Handler interface, RS-232C and USB interface. Handler parameters (such as Cs-Rs) and to set 10 test criteria of outputs 10 BIN (9BIN, AUX: 1BIN) sorting results that is best for category (either by frequency or by voltage or by current) but external connection control, for instance, connecting to a sorting different values to conduct measurements. Through this machine to conduct components 'sorting operation. RS-232C function, users can rapidly and clearly obtain DUT 's and USB is suitable for remote control and measurement results characteristic variation trend to determine the adaptability of retrieval. The PC gives commands to control settings or to read DUT 's practical applications. The measurement results can be measurement results so as to achieve the requirements of recorded directly in the internal memory and be transferred to the PC through USB. The T3LCR series also provides free PC software (maximum 1,000 points listed tests) in order to satisfy users' analytical requirements on delicate variation. verifying automotive applications. SPECIFICATIONS SPECIFICATIONS TEST FREQUENCY T3LCR1300 : 10Hz ~ 300kHz(±0.01%) (4 digits resolution) T3LCR1100 : 10Hz ~ 100kHz(±0.01%) (4 digits resolution) T3LCR1002 : 10Hz ~ 2kHz(±0.01%) (4 digits resolution) OUTPUT IMPEDANCE BASIC ACCURACY 30Ω / 50Ω / 100Ω selectable Slow / Med 0.05% Fast 0.1% TEST SPEED FAST : 25ms / MED : 100ms / SLOW : 333ms TEST SIGNAL LEVELS AC Voltage 10.00mV- 2.00V (±10%) CV : 10.00mV- 2.00V (±6%) Current 100.0 A- 20.00mA (±10%) CC : 100.0 A- 20.00mA(±6%) (@2VMax) DCR ±1V(2Vpp), Square wave, 3Hz up 0.033A(Max) DC BIAS Internal ±2.5V (0.5% + 0.005V) DISPLAY RANGE R, X, |Z| 0.00001Ω ~ 99.9999MΩ G, B, |Y| 0.01nS ~ 999.999S L 0.00001 H ~ 9999.99H C 0.00001pF ~ 9999.99mF D 0.00001 ~ 9.99999 Q 0.00001 ~ 9.99999 θd -179.999° ~ 179.999° θr -3.14159 ~ 3.14159 DCR 0.00001Ω ~ 99.9999MΩ Δ% -99999% ~ 99999% Combinations Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q, Rs-Q, Rp-Q, R-X, DCR, Z- θr, Z- θd, Z-D, Z-Q, Auto LCZ Monitor Parameter (2 Selectable) Z, D, Q, Vac, Iac, Δ, Δ%, θr, θd, R, X, G, B, Y TEST MODE LISTED MODE 10 steps BIN FUNCTION Comparator (9BIN,AUX:1BIN) MEMORY OTHER FUNCTION INT – Panel Setting 10 file name INT – Measured Data 10000 Data(.csv) USB Storage 10 file name for setting, 9999 file name for data, 999 Log file for LCD screen Auto Level Control (ALC) ON/OFF Average 1~256 times Trigger INT / MAN / EXT / BUS Delay 0ms~60s Judgment PASS / FAIL Screen Capture Saving in to USB (Bmp form) DISPLAY 3.5" LCD, RGB color (320x240) INTERFACE RS-232(SCPI), Handler, USB POWER SOURCE AC 100V ~ 240V, 50 ~ 60Hz, Max. 30W DIMENSIONS & WEIGHT 265(W) x 107(H) x 312(D) mm ; Approx. 3kg ORDERING INFORMATION T3LCR1002 LCR Meter 10Hz - 2KHz High Precision T3LCR1100 LCR Meter 10Hz - 100KHz High Precision T3LCR1300 LCR Meter 10Hz - 300KHz High Precision STANDARD ACCESSORIES Qty. Test Lead 1 Power Cord 1 D-SUB 1 ABOUT TELEDYNE TEST TOOLS Company Profile Teledyne LeCroy is a leading provider of oscilloscopes, protocol analyzers and related test and measurement solutions that enable companies across a wide range of industries to design and test electronic devices of all types. Since our founding in 1964, we have focused on creating products that improve productivity by helping engineers resolve design issues faster and more effectively. Oscilloscopes are tools used by designers and engineers to measure and analyze complex electronic signals in order to develop high-performance systems and to validate electronic designs in order to improve time to market. The Teledyne Test Tools brand extends the Teledyne LeCroy product portfolio with a comprehensive range of test equipment solutions. This new range of products delivers a broad range of quality test solutions that enable engineers to rapidly validate product and design and reduce time-tomarket. Designers, engineers and educators rely on Teledyne Test Tools solutions to meet their most challenging needs for testing, education and electronics validation. Location and Facilities Headquartered in Chestnut Ridge, New York, Teledyne Test Tools and Teledyne LeCroy has sales, service and development subsidiaries in the US and throughout Europe and Asia. Teledyne Test Tools and Teledyne LeCroy products are employed across a wide variety of industries, including semiconductor, computer, consumer electronics, education, military/aerospace, automotive/industrial, and telecommunications. Teledyne LeCroy (US Headquarters) 700 Chestnut Ridge Road Chestnut Ridge, NY. USA 10977-6499 Phone: 800-553-2769 or 845-425-2000 Fax Sales: 845-578-5985 Phone Support: 1-800-553-2769 Email Sales: contact.corp@teledynelecroy.com Email Support: support@teledynelecroy.com Web Site: http://teledynelecroy.com/ Teledyne LeCroy (European Headquarters) Teledyne LeCroy GmbH Im Breitspiel 11c D-69126 Heidelberg, Germany Distributed by: Phone: Fax: Phone Service: Phone Support: Email Sales: Email Service: Email Support: Web Site: +49 6221 82700 +49 6221 834655 +49 6221 8270 85 +49 6221 8270 28 contact.gmbh@teledynelecroy.com service.gmbh@teledynelecroy.com tlc.t3.appsupport.eu@teledyne.com http://teledynelecroy.com/germany teledynelecroy.com © 2018 Teledyne Test Tools is a brand and trademark of Teledyne LeCroy Inc. All rights reserved. Specifications,prices,availability and delivery subject to change without notice. Product brand or brand names are trademarks or requested trademarks of their respective holders. T3 stands for Teledyne Test Tools. 24Sep2021
T3LCR1300 价格&库存

很抱歉,暂时无法提供与“T3LCR1300”相匹配的价格&库存,您可以联系我们找货

免费人工找货