0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
T3SA3000-ADM

T3SA3000-ADM

  • 厂商:

    TELEDYNE

  • 封装:

  • 描述:

    SPECT ANLYZR ADV MEAS KIT W/ACPR

  • 数据手册
  • 价格&库存
T3SA3000-ADM 数据手册
T3SA3100 / T3SA3200 Data Sheet 2.1 GHz and 3.2 GHz Spectrum Analyzers Broad Measurement Range Frequency Range: 9 kHz to 2.1 GHz / 3.2 GHz Tools for Improved Debugging ●● Frequency Range from 9 kHz to 3.2 GHz.  More application coverage from a single Spectrum Analyzer. ●● -161 dBm/Hz Displayed Average Noise Level (Typ.)  View and measure very small signals. -98 dBc/Hz @10 kHz Offset Phase Noise (1 GHz, Typ.)  Improved specification gives more accurate measurement results. Optional Tracking Generator Optional EMI Pre-compliance Test Kit Optional Reflection Measurement Kit  Make fast and simple transmission measurements Make EMI Receiver measurements to CISPR 16-1-1 Measure VSWR, Return Loss, Reflection Coefficient ●● Built-in switchable pre-amplifier.  Integrated pre-amplifier allows higher sensitivity measurements. ●● 10.1 inch (25.65 cm) color WVGA 1024 x 600 display.  Clear and flexible display aids ease of use. ●● USB Device, USB Host and LAN support.  Remote control your measurements. ●● ●● Key Specification Model T3SA3200 T3SA3100 Frequency Range 9 kHz ~ 3.2 GHz 9 kHz ~ 2.1 GHz Resolution Bandwidth 1 Hz ~ 1 MHz, in 1-3-10 sequence 1 Hz ~ 1 MHz, in 1-3-10 sequence Displayed Average Noise Level -161 dBm/Hz, Normalize to 1 Hz (typ.) -161 dBm/Hz, Normalize to 1 Hz (typ.) Phase Noise < -98 dBc/Hz@1 GHz, 10 kHz offset < -98 dBc/Hz@1 GHz, 10 kHz offset Amplitude Precision < 0.7 dB < 0.7 dB PRODUCT OVERVIEW Teledyne Test Tools T3SA3000 Spectrum Analyzer range consists of models with frequency ranges from 9 kHz to 2.1 GHz or 9 kHz to 3.2 GHz. The small footprint and easy user interface is augmented by a high performance specification with many advanced measurement functions and capabilities. The high performance Spectrum Analysis capability can be enhanced further with options to extend it’s measure­ ment capability. ●● ●● ●● ●● Optional Tracking Generator: Adds tracking generator capabilities to your Spectrum Analyzer to make transmission measurements on back planes, cables, filters, amplifiers, etc. Optional EMI Pre-compliance test kit: Add EMI Receiver Measurements following CISPR 16-1-1. Optional Reflection Measurement Kit: Adds VSWR, Return Loss and Reflection Coefficient measurements. Optional Advanced Measurement kit: Adds channel power, adjacent channel power ratio, time domain power, occupied bandwidth, third order intercept, etc, to further enhance the measurement capability of your spectrum analyzer. Teledyne Test Tools spectrum analyzers offer comprehensive measurement capabilities even in the base units. The enhancement options support the user when conducting more complex measurements and make daily measurement tasks easier and faster. Typical Applications ●● Research Laboratory ●● Development Laboratory ●● Repair and Maintenance ●● Calibration Laboratory ●● Automatic Production Test ●● General bench-top use 2 User-friendly Design ●● 10.1 inch (25.65 cm) 1024*600 display ●● Intuitive, easy to use menu system ●● “Preset” and “Auto Tune” for quick set up ●● Built-in front panel accessible help system ●● File management (support for U-disc and local storage) ●● Lightweight, small footprint, easy to transport Features and Benefits ●● Frequency Range from 9 kHz up to 3.2 GHz ●● -161 dBm/Hz Displayed Average Noise Level (Typ.) ●● -98 dBc/Hz @10 kHz Offset Phase Noise (1 GHz, Typ.) ●● Total Amplitude Accuracy < 0.7 dB ●● 1 Hz Minimum Resolution Bandwidth (RBW) ●● All-Digital IF Technology ●● Standard Preamplifier ●● Up to 3.2 GHz Tracking Generator Kit (Opt.) ●● Reflection Measurement Kit (Opt.) ●● Advanced Measurement Kit (Opt.) ●● EMI Pre-compliance Test Kit (Opt.) ●● 10.1 lnch WVGA (1024 x 600) Display DESIGN FEATURES Supports four independent traces and cursors -151 dBm Displayed Average Noise Level (RBW = 10 Hz) 1 Hz Minimum Resolution Bandwidth (RBW) Zero span and demodulation capabilities Phase noise -98 dBc/Hz @ 1 GHz, offset 10 kHz On-screen VSWR/Return Loss measurements with the reflection measurement option (T3SA3000-RFM) EMI filter and Quasi-Peak detector following CISPR 16-1-1 ( T3SA3000-EMI) Advanced measurement kit (T3SA3000-ADM) includes on-screen ACPR measurements 3 SPECIFICATIONS Specifications are valid under the following conditions: The instrument is within the calibration period, has been stored between 0 and 50°C for at least 2 hours prior to use, and has been powered on and warmed up for at least 40 minutes. The specifications include the measurement uncertainty, unless otherwise noted. Specifications: All products are guaranteed to meet published specifications when operating in temperatures from 5 to 45 °C, unless otherwise noted. Typical: Performance deemed typical implies that 80 percent of the measurement results will meet the typical published performance with a 95th percentile confidence level at room temperature (approximately 25 °C). Typical performance is not warranted and does not include measurement uncertainty. Nominal: The expected performance or design attribute. Frequency Characteristic T3SA3200 T3SA3100 9 kHz – 3.2 GHz 1 Hz 9 kHz – 2.1 GHz 1 Hz 0 Hz, 100 Hz to 3.2 GHz ± Span / (number of sweep points - 1) 0 Hz, 100 Hz to 2.1 GHz Frequency Frequency range Frequency resolution Frequency Span Range Accuracy Internal Reference Source Reference frequency Frequency reference accuracy Initial calibration accuracy Temperature stability Frequency aging rate 10.000000 MHz ± [(time since last adjustment × frequency aging rate) + temperature stability + calibration accuracy] < 1 ppm < 1 ppm/year, 0 °C ~ 50 °C < 0.5 ppm/first year, 3.0 ppm/20 years Marker Marker resolution Marker uncertainty Frequency counter resolution Frequency counter uncertainty Span / (number of sweep points - 1) ± [frequency indication × frequency reference uncertainty + 1 % × span + 10 % × resolution ­bandwidth + marker resolution] 1 Hz ± [frequency indication × frequency reference accuracy + counter resolution] Bandwidths Resolution bandwidth (-3 dB) Resolution filter shape factor RBW uncertainty Video bandwidth (-3 dB) VBW uncertainty 1 Hz ~ 1 MHz 1), in 1-3-10 sequence < 4.8:1 (60 dB:3 dB), Gaussian-like < 5 % 1 Hz ~ 3 MHz, in 1-3-10 sequence < 5% The DANL with RBW set to 1 or 3 Hz will be similar to 10 Hz. 1) 4 SPECIFICATIONS Amplitude Characteristic T3SA3200 T3SA3100 Amplitude and Level Measurement range DANL to +10 dBm, 100 kHz ~ 1 MHz, preamplifier off DANL to +20 dBm, 1 MHz ~ 3.2 GHz, preamplifier off Reference level -100 dBm to +30 dBm, 1 dB steps Preamplifier 20 dB (nom.), 9 kHz ~ 3.2 GHz Input attenuation 0 ~ 51 dB, 1 dB steps Maximum input DC voltage ± 50 VDC Maximum average RF power 30 dBm, 3 minutes, fc ≥ 10 MHz, attenuation > 20 dBm, preamp off Maximum damage level 33 dBm, fc ≥ 10 MHz, attenuation > 20 dBm, preamp off Displayed Average Noise Level (DANL) 20 °C ~ 30 °C, attenuation = 0 dB, sample detector, trace average > 50 Preamp off RBW = 10 Hz Normalization to 1 Hz 9 kHz ~ 100 kHz -100 dBm (nom.) -110 dBm (nom.) 100 kHz ~ 1 MHz -97 dBm, -101 dBm (typ.) -107 dBm, -111 dBm (typ.) 1 MHz ~ 10 MHz -122 dBm, -126 dBm (typ.) -132 dBm, -136 dBm (typ.) 10 MHz ~ 200 MHz -127 dBm,-131 dBm (typ.) -137 dBm, -141 dBm (typ.) 200 MHz ~ 2.1 GHz -125 dBm, -129 dBm (typ.) -135 dBm, -139 dBm (typ.) 2.1 GHz ~ 3.2 GHz -116 dBm, -122 dBm (typ.) -126 dBm, -132 dBm (typ.) Preamp on 9 kHz ~ 100 kHz -107 dBm (nom.) -117 dBm (nom.) 100 kHz ~ 1 MHz -122 dBm, -127 dBm (typ.) -132 dBm, -137 dBm (typ.) 1 MHz ~ 10 MHz -138 dBm, -144 dBm (typ.) -148 dBm, -154 dBm (typ.) 10 MHz ~ 200 MHz -146 dBm, -151 dBm (typ.) -156 dBm, -161 dBm (typ.) 200 MHz ~ 2.1 GHz -145 dBm, -148 dBm (typ.) -155 dBm, -158 dBm (typ.) 2.1 GHz ~ 3.2 GHz -135 dBm, -139 dBm (typ.) -145 dBm, -149 dBm (typ.) Phase Noise 20 °C ~ 30 °C, f c= 1 GHz Phase Noise
T3SA3000-ADM 价格&库存

很抱歉,暂时无法提供与“T3SA3000-ADM”相匹配的价格&库存,您可以联系我们找货

免费人工找货