Conductor
Conductor count: 4
Gauge: 18 AWG 0.82 mm2
Material: tinned copper strands
Strand size: Ø 0.16 x 41
Resistance at 20 °C: 23.2 Ω /km max
Insulator
Material: PVC
Color: black, white, red, yellow
Diameter: Ø 1.8 ±0.1 mm
Nominal thickness: 0.29 mm
Resistance at 20 °C: 10 MΩ /km min
Outer jacket
Material: PVC
Color: white
Diameter: Ø 6.0 ± 0.2 mm
Nominal thickness: 0.80 mm
1.8 ±0.10
6 ±0.20
Wire marking: E339579 UL AWM STYLE 2464 18 AWG 80°C
300V VW-1 - - - cUL AWM I/II A 80°C 300V FT1 LF TENSILITY
Tests
Insulation tensile strength: 2.11 kgf/mm2
Jacket tensile strength: 1.05 kgf/mm2
After aging at 113 ±2 °C for 7 days:
Minimum tensile strength 70 % original
Minimum elongation 65 % original
Heat shock: 121 ±1 °C /1 hour, no observed degradation
Deformation: 121 ±1 °C /1 hour, ≤ 50 %
Cold bend: -10 ±2 °C /1 hour, no observed cracking
Jacket
Insulation
Conductor
0. 1
Revision:
A
A1
Date:
06/25/2014
09/06/2018
Description:
Prepared:
GL
Initial release
Verified:
Increased opertating temperature
range
PS
Notes:
Digitally signed by GL
Date: 2018.09.06
13:47:34 -07'00'
RoHS and REACH compliant
Digitally signed by PS
Date: 2018.09.06
14:55:55 -07'00'
Function test: no open, no short circuit, no
intermittent
Dimensions are in
millimeters.
Tolerances:
X:
0.5 mm
X.X:
0.3 mm
X.XX: 0.05 mm
5
4
41
6x
tel
fax
Description:
Wire, 4C TS, 18 AWG, UL2464, 300V, 80C, 6.0 mm,
VW-1, PVC, white
3
2
1.541.323.3228
1.541.323.4202
Size:
Part number:
A
30-00381
Scale:
800
web
877.670.7118
tensility.com
Sheet 1 of 1
10:1
1
To see a custom version of this cable assembly, call Tensility at 541-323-3228 or email engineering@tensility.com
Ratings
Voltage: 300 V
Temperature: -25 ~ 80 °C
Flammability: VW-1