Conductor
Conductor count: 2
Gauge: 26 AWG 0.14 mm2
Material: tinned copper strands
0.16 x 7
Strand size:
Resistance at 20 °C: 150 Ω /km max
Outer jacket
Material: PVC
Color: black
Diameter: 2.7 ±0.15 mm
Nominal thickness: 0.40 mm
Resistance at 20 °C: 10 MΩ /km min
Wire marking: E339579 UL AWM STYLE 2468 26 AWG 80°C
300V VW-1 - - - cUL AWM I A 80°C 300V FT1 TENSILITY
Tests
Insulation tensile strength: 2.11 kgf/mm2
Jacket tensile strength: 1.05 kgf/mm2
After aging at 113 ±2 °C for 7 days:
Minimum tensile strength 70 % original
Minimum elongation 65 % original
Heat shock: 121 ±1 °C /1 hour, no observed degradation
Deformation: 121 ±1 °C /1 hour, ≤ 50 %
Cold bend: -10 ±2 °C /1 hour, no observed cracking
Stripe
Marking
1.35 ±0.10
Jacket
Conductor
0. 1
2.7 ±0.15
Revision:
A
Date:
06/27/2014
Description:
Initial release
A1
01/08/2016
Corrected tolerances
A2
09/06/2018
Increased operating temperature
range
5
Prepared:
AW
Verified:
PS
Digitally signed by AW
Date: 2018.09.06
11:39:43 -07'00'
Digitally signed by PS
Date: 2018.09.06 13:22:25
-07'00'
Dimensions are in
millimeters.
Tolerances:
X:
0.5 mm
X.X:
0.3 mm
X.XX: 0.05 mm
4
6x
7
Notes:
RoHS and REACH compliant
Function test: no open, no short circuit, no
intermittent
tel
fax
Description:
Wire, 2C TS, 26 AWG, UL2468, 300V, 80C, 2.7 mm,
VW-1, PVC
3
2
1.541.323.3228
1.541.323.4202
Size:
Part number:
A
30-00407
Scale:
800
web
877.670.7118
tensility.com
15:1
Sheet 1 of 1
1
To see a custom version of this cable assembly, call Tensility at 541-323-3228 or email engineering@tensility.com
Ratings
Voltage: 300 V
Temperature: -25 ~ 80 °C
Flammability: VW-1