4
2
3
1
9.5
+0.10
3.6 - 0
6 ±0.05
SECTION A-A
A
2.5
1.32 ±0.02
1
2.3
1
A
7 ±0.10
13 ±0.10
16.5 ±0.50
Revision:
A
Date:
10/21/2009
Description:
Prepared:
GL
Intitial release
A1
12/05/2011
Updated description
A2
02/20/2012
Updated drawing
A3
11/09/2012
Added test data
A4
01/23/2018
Changed insulator material
5
Digitally signed by GL
Date: 2019.05.02
15:34:57 -07'00'
Verified:
AG
Digitally signed by AG
Date: 2019.05.02 15:57:56
-07'00'
Dimensions are in
millimeters.
Tolerances:
X:
0.5 mm
X.X:
0.3 mm
X.XX: 0.05 mm
4
Notes:
RoHS compliant
Function test: no open, no short circuit, no
intermittent
tel
fax
Description:
Connector, dc jack, 3.5x1.35xL16.5 mm, molding
style
3
2
1.541.323.3228
1.541.323.4202
Size:
Part number:
A
50-00057
Scale:
800
web
877.670.7118
tensility.com
2:1
Sheet 1 of 2
1
To see a custom version of this cable assembly, call Tensility at 541-323-3228 or email engineering@tensility.com
Materials
1. Spring contact, beryllium copper, 2 μm nickel plated
2. Insulator, PBT+15% GF, black
3. Center contact, C3604 brass, 2 μm nickel plated
4. Shell, C3604 brass, 2 μm nickel plated
Electrical requirements
Dielectric strength: 1 min @ 500 Vac
Insulation resistance: 100 MΩ @ 500 Vdc
Contact resistance: 30 mΩ or less
Mechanical requirements
Insertion force: 0.3-2.5 kgf
Withdrawal force: 0.3-2.5 kgf
Durability: 5000 mating cycles while maintaining; 0.3 kgf
min. insertion force, 0.2 kgf min. withdrawal force and a
less than 100 mΩ contact resistance.
Environmental requirements
Damp test: 40 °C, RH 90-100% for 96 hrs. Cool to ambient
and recover for 2 hours. Maintain dielectric strength of 500
Vac for 1 min, insulation resistance of 50 MΩ @ 500 Vdc
minimum and a contact resistance of 100 mΩ or less.
Dry test: 70 °C, RH 70-85% for 96 hrs. Cool to ambient and
recover for 2 hours. Maintain insulation resistance of 50
MΩ @ 500 Vdc minimum and a contact resistance of 100
mΩ or less.
Salt spray test: 35 °C, RH 90-95%, 5% NaCl mist for 24 hrs.
Wash parts after test. Maintain mechanical requirements
and a contact resistance of less than 80 mΩ.
Operating range
-25 to 70 °C, relative humidity of 85% or less
Ratings
Maximum Operating Voltage: 48 Vdc
Maximum Operating Current: 6.0 A
Operating Temperature Range
-25° to 70°C, relative humidity of 85% or less
Testing based on IEC 60512-5-2. Max current curve generated with isolated test article under controlled environmental conditions,
and does not take into account external factors such as housings,mating cables, or other circuitry. Operating current curve
(derated by 20% of maximum values) accounts for external factors, and manufacturing variation.
Revision:
A
Date:
10/21/2009
Description:
Prepared:
GL
Intitial release
Digitally signed by GL
Date: 2019.05.02
15:35:18 -07'00'
Verified:
A1
12/05/2011
Updated description
AG
A2
02/20/2012
Updated drawing
A3
11/09/2012
Added test data
A4
01/23/2018
Changed insulator material
Dimensions are in
millimeters.
Tolerances:
X:
0.3 mm
X.X:
0.1 mm
X.XX: 0.05 mm
5
4
Digitally signed by AG
Date: 2019.05.02 15:59:59
-07'00'
Notes:
RoHS compliant
Function test: no open, no short circuit, no
intermittent
tel
fax
Description:
Connector, dc jack, 3.5x1.35xL16.5 mm, molding
style
3
2
1.541.323.3228
1.541.323.4202
Size:
Part number:
A
50-00057
Scale:
800
web
877.670.7118
tensility.com
2:1
Sheet 2 of 2
1
很抱歉,暂时无法提供与“50-00057”相匹配的价格&库存,您可以联系我们找货
免费人工找货