End of Life July 2020
CP High Volume
www.vishay.com
Vishay Dale
Wirewound/Metal Oxide Resistors, Commercial Power, Axial Lead
FEATURES
• High performance for low cost
• High power to size ratio
• Ceramic cases are available with circuit board
stand-offs (designated with a ...3 model ending)
• Special cement potting compound and ceramic
case provide high thermal conductivity in a
fireproof package
• Material categorization:
for definitions of compliance please see
www.vishay.com/doc?99912
STANDARD ELECTRICAL SPECIFICATIONS
POWER RATING
P40 °C
W
RESISTANCE RANGE
WIREWOUND (1)
RESISTANCE RANGE
METAL OXIDE (1)
TOLERANCE
±%
WEIGHT
(typical)
g
CP0002
2
0.1 to 100
101 to 30K
5, 10
2.0
CP0003
3
0.1 to 100
101 to 33K
5, 10
3.4
CP0005
5
0.1 to 100
101 to 50K
5, 10
3.6
CP0005...3
5
0.1 to 100
101 to 50K
5, 10
4.8
CP0007
7
0.1 to 100
101 to 50K
5, 10
5.0
GLOBAL
MODEL
CP0007...3
7
0.1 to 100
101 to 50K
5, 10
6.8
CP0010
10
0.1 to 100
101 to 50K
5, 10
9.5
CP0010...3
10
0.1 to 100
101 to 50K
5, 10
9.9
CP0015
15
0.1 to 100
101 to 50K
5, 10
16.8
CP0020
20
0.1 to 100
101 to 50K
5, 10
22.8
TECHNICAL SPECIFICATIONS
PARAMETER
UNIT
WIREWOUND CHARACTERISTICS
ppm/°C
± 400
± 400
-
5 x rated power for 5 s
5 x rated power for 5 s
Terminal Strength
lb
10 minimum
10 minimum
Operating Temperature Range
°C
-65 to +275
-65 to +225
Dielectric Withstanding Voltage
VAC
1000
1000
V
(P x R)1/2
(P x R)1/2
Temperature Coefficient
Short Time Overload
Maximum Working Voltage
METAL OXIDE CHARACTERISTICS
GLOBAL PART NUMBER INFORMATION
Global Part Numbering Example: CP000515R00JE663
C
P
0
0
0
5
1
5
R
0
0
J
E
6
6
3
GLOBAL MODEL
VALUE
TOLERANCE
PACKAGING
SPECIAL
(See Standard Electrical
Specifications Global
Model column for
options)
R = decimal
K = thousand
R1500 = 0.15
1K500 = 1500
J = ± 5.0 %
K = ± 10.0 %
E66 = lead (Pb)-free bulk pack
(Dash number)
(Up to 3 digits)
From 1 to 999
as applicable
Revision: 05-Feb-2020
Document Number: 30113
1
For technical questions, contact: ww2aresistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
End of Life July 2020
CP High Volume
www.vishay.com
Vishay Dale
DIMENSIONS in inches [millimeters]
CPxxxx
CPxxxx...3
LL
LD
L
W
LL
L
H
H
H1
0.125 [3.18]
typical
LD
W
DIMENSIONS in inches [millimeters]
GLOBAL MODEL
L (1)
± 0.060 [1.5]
W
± 0.040 [1.0]
H
± 0.040 [1.0]
H1
± 0.060 [1.5]
LD
± 0.002 [0.05]
LL
± 0.120 [3.0]
CP0002
0.71 [18]
0.276 [7]
0.276 [7]
-
0.0256 [0.65]
1.378 [35]
CP0003
0.87 [22]
0.315 [8]
0.315 [8]
-
0.031 [0.8]
1.378 [35]
CP0005
0.87 [22]
0.394 [10]
0.354 [9]
-
0.031 [0.8]
1.378 [35]
CP0005...3
0.87 [22]
0.394 [10]
0.354 [9]
0.413 [10.5]
0.031 [0.8]
1.378 [35]
CP0007
1.38 [35]
0.394 [10]
0.354 [9]
-
0.031 [0.8]
1.378 [35]
CP0007...3
1.38 [35]
0.394 [10]
0.354 [9]
0.472 [12]
0.031 [0.8]
1.378 [35]
CP0010
1.89 [48]
0.394 [10]
0.354 [9]
-
0.031 [0.8]
1.378 [35]
CP0010...3
1.89 [48]
0.394 [10]
0.354 [9]
0.472 [12]
0.031 [0.8]
1.378 [35]
CP0015
1.89 [48]
0.492 [12.5]
0.453 [11.5]
-
0.031 [0.8]
1.378 [35]
CP0020
2.36 [60]
0.551 [14]
0.531 [13.5]
-
0.031 [0.8]
1.378 [35]
Notes
(1) Potting compound may extend outside of ceramic case up to 0.060 [1.52] maximum per side
DERATING
Element: wirewound = copper-nickel alloy or nickel-chrome
alloy, depending on resistance value;
metal oxide = high temperature fired metal oxide film
Core: wirewound = ceramic
metal oxide = ceramic
Body: steatite ceramic case with inorganic potting
compound
RATED POWER IN %
MATERIAL SPECIFICATIONS
120
100
80
60
Wirewound
40
End Caps: tin plated steel
Terminals: tinned copper
20
Part Marking: DALE, model, wattage, value, tolerance, date
code
0
-55
Metal oxide
-25
25
75
40
125
175
275
225
AMBIENT TEMPERATURE IN °C
PERFORMANCE
TEST
CONDITIONS OF TEST
TEST LIMITS (EIA-344)
-55 °C to +275 °C (+225 °C for metal oxide), 5 cycles, 30 min dwell time
± (5.0 % + 0.05 ) R
Short Time Overload
5 x rated power for 5 s
± (4.0 % + 0.05 ) R
Dielectric Withstanding Voltage
1000 VRMS, for 1 min
± (2.0 % + 0.05 ) R
Low Temperature Storage
-65 °C, full rated working voltage for 45 min
± (3.0 % + 0.05 ) R
Humidity
75 °C, 90 % to 100 % RH, 240 h
± (5.0 % + 0.05 ) R
Load Life
1000 h at rated power, + 25 °C, 1.5 h “ON”, 0.5 h “OFF”
± (10.0 % + 0.05 ) R
Terminal Strength
5 pounds for 30 s; body twisted about axis, 3 x 360° rotations
± (2.0 % + 0.05 ) R
Resistance to Solder Heat
Terminal immersed 3.5 s in molten solder at 1/8" to 3/16" from body
± (4.0 % + 0.05 ) R
Thermal Shock
Revision: 05-Feb-2020
Document Number: 30113
2
For technical questions, contact: ww2aresistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
© 2021 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED
Revision: 01-Jan-2021
1
Document Number: 91000