DG9408/9409
New Product
Vishay Siliconix
Precision 8-Ch/Dual 4-Ch Low Voltage Analog Multiplexers
FEATURES
BENEFITS
APPLICATIONS
D 2.7-to 12-V Single Supply or "3- to "6-V
Dual Supply Operation
D Low On-Resistance—rON: 3.9 Typ.
D Fast Switching: tON — 42 ns, tOFF — 24 ns
D Break-Before-Make Guaranteed
D Low Leakage
D TTL, CMOS, LV Logic (3 V) Compatible
D 2000-V ESD Protection (HBM)
D
D
D
D
D
D
D
D
D
D
D
High Accuracy
Single and Dual Power Rail Capacity
Wide Operating Voltage Range
Simple Logic Interface
Data Acquisition Systems
Battery Operated Equipment
Portable Test Equipment
Sample and Hold Circuits
Communication Systems
SDSL, DSLAM
Audio and Video Signal Routing
DESCRIPTION
The DG9408/9409 uses BiCMOS wafer fabrication
technology that allows the DG9408/9409 to operate on single
and dual supplies. Single supply voltage ranges from 3- to
12-V while dual supply operation is recommended with "3 to
"6 V.
as determined by a 3-bit binary address (A0, A1, A2). The
DG9409 is a dual 4-channel differential analog multiplexer
designed to connect one of four differential inputs to a common
dual output as determined by its 2-bit binary address (A0, A1).
Break-before-make switching action to protect against
momentary crosstalk between adjacent channels.
The DG9408 is an 8-channel single-ended analog multiplexer
designed to connect one of eight inputs to a common output
FUNCTIONAL BLOCK DIAGRAM AND PIN CONFIGURATION
DG9408
DG9409
QFN16
QFN16
S1
A2
V-
D
S1b
Db
V-
Da
16
15
14
13
16
15
14
13
S2
1
12
S5
S2b
1
12
S1a
GND
2
11
S6
GND
2
11
S2a
S3
3
10
EN
S3b
3
10
EN
S4
4
9
S7
S4b
4
9
S3a
Decoder/Driver
Decoder/Driver
5
6
7
8
5
6
7
8
A0
V+
A1
S8
A0
V+
A1
S4a
Top View
Document Number: 71870
S-21060—Rev. A, 05-Aug-02
Top View
www.vishay.com
1
DG9408/9409
New Product
Vishay Siliconix
TRUTH TABLES AND ORDERING INFORMATION
TRUTH TABLE DG9408
TRUTH TABLE DG9409
A2
A1
A0
EN
On Switch
A1
A0
EN
On Switch
X
X
X
1
None
X
X
1
None
0
0
0
0
1
0
0
0
1
0
0
1
0
2
0
1
0
2
0
1
0
0
3
1
0
0
3
0
1
1
0
4
1
1
0
4
1
0
0
0
5
1
0
1
0
6
1
1
0
0
7
1
1
1
0
8
X = Don’t Care
For low and high voltage levels for VAX and VEN consult “Digital Control” Parameters for Specific V+ operation. See Specifications
Tables for:
Single Supply 12 V
Dual Supply V+ = 5 V, V- = -5 V
Single Supply 5 V
Single Supply 3 V
ORDERING INFORMATION DG9408
ORDERING INFORMATION DG9409
Temp Range
Package
Part Number
Temp Range
Package
Part Number
-40 to 85_C
16-Pin QFN (4x4 mm)
DG9408DN
-40 to 85_C
16- Pin QFN (4x4 mm)
DG9409DN
ABSOLUTE MAXIMUM RATINGS
Voltage Referenced to VV+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 V
GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Digital Inputsa, VS, VD . . . . . . . . . . . . . . . . . . . . . . . (V-) -0.3 V to (V+) +0.3 V
Current (Any Terminal Except S or D) . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 mA
Continuous Current, S or D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 mA
Peak Current, S or D
(Pulsed at 1 ms, 10% Duty Cycle Max) . . . . . . . . . . . . . . . . . . . . . . . . . 200 mA
Package Solder Reflow Conditionsd
16-Pin (4x4 mm) QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240_C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65 to 150_C
www.vishay.com
2
Power Dissipation (Package)b, (TA = 70_C)
16-Pin (4x4 mm) QFNc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1880 mW
Notes
a. Signals on SX, DX or INX exceeding V+ or V- will be clamped by internal
diodes. Limit forward diode current to maximum current ratings.
b. All leads soldered or welded to PC board.
c. Derate 23.5 mW/_C above 70_C.
d. Manual soldering with soldering iron is not recommended for leadless
components. The QFN is a leadless package. The end of the lead
terminal is exposed copper (not plated) as a result of the singulation
process in manufacturing. A solder fillet at the exposed copper lip cannot
be guaranteed and is not required to ensure adequate bottom side solder
interconnection.
Document Number: 71870
S-21060—Rev. A, 05-Aug-02
DG9408/9409
New Product
Vishay Siliconix
SPECIFICATIONS (SINGLE SUPPLY 12 V)
Test Conditions
Unless Otherwise Specified
Parameter
Symbol
V+ = 12 V, "10%, V- = 0 V
VA, VEN = 0.8 V or 2.4 Vf
Limits
-40 to 85_C
Tempb Minc
Typd
Maxc
Unit
12
V
Analog Switch
Analog Signal Rangee
On-Resistance
rON
rON Match Between Channelsg
On-Resistance
VANALOG
Flatnessi
Full
V+ = 10.8 V, VD = 2 V or 9 V, IS = 50 mA
Sequence Each Switch On
rON
rON
Flatness
V+ = 10.8 V, VD = 2 V or 9 V, IS = 50 mA
IS(off)
Switch Off Leakage Current
VEN = 2.4 V, VD = 11 V or 1 V, VS = 1 V or 11 V
ID(off)
Channel On Leakage Current
ID(on)
VEN = 0 V, VS = VD = 1 V or 11 V
0
Room
Full
4
7
7.5
Room
3.6
Room
8
Room
Full
-2
-15
2
15
Room
Full
-2
-15
2
15
Room
Full
-2
-15
2
15
2.4
nA
Digital Control
Logic High Input Voltage
VINH
Full
Logic Low Input Voltage
VINL
Full
Input Current
V
IIN
VAX = VEN = 2.4 V or 0.8 V
Full
tTRANS
VS1 = 8 V, VS8 = 0 V, (DG9408)
VS1b = 8 V, VS4b = 0 V, (DG9409)
See Figure 2
Room
Full
tBBM
VS(all) = VDA = 5 V
See Figure 4
Room
Full
0.8
-1
1
A
Dynamic Characteristics
Transition Time
Break-Before-Make Time
Enable Turn-On Time
tON(EN)
Enable Turn-Off Time
tOFF(EN)
VAX = 0 V, VS1 = 5 V (DG9408)
VAX = 0 V, VS1b = 5 V (DG9409)
See Figure 3
Q
CL = 1 nF, VGEN = 0 V, RGEN = 0
Charge Injectione
Off Isolatione, h
OIRR
Crosstalke
XTALK
Source Off Capacitancee
CS(off)
f = 1 MHz, VS = 0 V, VEN = 2.4 V
Drain Off Capacitancee
CD(off)
f = 1 MHz, VD = 0 V, VEN = 2.4 V
Drain On Capacitancee
CD(on)
f = 1 MHz, VD = 0 V, VEN = 0 V
42
2
24
ns
Room
Full
42
70
75
Room
Full
24
44
46
Room
29
Room
-80
Room
-85
DG9408
Room
21
DG9409
Room
23
DG9408
Room
211
DG9409
Room
112
DG9408
Room
238
DG9409
Room
137
f = 100 kHz, RL = 1 k
71
75
pC
dB
pF
Power Supplies
Power Supply Current
Document Number: 71870
S-21060—Rev. A, 05-Aug-02
I+
VEN = VA = 0 V or V+
Room
1.0
A
www.vishay.com
3
DG9408/9409
New Product
Vishay Siliconix
SPECIFICATIONS (DUAL SUPPLY V+ = 5 V, V− = −5 V)
Test Conditions
Unless Otherwise Specified
Parameter
Symbol
V+ = 5 V, V- = -5 V "10%
VA, VEN = 0.8 V or 2.0 Vf
Limits
-40 to 85_C
Tempb Minc
Typd
Maxc
Unit
5
V
Analog Switch
Analog Signal Rangee
On-Resistance
VANALOG
rON
rON Match Between Channelsg
On-Resistance Flatnessi
Full
V+ = 4.5 V, V- = -4.5 V, VD = "3.5 V, IS = 50 mA
Sequence Each Switch On
rON
rON
Flatness
V+ = 4.5 V, V- = -4.5 V, VD = "3.5 V, IS = 50 mA
IS(off)
Switch Off Leakage Current a
ID(off)
Channel On Leakage Current a
ID(on)
V+ = 5.5 V, V- = -5.5 V
VEN = 2.4 V, VD = "4.5 V, VS = #4.5 V
V+ = 5.5 V, V- = -5.5 V
VEN = 0 V, VD = "4.5 V, VS = #4.5 V
-5
Room
Full
5
8
8.5
Room
3.6
Room
8.2
Room
Full
-2
-15
2
15
Room
Full
-2
-15
2
15
Room
Full
-2
-15
2
15
2.0
nA
Digital Control
Logic High Input Voltage
VINH
Full
Logic Low Input Voltage
VINL
Full
Input Currenta
V
IIN
VAX = VEN = 2.0 V or 0.8 V
Full
tTRANS
VS1 = 3.5 V, VS8 = -3.5 V, (DG9408)
VS1b = 3.5 V, VS4b = -3.5 V, (DG9409)
See Figure 2
Room
Full
tBBM
VS(all) = VDA = 3.5 V
See Figure 4
Room
Full
0.8
-1
1
A
Dynamic Characteristics
Transition Timee
Break-Before-Make Timee
Enable Turn-On
Timee
tON(EN)
Enable Turn-Off
Timee
tOFF(EN)
Source Off Capacitancee
CS(off)
Drain Off Capacitancee
CD(off)
f = 1 MHz, VD = 0 V, VEN =2. 0 V
Drain On Capacitancee
CD(on)
f = 1 MHz, VD = 0 V, VEN = 0 V
1
89
94
16
ns
Room
Full
68
88
94
Room
Full
58
78
81
DG9408
Room
23
DG9409
Room
23
DG9408
Room
223
DG9409
Room
113
DG9408
Room
246
DG9409
Room
137
VAX = 0 V, VS1 = 3.5 V (DG9408)
VAX = 0 V, VS1b = 3.5 V (DG9409)
See Figure 3
f = 1 MHz, VS = 0 V, VEN = 2.0 V
68
pF
Power Supplies
I+
Power Supply Current
www.vishay.com
4
I-
Room
VEN = VA = 0 V or V+
Room
1.0
-1.0
A
Document Number: 71870
S-21060—Rev. A, 05-Aug-02
DG9408/9409
New Product
Vishay Siliconix
SPECIFICATIONS (SINGLE SUPPLY 5 V)
Test Conditions
Unless Otherwise Specified
Parameter
Symbol
V+ = 5 V, "10%, V- = 0 V
VA, VEN = 0.8 V or 2.0 Vf
Limits
-40 to 85_C
Tempb Minc
Typd
Maxc
Unit
5
V
Analog Switch
Analog Signal Rangee
On-Resistance
VANALOG
rON
rON Match Between Channelsg
On-Resistance Flatnessi
Full
V+ = 4.5 V, VD or VS = 1 V or 3.5 V, IS = 50 mA
rON
rON
Flatness
V+ = 4.5 V, VD = 1 V or 3.5 V, IS = 50 mA
IS(off)
Switch Off Leakage
Current a
ID(off)
Channel On Leakage Currenta
ID(on)
V+ = 5.5 V
VS = 1 V or 4 V, VD = 4 V or 1 V
V+ = 5.5 V
VD = VS = 1 V or 4 V, Sequence Each Switch On
0
Room
Full
7
10.5
11
Room
3.6
Room
9
Room
Full
-2
-15
2
15
Room
Full
-2
-15
2
15
Room
Full
-2
-15
2
15
Full
2.0
nA
Digital Control
Logic High Input Voltage
VINH
Logic Low Input Voltage
VINL
Input Currenta
V+ = 5 V
V
Full
IIN
VAX = VEN = 2.0 V or 0.8 V
Full
Transition Timee
tTRANS
VS1 = 3.5 V, VS8 = 0 V, (DG9408)
VS1b = 3.5 V, VS4b = 0 V, (DG9409)
See Figure 2
Room
Full
Break-Before-Make Timee
tOPEN
VS(all) = VDA = 3.5 V
See Figure 4
Room
Full
0.8
-1
1
A
Dynamic Characteristics
Room
Full
38
57
61
Room
20
Room
-81
Room
-85
DG9408
Room
22
DG9409
Room
24
DG9408
Room
223
DG9409
Room
113
DG9408
Room
244
DG9409
Room
143
Enable Turn-Off
Timee
tOFF(EN)
VAX = 0 V, VS1 = 3.5 V (DG9408)
VAX = 0 V, VS1b = 3.5 V (DG9409)
See Figure 3
Q
CL = 1 nF, RGEN = 0 , VGEN = 0 V
OIRR
Crosstalke
XTALK
Source Off Capacitancee
CS(off)
RL = 1 k
f = 100 kHz
f = 1 MHz, VS = 0 V, VEN = 0 V
Drain Off Capacitancee
CD(off)
f = 1 MHz, VD = 0 V, VEN = 2.0 V
Drain On Capacitancee
CD(on)
f = 1 MHz, VD = 0 V, VEN = 0 V
ns
94
104
tON(EN)
Off
29
74
Enable Turn-On
Isolatione, h
2
94
104
Room
Full
Timee
Charge Injectione
73
pC
dB
pF
Power Supplies
Power Supply Current
Document Number: 71870
S-21060—Rev. A, 05-Aug-02
I+
VEN = VA = 0 V or V+
Room
1.0
A
www.vishay.com
5
DG9408/9409
New Product
Vishay Siliconix
SPECIFICATIONS (SINGLE SUPPLY 3 V)
Test Conditions
Unless Otherwise Specified
Parameter
Symbol
V+ = 3 V, "10%, V- = 0 V
VEN = 0.4 V or 1.8 Vf
Limits
-40 to 85_C
Tempb Minc
Typd
Maxc
Unit
3
V
12
25.5
26.5
Analog Switch
Analog Signal Rangee
On-Resistance
rON Match Between Channelsg
On-Resistance
Flatnessi
VANALOG
Full
rON
Room
Full
V+ = 2.7 V, VD = 0.5 or 2.2 V, IS = 5 mA
rON
rON
Flatness
V+ = "2.7 V, VD = 0.5 V or 2.2 V, IS = 5 mA
IS(off)
Switch Off Leakage Current a
ID(off)
Channel On Leakage Currenta
ID(on)
V+ = 3.3 V
VS = 2 or 1 V, VD = 1 or 2 V
V+ = 3.3 V
VD = VS = 1 or 2 V, Sequence Each Switch On
0
Room
3.6
Room
13
Room
Full
-2
-15
2
15
Room
Full
-2
-15
2
15
Room
Full
-2
-15
2
15
1.8
nA
Digital Control
Logic High Input Voltage
VINH
Full
Logic Low Input Voltage
VINL
Full
Input Current a
IIN
VAX = VEN = 1.8 V or 0.4 V
Full
tTRANS
VS1 = 1.5 V, VS8 = 0 V, (DG9408)
VS1b = 1.5 V, VS4b = 0 V, (DG9409)
See Figure 2
Room
Full
tBBM
VS(all) = VDA = 1.5 V
See Figure 4
Room
Full
0.4
-1
1
V
A
Dynamic Characteristics
Transition Time
Break-Before-Make Time
Enable Turn-On Time
tON(EN)
Enable Turn-Off Time
tOFF(EN)
VAX = 0 V, VS1 = 1.5 V (DG9408)
VAX = 0 V, VS1b = 1.5 V (DG9409)
See Figure 3
Q
CL = 1 nF, RGEN = 0 , VGEN = 0 V
Charge Injectione
Off Isolatione, h
OIRR
Crosstalke
XTALK
Source Off Capacitancee
CS(off)
f = 1 MHz, VS = 0 V, VEN = 1.8 V
Drain Off Capacitancee
CD(off)
f = 1 MHz, VD = 0 V, VEN = 1.8 V
Drain On Capacitancee
CD(on)
f = 1 MHz, VD = 0 V, VEN = 0 V
140
2
63
ns
Room
Full
140
162
178
Room
Full
76
97
104
Room
7
Room
-81
Room
-85
DG9408
Room
23
DG9409
Room
25
DG9408
Room
230
DG9409
Room
120
DG9408
Room
256
DG9409
Room
147
f = 100 kHz, RL = 1 k
165
182
pC
dB
pF
Power Supplies
Power Supply Current
I+
VEN = VA = 0 V or V+
Room
1.0
A
Notes
a. Leakage parameters are guaranteed by worst case test condition and not subject to production test.
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
d. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
e. Guaranteed by design, not subject to production test.
f.
VIN = input voltage to perform proper function.
g. rDON = rDON Max - rDON Min.
h. Worst case isolation occurs on Channel 4 do to proximity to the drain pin.
i.
rDON flatness is measured as the difference between the minimum and maximum measured values across a defined Analog signal.
www.vishay.com
6
Document Number: 71870
S-21060—Rev. A, 05-Aug-02
DG9408/9409
New Product
Vishay Siliconix
TYPICAL CHARACTERISTICS (25_C UNLESS NOTED)
1
rON vs. VCOM and Single Supply Voltage
rON vs. Analog Voltage and Temperature
16
16
T = 25_C
14
12
r ON - On-Resistance ( )
r ON - On-Resistance ( )
14
V+ = 3.0 V
IS = 5 mA
10
8
V+ = 5.0 V
IS = 50 mA
6
V+ = 12.0 V
IS = 50 mA
4
2
12
A
10
V+ = 5.0 V
IS = 50 mA
B
C
8
A
B
6
V+ = 12.0 V
IS = 50 mA
A
C
4
B
C
2
0
0
0
3
6
9
12
0
2
4
VCOM — Analog Voltage (V)
V" = "5 V
IS = 50 mA
12
VAX, VEN = 0 V
1000
8
6
B
10
Supply Current vs. Temperature
A = 85_C
B = 25_C
C = -40_C
A
8
10000
I+ - Supply Current (pA)
10
6
VCOM — Analog Voltage (V)
rON vs. Analog Voltage and Temperature
12
r ON - On-Resistance ( )
A = 85_C
B = 25_C
C = -40_C
V+ = 3.0 V
IS = 5 mA
C
4
V+ = 12 V
V- = 0 V
100
V+ = 5 V
V- = -5 V
10
2
0
-5
-3
-1
1
3
1
-60
5
-40
-20
VCOM — Analog Voltage (V)
20
40
60
80
100
Temperature (_C)
Leakage Current vs. Analog Voltage
Leakage Current vs. Analog Voltage
20
100
INO(off)/INC(off)
INO(off)/INC(off)
0
Leakage Current (pA)
0
Leakage Current (pA)
0
-100
ICOM(off)
-200
ICOM(on)
-300
-20
ICOM(off)
-40
ICOM(on)
-60
-80
V+ = 12 V
V- = 0 V
-400
V+ = 5 V
V- = -5 V
-100
-500
-120
0
2
4
6
8
10
VCOM, VNO, VNC - Analog Voltage
Document Number: 71870
S-21060—Rev. A, 05-Aug-02
12
-5
-3
-1
1
3
5
VCOM, VNO, VNC - Analog Voltage
www.vishay.com
7
DG9408/9409
New Product
Vishay Siliconix
TYPICAL CHARACTERISTICS (25_C UNLESS NOTED)
Switching Time vs. Temperature
and Single Supply Voltage
Transition Time vs. Temperature
and Single Supply Voltage
180
160
tTRANS- V+ = 3 V
tON V+ = 3 V
140
150
tTRANS+ V+ = 3 V
Transistion Time (ns)
120
100
tOFF V+ = 3 V
80
tON V+ = 5 V
60
tON V+ = 12 V
40
120
tTRANS- V+ = 5 V
90
tTRANS+ V+ = 5 V
60
tTRANS- V+ = 12 V
tTRANS+ V+ = 12 V
tOFF V+ = 5 V
30
20
tOFF V+ = 12 V
0
-60
-40
-20
0
20
40
60
80
0
-60
100
-40
-20
0
Temperature (_C)
Leakage Current vs. Temperature
40
60
80
100
Switching Threshold vs. Supply Voltage
10000
3.0
V T - Switching Threshold (V)
V+ = 5 V
V- = -5 V
1000
Leakage Current (pA)
20
Temperature (_C)
INO(off), INC(off)
100
ICOM(on)
10
2.5
2.0
1.5
1.0
0.5
ICOM(off)
1
0.0
-60
-40
-20
0
20
40
60
80
2
100
4
6
Insertion Loss, Off Isolation and Crosstalk
vs. Frequency (DG9408)
0
Insertion Loss
Loss, OIRR, XTALK (dB)
Loss, OIRR, XTALK (dB)
-10
-20
-30
OIRR
-40
-50
-60
Crosstalk
V+ = 12 V
V- = 0 V
RL = 50
-70
14
-80
Insertion Loss
-10
-20
-30
-40
OIRR
-50
-60
Crosstalk
V+ = 12 V
V- = 0 V
RL = 50
-70
-80
-90
-90
1M
10 M
Frequency (Hz)
8
12
10
0
www.vishay.com
10
Insertion Loss, Off Isolation and Crosstalk
vs. Frequency (DG9404)
10
100 K
8
V+ - Supply Voltage (V)
Temperature (_C)
100 M
1G
100 K
1M
10 M
100 M
1G
Frequency (Hz)
Document Number: 71870
S-21060—Rev. A, 05-Aug-02
DG9408/9409
New Product
Vishay Siliconix
TYPICAL CHARACTERISTICS (25_C UNLESS NOTED)
1
Supply Current vs. Input Switching Frequency
100 m
V+ = 5 V
V- = -5 V
I+ - Supply Current (A)
10 m
1m
100
10
1
100 n
10 n
1n
10
100
1K
10 K
100 K
1M
10 M
Input Switching Frequency (Hz)
SCHEMATIC DIAGRAM (TYPICAL CHANNEL)
V+
D
A0
V+
Level
Shift
AX
Decode/
Drive
V-
S1
V+
EN
Sn
GND
V-
FIGURE 1.
Document Number: 71870
S-21060—Rev. A, 05-Aug-02
www.vishay.com
9
DG9408/9409
New Product
Vishay Siliconix
TEST CIRCUITS
V+
V+
A2
S1
A1
50
Logic
Input
S2 - S7
A0
DG9408
S8
VS8
VAX
GND
3V
50%
0V
VO
D
EN
tr