RS1A, RS1B, RS1D, RS1G, RS1J, RS1K
www.vishay.com
Vishay General Semiconductor
Surface Mount Fast Switching Rectifier
FEATURES
• Low profile package
• Ideal for automated placement
• Glass passivated pellet chip junction
• Fast switching for high efficiency
• High forward surge capability
• Meets MSL level 1, per J-STD-020, LF maximum peak
of 260 °C
SMA (DO-214AC)
DESIGN SUPPORT TOOLS
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
click logo to get started
TYPICAL APPLICATIONS
For use in fast switching rectification of power supply,
inverters, converters, and freewheeling diodes for
consumer, and telecommunication.
Models
Available
PRIMARY CHARACTERISTICS
MECHANICAL DATA
IF(AV)
1.0 A
VRRM
50 V, 100 V, 200 V, 400 V, 600 V, 800 V
IFSM
30 A
trr
150 ns, 250 ns, 500 ns
VF
1.3 V
TJ max.
150 °C
Package
SMA (DO-214AC)
Circuit configuration
Single
Case: SMA (DO-214AC)
Molding compound meets UL 94 V-0 flammability rating
Base P/N-M3 - halogen-free, RoHS-compliant, and
commercial grade
Terminals: matte tin plated leads, solderable
J-STD-002 and JESD 22-B102
M3 suffix meets JESD 201 class 2 whisker test
per
Polarity: color band denotes cathode end
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
Device marking code
RS1A
RS1B
RS1D
RS1G
RS1J
RS1K
RA
RB
RD
RG
RJ
RK
UNIT
Maximum repetitive peak reverse voltage
VRRM
50
100
200
400
600
800
V
Maximum RMS voltage
VRMS
35
70
140
280
420
500
V
Maximum DC blocking voltage
VDC
50
100
200
400
600
800
Maximum average forward rectified current at TL = 90 °C
IF(AV)
1.0
A
Peak forward surge current 8.3 ms single half sine-wave
superimposed on rated load
IFSM
30
A
TJ, TSTG
-55 to +150
°C
Operating junction and storage temperature range
V
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
TEST CONDITIONS
Maximum instantaneous
forward voltage
1.0 A
Maximum DC reverse current at
rated DC blocking voltage
SYMBOL
RS1A
RS1B
RS1D
VF
TA = 25 °C
TA = 125 °C
RS1G
RS1J
RS1K
1.3
V
5.0
IR
μA
50
Maximum reverse recovery time
IF = 0.5 A, IR = 1.0 A,
Irr = 0.25 A
trr
150
Typical junction capacitance
4.0 V, 1 MHz
CJ
10
UNIT
250
500
7.0
ns
pF
Revision: 10-Aug-2018
Document Number: 89402
1
For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
RS1A, RS1B, RS1D, RS1G, RS1J, RS1K
www.vishay.com
Vishay General Semiconductor
THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
RJA
Typical thermal resistance
RS1A
RS1B
RS1D
(1)
RS1G
RS1J
RS1K
105
RJL (1)
UNIT
°C/W
32
Note
(1) Thermal resistance from junction-to-ambient and from junction-to-lead mounted on PCB with 0.2" x 0.2" (5.0 mm x 5.0 mm) copper pad
areas
ORDERING INFORMATION (Example)
UNIT WEIGHT (g)
PREFERRED PACKAGE CODE
BASE QUANTITY
DELIVERY MODE
RS1J-M3/61T
PREFERRED P/N
0.064
61T
1800
7" diameter plastic tape and reel
RS1J-M3/5AT
0.064
5AT
7500
13" diameter plastic tape and reel
RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted)
100
Instantaneous Forward Current (A)
Average Forward Rectified Current (A)
1.2
Resistive or Inductive Load
1.0
0.8
0.6
0.4
P.C.B. Mounted on
0.2" x 0.2" (5.0 mm x 5.0 mm)
Copper Pad Areas
0.2
0
20
40
60
80
100
120
140
160
Peak Forward Surge Current (A)
1
TJ = 25 °C
0.1
TJ = -40 °C
0.01
0.6
0.8
1.0
1.2
1.4
1.6
1.8
Lead Temperature (°C)
Instantaneous Forward Voltage (V)
Fig. 1 - Forward Current Derating Curve
Fig. 3 - Typical Instantaneous Forward Characteristics
50
TL = 90 °C
8.3 ms Single Half Sine-Wave
40
30
20
10
0
1
TJ = 125 °C
0.4
180
10
100
Number of Cycles at 60 Hz
Fig. 2 - Maximum Non-Repetitive Peak Forward Surge Current
Instantaneous Reverse Current (ƶA)
0
10
1000
100
TJ = 125 °C
10
TJ = 100 °C
1
0.1
TJ = 25 °C
0.01
TJ = -40 °C
0.001
10
20
30
40
50
60
70
80
90
100
Percent of Rated Peak Reverse Voltage (%)
Fig. 4 - Typical Reverse Characteristics
Revision: 10-Aug-2018
Document Number: 89402
2
For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
RS1A, RS1B, RS1D, RS1G, RS1J, RS1K
www.vishay.com
Vishay General Semiconductor
100
TJ = 25 °C
f = 1.0 MHz
Vsig = 50 mVp-p
Transient Thermal Impedance (°C/W)
Junction Capacitance (pF)
100
RS1A thru RS1G
10
RS1J thru RS1K
10
Mounted on 0.2" x 0.2" (5 mm x 5 mm)
Copper Pad Area
1
0.01
1
1
10
100
0.1
1
10
Reverse Voltage (V)
t - Pulse Duration (s)
Fig. 5 - Typical Junction Capacitance
Fig. 6 - Typical Transient Thermal Impedance
PACKAGE OUTLINE DIMENSIONS in inches (millimeters)
SMA (DO-214AC)
Cathode Band
Mounting Pad Layout
0.110 (2.79)
0.100 (2.54)
0.065 (1.65)
0.049 (1.25)
0.177 (4.50)
0.157 (3.99)
0.012 (0.305)
0.006 (0.152)
0.060 (1.52)
MIN.
0.208 (5.28)
REF.
0.090 (2.29)
0.078 (1.98)
0.060 (1.52)
0.030 (0.76)
0.074 (1.88)
MAX.
0.066 (1.68)
MIN.
0.008 (0.203)
0 (0)
0.208 (5.28)
0.194 (4.93)
Revision: 10-Aug-2018
Document Number: 89402
3
For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product
with the properties described in the product specification is suitable for use in a particular application. Parameters provided in
datasheets and / or specifications may vary in different applications and performance may vary over time. All operating
parameters, including typical parameters, must be validated for each customer application by the customer's technical experts.
Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited
to the warranty expressed therein.
Hyperlinks included in this datasheet may direct users to third-party websites. These links are provided as a convenience and
for informational purposes only. Inclusion of these hyperlinks does not constitute an endorsement or an approval by Vishay of
any of the products, services or opinions of the corporation, organization or individual associated with the third-party website.
Vishay disclaims any and all liability and bears no responsibility for the accuracy, legality or content of the third-party website
or for that of subsequent links.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
© 2022 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED
Revision: 01-Jan-2022
1
Document Number: 91000