Option Information
www.vishay.com
Vishay Semiconductors
Option Information
Optocoupler lead-bend configurations are available as
options. In addition, partial discharge testing as per
VDE / IEC is also available as an option.
The options are:
Option 1 VDE option
Option 6 400 mil (10.16 mm) lead spread DIP configuration
See the order information section in the data sheet to
determine if and which options are available to a specific
product. Contact the Vishay sales office for other option
configurations.
Option 7 Surface mount, gull wing DIP configuration with
standoff
Option 8 Surface mount, gull wing DIP configuration with
increased clearance
Option 9 Surface mount, gull wing DIP configuration
ORDERING OPTIONS
A specific option or combination of options can be ordered
by add the options definition field following the base part
S
F
Prefix
H
6
1
5
A
Base Part Number
-
3
X
CTR Ranges
1 = 40 % to 80 %
2 = 63 % to 125 %
3 = 100 % to 200 %
4 = 160 % to 320 %
5 = 250 % to 500 %
or 50 % to 150 % (1)
6 = 100 % to 300 % (1)
7 = 80 % to 160 % (1)
8 = 130 % to 260 % (1)
9 = 200 % to 400 % (1)
BRT
Il
ILD
ILQ
SFH6
VO
Examples:
CNY17F-2X017T
4N35-X016
SFH615-3X001
VO615A-9X007T
number and CTR range (if applicable) as presented in the
following example:
0
0
Options Definition
9
T
Tape and
Reel Option
Option 1 Optocouplers for saf e electr ical
Insulation per DIN VDE 0884
Option 6 Optocouplers with 10.16 mm (0.4")
through hole lead spread
Option 7 Optocouplers with SMD lead form bend,
0.9 mm maximum standoff height
Option 8 Optocouplers with 10.16 mm (0.4") SMD
lead form bend
Option 9 Optocouplers with SMD lead form bend,
0.25 mm maximum standoff height
Option 1 may be combined with the other
lead forming options.
Option T may only be combined with
Options 7, 8, and 9
Note
(1) Used on selected products, consult data sheet for details
This field is always 4 characters long and commences with
the character X. In the case of surface mounted products in
tape and reel format, the tape and reel option character “T”
will follow this field.
18482
The possible combinations for these fields (1) are:
X001, X006, X007, X008, X009, X001T (2), X007T, X008T,
X009T, X016, X017, X018, X019, X017T, X018T, X019T
Notes
(1) Not all options are available for all product types.
(2) The X001T option is only available on products that are available on the following SMD products SFH6106, SFH6156, SFH6186, SFH6206,
and SFH6286 series, e.g. SFH6106-3X001T .
OPTION 1
OPTOCOUPLERS FOR SAFE ELECTRICAL INSULATION PER DIN EN 60747-5-5 (VDE 0884) (1)
The optocoupler listed are suitable for safe electrical
insulation only within the safety maximum ratings.
Compliance with the safety maximum ratings must be
ensured by protective circuits.
The partial discharge measurement ensures that no partial
discharge occurs during operation at maximum permissible
operating insulation voltage (VIORM). Permanent partial
discharge affects the insulating materials and can result in a
high voltage breakdown.
Rev. 2.0, 24-Aug-15
It is recommended that tests with the insulation test voltage
(VISOL) should not be made, otherwise partial discharge may
occur impairing the insulation characteristics. Thus partial
discharges also may occur at the maximum permissible
operating insulation voltage.
The insulation test per DIN EN 60747-5-5 (VDE 0884) is
carried out after all the other tests
Document Number: 83713
1
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Option Information
www.vishay.com
Vishay Semiconductors
V INITIAL
V
V
V Pr
0.1 to 1 kV/µs
V Pr
V IORM
V IORM
t
t
60 s
1s
t p =10 s
0.1 s
1.0 s
tp = 1.0 s
0.1 s
1.2 s
12 s
tp: measuring time for par tial dischage
tp: measuring time for partial dischage
Procedure a.
Type and sampling tests, destructive tests
Procedure b.
Routine tests, non-destructive tests
17928-1
Fig. 1 - Time Voltage Diagram per DIN EN 60747-5-5
DESCRIPTION
SYMBOL
SYSTEM 1
DIP4
DIP8
UNIT
DIP16
SFH610A-..
ILCT6
ILQ1/2/5/74
SFH615A-..
ILD1/2/5/74
ILQ30/31/55
SFH615AA-..
ILD30/31/55
ILQ32
SFH615AGB-..
ILD32
ILQ66-..
SFH615AGR-..
ILD66-..
ILQ615-..
SFH617A-..
ILD250/1/2
ILQ620-..
SFH618A-..
ILD255
ILQ620GB-..
SFH620A-..
ILD621GB-..
ILQ621-..
SFH620AA-..
ILD621-..
ILQ621GB-..
SFH620AGB-..
ILD621GB-..
SFH628A-..
ILD755-..
SFH6106-..
ILD766-..
SFH6116-..
MCT6
SFH6156-..
SFH6186-..
SFH6206-..
SFH6286-..
Installation category (DIN VDE 0110)
For rated line voltages 300 VRMS
I to IV
For rated line voltages 600 VRMS
I to IV
For rated line voltages 1000 VRMS
IEC climatic category (DIN IEC 60068 Part 1/9.80)
55/100/21
Pollution degree (DIN VDE 0110 Part 1/1.89)
Maximum operation insulating
voltage (1)
Test voltage input/output, procedure b (1) VPr = 1.875 x VIORM,
routine 100 % test, tp = 1 s, partial discharge < 5 pC
a (1) VPr
Test voltage input/output, procedure
= 1.6 x VIORM,
type and sampling test tp = 60 s, partial discharge < 5 pC
Maximum permissible overvoltage (transient overvoltage)
Partial discharge test voltage (1)
2
VIORM
890
Vpeak
VPr
1669
Vpeak
VPr
1424
Vpeak
VIOTM
10 000
Vpeak
VINITIAL
8000
Vpeak
Safety maximum ratings (maximum permissible ratings
in case of a fault, also refer to d diagram)
Package temperature
Current (input current IF, PSi = 0, TA = 25 °C)
Derating with higher ambient temperature
Power (output or total power dissipation, TA = 25 °C)
Derating with higher ambient temperature
Tsi
Isi
ISi
PSi
PSi
175
275
°C
mA
-1.83
400
-2.67
mA/K
mW
mW/K
Insulation resistance at TSi VI/O = 500 V
RIS
> 109
W
Rev. 2.0, 24-Aug-15
Document Number: 83713
2
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Option Information
www.vishay.com
DESCRIPTION
Vishay Semiconductors
SYMBOL
SYSTEM 2
UNIT
4N25/26/27/28
IL250
MCT5210
4N35/36/37/38/39
IL251
MCT5211
4N32/33
IL252
SFH600-..
CNY17-..
IL255-..
SFH601-..
CNY17F-..
IL400
SFH608-..
H11A-..
IL755-..
SFH640-..
H11AA1-..
IL755B-..
MOC8050
H11B-..
IL766-..
IL56B-..
H11B1-..
IL766B-..
MOC8021
H11C-..
MCA230/231
MOC8112
MOC8102/03/04/05
H11D-..
MCA255
IL1/2/5/74
MCT2/2E
VO610A...
IL2B-..
MCT270/271
VO615A...
IL30/31/55
MCT272
VO617A...
IL55B-..
MCT273/274
VO618A...
IL66-..
MCT275
VO615C...
IL66B-..
MCT276/277
VO617C...
IL201/202/203
Installation category (DIN VDE 0110)
For rated line voltages 300 VRMS
I to IV
For rated line voltages 600 VRMS
I to IV
For rated line voltages 1000 VRMS
IEC climatic category (DIN IEC 60068 Part 1/9.80)
55/100/21
Pollution degree (DIN VDE 0110 Part 1/1.89)
2
Maximum operation insulating voltage (1)
VIORM
890
Vpeak
Test voltage input/output, procedure b (1)
VPr = 1.875 x VIORM, routine 100 % test,
tp = 1 s, partial discharge < 5 pC
VPr
1669
Vpeak
Test voltage input/output, procedure a (1)
VPr = 1.6 x VIORM, type and sampling test tp = 60 s,
partial discharge < 5 pC
VPr
1424
Vpeak
Maximum permissible overvoltage (transient overvoltage)
VIOTM
8000
Vpeak
Partial discharge test voltage (1)
VINITIAL
8000
Vpeak
Safety maximum ratings
(maximum permissible ratings in case of a fault,
also refer to diagram)
Package temperature
Current
(input current IF, PSi = 0, TA = 25 °C)
Derating with higher ambient temperature
Power (output or total power dissipation, TA = 25 °C)
Derating with higher ambient temperature
Tsi
Isi
175
400
°C
mA
DISi
PSi
PSi
-2.67
700
-4.67
mA/K
mW
mW/K
Insulation resistance at TSi VI/O = 500 V
RIS
> 10 9
W
Rev. 2.0, 24-Aug-15
Document Number: 83713
3
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Option Information
www.vishay.com
DESCRIPTION
Vishay Semiconductors
SYMBOL
SYSTEM 4 (2)
SYSTEM 5
IL410
6N135
IL300
IL420
6N136
IL300E
IL4116
SFH6135
IL300F
IL4117
SFH6136
IL300EF
IL4118
6N138
IL300DEFG
IL4216
SFH6138
IL4217
SFH6139
IL4218
6N139
SYSTEM 7
UNIT
SFH6345
6N137...
VO2601...
VO2611...
VO2630...
VO2631...
VO4661...
Installation category (DIN VDE 0110)
For rated line voltages 300 VRMS
I to IV
I to IV
I to IV
For rated line voltages 600 VRMS
I to III
I to IV
I to IV
55/100/21
55/100/21
55/100/21
2
2
2
VIORM
890
890
890
Vpeak
Test voltage input/output, procedure
VPr = 1.875 x VIORM, routine 100 % test, tp = 1 s,
partial discharge < 5 pC
VPr
1669
1669
1669
Vpeak
Test voltage input/output, procedure a (1)
VPr = 1.6 x VIORM, type and sampling Test tp = 60 s,
partial discharge < 5 pC
VPr
1424
1424
1424
Vpeak
VIOTM
8000
8000
8000
Vpeak
VINITIAL
8000
8000
8000
Vpeak
For rated line voltages 1000 VRMS
IEC climatic category (DIN IEC 60068 Part 1/9.80)
Pollution degree (DIN VDE 0110 Part 1/1.89)
Maximum operation insulating voltage (1)
b (1)
Maximum permissible overvoltage (transient
overvoltage)
Partial discharge test voltage (1)
Safety maximum ratings
(maximum permissible ratings in case of a fault,
also refer to diagram)
Package temperature
Current
(input current IF, PSi = 0, TA = 25 °C)
Derating with higher ambient temperature
Power (output or total power dissipation, TA = 25 °C)
Derating with higher ambient temperature
Tsi
Isi
175
250
175
300
165
235
°C
mA
DISi
PSi
PSi
-1.65
500
-3.33
-2
500
-3.33
-1.57
465
-3.1
mA/K
mW
mW/K
Insulation resistance at TSi VI/O = 500 V
RIS
> 109
> 109
> 109
W
Notes
All voltages referred to are peak values except otherwise specified.
(1) See time-test voltage diagram
(2) In preparation
Testing input / output voltage requires all input pins and all output pins to be shorted
Option 1: Tested per DIN EN 60747-5-2 (VDE 0884) / DIN EN 60747-5-5 (pending)
Option 6: Wide lead spacing (10.16 mm creepage / clearance distances > 8 mm)
Option 7: Surface mount leads (creepage / clearance distances > 8 mm)
Option 8: Surface mount leads
Option 9: Surface mount leads
See CECC 00802, edition 1, for soldering conditions for SMT devices (option 7 and 9).
“-..” means dash selections
Rev. 2.0, 24-Aug-15
Document Number: 83713
4
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Option Information
www.vishay.com
Vishay Semiconductors
OPTION 6
DIP OPTOCOUPLERS WITH 0.4" (10.16 mm) LEAD SPREAD
The leads of the optocouplers are bent according to a
spacing of 0.4" (10.16 mm). Dimensions deviating from the
standard type are:
Lead spacing
10.16 mm (0.4")
Creepage distance > 8 mm
Clearance
> 8 mm
VRMS or DC
7.62 typ.
3.5 ± 0.3
This version additionally complies with the following
standards:
0.1 min.
• IEC 60950 DIN VDE 0805/05 90 (System 2 and 3 only)
Reinforced insulation up to an operating voltage of 400
2.55 ± 0.25
10.16 typ.
20802-5
Clearance-creepage distance = 8 mm min.
See standard version for pin configuration
OPTION 7
LEAD BENDS FOR SURFACE MOUNT OPTOCOUPLERS
These optocouplers are suitable for surface mounting.
Dimensions deviating from the standard type are:
Creepage distance > 8 mm
Clearance distance > 8 mm
DIP 6
7.62 typ.
0.7 min.
This version additionally complies with the following
standards:
4.6
4.1
8 min.
• IEC 60950 DIN VDE 0805/05 90 (system 2 and 3 only)
Reinforced insulation up to an operating voltage of
400 VRMS or DC
8.4 min.
10.3 max.
During the soldering process, the package should not be
wetted with tin-lead solder to prevent the impairment of the
isolation features. Apart from iron soldering, only reflow
soldering methods (vapor phase, infrared and hot gas) are
permissible.
7.62 typ.
3.81
3.30
DIP 4, DIP 8, DIP 16
0.90
0.51
Permissible soldering conditions for SMD bending options:
please see reflow soldering profile.
8.41 min.
The soldering process may be repeated two times at the
most. Attention must be paid to the cooling down of the
device to 25 °C between the soldering processes.
10.3 max.
12.30 ± 0.30
Wide Body, Option 7
9.00 ± 0.15
0.25 ± 0.05
0.75 ± 0.25
11.0 max.
10.16 min.
1.00 ± 0.15
Lead
coplanarity:
max. 0.10
Clearance and creepage distances must be considered for
the solder pad design.
Clearance-creepage distance = 8 mm min.
See standard version for pin configuration.
Rev. 2.0, 24-Aug-15
Document Number: 83713
5
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Option Information
www.vishay.com
Vishay Semiconductors
OPTION 8
LEAD BENDS FOR SURFACE MOUNT OPTOCOUPLERS
These optocouplers are suitable for surface mounting.
Dimensions deviating from the standard type are:
7.62 typ.
Creepage distance > 8 mm
Clearance distance > 8 mm
DIP 6
0.50
0.00
This version additionally complies with the following
standards:
• IEC 60950 DIN VDE 0805/05 90 (system 2 and 3 only)
Reinforced insulation up to an operating voltage of
400 VRMS or DC
3.81
3.30
9.27 min.
12 max.
During the soldering process, the package should not be
wetted with tin-lead solder to prevent the impairment of the
isolation features. Apart from iron soldering, only reflow
soldering methods (vapor phase, infrared and hot gas) are
permissible.
7.62 typ.
Permissible soldering conditions for SMD bending options:
please see reflow soldering profile.
0.50
0.00
The soldering process may be repeated two times at the
most. Attention must be paid to the cooling down of the
device to 25 °C between the soldering processes.
DIP 4
3.81
3.30
9.27 min.
12 max.
17932-1
Clearance and creepage distances must be considered for
the solder pad design.
Clearance-creepage distance = 8 mm min.
See standard version for pin configuration.
OPTION 9
LEAD BENDS FOR SURFACE MOUNT OPTOCOUPLERS
During the soldering process, the package should not be
wetted with tin-lead solder to prevent the impairment of the
isolation features. Apart from iron soldering, only reflow
soldering methods (vapor phase, infrared and hot gas) are
permissible.
Permissible soldering conditions for SMD bending options:
please see reflow soldering profile.
The soldering process may be repeated two times at the
most. Attention must be paid to the cooling down of the
device to 25 °C between the soldering processes.
9.53
10.03
7.62 ref.
0.102
0.249
0.30 typ.
0.51
1.02
15° max.
17933-1
Rev. 2.0, 24-Aug-15
Document Number: 83713
6
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Option Information
www.vishay.com
Vishay Semiconductors
MARKINGS
Product marking is defined in the datasheets. In the cases
where marking is not defined in the datasheet, the following
table defines the option information that is marked on the
product.
OPTION TYPE
MARKING
X001, X001T
X001, X1 (1)
X006
No mark
X007, X007T
X007
X008, X008T
X008
X009, X009T
No mark
X016
X001
X017, X017T
X017
X018, X018T
X018
X019, X019T
X001
Note
(1) X1 is used on the SOP and SOIC-8 where there are space
constraints.
Rev. 2.0, 24-Aug-15
Note
The information in this document provides generic information on
options but for specific information on a product the appropriate
product datasheet should be used.
Document Number: 83713
7
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000