ZGL41-100A thru ZGL41-200A
www.vishay.com
Vishay General Semiconductor
Surface Mount Glass Passivated Power
Voltage-Regulating Diodes
FEATURES
• Plastic MELF package
• Ideal for automated placement
• Glass passivated chip junction
• Low Zener impedance
• Low regulation factor
• Meets MSL level 1, per J-STD-020C, LF maximum peak
of 250 °C
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
GL41 (DO-213AB)
TYPICAL APPLICATIONS
DESIGN SUPPORT TOOLS AVAILABLE
3D 3D
3D Models
For general
applications.
purpose
regulation
and
protection
MECHANICAL DATA
Case: GL41 (DO-213AB)
PRIMARY CHARACTERISTICS
VZ
100 V to 200 V
Ptot
1000 mW
IR
1.0 μA
TJ max.
150 °C
VZ specification
Pulse current
Circuit configuration
Single
Molding compound meets UL 94 V-0 flammability rating
Base P/N-E3 - RoHS-compliant, commercial grade
Terminals: matte tin plated leads, solderable
J-STD-002 and JESD 22-B102
M3 suffix meets JESD 201 class 1A whisker test
per
Polarity: red band denotes Zener diode and positive
(cathode)
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
PARAMETER
Operating junction and storage temperature range
SYMBOL
VALUE
UNIT
TJ, TSTG
-55 to +150
°C
Revision: 19-Feb-18
Document Number: 88409
1
For technical questions within your region: DiodesAmericas@vishay.com, DiodesEurope@vishay.com, DiodesAsia@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
ZGL41-100A thru ZGL41-200A
www.vishay.com
Vishay General Semiconductor
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
ZENER VOLTAGE
RANGE
PART
NUMBER (1)
TEST
CURRENT
VZ at IZT
IZT
V
IZK
MAXIMUM ZENER
IMPEDANCE
ZZT AT IZT
MIN.
NOM.
MAX.
ZGL41-100A
95
100
105
3.7
ZGL41-110A
104
110
116
ZGL41-120A
114
120
ZGL41-130A
124
130
ZGL41-140A
133
ZGL41-150A
ZZK AT IZK
mA
MAXIMUM
REVERSE
CURRENT
MAXIMUM
CONTINUOUS
FORWARD
VOLTAGE
IR at VR
VF at 0.5 A
IRM
V
mADC
MAX.
MAX.
μA
V
MAXIMUM
SURGE
CURRENT (2)
MAX.
MAX.
0.25
250
3100
1.0
76.0
1.5
10.0
3.4
0.25
300
4000
1.0
83.6
1.5
9.1
126
3.1
0.25
380
4500
1.0
91.2
1.5
8.3
137
2.9
0.25
450
5000
1.0
98.8
1.5
7.7
140
147
2.7
0.25
525
5500
1.0
106.4
1.5
7.1
142
150
158
2.5
0.25
600
6000
1.0
114.0
1.5
6.7
ZGL41-160A
152
160
168
2.3
0.25
700
6500
1.0
121.6
1.5
6.3
ZGL41-170A
162
170
179
2.2
0.25
800
6750
1.0
129.2
1.5
5.9
ZGL41-180A
171
180
189
2.1
0.25
900
7000
1.0
136.9
1.5
5.6
ZGL41-190A
180
190
200
2.0
0.25
1050
7500
1.0
144.4
1.5
5.3
ZGL41-200A
190
200
210
1.9
0.25
1200
8000
1.0
152.0
1.5
5.0
Notes
(1) Surge current is a non-repetitive, 8.3 ms pulse width square wave or equivalent sine-wave superimposed on I per JEDEC method
ZT
(2) Maximum steady state power dissipation is 1.0 W at T = 75 °C
L
ORDERING INFORMATION (Example)
PREFERRED P/N
UNIT WEIGHT (g)
PREFERRED PACKAGE CODE
BASE QUANTITY
DELIVERY MODE
ZGL41-100A-E3/96
0.134
96
1500
7" diameter plastic tape and reel
ZGL41-100A-E3/97
0.134
97
5000
13" diameter plastic tape and reel
RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted)
10000
60 Hz
Resistive or
Inductive Load
ZZ - Dynamic Zener Impedance (Ω)
Ptot - Power Dissipation (W)
1.0
0.75
0.5
0.25
PCB Mounted on
0.31" x 0.31" x 0.08"
(8 mm x 8 mm x 2 mm)
Copper Pad Areas
0
VZ = 200 V
VZ = 180 V
1000
VZ = 150 V
VZ = 120 V
100
VZ = 100 V
10
25
50
75
100
125
150
175
0.1
1
TL - Lead Temperature (°C)
IZT - Zener Test Current (mA)
Fig. 1 - Maximum Continuous Power Dissipation
Fig. 2 - Typical Zener Impedance
10
Revision: 19-Feb-18
Document Number: 88409
2
For technical questions within your region: DiodesAmericas@vishay.com, DiodesEurope@vishay.com, DiodesAsia@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
ZGL41-100A thru ZGL41-200A
www.vishay.com
Vishay General Semiconductor
VZ - Temperature Coefficient (mV/°C)
Instantaneous Forward Current (A)
10
1
TJ = 25 °C
Pulse Width = 300 µs
1 % Duty Cycle
0.1
0.01
0.4
0.6
0.8
1
1.2
1.4
200
Tested at Rated IZT
180
160
140
120
100
80
100 110 120 130 140 150 160 170 180 190 200
1.6
Instantaneous Forward Voltage (V)
VZ - Zener Voltage (V)
Fig. 3 - Typical Instantaneous Forward Characteristics
Fig. 5 - Steady State Power Derating Curve
10
10
IZT - Test Zener Current (mA)
Instantaneous Reverse Current (µA)
220
1
TJ = 100 °C
0.1
1
TJ = 25 °C
0.1
100
0.01
0
20
40
60
80
100
150
200
250
Percent of Rated Zener Voltage (%)
VZ - Zener Voltage (V)
Fig. 4 - Typical Reverse Characteristics
Fig. 6 - Typical Zener Voltage
PACKAGE OUTLINE DIMENSIONS in inches (millimeters)
GL41 (DO-213AB)
Mounting Pad Layout
Solderable Ends
1st Band
D2
0.022 (0.56)
0.018 (0.46)
0
D2 = D1 +
- 0.008 (0.20)
0.138 (3.5)
MAX.
D1 =
0.105
0.095
(2.67)
(2.41)
0.022 (0.56)
0.018 (0.46)
0.205 (5.2)
0.185 (4.7)
0.118 (3.0)
MIN.
0.049 (1.25)
MIN.
0.238 (6.0)
REF.
1st band denotes type and positive end (cathode)
Revision: 19-Feb-18
Document Number: 88409
3
For technical questions within your region: DiodesAmericas@vishay.com, DiodesEurope@vishay.com, DiodesAsia@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product
with the properties described in the product specification is suitable for use in a particular application. Parameters provided in
datasheets and / or specifications may vary in different applications and performance may vary over time. All operating
parameters, including typical parameters, must be validated for each customer application by the customer's technical experts.
Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited
to the warranty expressed therein.
Hyperlinks included in this datasheet may direct users to third-party websites. These links are provided as a convenience and
for informational purposes only. Inclusion of these hyperlinks does not constitute an endorsement or an approval by Vishay of
any of the products, services or opinions of the corporation, organization or individual associated with the third-party website.
Vishay disclaims any and all liability and bears no responsibility for the accuracy, legality or content of the third-party website
or for that of subsequent links.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
© 2022 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED
Revision: 01-Jan-2022
1
Document Number: 91000