0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LTD104C11S

LTD104C11S

  • 厂商:

    TOSHIBA(东芝)

  • 封装:

  • 描述:

    LTD104C11S - 26CM COLOUR TFT LCD MODULE - Toshiba Semiconductor

  • 数据手册
  • 价格&库存
LTD104C11S 数据手册
Toshiba Matsushita Display Technology Co., Ltd PRODUCT INFORMATION 26cm COLOUR TFT-LCD MODULE (10.4 TYPE) LTD104C11S (a-Si TFT) All information is subject to change without notice. Please read bottom notes. FEATURES:(1)10.4” VGA color display with High Luminance (400cd/m2) (2)Wide Viewing Angle (Vertical:120, Horizontal:140) (3)Built in Long Life Lamps (50,000 h) TENTATIVE MECHANICAL SPECIFICATIONS Item Dimensional Outline (typ.) Number of Pixels Active Area Pixel Pitch Weight (approximately) Backlight Specifications 238.5(W) x 177.5(H) x 12max(D) mm 640(W) x 480(H) pixels 211.2(W) x 158.4(H) mm 0.33(W) x 0.33(H) 500g Twin CCFLs, Sidelight type ABSOLUTE MAXIMUM RATINGS Item (VDD) Supply Voltage (VFL) FL Driving Frequency (fFL) Input Signal Voltage (VIN) Operating Temperature (Note Storage Temperature Storage Humidity (Max. wet bulb temperature = 39°C) Min. -0.3 0 ---0.3 -10 -20 10 Max. 6.5 2.0 100 VDD+0.3 65 80 90 Unit V kV(rms) kHz V °C °C %(RH) Note) Only operation is guarantied at Operating Temperature. Display quality is evaluated at +25°C. ELECTRICAL SPECIFICATION (Ta=25°C) (RECOMMENDED OPERATION CONDITION) Item (VDD) Supply Voltage (VFL) FL Start Voltage High Level Input Voltage (VIH) Low Level Input Voltage (VIL) 1 Current Consumption * (IDD) 2 * (IFL) *1 *2 Power Consumption *1 : 8 color bars pattern *2 : Except the efficiency of FL inverter Min. 4.75 3.0 --1200 0.7 VDD 0 --3.0 --- Typ. 5.0 3.3 460 ------225 6.0 6.3 Max. 5.25 3.6 --1900 VDD 0.3 VDD --6.5 --- Unit V V V(rms) V(rms) V mA mA(rms) W Remarks VDD :5V VDD :3.3V Ta=-10°C IFL =6.0mA(rms) VDD :3.3V OPTICAL SPECIFICATION (Ta=25°C) Item Contrast Ratio (CR) Viewing Angle (Upper+Lower) (CR ≥ 10) (Left+Right) (τr) Response Time (τf) Luminance Lamp Life Time (MTBF)*3 *4 Min. 250 ----------Typ. 500 120 140 ----400 50,000 Max. ------50 50 --Unit --° ° ms ms cd/m2 h Remarks IFL=6.0mA(rms) *3 : Conditions ;Ta=25°C, IFL=6.0mA(rms), continuous lighting *4 : Definitions of failure ; 1) Lcd luminance becomes half of the minimum value. 2) Lamp doesn’t light normally. *The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by Toshiba Matsushita Display Technology or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Toshiba Matsushita Display Technology or others. *The information contained herein may be changed without prior notice. It is therefore advisable to contact Toshiba Matsushita Display Technology before proceeding with the design of equipment incorporating this product. (1/9) 2003-11-27 (Ver.0.4R) 238.5 ( 234.7) 230 .9 21 4.6(Bez el (1 16) 1 0 0 +1 0 Openi ng) 2.5 2 .5 11 .5 3.8 DIMENSIONAL OUTLINE 8 .7 4 4 213.2( Viewing Area) Area) 211.2( Active Area) Area) 158.4 (Active I/F Connector (Rear Side) (DF14H-2P-1.25H , DF14H-30P-1.25H) 160.4 (Viewin g 2 9.5 3.5 4 8 3.5 4 17 7.5 (157.1 ) Open ing) 132.6 16 1.8(Bez el TENTATIVE (66. 3) 37.5 + 1 4 9. 5 3.5 8 1 4.6 2 0.4 Standard tolerance : ±0.5 2003-11-27 (Ver.0.4R) 4 4 (2/9) 7 9 +1 4 7 +1 TENTATIVE Unit : mm 4 3.5 LTD104C11S LTD104C11S BLOCK DIAGRAM SEQUENCE OF POWER SUPPLIES AND SIGNALS (3/9) 2003-11-27 (Ver.0.4R) LTD104C11S TIMING CHART tv tvw VSYNC t h HSYNC t‚ vp † tvds tvbl nk DE 479 480 1 2 tvde t h t hw HSYNC tp hf DE 640 RGB data NCLK 12345 t hds t hde (4/9) 2003-11-27 (Ver.0.4R) LTD104C11S TIMING SPECIFICATION 1) 2) 3) 4) 5) 6) Item Frame Period Vertical blanking Term V-sync Pulse Width Vertical Front Porch Vertical Data Sync Period Vertical Display Term Horizontal Period H-sync Pulse Width Horizontal Front Porch Horizontal Data Sync Period Horizontal Display Term Clock Period Clock “H” Time Clock “L” Time Data Setup Time Data Hold Time Symbol tv tvblnk tvw tvfp tvds tvde th thw thfp thds thde tc tch tcl tds tdh min. 500 20 2 2 6 480 740 8 8 8 640 35.0 10.0 10.0 5.0 10.0 typ. 525 45 480 800 160 640 39.7 Max. 550 70 480 860 640 unit th th th th th th tc tc tc tc tc ns ns ns ns ns Note 1) If NCLK is fixed to "H" or "L" level for certain period while DE is supplied, the panel may be damaged. Note 2) Please adjust LCD operating signal timing and FL driving frequency, to optimize the display quality. There is a possibility that flicker is observed by the interference of LCD operating signal timing and FL driving condition (especially driving frequency), even if the condition satisfies above timing specifications and recommended operating conditions shown in 3. Note3 ) Do not make tv, th and tvds fluctuate. Note4) In case of using the long frame period, the deterioration of display quality, noise etc. may be occurred. Note5) NCLK count of each Horizontal Scanning Time should be always the same. V-Blanking period should be “n” X “Horizontal Scanning Time”. (n: integer) Frame period should be always the same. (5/9) 2003-11-27 (Ver.0.4R) LTD104C11S CONNECTOR PIN ASSIGNMENT FOR INTERFACE CN1 INPUT SIGNAL Connector : DF14H-30P-1.25H / HIROSE ELECTRIC CO., LTD. Mating Connector : DF14-30S-1.25C, Contact Pin : DF14-2628SCF Terminal No. Symbol Function 1 GND 2 NCLK SAMPLING CLOCK 3 H-Sync HORIZONTAL SYNC. 4 V-Sync VERTICAL SYNC. 5 GND 6 R02) RED DISPLAY DATA (LSB) 7 R12) RED DISPLAY DATA 8 R22) RED DISPLAY DATA 9 R32) RED DISPLAY DATA 10 R42) RED DISPLAY DATA 11 R52) RED DISPLAY DATA (MSB) 12 GND 13 G02) GREEN DISPLAY DATA (LSB) 14 G12) GREEN DISPLAY DATA 15 G22) GREEN DISPLAY DATA 16 G32) GREEN DISPLAY DATA 17 G42) GREEN DISPLAY DATA 18 G52) GREEN DISPLAY DATA (MSB) 19 GND 20 B02) BLUE DISPLAY DATA (LSB) 21 B12) BLUE DISPLAY DATA 22 B22) BLUE DISPLAY DATA 23 B32) BLUE DISPLAY DATA 24 B42) BLUE DISPLAY DATA 25 B52) BLUE DISPLAY DATA (MSB) 26 DE DATA ENABLE 27 GND 28 VDD +3.3V (+5.0V)POWER SUPPLY 29 VDD +3.3V (+5.0V)POWER SUPPLY 30 GND CN2 INPUT SIGNAL Connector : DF14H-2P-1.25H / HIROSE ELECTRIC CO., LTD. Mating Connector : DF14-2S-1.25C, Contact Pin : DF14-2628SCF Terminal No. Symbol Function 1 UD VERTICAL REVERSE(“L” level or Open ; normal, ”H” level ; reverse) 2 RL HORIZONTAL REVERSE (“L” level or Open ; normal , ”H” level ; reverse) CN3 / 4 CCFL POWER SOURCE Connector : BHR-04VS-1 / JAPAN SOLDERLESS TERMINAL MFG CO., LTD. Mating Connector3) : SM04(4.0)B-BHS-1 / JAPAN SOLDERLESS TERMINAL MFG CO., LTD. Terminal No. Symbol Function 1 VFLH1 CCFL Power Supply ( high voltage) 2 VFLH2 CCFL Power Supply ( high voltage) 1) 3 NC Non Connection (open) 4 VFLL CCFL Power Supply (low voltage) Note 1) NC terminal should be open. Note 2) See next page. Note 3) Take away terminal No.3 of the mating connector. If does not take away, it may cause smoke burn of electrical parts by high voltage. (6/9) 2003-11-27 (Ver.0.4R) LTD104C11S 256k (k=1024) COLORS COMBINATION TABLE Display Black Blue Green Light Blue Red Purple Yellow White Black Dark ↑ ↓ Light Red Black Dark ↑ ↓ Light Green Black Dark ↑ ↓ Light Blue Black Gray Scale of White & Black Dark ↑ ↓ Light White R5 R4 R3 R2 R1 R0 L L L L H H H H L L L L L L L H H H H L L L L L L L H H H H L L L : : H H H L L L H H H L L L H H H L L L : : L L L L L L L L L L L L L L L L L L : : L L L L L L L L L L L L L L L L L L : : H H H H H H H H H H H H L H H H L H H H H H H H H H H L L L L L L L L L L L H L L L L H L L L L L L L L L L L L L L L L L L L : : H H H L H H H L H H H H H H H H H H L L L L L L L L L L L L L L L L L L H H H L L L H H H L L L H H H L L L : : L L L L L L L L L L L H L L L L H L H H H L L L H H H L L L H H H L L L : : H H H L H H H L H H H H L L L L H H L L L H L H L L L L L L L L L L L L L L L L L L L L L : : H H H L L L L H H L L L H L H L L L L L L L L L L L L L L L L L L L L L : : H H H L L L L H H L L H H L H L H L L L L L H H H H L L L L L L L H H H H L L H L L L L H H H H L H L G5 G4 G3 G2 G1 G0 L L H H L L H H L L L L L H H L L H H L L L L L H H L L H H L L L : : L L L L L L L L L L L H L L L L H L L L L L L L L L L L L L L L L L L L : : L L L L L L L L L L L H L L L L H L L L H H L L H H L L L L L H H L L H H L L L L L H H L L H H L L L B5 B4 B3 B2 B1 B0 L H L H L H L H L L L L H L H L H L H L L L L H L H L H L H L L L : : L L L L L L L L L L L L L L L L L L L H L H L H L H L L L L H L H L H L H L L L L H L H L H L H L L L Gray Scale Level L0 L1 L2 L3… L60 L61 L62 Red L63 L0 L1 L2 L3… L60 L61 L62 Green L63 L0 L1 L2 L3… L60 L61 L62 Blue L63 L0 L1 L2 L3… L60 L61 L62 White L63 Basic Color Gray Scale of Red Gray Scale of Green Gray Scale of Blue (7/9) 2003-11-27 (Ver.0.4R) LTD104C11S RELIABILITY TEST TEST CONDITIONS 1) The module should be driven and inspected under normal test conditions. 2) The module should not have condensation of water (moisture) on the module. 3) The module should be inspected after two or more hours storage in normal conditions (15 - 35°C,45 - 65%(RH)). 4) A module shall be used only for one test. SPECIFICATIONS The module shall have no failure in the following reliability test items. Test Item High Temperature Operation 1) High Temperature Storage 2) High Temperature High Humidity operation 1) Low Temperature Operation 1) Low Temperature Storage 2) 2) Temperature Shock Test Conditions 65°C 192 h 80°C 192 h 50°C 80% 192 h -10°C 192 h -20°C 192 h -20°C ⇔ 80°C 0.5h 0.5h 50 cycles 10 - 200 - 10Hz sweep/cycle, 1.5×9.8m/s2 constant, X.Y.Z each directions, 0.5h each 50×9.8m/s2 , 20ms, ±X, ±Y, ±Z direction, one time each Result OK OK OK OK OK OK Mechanical Vibration 2) OK Mechanical Shock 2) OK Note 1) Operating Note 2) Non-Operating Definitions of failure for judgment shall be as follows: 1) Function of the module should be maintained. 2) Current consumption should be smaller than the specified value. 3) Appearance and display quality should not have distinguished degradation. 4) Luminance should be larger than 50% of the minimum value specified in OPTICAL SPECIFICATION. (8/9) 2003-11-27 (Ver.0.4R) LTD104C11S ! FOR SAFETY LCD module is generally designed with precise parts to achieve light weighted thin mechanical dimensions. In using our Modules, make certain that you fully understand and put into practice the warnings and safety precautions detailed in Engineering Information No.EE-N001,"CAUTIONS AND INSTRUCTIONS FOR TOSHIBA LCD MODULES". Refer to individual specifications and TECHNICAL DATA sheets (hereinafter called "TD") for more detailed technical information. 1) SPECIAL PURPOSES A) Toshiba Matsushita Display Technology's Standard LCD Modules have not been customized for operation in extreme environments or for use in applications where performance failures could be life-threatening or otherwise catastrophic. B) Since Toshiba Matsushita Display Technology's Standard LCD Modules have not been designed for operation in extreme environments, they must never be used in devices that will be exposed to abnormally high levels of vibration or shock which exceed Toshiba Matsushita Display Technology's published specification limits. C) In addition, since Toshiba Matsushita Display Technology Standard LCD Modules have not been designed for use in applications where performance failures could be life-threatening or catastrophic, they must never be installed in aircraft navigation control systems (such as, but not limited to Traffic Collision Avoidance System and Air Traffic Indicator), in military defense or weapons systems, in critical industrial process-control systems (e.g., those involved in the production of nuclear energy), or in critical medical device or patient life-support systems. 2) DISASSEMBLING OR MODIFICATION DO NOT DISASSEMBLE OR MODIFY the module. It may damage sensitive parts inside LCD module, and may cause scratches or dust on the display. Toshiba Matsushita Display Technology doses not warrant the module, if customer disassembled or modified it. 3) BREAKAGE OF LCD PANEL DO NOT INGEST liquid crystal material, DO NOT INHALE this material, and DO NOT CONTACT the material with skin, if LCD panel is broken and liquid crystal material spills out. If liquid crystal material comes into mouth or eyes, rinse mouth or eyes out with water immediately. If this material contact with skin or cloths, wash it off immediately with alcohol and rinse thoroughly with water. 4) GLASS OF LCD PANEL BE CAREFUL WITH CHIPS OF GLASS that may cause injuring fingers or skin, when the glass is broken. 5) ELECTRIC SHOCK DISCONNECT POWER SUPPLY before handling LCD module. DO NOT TOUCH the parts inside LCD module and the fluorescent lamp's connector or cables in order to prevent electric shock, because high voltage is supplied to these parts from the inverter unit while power supply is turned on. 6) ABSOLUTE MAXIMUM RATINGS AND POWER PROTECTION CIRCUIT DO NOT EXCEED the absolute maximum rating values under the worst probable conditions caused by the supply voltage variation, input voltage variation, variation in parts' constants, environmental temperature, etc., otherwise LCD module may be damaged. Employ protection circuit for power supply, whenever the specification or TD specifies it. Suitable protection circuit should be applied for each system design. 7) RECOMMENDED OPERATION CONDITIONS The performance and quality of the LCD panel are warranted only when the LCD panel is used within “the recommended operation conditions”. Toshiba Matsushita Display Technology Co., Ltd. never warrants the performance and quality of the LCD panel when you use the LCD panel over “the recommended operation conditions”, although within “the absolute maximum rating”. To use the LCD panel over “the recommended operation conditions” may have bad influence on the characteristics and reliability of the LCD panel and may shorten the life of the LCD panel. Therefore, when designing the whole set, not to be over “the recommended operation conditions”, you should fully take care of supply voltage change, characteristic of connection parts, serge of input-and-output line, and surrounding temperature. 8) DISPOSAL When dispose LCD module, obey to the applicable environmental regulations. (9/9) 2003-11-27 (Ver.0.4R)
LTD104C11S 价格&库存

很抱歉,暂时无法提供与“LTD104C11S”相匹配的价格&库存,您可以联系我们找货

免费人工找货