TC74VCX245FK

TC74VCX245FK

  • 厂商:

    TOSHIBA(东芝)

  • 封装:

  • 描述:

    TC74VCX245FK - Low-Voltage Octal Bus Transceiver with 3.6 V Tolerant Inputs and Outputs - Toshiba Se...

  • 详情介绍
  • 数据手册
  • 价格&库存
TC74VCX245FK 数据手册
TC74VCX245FT/FK/FTG TOSHIBA CMOS Digital Integrated Circuit Silicon Monolithic TC74VCX245FT, TC74VCX245FK, TC74VCX245FTG Low-Voltage Octal Bus Transceiver with 3.6 V Tolerant Inputs and Outputs The TC74VCX245 is a high performance CMOS octal bus transceiver which is guaranteed to operate from 1.2-V to 3.6-V. Designed for use in 1.5V, 1.8V, 2.5V or 3.3 V systems, it achieves high speed operation while maintaining the CMOS low power dissipation. It is also designed with over voltage tolerant inputs and outputs up to 3.6 V. The direction of data transmission is determined by the level of the DIR inputs. The OE inputs can be used to disable the device so that the busses are effectively isolated. All inputs are equipped with protection circuits against static discharge. TC74VCX245FT TC74VCX245FK Features (Note 1) (Note 2) (Note 3) • • Low voltage operation: VCC = 1.2~3.6 V High speed operation: tpd = 3.5 ns (max) (VCC = 3.0~3.6 V) tpd = 4.2 ns (max) (VCC = 2.3~2.7 V) tpd = 8.4 ns (max) (VCC = 1.65~1.95 V) tpd = 16.8 ns (max) (VCC = 1.4~1.6 V) tpd = 42.0 ns (max) (VCC = 1.2 V) • • 3.6 V tolerant inputs and outputs. Output current: IOH/IOL = ±24 mA (min) (VCC = 3.0 V) IOH/IOL = ±18 mA (min) (VCC = 2.3 V) IOH/IOL = ±6 mA (min) (VCC = 1.65 V) IOH/IOL = ±2 mA (min) (VCC = 1.4 V) • • • Latch-up performance: −300 mA ESD performance: Machine model ≥ ±200 V Human body model ≥ ±2000 V Package: TSSOP VSSOP (US) VQON • • Bidirectional interface between 2.5 V and 3.3 V signals. (Note 1) Power down protection is provided on all inputs and outputs. (Note 2) VQON20-0404-0.50 TC74VCX245FTG Weight TSSOP20-P-0044-0.65A VSSOP20-P-0030-0.50 VQON20-P-0404-0.50 : 0.08 g (typ.) : 0.03 g (typ.) : 0.0145g (typ.) Note 1: Do not apply a signal to any bus terminal when it is in the output mode. Damage may result. Note 2: All floating (high impedance) bus terminal must have their input level fixed by means of pull up or pull down resistors. Note 3: When mounting VQON package, the type of recommended flux is RA or RMA. 1 2007-10-19 TC74VCX245FT/FK/FTG Pin Assignment (top view) FT(TSSOP20-P-0044-0.65) FK(VSSOP20-P-0030-0.50) DIR A1 A2 A3 A4 A5 A6 A7 A8 1 2 3 4 5 6 7 8 9 20 19 18 17 16 15 14 13 12 11 VCC FTG(VQON20-P-0404-0.50) A1 DIR VCC OE 20 19 18 17 B1 16 OE B1 B2 B3 B4 B5 B6 B7 B8 6 A7 7 A2 A3 A4 A5 A6 1 2 3 4 5 15 14 13 12 11 B2 B3 B4 B5 B6 8 9 10 B7 A8 GND B8 GND 10 IEC Logic Symbol OE DIR 19 1 G3 3 EN 1 [BA] 3 EN 2 [AB] 1 2 A2 A3 A4 A5 A6 A7 A8 3 4 5 6 7 8 9 17 16 15 14 13 12 11 B2 B3 B4 B5 B6 B7 B8 18 B1 A1 2 Truth Table Inputs Outputs DIR L H X A=B B=A Z Function OE L L H A-Bus Output Input Z B-Bus Input Output X: Don’t care Z: High impedance 2 2007-10-19 TC74VCX245FT/FK/FTG Absolute Maximum Ratings (Note 1) Characteristics Power supply voltage DC input voltage (DIR, OE ) DC bus I/O voltage Input diode current Output diode current DC output current Power dissipation DC VCC/ground current Storage temperature Symbol VCC VIN VI/O IIK IOK IOUT PD ICC/IGND Tstg Rating −0.5~4.6 −0.5~4.6 −0.5~4.6 −50 ±50 ±50 Unit V V (Note 2) V mA (Note 4) mA mA mW mA °C −0.5~VCC + 0.5 (Note 3) 180 ±100 −65~150 Note 1: Exceeding any of the absolute maximum ratings, even briefly, lead to deterioration in IC performance or even destruction. Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum ratings and the operating ranges. Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook (“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test report and estimated failure rate, etc). Note 2: Off-state Note 3: High or low state. IOUT absolute maximum rating must be observed. Note 4: VOUT < GND, VOUT > VCC Operating Ranges (Note 1) Characteristics Supply voltage Input voltage (DIR, OE ) Bus I/O voltage Symbol VCC VIN VI/O Rating 1.2~3.6 −0.3~3.6 Unit V V (Note 2) (Note 3) (Note 4) (Note 5) (Note 6) (Note 7) °C (Note 8) ns/V mA V 0~3.6 0~VCC ±24 ±18 ±6 ±2 −40~85 Output current IOH/IOL Operating temperature Input rise and fall time Topr dt/dv 0~10 Note 1: The operating ranges must be maintained to ensure the normal operation of the device. Unused inputs and bus inputs must be tied to either VCC or GND. Please connect both bus inputs and the bus outputs with VCC or GND when the I/O of the bus terminal changes by the function. In this case, please note that the output is not short-circuited. Note 2: Off-state Note 3: High or low state Note 4: VCC = 3.0~3.6 V Note 5: VCC = 2.3~2.7 V Note 6: VCC = 1.65~1.95 V Note 7: VCC = 1.4~1.6 V Note 8: VIN = 0.8~2.0 V, VCC = 3.0 V 3 2007-10-19 TC74VCX245FT/FK/FTG Electrical Characteristics < DC Characteristics (Ta = −40~85°C, 2.7 V < VCC = 3.6 V) Characteristics High level Low level Symbol VIH VIL Test Condition ⎯ ⎯ VCC (V) 2.7~3.6 2.7~3.6 2.7~3.6 2.7 3.0 3.0 2.7~3.6 2.7 3.0 3.0 2.7~3.6 2.7~3.6 0 2.7~3.6 2.7~3.6 2.7~3.6 Min 2.0 ⎯ Max ⎯ Unit Input voltage 0.8 ⎯ ⎯ ⎯ ⎯ V IOH = −100 μA High level VOH VIN = VIH or VIL IOH = −12 mA IOH = −18 mA Output voltage IOH = −24 mA IOL = 100 μA Low level VOL VIN = VIH or VIL IOL = 12 mA IOL = 18 mA IOL = 24 mA Input leakage current 3-state output off-state current Power off leakage current Quiescent supply current Increase in ICC per input IIN IOZ IOFF ICC ΔICC VCC − 0.2 2.2 2.4 2.2 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ V 0.2 0.4 0.4 0.55 ±5.0 ±10.0 μA μA μA VIN = 0~3.6 V VIN = VIH or VIL VOUT = 0~3.6 V VIN, VOUT = 0~3.6 V VIN = VCC or GND VCC < (VIN, VOUT) < 3.6 V = = VIH = VCC − 0.6 V 10.0 20.0 ±20.0 μA 750 < < DC Characteristics (Ta = −40~85°C, 2.3 V = VCC = 2.7 V) Characteristics High level Low level Symbol VIH VIL Test Condition ⎯ ⎯ VCC (V) 2.3~2.7 2.3~2.7 2.3~2.7 2.3 2.3 2.3 2.3~2.7 2.3 2.3 2.3~2.7 2.3~2.7 0 2.3~2.7 2.3~2.7 Min 1.6 ⎯ Max ⎯ Unit Input voltage 0.7 ⎯ ⎯ ⎯ ⎯ V IOH = −100 μA High level Output voltage VOH VIN = VIH or VIL IOH = −6 mA IOH = −12 mA IOH = −18 mA IOL = 100 μA Low level VOL VIN = VIH or VIL IOL = 12 mA IOL = 18 mA Input leakage current 3-state output off-state current Power off leakage current Quiescent supply current IIN IOZ IOFF ICC VIN = 0~3.6 V VIN = VIH or VIL VOUT = 0~3.6 V VIN, VOUT = 0~3.6 V VIN = VCC or GND VCC < (VIN, VOUT) < 3.6 V = = VCC − 0.2 2.0 1.8 1.7 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ V 0.2 0.4 0.6 ±5.0 ±10.0 μA μA μA μA 10.0 20.0 ±20.0 4 2007-10-19 TC74VCX245FT/FK/FTG < DC Characteristics (Ta = −40~85°C, 1.65 V = VCC< 2.3 V) Characteristics Symbol Test Condition ⎯ ⎯ VCC (V) 1.65~2.3 1.65~2.3 Min 0.65 × VCC ⎯ Max ⎯ Unit High level Input voltage Low level VIH VIL 0.2 × VCC ⎯ ⎯ V High level Output voltage Low level Input leakage current 3-state output off-state current Power off leakage current Quiescent supply current VOH VIN = VIH or VIL IOH = −100 μA IOH = − 6 mA 1.65~2.3 1.65 1.65~2.3 1.65 1.65~2.3 1.65~2.3 0 1.65~2.3 1.65~2.3 VCC − 0.2 1.25 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ V VOL IIN IOZ IOFF ICC VIN = VIH or VIL VIN = 0~3.6 V VIN = VIH or VIL VOUT = 0~3.6 V VIN, VOUT = 0~3.6 V VIN = VCC or GND IOL = 100 μA IOL = 6 mA 0.2 0.3 ±5.0 ±10.0 μA μA μA μA 10.0 20.0 ±20.0 VCC < (VIN, VOUT) < 3.6 V = = < DC Characteristics (Ta = −40~85°C, 1.4 V = VCC< 1.65 V) Characteristics Symbol Test Condition ⎯ ⎯ VCC (V) 1.4~1.65 1.4~1.65 Min 0.65 × VCC ⎯ Max ⎯ Unit High level Input voltage Low level VIH VIL 0.05 × VCC ⎯ ⎯ V High level Output voltage Low level Input leakage current 3-state output off-state current Power off leakage current Quiescent supply current VOH VIN = VIH or VIL IOH = −100 μA IOH = −2 mA 1.4~1.65 1.4 1.4~1.65 1.4 1.4~1.65 1.4~1.65 0 1.4~1.65 1.4~1.65 VCC − 0.2 1.05 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ V VOL IIN IOZ IOFF ICC VIN = VIH or VIL VIN = 0~3.6 V VIN = VIH or VIL VOUT = 0~3.6 V VIN, VOUT = 0~3.6 V VIN = VCC or GND IOL = 100 μA IOL = 2 mA 0.05 0.35 ±5.0 ±10.0 μA μA μA μA 10.0 20.0 ±20.0 VCC < (VIN, VOUT) < 3.6 V = = 5 2007-10-19 TC74VCX245FT/FK/FTG < DC Characteristics (Ta = −40~85°C, 1.2 V = VCC < 1.4 V) Characteristics Symbol Test Condition ⎯ ⎯ VCC (V) 1.2~1.4 1.2~1.4 1.2 1.2 1.2 1.2 0 1.2 1.2 Min 0.8 × VCC ⎯ Max ⎯ Unit High level Input voltage Low level High level Low level Input leakage current 3-state output off-state current Power off leakage current Quiescent supply current VIH VIL VOH VOL IIN IOZ IOFF ICC VIN = VIH or VIL VIN = VIH or VIL VIN = 0~3.6 V VIN = VIH or VIL VOUT = 0~3.6 V VIN, VOUT = 0~3.6 V VIN = VCC or GND 0.05 × VCC ⎯ V Output voltage IOH = −100 μA IOL = 100 μA VCC − 0.1 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ V μA μA μA μA 0.05 ±5.0 ±10.0 10.0 20.0 ±20.0 VCC < (VIN, VOUT) < 3.6 V = = AC Characteristics (Ta = −40~85°C, Input: tr = tf = 2.0 ns, CL = 30 pF, RL = 500 Ω) (Note 1) Characteristics Symbol Test Condition VCC (V) 1.2 1.5 ± 0.1 1.8 ± 0.15 CL = 30 pF, RL = 500 Ω 2.5 ± 0.2 3.3 ± 0.3 CL = 15 pF, RL = 2 kΩ 3-state output enable time tpZL tpZH Figure 1, Figure 3 CL = 30 pF, RL = 500 Ω 1.2 1.5 ± 0.1 1.8 ± 0.15 2.5 ± 0.2 3.3 ± 0.3 CL = 15 pF, RL = 2 kΩ 3-state output disable time tpLZ tpHZ Figure 1, Figure 3 CL = 30 pF, RL = 500 Ω 1.2 1.5 ± 0.1 1.8 ± 0.15 2.5 ± 0.2 3.3 ± 0.3 CL = 15 pF, RL = 2 kΩ Output to output skew tosLH tosHL (Note 2) CL = 30 pF, RL = 500 Ω 1.2 1.5 ± 0.1 1.8 ± 0.15 2.5 ± 0.2 3.3 ± 0.3 Min 1.5 1.0 1.5 0.8 0.6 1.5 1.0 1.5 0.8 0.6 1.5 1.0 1.5 0.8 0.6 ⎯ ⎯ ⎯ ⎯ ⎯ Max 42.0 16.8 8.4 4.2 3.5 49.0 19.6 9.8 5.6 4.5 36.0 14.4 7.2 4.0 3.6 1.5 1.5 0.5 0.5 0.5 Unit CL = 15 pF, RL = 2 kΩ Propagation delay time tpLH tpHL Figure 1, Figure 2 ns ns ns ns Note 1: For CL = 50 pF, add approximately 300 ps to the AC maximum specification. Note 2: This parameter is guaranteed by design. (tosLH = |tpLHm − tpLHn|, tosHL = |tpHLm − tpHLn|) 6 2007-10-19 TC74VCX245FT/FK/FTG Dynamic Switching Characteristics (Ta = 25°C, Input: tr = tf = 2.0 ns, CL = 30 pF) Characteristics Symbol Test Condition VIH = 1.8 V, VIL = 0 V Quiet output maximum dynamic VOL VOLP VIH = 2.5 V, VIL = 0 V VIH = 3.3 V, VIL = 0 V VIH = 1.8 V, VIL = 0 V Quiet output minimum dynamic VOL VOLV VIH = 2.5 V, VIL = 0 V VIH = 3.3 V, VIL = 0 V VIH = 1.8 V, VIL = 0 V Quiet output minimum dynamic VOH VOHV VIH = 2.5 V, VIL = 0 V VIH = 3.3 V, VIL = 0 V (Note) (Note) (Note) (Note) (Note) (Note) (Note) (Note) (Note) VCC (V) 1.8 2.5 3.3 1.8 2.5 3.3 1.8 2.5 3.3 Typ. 0.25 0.6 0.8 −0.25 −0.6 −0.8 Unit V V 1.5 1.9 2.2 V Note: This parameter is guaranteed by design. Capacitive Characteristics (Ta = 25°C) Characteristics Input capacitance Bus I/O capacitance Power dissipation capacitance Symbol CIN CI/O CPD fIN = 10 MHz Test Condition ⎯ ⎯ VCC (V) 1.8, 2.5, 3.3 1.8, 2.5, 3.3 (Note) 1.8, 2.5, 3.3 Typ. 6 7 20 Unit pF pF pF Note: CPD is defined as the value of the internal equivalent capacitance which is calculated from the operating current consumption without load. Average operating current can be obtained by the equation: ICC (opr) = CPD・VCC・fIN + ICC/8 (per bit) 7 2007-10-19 TC74VCX245FT/FK/FTG AC Test Circuit 6.0 V or VCC × 2 Open GND Measure CL RL Switch RL Output Parameter tpLH, tpHL 6.0 V VCC × 2 Switch Open @VCC = 3.3 ± 0.3 V @VCC = 2.5 ± 0.2 V @VCC = 1.8 ± 0.15 V @VCC = 1.5 ± 0.1 V @VCC = 1.2 V GND Symbol 3.3 ± 0.3 V 2.5 ± 0.2 V 1.8 ± 0.15 V 500Ω 30pF VCC 1.5 ± 0.1 V 1.2 V 2kΩ 15pF tpLZ, tpZL RL CL tpHZ, tpZH Figure 1 AC Waveform tr 2.0 ns Input (A) tf 2.0 ns 90% VM 10% VIH GND VOH VM tpLH tpHL VOL Output (Y) Figure 2 tpLH, tpHL 8 2007-10-19 TC74VCX245FT/FK/FTG tr 2.0 ns Output Enable Control ( OE ) tpLZ Output (Y) Low to Off to Low tpHZ tf 2.0 ns 90% VM VIH 10% tpZL 3.0 V or VCC VX VM tpZH VOL VOH VM GND Outputs disabled Outputs enabled GND Output (Y) High to Off to High Outputs enabled VY Figure 3 tpLZ, tpHZ, tpZL, tpZH Symbol VIH VM VX VY VCC 3.3 ± 0.3 V 2.7 V 1.5 V VOL + 0.3 V VOH − 0.3 V 2.5 ± 0.2 V VCC VCC/2 VOL + 0.15 V VOH − 0.15 V 1.8 ± 0.15 V VCC VCC/2 VOL + 0.15 V VOH − 0.15 V 1.5 ± 0.1 V VCC VCC/2 VOL + 0.1 V VOH − 0.1 V 1.2 V VCC VCC/2 VOL + 0.1 V VOH − 0.1 V 9 2007-10-19 TC74VCX245FT/FK/FTG Package Dimensions Weight: 0.08 g (typ.) 10 2007-10-19 TC74VCX245FT/FK/FTG Package Dimensions Weight: 0.03 g (typ.) 11 2007-10-19 TC74VCX245FT/FK/FTG Package Dimensions VQON20-P-0404-0.50 Unit: mm Weight: 0.0145 g (typ.) 12 2007-10-19 TC74VCX245FT/FK/FTG RESTRICTIONS ON PRODUCT USE • The information contained herein is subject to change without notice. 20070701-EN • TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc. • The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.).These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in his document shall be made at the customer’s own risk. • The products described in this document shall not be used or embedded to any downstream products of which manufacture, use and/or sale are prohibited under any applicable laws and regulations. • Please contact your sales representative for product-by-product details in this document regarding RoHS compatibility. Please use these products in this document in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances. Toshiba assumes no liability for damage or losses occurring as a result of noncompliance with applicable laws and regulations. 13 2007-10-19
TC74VCX245FK
物料型号: - TC74VCX245FT - TC74VCX245FK - TC74VCX245FTG

器件简介: TC74VCX245是一款高性能CMOS八路总线收发器,工作电压范围为1.2V至3.6V。适用于1.5V、1.8V、2.5V或3.3V系统,实现了高速操作,同时保持CMOS的低功耗特性。该器件还设计有高达3.6V的过压容忍输入和输出。

引脚分配: - FT(TSSOP20-P-0044-0.65)和FTG(VQON20-P-0404-0.50)的引脚图在文档中有详细描述。

参数特性: - 高速操作:tpd = 3.5 ns (最大值) (VCC = 3.0~3.6 V) - 低电压操作:VCC = 1.2 ~ 3.6 V - 3.6V容忍输入和输出 - IOH/IOL = ±24 mA(最小值)(VCC=3.0 V)

功能详解: - 数据传输方向由DIR输入电平决定,OE输入可用于禁用设备,从而有效隔离总线。 - 所有输入都配备了防静电放电保护电路。 - 支持2.5V和3.3V信号之间的双向接口。 - 所有输入和输出都提供了断电保护。

应用信息: - 适用于一般电子应用,如计算机、个人设备、办公设备、测量设备、工业机器人、家用电器等。不适用于需要极高质量和/或可靠性的设备,或其故障可能导致人员伤亡的设备,如原子能控制仪器、飞机或航天器仪器、交通信号仪器、燃烧控制仪器、医疗仪器、各种安全设备等。

封装信息: - TSSOP20-P-0044-0.65A:重量0.08g(典型值) - VSSOP20-P-0030-0.50:重量0.03g(典型值) - VQON20-P-0404-0.50:重量0.0145g(典型值)
TC74VCX245FK 价格&库存

很抱歉,暂时无法提供与“TC74VCX245FK”相匹配的价格&库存,您可以联系我们找货