0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TSP180-124

TSP180-124

  • 厂商:

    TRACOPOWER

  • 封装:

  • 描述:

    TSP180-124 - Industrial Power Supplies TSP Series, 90-600 Watt - TRACO Electronic AG

  • 数据手册
  • 价格&库存
TSP180-124 数据手册
Industrial Power Supplies TSP Series, 90­–60­0­ Watt Innovative and Powerful Features! ◆ True industrial grade design ◆ Rugged metal case for harsh industrial environments compliant RoHS EMC LVD Scheme IEC 60950-1 CB UL 60950-1 UL 508 UL 60079-15 ATEX II3G IECEX ◆ For worldwide use – Autoselect input and international safety approvals ◆ ATEX and IECEx certification (opt. EX) ◆ Model TSP 0­90­-24N meets NEC class 2 ◆ Industrial operating temperature range: –25 °C to +70­ °C ◆ Variable output voltage ◆ Indefinite short circuit, overvoltage and overtemperature protection ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Power OK signal Remote On/Off Shock and vibration proof Wall mounting (opt.) Redundancy module Buffer module for power backup Battery controller module 3-year product warranty The TRACOPOWER TSP series is a new generation of high performance DIN-rail mount power supplies designed to work reliably even under difficult factory floor conditions. A high power reserve guarantees reliable start-up of loads with high inrush currents. Excellent electrical specifications and high immunity against electrical disturbances makes these compact modules the best choice to power sensitive loads in industrial process control systems, machine tools or other demanding industrial applications. Easy installation with detachable screw terminal block and snap-on mounting on DIN-rails. For system applications all models offer a DC-OK signal and external shut down function. Redundant operation with true power sharing is available as an option. With another option these power supplies can be extended to build a perfect DCUPS system with automatic battery management. The TSP series power supplies complies with the latest safety and EMC standards for industrial environments and are also available with ATEX certification for applications in hazardous locations (class I, division 2) Models *Order Code TSP 0­70­–2 TSP 0­90­–24 TSP 0­90­–24N TSP 0­90­–48 TSP 40­–2 TSP 80­–24 TSP 80­–48 TSP 360­–24 TSP 360­–48 TSP 60­0­–24 TSP 60­0­–36 TSP 60­0­–48 60­0­ W Output Power (Pmax) 78 W 90­ W 90­ W 96 W 56 W 80­ W 92 W 360­ W **Output Voltage (Vnom) 2 VDC 24 VDC 24 VDC 48 VDC 2 VDC 24 VDC 48 VDC 24 VDC 48 VDC 24 VDC 36 VDC 48 VDC ***Output Current (Imax) 6.5 A 3.75 A 3.75 A 2.0­ A 3.0­ A 7.5 A 4.0­ A 5.0­ A 7.5 A 25.0­ A 6.5 A 2.5 A * For ATEX / IECEx compliant model add appendix -EX to order code (24 VDC models only) ** Output voltage adjustable 12–14 VDC, 24–28 VDC and 48–56VDC *** Max. current at nominal output voltage and operating temperature up to 40 °C max. http://www.tracopower.com Page  of 3 Industrial Power Supplies TSP Series Product Features 90­–60­0­ Watt The Ultimate DIN - Rail Power Supply ! Remote On/Off Control Output for true N+ Redundancy or Batter y Operation Jumper for Parallel Operation or Battery Charge Mode selectable by Jumper Rugged, Ultracompact Metal Case, Shock and Vibration tested per IEC 60­0­68-2 Standard Industrial Safety Approval Package to comply with: IEC/EN 60­950­- UL/cUL 60­950­- UL 50­8, CSA-C22.2 No.0­7 EN/UL 60­0­79-5 ATEX 94/9/EC, IECEx (Opt. EX) ANSI/ISA 2.2.0­ EMC Compliance to EN 620­4-3 Standard for Industrial Power Supplies SEMI F47 Convection Cooling, no internal Fan, Thermal Overload Protection Self-locking DIN-rail fixing Latch or optional Wall Mounting Brackets Detachable Screw Terminal Block for quick disconnect and easy Installation Double Output Terminals for easy wiring of multiple loads Dual Color Status Indicator LED Adjustable Output Voltage Remote Diagnostic via floating Relay Contact or NPN Output Autorange Input for worldwide Use http://www.tracopower.com Page 2 of 3 Industrial Power Supplies TSP Series Input Specifications Input voltage range 85–132/87–264 VAC autoselect – output current derating at operation below 100 VAC see graph B, page 5 47 – 63 Hz EN 61000-3-2, Class A (for limited output power) 20 ms min. (full load 115/230 VAC) – TSP 070/090 – TSP 140/180 – TSP 360 – TSP 600 Recommended circuit breaker, characteristic C or fuse, slow blow type Efficiency 115 VAC < 12 A < 13 A < 16 A < 25 A 230 VAC < 20 A < 25 A < 25 A < 30 A 90­–60­0­ Watt Input voltage frequency Harmonic limits Holdup time Inrush current – TSP 070/090 6.0 A – TSP 140/180 6.0 A – TSP 360 10.0 A – TSP 600 15.0 A 87% typ. – 12 VDC models: – 24 VDC models: – 36 VDC model: – 48 VDC models: 12 – 14 VDC 24 – 28 VDC 36 – 42 VDC 48 – 56 VDC At output voltage higher than nominal output voltage max. output current has to be reduced accordingly, in order not to exceed max. output power. 0.5 % max. 0.5 % max. 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) current limitation at Imax. constant current, automatic recovery – 12 VDC models: – 24 VDC models: – 36 VDC model: – 48 VDC models: 20 V 35 V 43 V 60 V electronic overload protection switch off at overtemperature, automatic restart – 12 VDC models: – 24 VDC models: – 36 VDC model: – 48 VDC models: 16 V 35 V 48 V 63 V dual color LED (green: DC ok, red: DC off) Output Specifications Output voltage adj. range Regulation – Input variation – Load variation (10–100 %) Ripple and Noise (20MHz Bandwidth) Electronic short circuit protection Output overvoltage protection Overload protection Overtemperature protection Power back immunity Status indicator Power OK signal – trigger threshold: – 12 – 24 – 36 – 48 – 12 VDC VDC VDC VDC VDC models: models: models: models: models: – active output signal: (reference to –Vout) – relay output 9–11 V 18–22 V 27–34 V 36–46 V 11.0 V ±1.0 V (20 mA max. for TSP 070, 40 mA max. for TSP 140) – 24 VDC models: 22.0 V ±2.0V / 20 mA max. (10 mA max. for TSP 090, 20mA max. for others) – 36 VDC model: 34.0 V ±2.0V / 20 mA max. – 48 VDC models: 44.0 V ±4.0V / 15mA max. DC OK = contact closed rated: 30 VDC/1.0 A for 12/24 VDC models rated: 30 VDC/2.0 A for 36 VDC model rated: 48 VDC/0.5 A for 48 VDC models Page 3 of 3 http://www.tracopower.com Industrial Power Supplies TSP Series General Specifications Max. capacitive load Operating temperature range Cooling Storage temperature Humidity (non condensing) Pollution degree Temperature coefficient Reliability, calculated MTBF @ 25°C acc. to IEC 61709 unlimited –25 °C to +70 °C max. (–13 °F to +158°F) (for derating see graph A on page 5) convection cooling, no internal fan –25 °C to +85 °C (– 13°F to +185°F) 95 % rel. H max. 2 0.02 %/K – TSP 070/090 >1.8 Mio h – TSP 140 >1.2 Mio h – TSP 180/360/600 > 0.9 Mio h by ext. contact. DC on: -S contact open DC off: -S connectetd via 1Kohm to -Vout according to IEC/EN 60950-1, UL 60950-1, UL 508 – – – – – – – Information technology equipment Industrial control equipment Electrical equipment for machines Electronic equipment for power installation Safety transformers for SMPS Limited power source (model TSP 090-124N) Control equipment for hazardous location IEC/EN 60950-1, UL 60950-1, CSA-C22.2 No. 60950-1-03 UL 508, CSA-C22.2 No. 107 EN 60204 EN 50178 EN 61558-2-4 EN 60950 sect. 2.5 and NEC Class 2 UL 60079-15 ( Class I, Division 2, Groups A,B,C,D AEx n C II C T4 U) IEC/EN 60079-15 ( Class I, Zone 2, EEx nC II C T4 U), ( II3G EEX nAC IIC T4 (T5 with limited power) for IEC/EN 60950-1 w ww.tracopower.com/products/tsp-cb.pdf UL 60950-1 rec. File: E181381, UL 508C listed File: E210002 w ww.ul.com -> certifications (file no. 219759) for UL 60950-1, UL 508, UL 60079-15-02, ANSI/ISA 12.12.01, CSA-22.2 No. 60950-1-03, CSA C22.2 No. 107, CSA 60079-15-02 w ww.tracopower.com/products/tsp-csa.pdf certificate no. LCIE 07 ATEX 0004 U (option -EX only) w ww.tracopower.com/products/tsp-atex.pdf For IEC 60079-15 w ww.tracopower.com/products/tsp-iecex.pdf for EN 60950-1, EN 60204, EN 61558-2-4 w ww.tracopower.com/products/tsp-gs.pdf safety class I ( IEC 536) IP 20 ( IEC/EN 60529) EN 61000-6-3, EN 61204-3 EN 55011 class B, EN 55022 class B, EN 55011 class B, EN 55022 class B, EN 61000-6-2, EN 61204-3 IEC / EN 61000-4-2 4 kV / 8 kV criteria B IEC / EN 61000-4-3 10 V / m criteria B IEC / EN 61000-4-4 2 kV criteria B IEC / EN 61000-4-5 1 kV / 2 kV criteria B IEC / EN 61000-4-6 10 V criteria B IEC / EN 61000-4-8 30 A / m criteria B IEC / EN 61000-4-11 criteria B/C SEMI F47 w ww.tracopower.com/products/TSP_SemiF47.pdf 90­–60­0­ Watt Remote On/Off Isolation Safety standards Safety approvals and certifications – CB report – UL approvals – CSA certification – II3G ATEX 94/9/EC – IECEx scheme – GS certification Class of protection Degree of protection Electromagnetic compatibility (EMC), Emissions – Conducted RI suppression on input – Radiated RI suppression Electromagnetic compatibility (EMC), Immunity – Electrostatic discharge (ESD) – Radiated RF field immunity – Electrical fast transient / burst immunity – Surge immunity – Immunity to conducted RF disturbances – Power frequency field immunity – Mains voltage dips and interruptions – Voltage sag immunity http://www.tracopower.com Page 4 of 3 Industrial Power Supplies TSP Series General Specifications Environment Enclosure material Mounting – DIN-rail mounting – Wall mounting (option) Connection Installation instructions – Vibration acc. IEC 60068-2-6; – Shock acc. IEC 60068-2-27 3 axis, sine sweep, 10–55 Hz, 1 g, 1 oct/min 3 axis, 15 g half sine, 11 ms aluminium (chassis) / stainless steel (cover) for DIN-rails as per EN 50022-35x15/7.5 (snap-on with self-locking spring) with wall mounting bracket - see page 12 detachable screw terminals (plugs included) 2 terminals per output w ww.tracopower.com/products/tsp_inst.pdf 90­–60­0­ Watt Output Power Derating A) Output Power Derating vs Ambient Temperature B) Output Power Derating vs Input Voltage 100 90 Output Power [% Pmax] TSP 600 100 90 Output Power [% Pmax] 80 70 60 50 40 -25 TSP 090 TSP 180 TSP 360 80 70 60 50 40 85 90 100 110 115 132 187 Input Voltage [VAC] 230 264 TSP 070 TSP 140 40 50 Temperature [˚C] 60 70 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 5 of 3 Industrial Power Supplies TSP Series TSP–REM360­ Redundancy Module With this module and two power supplies of the TSP series (of same type) a highly reliable, truly redundant power system can be configured without any additional components. This module enforces the equivalent sharing of the output current by each power supply. The system is fully redundant and provides output power even if one power supply has completely failed e.g. by short circuit on the output. In the event of either power supply failing or being disconnected, the second unit will automatically supply the full current to the load. The redundancy of the system is monitored and if lost, indicated by an alarm output. The inputs are hot swappable and can be loaded up to 15 A each. 90­–60­0­ Watt Models Models Code Order (includes terminal plugs) TSP–REM360­ TSP–REM60­0­ Input 2 x 24 VDC 2 x Control input Max Power per Input 2 x 360 W 2 x 600 W Output Voltage adjust. 24 VDC (24–27 VDC) Output Power max. 360­ W 60­0­ W Function Diagram + DC IN 1 _ J1.2 J2.3 J2.4 J2.1 J2.2 Connector Positions Front view Output Load --++ Remote Link 2 Remote Link 1 + _ Bottom view Top view J1.1 TSP J3.1 J3.2 Remote Link 1 + DC IN 2 _ J1.4 Output Volt adjust J1.3 J4.1 TSP Power Supplies Remote Link 2 J4.2 REM Controller DC IN 1 DC IN 2 J5.1 J5.2 Redundancy ok Alarm Remote On/Off J5.3 J5.4 Alarm Remote On/Off -+-+ Specifications Operating temperature Electromagnetic compatibility Redundancy OK signal (Alarm) Dimensions Remote link cable (0.5m) Remote On/Off Installation instructions – 25 °C to 70 °C max. (–13 °F...+158 °F) derating above 40 °C (104 °F): 1.5 %/K in correspondence to connected units (no internal switching device) trigger threshold at 18...22VDC, contact open if both inputs failed see page 10 2 cables included with TSP-REM360 module by ext. contact: contact open = On, contact closed = Off w ww.tracopower.com/products/tsp-rem_inst.pdf http://www.tracopower.com Page 6 of 3 Industrial Power Supplies TSP Series TSP–BFM24 Buffer Module The TSP-BFM24 buffer module will hold the output voltage of a 24 VDC power supply after brown outs or voltage dips of up to ten full 50 Hz cycles. During this buffer period no deterioration of the 24 VDC output voltage will occur. For many applications this buffer module is an ideal and cost effective alternative to a battery based backup system. The buffer module consists of a large bank of capacitors. When the power supply is switched on, the buffer capacitors will be charged. This will take approximately 30 second and an opto-coupler signal indicates the “READY“ condition. When a power fail occurs, the capacitor bank is discharged, maintaining the output of the buffer module at its nominal voltage. This condition is indicated by an “POWER FAIL“ signal. The hold up time is typically 200 ms at 25 A and 4 seconds typically at 1,2 A. After 4 seconds the buffer device will switch off the output voltage. The operating modes of the module are also indicated by a LED on the front panel also. The major advantage of this buffer solution is, that it is fully maintenance free and its storage capability does not deteriorate over the live time of the product. 90­–60­0­ Watt Models Order code (includes terminal plugs) TSP-BFM24 Function Diagram J2.2 Operating Voltage Range 24...28VDC Buffer Time 20­0­ms typ. @ 25A max. 4.0­ s max. @.2A Connector Positions Output Power max. 60­0­ W Inhibit J2.1 Discharge TSP Charge J1.1 J1.2 J1.3 J1.4 Volt adjust Load J2.4 Active J2.3 Voltage Detection Voltage Detection J2.6 J2.5 Ready Specifications Operating temperature Electromagnetic compatibility Buffer voltage Charging Status signals Inhibit Dimensions Installation instructions http://www.tracopower.com – 25 °C to 70°C max. (–13°F to 158 °F) derating above 40 °C (104 °F): 1.5 %/K in correspondence to connected units (no internal switching device) adjustable, >1V below input voltage, min. 22VDC 0.6A max. / 30s max. Buffer Active , Buffer Ready (optocoupler output) and dual colour LED for status indication optocoupler input: 35V max.
TSP180-124 价格&库存

很抱歉,暂时无法提供与“TSP180-124”相匹配的价格&库存,您可以联系我们找货

免费人工找货