11/18/2016 | Page 1 of 5
Triad Magnetics
460 Harley Knox Blvd
Perris CA 92571
Tel: 951.277.0757 • Fax: 951.277.2757
Email: info@triadmagnetics.com • Website: www.triadmagnetics.com
ITEM # ABU125-540, 53.2 TO 58.8 VOLT (V) ADJUSTABLE
OUTPUT VOLTAGE RANGE ABU 125 SERIES SWITCH MODE
POWER SUPPLY
The ABU125-540 is a single output power supply. This power supply is designed for a wide variety applications where high
reliability is desired, including applications for the industrial and telecommunications markets. Excellent performance
specifications are provided, together with compliance to European EMC (EN55022, Class B and EN61000-3-2), and Low
Voltage directive (TUV EN60950).
Single Output AC/DC Power Supply with PFC.
Input Characteristics (at 25 ºC) | Output Characteristics (at 25 ºC) | General Specifications (at 25 ºC) | Environmental
Specifications (at 25 ºC) | EMC and Safety Specifications (at 25 ºC) | Specifications | Note
Input Characteristics (at 25 ºC)
Alternating Current (AC) Input
Voltage
90 to 264 V
Direct Current (DC) Input
Voltage
127 to 373 V
Input Frequency Range
47 to 63 Hz
Input Current at 115 VAC
1.6 A
11/18/2016 | Page 2 of 5
Input Current at Typical 230
VAC
0.8 A
Maximum Inrush Current at 115
VAC for Cold Start
30 A
Maximum Inrush Current at 230
VAC for Cold Start
60 A
Power Factor at 230 VAC for Full
Load
> 0.95
Power Factor at 115 VAC for Full
Load
> 0.98
Leakage Current at 240 VAC
< 2.4 mA
Output Characteristics (at 25 ºC)
Direct Current (DC) Output
Voltage
54 V
Direct Current (DC) Voltage
Tolerance
±2.0 %
Output Current (15 CFM Fan)
0 to 1.96 A
Output Current (Convection)
0 to 1.6 A
Output Power (15 CFM Fan)
106 W
Output Power (Convection)
87 W
Adjustable Output Voltage
Range1
53.2 to 58.8 V
Ripple and Noise Voltage at Peak
to Peak2
240 mV
Load Regulation
±1.0 %
Line Regulation
±0.5 %
Efficiency
88.0 %
11/18/2016 | Page 3 of 5
Start-Up Time at 230 VAC for
Full Load
1800 ms
Start-Up Time at 115 VAC for
Full Load
3600 ms
Rise-Up Time at 230 VAC for Full
Load
30 ms
Rise-Up Time at 115 VAC for Full
Load
30 ms
Hold-Up Time at 230 VAC for
Full Load
14 ms
Hold-Up Time at 115 VAC for
Full Load
14 ms
Overcurrent Protection3
2.86 to 3.9 A
Direct Current (DC) Over
Voltage Protection
64 to 75 V
Output Type
Constant Voltage
General Specifications (at 25 ºC)
Length
127 mm
5.0 in
Width
76.2 mm
3.0 in
Height
27.0 mm
1.05 in
Weight
300 g
Cooling
Natural Convection or Fan at 15 CFM
Isolation Resistance at 500 VDC
(Input (I/P) - Output (O/P))
100 MO
Isolation Resistance at 500 VDC
(Input (I/P) - Floating Gate (FG))
100 MO
11/18/2016 | Page 4 of 5
Isolation Resistance at 500 VDC
(Output (O/P) - Floating Gate
(FG))
100 MO
Alternating Current (AC)
Dielectric Strength (Input (I/P) Output (O/P))
3 kV
Alternating Current (AC)
Dielectric Strength (Input (I/P) Floating Gate (FG))
1.5 kV
Alternating Current (AC)
Dielectric Strength (Output (O/P)
to Floating Gate (FG))
0.5 kV
Warranty
3 years
Mean Time Between Failure
(MTBF) per MIL-HDBK-217F
(25 ºC)
> 200 Khr
Environmental Specifications (at 25 ºC)
Operating Temperature4
-40 to 70 ºC
Non-Condensing Relative
Operating Humidity
20 to 90 %
Storage Temperature
-40 to 85 ºC
Non-Condensing Relative Storage
Humidity
10 to 95 %
Temperature Drift (0 to 50 ºC)
< 0.04 %/ºC
Vibration
10 to 500 Hz, 2G 10 min/cycle, period of 60 min, each X, Y & Z
axis
EMC and Safety Specifications (at 25 ºC)
EMI Emissions
Compliance to EN55022, CISPR22 Class B (Conducted &
Radiated)
11/18/2016 | Page 5 of 5
Harmonic Current
Compliance to EN61000-3-2, 3
EMS Immunity
Compliance to EN61000-4-2, 3-6, 8 & 11; EN55024 heavy, light
industry level, criteria A
Safety Approval
TUV EN60950-1 (Insulation Class -1)
UL 60950-1
Note for EMC and Safety
Specifications at 25 ºC
The power supply is considered a component which will be installed
into a final equipment. The final equipment must be re-confirmed
that it still meets EMC directives.
EMC and Safety Agency certs pending.
Specifications
RoHS Compliance
As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
Industry Standards
CB
CE
MIL-HDBK-217F
RoHS
TUV
UL
Note
Note
1
1. All I/O connection shall Follow specified Model Label.
Output voltage can be adjusted at VR51.
Ripple and noise are measured at 20 MHz of bandwidth by using a 12 Inch (in) twisted-pair wire termination with a
0.1 µF and 47 µF parallel capacitors.
3 Hiccup mode. Resets automatically once the fault condition is removed.
4 Refer to output load derating curve.
2
很抱歉,暂时无法提供与“ABU125-540”相匹配的价格&库存,您可以联系我们找货
免费人工找货