Current Sense / Low Frequency
Tr a n s f o r m e r s
CSE184L
Description:
Triad’s low frequency current sense transformers are designed to monitor
current from 0.1 to 1 ampere at frequencies from 50 Hz to 400 Hz.
Electrical Specifications at 25º C:
Turns ratio: Primary to sense 1: 16.67
Suggested burden resistor: 60
Typical output: 110mV/Amp
Primary DCR: 125 mΩ maximum
Sense DCR: 23 Ω maximum
Operating Temperature: -30°C to 95°C
Storage Temperature: -50°C to 125°C
Maximum input: 1Arms, 0-240VAC circuit
Maximum output voltage: 4.0Vrms. Burden resistor value must be selected
to not exceed this voltage.
Energy Time (E.T.) = 30000V µS Max
Response Curve:
Construction:
These transformers are provided with Recognized Component electrical
insulation system (OBJY2), Class 130 (B), designated “B3”. Products are
designed, built and 100% tested for a hi-pot of 2500V, winding to winding and
1250V, winding to core.
Agency Files:
UL file E50476 – Electrical Insulation Systems, Class “B3”, 130C
UL file E205349 – Component, Instrument Transformer (XODW2)
PC BOARD
LAYOUT
RoHS Compliance: As of manufacturing date February 2016, all standard products meet
the requirements of 2015/863/EU, known as the RoHS 3 initiative.
*Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics
website for the most current version. For soldering and washing information please see
http://www.triadmagnetics.com/faq.html
web:www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
PRIMARY
SECONDARY
SCHEMATIC
Publish Date: April 18, 2019
很抱歉,暂时无法提供与“CSE184L”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+33.581751+4.03895
- 10+24.8758710+2.99188
- 25+22.5439225+2.71141
- 50+21.0886450+2.53638
- 100+19.85861100+2.38844
- 250+18.51782250+2.22718
- 500+17.68345500+2.12683
- 1000+16.978341000+2.04202
- 5000+15.733585000+1.89231