Current Sense / Low Frequency
Tr a n s f o r m e r s
CSE185L
Description:
Triad’s low frequency current sense transformers are designed to monitor
current from 0.1 to 3 ampere at frequencies from 50 Hz to 400 Hz.
Electrical Specifications at 25º C:
Turns ratio: Primary to sense 1: 50
Suggested burden resistor: 60
Typical output: 110mV/Amp
Primary DCR: 19.5 mΩ maximum
Sense DCR: 23 Ω maximum
Operating Temperature: -30°C to 95°C
Storage Temperature: -50°C to 125°C
Maximum input: 3Arms, 0-240VAC circuit
Maximum output voltage: 4.0Vrms. Burden resistor value must be selected
to not exceed this voltage.
Energy Time (E.T.): 30000V µS
Response Curve:
Construction:
These transformers are provided with Recognized Component electrical
insulation system (OBJY2), Class 130 (B), designated “B3”. Products are
designed, built and 100% tested for a hi-pot of 2500V, winding to winding and
1250V, winding to core.
Agency Files:
PC BOARD
LAYOUT
UL file E50476 – Electrical Insulation Systems, Class “B3”, 130C
UL file E205349 – Component, Instrument Transformer (XODW2)
RoHS Compliance: As of manufacturing date February 2016, all standard products meet
the requirements of 2015/863/EU, known as the RoHS 3 initiative.
*Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics
website for the most current version. For soldering and washing information please see
http://www.triadmagnetics.com/faq.html
web:www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
PRIMARY
SECONDARY
SCHEMATIC
Publish Date: April 18, 2019
很抱歉,暂时无法提供与“CSE185L”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+33.201101+4.11858
- 10+24.5891410+3.05028
- 25+22.2888225+2.76492
- 50+20.8531150+2.58682
- 100+19.63958100+2.43628
- 250+18.31672250+2.27218
- 500+17.49344500+2.17006
- 1000+16.796991000+2.08366
- 5000+15.566745000+1.93105