Triad’s low frequency current sense transformers are designed to monitor
current from 0.1 to 10 ampere at frequencies from 50 Hz to 400 Hz
Electrical Specifications at 25º C:
Turns ratio: Primary to sense 1: 166
Suggested burden resistor: 60
Typical output: See response curve below
Primary DCR: 2.0 mΩ maximum
Sense DCR: 23 Ω maximum
Operating Temperature: -30°C to 95°C
Storage Temperature: -50°C to 125°C
Maximum input: 10Arms, 0-240VAC circuit
Maximum output voltage: 4.0Vrms. Burden resistor value must be selected
to not exceed this voltage.
Energy Time (E.T.): 30000V µS Max
Response Curve:
Construction:
These transformers are provided with Recognized Component electrical
insulation system (OBJY2), Class 130 (B), designated “B3”. Products are
designed, built and 100% tested for a hi-pot of 2500V, winding to winding and
1250V, winding to core.
PC BOARD
LAYOUT
Agency Files:
UL file E50476 – Electrical Insulation Systems, Class “B3”, 130C
UL file E205349 – Component, Instrument Transformer (XODW2)
RoHS Compliance: As of manufacturing date February 2016, all standard products meet
the requirements of 2015/863/EU, known as the RoHS 3 initiative.
*Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics
website for the most current version. For soldering and washing information please see
http://www.triadmagnetics.com/faq.html
web:www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
10.5
PRIMARY
SCHEMATIC
Publish Date: April 18, 2019
SECONDARY
很抱歉,暂时无法提供与“CSE186L”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+27.537311+3.29255
- 10+20.4415310+2.44413
- 25+18.5235025+2.21480
- 50+17.3320450+2.07234
- 100+16.32374100+1.95178
- 250+15.22423250+1.82032
- 500+14.53981500+1.73848
- 1000+14.296971000+1.70945
- 国内价格 香港价格
- 10+16.8960010+2.02020
- 30+16.6174930+1.98690
- 100+16.33899100+1.95360
- 200+16.24615200+1.94250
- 500+15.78198500+1.88700