Switchmode/High Frequency
Gate Drive Transformers
GDE25-5
Description:
Triad gate drive transformers are used universally in all high frequency switching
topologies to isolate the control circuitry from the line-connected switches. The
Windings are interleaved for the lowest possible leakage inductance. Turn ratios
optimize coupling and enhance performance. Available with single or dual
secondaries, these transformers are constructed of UL rated 130° materials and are
easily standardized at operating frequencies of 200 kHz and beyond.
Electrical Specifications (@25C):
Max
Max
Min.
Max.
Min.
Turns
DCR 1-2
DCR Gate
ET Product
Leakage
Inductance
Ratio
.350 Ω
.875 Ω
540 VµSec
3.5 µH
.680 mH
1:1.5
1. 100
Operating Temperature: -40 to +80°C
Weight: .045 oz.
1.20
Technical Notes:
1. Drive to gate winding hi-pot tested at 3,750 VRMS.
2. Derate ET product by 32% for 50 kHz, 50% for 100 kHz and for
unidirectional operation.
3. Operation at rated current per winding renders approximately 40°
temperature rise.
.025 S Q
.150 MIN
.280 MAX
.700
Schematic:
1.040
.600
.200
1
DRIVE
2
.650
3
.850
GATE
6
.700
2
RoHS Compliance: As of manufacturing date February 2016, all standard products meet
the requirements of 2015/863/EU, known as the RoHS 3 initiative.
*Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics website for the most current version. For soldering and washing
information please see http://www.triadmagnetics.com/faq.html
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
. 0 4 0 D I A T1Y P
6 5
.600
4 3
.850
.200
2 PLC S
MOUNTING HOLE PATTERN TOP VIEW
Publish Date: June 13, 2019
很抱歉,暂时无法提供与“GDE25-5”相匹配的价格&库存,您可以联系我们找货