P OWER T RANSFORMER
CHASSIS MOUNT : Isolation
N-51X
Electrical Specifications (@25°C)
1. Maximum Power:
35 VA
2. Input Voltage:
115 V, 50 / 60 Hz
3. Output Voltage:
115V + 5%
4. Full Secondary Load: 0.30 Amps RMS
5. Voltage Regulation: 15 % TYP @ full load to no load
Description:
BLK
BLK
The N-51X is a power transformer for isolating equipment from direct connection to
the powerline. The primary and secondary coils are concentrically wound providing
excellent magnetic coupling. Having good magnetic coupling between windings
helps reduce leakage flux and phase shift.
A
Safety:
WHT
These units are designed with 1500V isolation between winding to winding and
between winding and core. Materials and construction are rated for Class B
insulation system.
B
D
Unit: In inches
C
D
2.281
3.687
2.125
3.125
C
.187 DIA (REF)
Weight: 1.70 lbs
Connections: 7.0±1” leads, 0.250±0.062” Skin & Tin
Schematic:
BLK
RED
BLK
RED
WHT
Input: Blk to Blk
Output: Red to Red
Shield: Wht
RoHS Compliance: As of manufacturing date February 2016, all standard products meet
the requirements of 2015/863/EU, known as the RoHS 3 initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact
Triad Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd
Perris, California
92571
Publish Date: May 31, 2019