A u d i o Tr a n s f o r m e r
D a t a / Vo i c e C o u p l i n g
TY-40 0P
Description:
The TY series transformers are used for a variety of applications including
impedance matching, isolation, repeat coil, line balancing, bridging and
hybrid circuit.
Electrical Specifications at 25º C:
Impedance
Max. DC
Typ.
Typ.
Typ. Freq.
DCR
(Ohms)
Current
Insertion
Return
Response
(Ohms)
Pri
Sec
(mA)
Loss (dB)
Loss (dB)
(dB)
Pri
Sec
600
600
90
1.75
15
±.5
76.5
108
Designed to meet FCC Part 68
Longitudinal Balance: (FCC 68.310) – 60 dB min. 200 – 1000 Hz
45 dB min. 1000 – 4000 Hz
Dielectric Strength: (FCC 68.304) – 1500VAC
DOT ABOVE #1 PIN
ON BOBBIN FLANGE
.820
MAX
.750
MAX
Power Level: -45 dBm to +7 dBm
Frequency Range: 300 to 3500 Hz
.187 R EF
1
Operating Temperature: -20°C ~ 85°C
2
.715
MAX
Electrical Schematic:
1
3
.375
PRIMARY
SECONDARY
600
600
OHM
OHM
4
3
. 0 6 0 DI A HOL ES
.420
2
4
1
RoHS Compliance: As of manufacturing date February 2016, all standard products
meet the requirements of 2015/863/EU, known as the RoHS 3 initiative.
*Upon printing, this document is considered “uncontrolled”. Please contact
Triad Magnetics website for the most current version. For soldering and
washing information please see http://www.triadmagnetics.com/faq.html
web:www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: May 31, 2019
2
很抱歉,暂时无法提供与“TY-400P-B”相匹配的价格&库存,您可以联系我们找货