P OWER TRANSFORMER CHASSIS MOUNT : CONNECT WORLD SERIES
VPS10-2500
Electrical Specifications (@25C) 1. Maximum Power: 25.0VA 2. Secondary: Series: 10.0V CT@ 2.5A Parallel: 5.0V @ 5.0A 3. Voltage Regulation: 25% TYP @ full load to no load 4. Temperature Rise: 30C TYP ( 45C MAX allowed) 5. Insulation Resistance: 100M Construction: Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds UL flammability requirements. Safety: These units are designed with 4000VAC isolation between the primary and secondary, and also, between each winding and the core. Since the dual bobbin construction effectively reduces capacitance, electrostatic shielding is not required. World Series Transformers are designed and manufactured to meet the following agency approvals:
D B
Agency File: UL: File E53148, UL 506, General Purpose. CSA: File LR 37220. C22.2 NO. 66, General Purpose. VDE: File 18786-3390-0001, VDE/EN 60 950, (IEC950) information Technology Equipment. A. Dimensions:
H 2-5/16 W 2-13/16 D 1-15/16 A 2 B 1-1/8 C 5/16 T 3/16
C
A
Unit: In inches
MW 2-3/8 ML -
6 5
H
12 11 8 7
2 1
B. Mounting Hole Size: 3/16” C. WT Lbs. : 1.25 D. Schematic Diagram:
PARALLEL 6 12 CONNECTION 6 115/230V 50/60Hz 5 2 11 8 115V 50/60Hz 5 2 1 1 7 230V 50/60Hz SERIES CONNECTION 6 5 2 1
T
MW W
* Upon printing,this document is considered”uncontrolled”.Please contact Triad Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com Phone 909-277-0757 Fax 909-277-2757
22520B Temescal Canyon Road Corona, California 92883
Release Date: March 18, 2004 Revision: Initial Release