0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TMCM-6210-TMCL

TMCM-6210-TMCL

  • 厂商:

    TRINAMIC

  • 封装:

    MOTOR_215X100MM

  • 描述:

    Board 10 ~ 24VDC Supply 1.1A

  • 数据手册
  • 价格&库存
TMCM-6210-TMCL 数据手册
MODULES FOR STEPPER MOTORS MODULES Hardware Version V 1.10 HARDWARE MANUAL + + TMCM-6210 TMCM-6211 6-Axes Stepper Controller / Driver Up-to 0.7A RMS / 24V DC Encoder / HOME / STOP 4x analog / digital inputs 4x digital outputs Brake chopper support CAN, RS485, USB (TMCM-6210) EtherCAT™, USB (TMCM-6211) + TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany www.trinamic.com + TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) Table of contents 1 2 3 4 Life support policy ....................................................................................................................................................... 3 Features ........................................................................................................................................................................... 4 Order codes .................................................................................................................................................................... 5 Mechanical and Electrical Interfacing ..................................................................................................................... 6 4.1 Dimensions and Mounting Holes ................................................................................................................... 6 4.2 Board mounting considerations ...................................................................................................................... 7 5 Connectors of TMCM-6210 and TMCM-6211 ........................................................................................................... 8 5.1 TMCM-6210 Interface Brick ................................................................................................................................ 8 5.1.1 RS485 connector ............................................................................................................................................ 9 5.1.2 CAN connector ................................................................................................................................................ 9 5.1.3 USB connector .............................................................................................................................................. 10 5.1.4 Input connector ........................................................................................................................................... 10 5.1.5 Output connector ......................................................................................................................................... 11 5.2 TMCM-6211 Interface Brick .............................................................................................................................. 11 5.2.1 EtherCAT™ connector ................................................................................................................................. 12 5.2.2 USB connector .............................................................................................................................................. 12 5.2.3 Input connector ........................................................................................................................................... 12 5.2.4 Output connector ......................................................................................................................................... 13 5.3 TMCM-6210 + TMCM-6211 Driver Brick .......................................................................................................... 14 5.3.1 Motor connector........................................................................................................................................... 14 5.3.2 REF / HOME connector ................................................................................................................................ 15 5.3.3 Encoder connector....................................................................................................................................... 15 5.4 TMCM-6210 + TMCM-6211 Power supply Brick ........................................................................................... 16 5.4.1 Power connector.......................................................................................................................................... 17 5.4.2 Control connector ........................................................................................................................................ 17 5.4.3 Resistor connector....................................................................................................................................... 18 5.5 Power supply ...................................................................................................................................................... 18 5.6 RS485 ..................................................................................................................................................................... 18 5.7 CAN ........................................................................................................................................................................ 20 5.7.1 CAN adapter .................................................................................................................................................. 21 5.8 General purpose outputs OUT0..3 ................................................................................................................. 22 6 Motor driver current .................................................................................................................................................. 23 7 On Board LEDs............................................................................................................................................................. 24 7.1 Power supply brick ............................................................................................................................................ 24 7.2 TMCM-6210 Interface Brick .............................................................................................................................. 24 7.3 TMCM-6211 Interface Brick .............................................................................................................................. 25 8 Reset to Factory Default ........................................................................................................................................... 25 9 Operational ratings .................................................................................................................................................... 26 10 TMCM-6210 Functional Description ........................................................................................................................ 27 11 TMCM-6211 Functional Description ........................................................................................................................ 28 12 Revision History .......................................................................................................................................................... 29 12.1 Document revision ............................................................................................................................................ 29 12.2 Hardware revision ............................................................................................................................................. 29 13 References..................................................................................................................................................................... 29 Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG 2 TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 1 Life support policy TRINAMIC Motion Control GmbH & Co. KG does not authorize or warrant any of its products for use in life support systems, without the specific written consent of TRINAMIC Motion Control GmbH & Co. KG. Life support systems are equipment intended to support or sustain life, and whose failure to perform, when properly used in accordance with instructions provided, can be reasonably expected to result in personal injury or death. © TRINAMIC Motion Control GmbH & Co. KG 2015, 2016, 2017 Information given in this data sheet is believed to be accurate and reliable. However neither responsibility is assumed for the consequences of its use nor for any infringement of patents or other rights of third parties, which may result from its use. Specifications are subject to change without notice. Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG 3 TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 4 2 Features The TMCM-6210 / TMCM-6211 is a six axes controller/driver module for 2-phase bipolar stepper motors with separate encoder (differential) and HOME / STOP switch inputs for each axis. CAN, RS485 and USB (Micro-USB) interfaces are available on the TMCM-6210 and EtherCAT™ together with USB (Micro-USB) on the TMCM-6211 for communication. Furthermore the modules offer four analog / digital inputs and four digital outputs together with a brake chopper unit (supporting an external brake resistor) for supply voltage limitation when energy is fed back into the supply rail. MAIN CHARACTERISTICS Motion controller  Motion profile calculation in real-time  On the fly alteration of motor parameters (e.g. position, velocity, acceleration)  Dedicated HOME + STOP switch inputs (internal pull-ups)  High performance microcontroller for overall system control and communication protocol handling Bipolar stepper motor driver  Up to 256 microsteps per full step  High-efficient operation, low power dissipation  Dynamic current control  Integrated protection  stealthChop™ for quiet operation and smooth motion  dcStep™ feature for load dependent speed control  stallGuard2™ feature for stall detection  coolStep™ feature for reduced power consumption and heat dissipation Interfaces  TMCM-6210: CAN + RS485  TMCM-6211: EtherCAT™  USB full speed (12Mbit/s) device interface (Micro-USB)  Differential encoder input per motor axis (6x)  HOME, STOP_L, STOP_R switch inputs with internal pull-ups per motor axis (6x)  4 general purpose analog inputs (0..10V) or digital inputs (accept +24V signals)  4 general purpose digital outputs (open-drain, 500mA each) Software  TMCL™ remote (direct mode) and standalone operation with memory for up to 1024 TMCL commands  TMCM-6210: CANopen firmware available  TMCM-6211: CoE (CANopen over EtherCAT™) firmware available Electrical data  Supply voltage: nom. +12V and +24V with +10V … +27V supply voltage operating range  Motor current: up to 0.7A RMS (programmable) Mechanical data  Board size: 215mm x 100mm, overall height 21mm max. (incl. pcb but, without mating connectors and cables)  12x M3 mounting holes (optional) Please see separate TMCM-6210 / TMCM-6211 Software / Firmware documentation for additional information regarding programming and communication protocol. Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 5 3 Order codes The TMCM-6210 unit is available with two different firmware options: Order code TMCM-6210-TMCL TMCM-6210-CANopen Size of unit Description 6-axes controller / driver up-to 0.7A RMS / +24V, CAN 215mm x 100mm x 21mm + RS485 + USB with standard TMCL firmware 6-axes controller / driver up-to 0.7A RMS / +24V, CAN 215mm x 100mm x 21mm + RS485 + USB with CANopen firmware Table 3.1: TMCM-6210 order code The TMCM-6211 unit is available as: Order code TMCM-6211-CoE Size of unit Description 6-axes controller / driver up-to 0.7A RMS / +24V, 215mm x 100mm x 21mm EtherCAT™ + USB with CANopen over EtherCAT™ firmware Table 3.2: TMCM-6211 order code A cable loom is available, also: Order code G4-CABLE Description Cable loom for TMCM-6210/6211, TMCM-6212/6213, TMCM-3212/3213, TMCM-3214/3215, TMCM-3312/3313 and TMCM-3314/3315. Contains: 1x cable loom for RS485 connector (6210) 1x standard CAT5 cable with 2x RJ45 for CAN / EtherCAT (6210/6211) 1x RJ45-2-DSUB_G4_V10 adapter (for CAN RJ45 D-SUB translation) (6210) 1x Micro-USB cable (6210/6211) 1x cable loom for INPUTs connector (6210/6211) 1x cable loom for OUTPUTs connector (6210/6211) 6x cable loom for MOTOR connector (small) (6210/6211) 3x cable loom for MOTOR connector (big) 6x cable loom for ENCODER connector (6210/6211) 6x cable loom for REF / HOME connector (6210/6211) 1 cable loom for POWER connector (small) (6210/6211) 1x cable loom for POWER connector (big) 1x cable loom for CONTROL connector (6210/6211) 1x cable loom for RESISTOR connector (6210/6211) Please note: there is one cable loom available for a complete family of modules in order to speed-up initial setup of these modules. The family consists of these currently planned / available modules: TMCM-6210/6211, TMCM6212/6213, TMCM-3212/3213, TMCM-3214/3215, TMCM-3312/3313 and TMCM-3314/3315. Not all cables are required for all modules – some cable will fit or will be helpful for some modules, only. Module numbers in parenthesis behind each cable in the table above indicate whether the particular part of the cable loom can be used with the TMCM-6210 and / or TMCM-6211. Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 6 4 Mechanical and Electrical Interfacing 4.1 Dimensions and Mounting Holes The dimensions of the TMCM-6210 and TMCM-6211 controller/driver board are approx. 215mm x 100mm x 21mm. Maximum component height (height above PCB level) without mating connectors is around 17mm above PCB level and 2mm below PCB level. There are 12 mounting holes for M3 screws (3.2mm diameter) altogether for mounting the PCB. Figure 4.1 Dimension of TMCM-6210 / TMCM-6211 and position of mounting holes Please note: TMCM-6210 and TMCM-6211 share the same PCB with different assembly options regarding the interface section. Dimensions, mounting holes and board mounting considerations (see chapter below) are the same for both boards. Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 7 4.2 Board mounting considerations The TMCM-6210 / TMCM-6211 offer 12 metal plated mounting holes. One hole (lower right) is connected to onboard system ground (connected to power supply input ground) via 1M (500VDC) || 1nF (1kV). The same combination or resistor and capacitor is used for connecting the RJ45 shield ground (connector enclosure) to power supply input ground (see figure 4.1). 1M 1nF 1nF 1M n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. 1M 1nF Figure 4.2 TMCM-6210 / TMCM-6211 mounting hole connections All other mounting holes are electrically isolated. Please note that not all holes have to be used for mounting the pcb. At least the mounting holes in all four corners and two in the middle (6 altogether) should be used to ensure adequate support of the pcb when inserting / removing connectors in order to avoid significant bending of the pcb. In any case: please remove / attach mating connectors carefully – supporting the pcb if necessary! Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 8 5 Connectors of TMCM-6210 and TMCM-6211 The TMCM-6210 and TMCM-6211 are two members of a new family of modules with a modular architecture composed of so called “bricks”. The TMCM-6210 and TMCM-6211 consist of one interface brick, three dual-axes stepper motor controller / driver bricks and one supply brick. With the TMCM-6210 the interface brick offers CAN and RS485 interfaces while with the TMCM-6211 the EtherCAT™ option is assembled instead. All other bricks are the same for both modules. Motor 1 Interface Brick Motor 3 Motor 5 Motor 0 Motor 2 Motor 4 Driver Brick Driver Brick Driver Brick Supply Brick Figure 5.1 different bricks used for the TMCM-6210 / TMCM-6211 5.1 TMCM-6210 Interface Brick The interface brick of the TMCM-6210 offers RS485, CAN and USB interfaces for communication, four general purpose analog inputs (which can be used as digital inputs as well) and four open-drain outputs. RS485 connector (2x) 1 GND 2 RS485+ 3 RS485- 1 3 3 1 1 8 USB (MicroUSB) connector Output connector 1 OUT0 2 OUT1 3 OUT2 4 OUT3 5 6 7 8 +24V_FUSE +24V_FUSE +24V_FUSE +24V_FUSE 8 5 10 6 4 1 5 1 8 1 CAN connector (2x) 1 CAN_H 2 CAN_L 3 GND 4 n.c. 5 n.c. 6 n.c. 7 n.c. 8 n.c. Input connector 1 +24V_FUSE 2 AIN0 3 AIN1 4 AIN2 5 AIN3 Figure 5.2 TMCM-6210 interface brick Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG 6 7 8 9 10 GND GND GND GND GND TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 9 Connector and mating connector overview: Label Connector type RS485 connector (2x) Mating connector type Molex MicroFit™, 436500315 1x4 pin header, 3mm pitch CAN connector (2x) RJ45 plug connector USB (MicroUSB) connector Micro-USB connector, type B (USB device interface) Input connector Molex MicroFit™, 430451012 2x5 pin header, 3mm pitch Output connector Molex MicroFit™, 430450812 2x4 pin header, 3mm pitch Molex MicroFit™, Housing: 43645-0300 Contacts: 43030-0007 e.g. Standard CAT 5 / CAT 5e cables may be used Standard Micro-USB Molex MicroFit™, Housing: 43025-1000 Contacts: 43030-0007 Molex MicroFit™, Housing: 43025-0800 Contacts: 43030-0007 Table 5.1 TMCM-6210 interface brick: connectors and mating connectors 5.1.1 RS485 connector There are two RS485 connectors on the board with the same pin assignment – pins directly connected to each other. The second connector may be used for attaching a bus termination resistor to the RS485 bus (there is no termination resistor on-board) or for further distribution of the RS485 bus signals to other RS485 communication nodes while maintaining a proper bus structure. A three pin Molex MicroFit™ connector (Molex part no. 436500315) is used for RS485 connection. Mating connector housing e.g. Molex 43645-0300, contacts Molex 43030-0007. Please note that there are alternative options available from Molex for both, housing and contacts. 3 1 Pin 1 2 3 Label GND RS485+ RS485- Direction Power Bi-directional Bi-directional Description Supply and signal ground RS485 interface, diff. signal (non-inverting) RS485 interface, diff signal (inverting) Table 5.1: Interface Brick: RS485 connector 5.1.2 CAN connector There are two CAN connectors on the board with the same pin assignment – pins directly connected to each other. The second one may be used for attaching a bus termination resistor to the RS485 bus (there is no termination resistor on-board) or for further distribution of the CAN bus signals to other CAN nodes while maintaining a proper bus structure. A standard RJ45 plug connector is used for CAN communication. Standard CAT cables (e.g. CAT 5, non-crossing) might be used for connection. Pin assignment of the RJ45 is based on the CiA 303-1 recommendation. 8 1 Pin 1 2 3 4 5 6 7 8 Label CAN_H CAN_L GND n.c. n.c. n.c. n.c. n.c. Direction Bi-Directional Bi-directional Power Description CAN interface, diff signal (non-inverting) CAN interface, diff signal (inverting) Supply and signal ground Table 5.2 Interface Brick: CAN connector Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 10 5.1.3 USB connector The TMCM-6210 / TMCM-6211 offers a Micro USB connector (Type B, device interface) for communication. The USB interface supports USB high speed communication (12Mbit/s). With USB attached the digital logic part of the TMCM-6210 / TMCM-6211 will be supplied via USB (USB powered mode) if there is no main supply available. This mode may be used for firmware-updates, TMCL-program download or parameter settings etc. (requires USB connection, only). Please note that in USB stand-alone mode (main board supply available) the board might still draw current from the USB supply – depending on the voltage level of the USB +5V and the on-board generated +5V. 5.1.4 Input connector The TMCM-6210 / TMCM-6211 offer four analog inputs (nom. 0..10V range) which may be used as digital inputs, also (+24V tolerant). The four inputs are available via one 10 pin Molex MicroFit™ connector (Molex part no. 430451012). Mating connector housing e.g. Molex 43025-1000, contacts Molex 43030-0007. Please note that there are alternative options available from Molex for both, mating housing and contacts. Pin 10 6 5 1 Label Direction 1 +24V_FUSE Power output 2 3 4 5 6 7 8 9 10 AIN0 AIN1 AIN2 AIN3 GND GND GND GND GND Input Input Input Input Power Power Power Power Power Description Connected via fuse (polyfuse) to power supply input (+24V_LOGIC supply input on power control connector). Max. output current (together with all +24V_FUSE supply outputs on output connector: 500mA / polyfuse protected) Analog input channel 0 (nom. 0..10V) Analog input channel 1 (nom. 0..10V) Analog input channel 2 (nom. 0..10V) Analog input channel 3 (nom. 0..10V) Supply and signal ground Supply and signal ground Supply and signal ground Supply and signal ground Supply and signal ground Table 5.3: Interface Brick: Input connector Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 11 5.1.5 Output connector The TMCM-6210 / TMCM-6211 offer four digital outputs (open-drain). The four outputs are available via one 8 pin Molex MicroFit™ connector (Molex part no. 43045-0812). Mating connector housing e.g. Molex 43025-0800, contacts Molex 43030-0007. Please note that there are alternative options available from Molex for both, mating housing and contacts. 8 5 4 1 Pin 1 2 3 4 Label OUT0 OUT1 OUT2 OUT3 Direction Output Output Output Output Description 5 +24V_FUSE Power output 6 +24V_FUSE Power output 7 +24V_FUSE Power output 8 +24V_FUSE Power output Open-drain output Open-drain output Open-drain output Open-drain output Connected via fuse (polyfuse) to power supply input (+24V_LOGIC supply input on power control connector). Max. output current (together with all +24V_FUSE supply outputs on output connector: 500mA / polyfuse protected) Connected via fuse (polyfuse) to power supply input (+24V_LOGIC supply input on power control connector). Max. output current (together with all +24V_FUSE supply outputs on output connector: 500mA / polyfuse protected) Connected via fuse (polyfuse) to power supply input (+24V_LOGIC supply input on power control connector). Max. output current (together with all +24V_FUSE supply outputs on output connector: 500mA / polyfuse protected) Connected via fuse (polyfuse) to power supply input (+24V_LOGIC supply input on power control connector). Max. output current (together with all +24V_FUSE supply outputs on output connector: 500mA / polyfuse protected) Table 5.4: Interface Brick: Output connector 5.2 TMCM-6211 Interface Brick The interface brick of the TMCM-6210 offers EtherCAT™ and USB interfaces for communication, four general purpose analog inputs (which can be used as digital inputs as well) and four open-drain outputs. LINK IN 8 1 USB (MicroUSB) connector Output connector 1 OUT0 2 OUT1 3 OUT2 4 OUT3 5 6 7 8 +24V_FUSE +24V_FUSE +24V_FUSE +24V_FUSE 8 5 10 6 4 1 5 1 LINK OUT 8 1 EtherCAT connector (2x) 1 TX+ 2 TX3 RX+ 4 5 6 RX7 8 Input connector 1 +24V_FUSE 2 AIN0 3 AIN1 4 AIN2 5 AIN3 Figure 5.3 TMCM-6211 interface brick Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG 6 7 8 9 10 GND GND GND GND GND TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 12 Connector and mating connector overview: Label Connector type Mating connector type RJ45 plug connector e.g. Standard CAT 5 / CAT 5e cables suitable for 100Mbit/s Ethernet Micro-USB connector, type B (USB device interface) Standard Micro-USB EtherCAT™ connector (2x) USB (MicroUSB) connector Input connector Molex MicroFit™, 43045-1012 2x5 pin header, 3mm pitch Output connector Molex MicroFit™, 43045-0812 2x4 pin header, 3mm pitch Molex MicroFit™, Housing: 43025-1000 Contacts: 43030-0007 Molex MicroFit™, Housing: 43025-0800 Contacts: 43030-0007 Table 5.5: TMCM-6211 interface brick: connectors and mating connectors 5.2.1 EtherCAT™ connector There are two EtherCAT™ connectors on the board – one for LINK IN (towards / coming from EtherCAT™ master) and one for LINK OUT (for connecting further slaves) connection. A standard RJ45 plug connector (as used for 10/100Mbit/s Ethernet) is used for EtherCAT™ communication. Standard CAT cables suitable for 100Mbit/s Ethernet (e.g. CAT 5 / 5e etc.) might be used for connection. The PHYs used on the TMCM-6211 support auto MDI-X – therefore, TX and RX signals on the connector might be exchanged – e.g. cables with straight-through pin-assignment can be used. 8 1 Pin 1 2 3 4 5 6 7 8 Label TX+ TXRX+ Direction Output Output Input Description Transmit data output, differential, non-inverting Transmit data output, differential, inverting Receive data input, differential, non-inverting RX- Input Receive data input, differential, inverting Table 5.6: TMCM-6211 Interface Brick: EtherCAT™ connector 5.2.2 USB connector The TMCM-6210 / TMCM-6211 offers a Micro USB connector (Type B, device interface) for communication. The USB interface supports USB high speed communication (12Mbit/s). With USB attached the digital logic part of the TMCM-6210 / TMCM-6211 will be supplied via USB (USB powered mode) if there is no main supply available. This mode may be used for firmware-updates, TMCL-program download or parameter settings etc. (requires USB connection, only). Please note that in USB stand-alone mode (main board supply available) the board might still draw current from the USB supply – depending on the voltage level of the USB +5V and the on-board generated +5V. 5.2.3 Input connector The TMCM-6210 / TMCM-6211 offer four analog inputs (nom. 0..10V range) which may be used as digital inputs, also (+24V tolerant). The four inputs are available via one 10 pin Molex MicroFit™ connector (Molex part no. 430451012). Mating connector housing e.g. Molex 43025-1000, contacts Molex 43030-0007. Please note that there are alternative options available from Molex for both, mating housing and contacts. Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) Pin 10 6 5 1 Label Direction 1 +24V_FUSE Power output 2 3 4 5 6 7 8 9 10 AIN0 AIN1 AIN2 AIN3 GND GND GND GND GND Input Input Input Input Power Power Power Power Power 13 Description Connected via fuse (polyfuse) to power supply input (+24V_LOGIC supply input on power control connector). Max. output current (together with all +24V_FUSE supply outputs on output connector: 500mA / polyfuse protected) Analog input channel 0 (nom. 0..10V) Analog input channel 1 (nom. 0..10V) Analog input channel 2 (nom. 0..10V) Analog input channel 3 (nom. 0..10V) Supply and signal ground Supply and signal ground Supply and signal ground Supply and signal ground Supply and signal ground Table 5.7: Interface Brick: Input connector 5.2.4 Output connector The TMCM-6210 / TMCM-6211 offer four digital outputs (open-drain). The four outputs are available via one 8 pin Molex MicroFit™ connector (Molex part no. 43045-0812). Mating connector housing e.g. Molex 43025-0800, contacts Molex 43030-0007. Please note that there are alternative options available from Molex for both, mating housing and contacts. 8 5 4 1 Pin 1 2 3 4 Label OUT0 OUT1 OUT2 OUT3 Direction Output Output Output Output 5 +24V_FUSE Power output 6 +24V_FUSE Power output 7 +24V_FUSE Power output 8 +24V_FUSE Power output Description Open-drain output channel 0 Open-drain output channel 1 Open-drain output channel 2 Open-drain output channel 3 Connected via fuse (polyfuse) to power supply input (+24V_LOGIC supply input on power control connector). Max. output current (together with all +24V_FUSE supply outputs on output connector: 500mA / polyfuse protected) Connected via fuse (polyfuse) to power supply input (+24V_LOGIC supply input on power control connector). Max. output current (together with all +24V_FUSE supply outputs on output connector: 500mA / polyfuse protected) Connected via fuse (polyfuse) to power supply input (+24V_LOGIC supply input on power control connector). Max. output current (together with all +24V_FUSE supply outputs on output connector: 500mA / polyfuse protected) Connected via fuse (polyfuse) to power supply input (+24V_LOGIC supply input on power control connector). Max. output current (together with all +24V_FUSE supply outputs on output connector: 500mA / polyfuse protected) Table 5.8: Interface Brick: Output connector Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 14 5.3 TMCM-6210 + TMCM-6211 Driver Brick The driver brick of the TMCM-6210 and TMCM-6211 offers two outputs for bipolar stepper motors with up-to 0.7A RMS / 1.0A peak motor current (programmable), separate HOME + REFL and REFR inputs and encoder inputs (for incremental ABN encoders with differential signals) for each motor axes. Please note that due to sharing of hardware resources either REFL and REFR inputs or encoder inputs are available at a given point in time and may be used. The TMCM-6210 and TMCM-6211 offer three such driver bricks, supporting 6 stepper motors altogether. Motor connector 1 2 3 4 1 5 1 2 6 3 Motor connector 1 OA1 2 OB1 4 3 2 1 3 OA2 4 OB2 8 4 4 8 3 4 Encoder connector REF / HOME connector 4 1 5 1 REF / HOME connector 1 GND 4 +5V_OUT 2 REFL 5 REFR 3 HOME 6 GND Encoder connector 1 GND 2 ENC_A+ 3 ENC_B+ 4 ENC_N+ 5 6 7 8 +5V_OUT ENC_AENC_BENC_N- Figure 5.4 TMCM-6210 + TMCM-6211 Driver Brick Label Connector type Motor connector Mating connector type Molex MicroFit Jr.™, 43045-0412 2x2 pin header, 3mm pitch REF / HOME connector Molex MicroFit™, 43045-0612 2x3 pin header, 3mm pitch Encoder connector Molex MicroFit™, 43045-0812 2x4 pin header, 3mm pitch Molex MicroFit Jr.™, Housing: 43025-0400 Contacts: 43030-0007 Molex MicroFit™, Housing: 43025-0600 Contacts: 43030-0007 Molex MicroFit™, Housing: 43025-0800 Contacts: 43030-0007 Table 5.9 TMCM-6210 and TMCM-6211 Driver brick: connectors and mating connectors 5.3.1 Motor connector As there are two bipolar stepper motors supported per single driver brick there are also two motor connectors per brick. Each motor (with two coils A + B and four connecting wires) can be connected via one 4 pin Molex MicroFit™ connector (Molex part no. 43045-0412). Mating connector housing e.g. Molex 43025-0400, contacts Molex 430300007. Please note that there are alternative options available from Molex for both, mating housing and contacts. 4 3 2 1 Pin 1 2 3 4 Label OA1 OB1 OA2 OB2 Direction Output Output Output Output Description Motor Motor Motor Motor coil coil coil coil A B A B Table 5.10: Driver Brick: Motor connector Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 15 CAUTION Do not connect or disconnect motor during operation! Motor cable and motor inductivity might lead to voltage spikes when the motor is disconnected / connected while energized. These voltage spikes might exceed voltage limits of the driver MOSFETs and might permanently damage them. Therefore, always switch off and / or disconnect power supply before connecting / disconnecting the motor. 5.3.2 REF / HOME connector There are two REF / HOME connectors per single driver brick – one for each motor axis. HOME, REFL and / or REFR switches may be connected via one 6 pin Molex MicroFit™ connector (Molex part no. 43045-0612). Mating connector housing e.g. Molex 43025-0600, contacts Molex 43030-0007. Please note that there are alternative options available from Molex for both, mating housing and contacts. 6 4 3 1 Pin 1 Label GND Direction Power 2 REFL Input 3 HOME Input 4 +5V_OUT Power output 5 REFR Input 6 GND Power Description Supply and signal ground REF left / Left stop switch input. Internal pull-up (5k6) to +5V. External switch to ground may be connected or upto +5V push-pull signal. Home switch input. Internal pull-up (5k6) to +5V. External switch to ground may be connected or up-to +5V pushpull signal. Connected to the on-board +5V auxiliary DC/DC converter. All +5V_OUT power supply outputs together on the 6 REF / HOME and 6 Encoder connectors may draw up-to 1A (e.g. 100mA per encoder and up-to 20mA per REF / HOME switch). REF right / Right stop switch input. Internal pull-up (5k6) to +5V. External switch to ground may be connected or up-to +5V push-pull signal. Supply and signal ground Table 5.11: Driver Brick: REF / HOME connector 5.3.3 Encoder connector There are two Encoder connectors per single driver brick – one for each motor axis. Incremental A/B/N encoders with differential encoder signals are supported. The TMCM-6210 / TMCM-6211 offer on-board differential line receivers (AM26LV32 or equivalent) with 120R termination resistor per differential signal pair. Differential encoder signals may be connected via one 8 pin Molex MicroFit™ connector (Molex part no. 43045-0812). Mating connector housing e.g. Molex 43025-0800, contacts Molex 43030-0007. Please note that there are alternative options available from Molex for both, mating housing and contacts. Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 8 5 4 1 Pin 1 2 3 Label GND ENC_A+ ENC_B+ Direction Power Input Input 4 ENC_N+ Input 5 +5V_OUT Power output 6 7 ENC_AENC_B- Input Input 8 ENC_N- Input 16 Description Supply and signal ground Differential input of encoder channel A, non-inverting input Differential input of encoder channel B, non-inverting input Differential input of encoder null / zero channel, noninverting input Connected to the on-board +5V auxiliary DC/DC converter. All +5V_OUT power supply outputs together on the 6 REF / HOME and 6 Encoder connectors may draw up-to 1A (e.g. 100mA per encoder and up-to 20mA per REF / HOME switch). Differential input of encoder channel A, inverting input Differential input of encoder channel B, inverting input Differential input of encoder null / zero channel, inverting input Table 5.12: Driver Brick: Encoder connector 5.4 TMCM-6210 + TMCM-6211 Power supply Brick The power supply brick of the TMCM-6210 and TMCM-6211 offers one main supply input via the Power connector, separate logic supply input as an option and a hardware driver stage enable input on the Control connector and connection for an external brake connector with the on-board brake chopper circuit. Power connector 1 GND 2 +24V Control connector 1 2 3 4 GND +24V_LOGIC +24V_LOGIC Enable Resistor connector 2 1 4 2 1 1 +24V 2 Resistor 1 Figure 5.5: TMCM-6210 + TMCM-6211 Power supply Brick Connector and mating connector overview: Label Power connector Control connector Resistor connector Connector type Molex MiniFit Jr.™, 39-28-1023 1x2 pin header, 4.2mm pitch Molex MicroFit™, 43650-0415 1x4 pin header, 3mm pitch Molex MicroFit™, 43650-0215 2x4 pin header, 3mm pitch Mating connector type Molex MiniFit Jr.™, Housing: 39-01-2020 Contacts: 39-00-0039 Molex MicroFit™, Housing: 43645-0400 Contacts: 43030-0007 Molex MicroFit™, Housing: 43645-0200 Contacts: 43030-0007 Table 5.13 TMCM-6210 and TMCM-6211 Power supply brick: connectors and mating connectors Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 17 5.4.1 Power connector A two pin Molex MiniFit Jr.™ connector (Molex part no. 39-28-1023) is available for power supply connection. Mating connector housing e.g. Molex 39-01-2020, contacts Molex 39-00-0039. Please note that there are alternative options available from Molex for both, housing and contacts. 2 1 Pin 1 Label GND 2 +24V Direction Power Power supply input Description Supply and signal ground Power supply input. +12V … +24V +/- 10% regulated power supply input. Supply input for all six motor driver stages and logic supply. Table 5.14: Power supply Brick: Power connector CAUTION Always keep the power supply voltage (+24V) below the upper limit of 27V! Otherwise the driver electronics will be seriously damaged. Especially, when the selected operating voltage is near the upper limit a regulated power supply is highly recommended. Always keep the logic power supply voltage (+24V_LOGIC) above or equal to the main power supply! Otherwise the on-board electronics (diode connection between +24V main power supply input and +24V logic supply input) might be seriously damaged. 5.4.2 Control connector A four pin Molex MicroFit™ connector (Molex part no. 436500415) is used for the driver stage enable signal and optional separate logic supply input. Mating connector housing e.g. Molex 43645-0400, contacts Molex 43030-0007. Please note that there are alternative options available from Molex for both, housing and contacts. Pin 1 4 1 Label GND Direction Power Description Supply and signal ground Separate logic supply input. May be used in order to keep digital / logic part alive while driver stage is not supplied (Power supply input via Power connector either switched off or disconnected). 2 +24V_LOGIC Power supply input 3 +24V_LOGIC Power supply input Same as Pin 2. 4 ENABLE Input Driver stage enable input (logic high). Maybe connected to pin 3 / +24V_LOGIC in order to enable driver. Table 5.15: Power supply brick: Control connector CAUTION Always keep the digital logic power supply voltage (+24V_LOGIC) below the upper limit of 27V! Otherwise the on-board electronics might be seriously damaged. Especially, when the selected operating voltage is near the upper limit a regulated power supply is highly recommended. Always keep the logic power supply voltage (+24V_LOGIC) above or equal to the main power supply (on the Power supply connector)! Otherwise the on-board electronics (diode connection between +24V main power supply input and +24V logic supply input) might be seriously damaged. Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 18 5.4.3 Resistor connector The TMCM-6210 and TMCM-6211 offer a brake chopper in hardware for limiting supply voltage in case energy is fed back from motor / driver stage into the supply rail. A two pin Molex MicroFit™ connector (Molex part no. 43650-0215) is used for connecting an external brake resistor. Mating connector housing e.g. Molex 43645-0200, contacts Molex 43030-0007. Please note that there are alternative options available from Molex for both, housing and contacts. Pin 2 Label 1 +24V 2 Resistor 1 Direction Power supply input Output Description Connected to power supply input of Power connector. Brake chopper output. An external power resistor should be connected between Pin 1 and Pin 2 of this connector. Table 5.16: Power supply brick: Resistor connector 5.5 Power supply For proper operation care has to be taken with regard to power supply concept and design. The TMCM-6210 / TMCM-6211 includes about 2800µF/35V of supply filter capacitors. In addition, the module includes a 24V suppressor diode for over-voltage protection. Nevertheless, it is important to make sure that supply voltage will not rise beyond the upper limit of +27V! Please note: during motor deceleration the driver stage might feedback energy from the motor into the supply rail and supply voltage might increase. In order to limit the supply voltage a brake chopper circuit has been included on the board. When activated in software and together with an external power resistor this circuit will limit the supply voltage. CAUTION Always keep the power supply voltage (+24V) below the upper limit of 27V! Otherwise the on-board electronics might be seriously damaged. Especially, when the selected operating voltage is near the upper limit a regulated power supply is highly recommended. In addition, the on-board brake chopper may be used together with an external power resistor connected to the Resistor connector in order to limit supply voltage. Always keep the digital logic power supply voltage (+24V_LOGIC) below the upper limit of 27V! Otherwise the on-board electronics might be seriously damaged. Especially, when the selected operating voltage is near the upper limit a regulated power supply is highly recommended. Always keep the logic power supply voltage (+24V_LOGIC) above or equal to the main power supply (on the Power supply connector)! Otherwise the on-board electronics (diode connection between +24V main power supply input and +24V logic supply input) might be seriously damaged. There is limited reverse polarity protection, only! The module will short any reversed supply voltage. 5.6 RS485 For remote control and communication with a host system the TMCM-6210 provides a two wire RS485 bus interface. For proper operation the following items should be taken into account when setting up an RS485 network: 1. BUS STRUCTURE: The network topology should follow a bus structure as closely as possible. That is, the connection between each node and the bus itself should be as short as possible. Basically, it should be short compared to the length of the bus. The TMCM-6210 offers two connectors which are connected directly to each other and the on-board RS485 transceiver. Using both connectors for passing through the bus will help with keeping a proper bus topology. Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) Host c:> 19 Slave Slave Slave node 1 node n-1 node n } termination resistor (120 Ohm) termination resistor (120 Ohm) keep distance as short as possible RS485 Figure 5.3: Bus structure 2. BUS TERMINATION: Especially for longer busses and/or multiple nodes connected to the bus and/or high communication speeds, the bus should be properly terminated at both ends. The TMCM-6210 does not integrate any termination resistor. Therefore, 120 Ohm termination resistors at both ends of the bus have to be added externally. 3. NUMBER OF NODES: The RS485 electrical interface standard (EIA-485) allows up to 32 nodes to be connected to a single bus. The bus transceivers used on the TMCM-6110 units (SN65HVD1781D) have a significantly reduced bus load and allow a maximum of 255 units to be connected to a single RS485 bus using TMCL firmware. Please note: usually it cannot be expected to get reliable communication with the maximum number of nodes connected to one bus and maximum supported communication speed at the same time. Instead, a compromise has to be found between bus cable length, communication speed and number of nodes. 4. COMMUNICATION SPEED: The maximum RS485 communication speed supported by the TMCM-6210 hardware is 1Mbit/s. Factory default is 9600 bit/s. Please see separate firmware manuals for information regarding other possible communication speeds below the upper limit in hardware. 5. NO FLOATING BUS LINES: Avoid floating bus lines while neither the host/master nor one of the slaves along the bus line is transmitting data (all bus nodes switched to receive mode). Floating bus lines may lead to communication errors. In order to ensure valid signals on the bus it is recommended to use a resistor network connecting both bus lines to well defined logic levels. There are actually two options which can be recommended: Add resistor (Bias) network on one side of the bus, only (120R termination resistor still at both ends): termination resistor (220R) Slave Slave node n- 1 node n +5V pull-up (680R) RS485+ / RS485A termination resistor (120R) RS485- / RS485B pull-down (680R) GND Figure 4.4: Bus lines with resistor (Bias) network on one side, only Or add resistor (Bias) network at both ends of the bus (like Profibus™ termination): Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) +5V pull-up (390R) 20 Slave Slave node n- 1 node n +5V pull-up (390R) RS485+ / RS485A termination resistor (220R) termination resistor (220R) RS485- / RS485B pull-down (390R) pull-down (390R) GND GND Figure 4.5: Bus lines with resistor (Bias) network at both ends Certain RS485 interface converters available for PCs already include these additional resistors (e.g. USB-2485 with bias network at one end of the bus). 5.7 CAN For remote control and communication with a host system the TMCM-6210 provides a CAN bus interface. For proper operation the following items should be taken into account when setting up a CAN network: 1. BUS STRUCTURE: The network topology should follow a bus structure as closely as possible. That is, the connection between each node and the bus itself should be as short as possible. Basically, it should be short compared to the length of the bus. The TMCM-6210 offers two connectors (RJ45) which are connected directly to each other and the on-board CAN transceiver. Using both connectors for passing through the bus will help with keeping a proper bus topology. Host c:> Slave Slave Slave node 1 node n-1 node n } termination resistor (120 Ohm) CAN termination resistor (120 Ohm) keep distance as short as possible Figure 5.6: CAN bus structure 2. BUS TERMINATION: Especially for longer busses and/or multiple nodes connected to the bus and/or high communication speeds, the bus should be properly terminated at both ends. The TMCM-6210 does not integrate any termination resistor. Therefore, 120 Ohm termination resistors at both ends of the bus have to be added externally. Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 21 5.7.1 CAN adapter As part of the cable loom for the TMCM-6210 (G4-CABLE) an adapter pcb is vailable (RJ45-2-DSUB_G4_V10) for making CAN bus connection via standard D-SUB connectors instead of the RJ45 available on the TMCM-6210. A standard e.g. CAT5 ethernet cable might be used to connect the RJ45 connector on the TMCM-6210 with the RJ45 connector on the adapter pcb. The D-SUB connector on the adapter pcb might then be used to connect further slaves or the master with CAN D-SUB connectors. Please make sure to maintain a proper bus structure while using the adapter pcb. Figure 5.6: RJ45-2-DSUB PCB top view Figure 5.7: RJ45-2-DSUB schematic / connector pin assignment Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 22 5.8 General purpose outputs OUT0..3 The TMCM-6210 and TMCM-6211 offer 4 open-drain (N-channel MOSFET) general purpose outputs available at the output connector of the interface brick part. The internal connection of the N-channel MOSFETs together with a flyback / freewheeling diode can be seen in figure 5.8. When activating the MOSFET the related output will be pulled low (sometimes called npn-style switch). Please note the internal fuse limiting the current that can be drawn from the output connector. TMCM-6210 / TMCM-6211 +24V_LOGIC Polyfuse 0.5A/60V 5 8 1 4 OUT0 OUT1 OUT2 OUT3 microcontroller GND Output OUT0..3 with internal circuit of OUT0 as example Figure 5.8: General purpose output – internal circuit (simplified) Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 23 6 Motor driver current The stepper motor driver section of the TMCM-6210 + TMCM-6211 operates current controlled. The driver current may be programmed in software with 256 effective scaling steps in hardware up-to 0.7A RMS / 1A peak max. motor coil current. Motor current measured for one phase with max. current settings (100% e.g. “SAP 6, 0, 255”) and 256 microsteps: CH1 (yellow): motor current [50mV / A] Motor current setting in software (TMC) In TMCL axis parameter 6 (motor run current) and 7 (motor standby current) can be used for motor current setting: SAP 6, 0, // set run current SAP 7, 0, // set standby current For numbers between 0 (minimum) and 255 (maximum) are supported. Motor current is scaled linearly up-to 0.7A RMS / 1A peak. (read-out value with GAP instead of SAP. Please see separate TMCM-6210 / TMCM-6211 firmware / software manual for further information) Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 24 7 On Board LEDs There are a number of LEDs on-board indicating status. 7.1 Power supply brick With the TMCM-6210 and TMCM-6211 two LEDs are available on the power supply brick part. +5V supply +5V auxilliary supply Figure 7.1: LEDs on power supply brick LED Description +5V supply +5V available from on-board DC/DC converter for supply of on-board digital circuit +5V auxiliary supply +5V auxiliary supply available (can be switched on/off in software). +5V_OUT on REF/HOME and ENCODER connector. 7.2 TMCM-6210 Interface Brick With the TMCM-6210 there are two LEDs (one green and one red) available. Both are connected to the on-board microcontroller and function is firmware dependent. With TMCL firmware the green LED is flashing slowly during operation. During firmware updates both LEDs are switched on. LED (red) LED (green) Figure 7.2: LEDs on TMCM-6210 interface brick Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 25 7.3 TMCM-6211 Interface Brick With the TMCM-6211 there are five LEDs available. Two LEDs are connected to the processor and three to the EtherCAT™ slave controller (ESC). In addition, one LED (ERROR) is connected to both, the microcontroller and the ESC. EtherCAT LINK IN EtherCAT LINK OUT EtherCAT RUN ERROR LED (green) Figure 7.3: LEDs on TMCM-6211 interface brick LED Description EtherCAT™ LINK IN Signal LINK IN, connected to ESC EtherCAT™ LINK OUT Signal LINK OUT, connected to ESC EtherCAT RUN Indicating status of EtherCAT state machine, connected to ESC ERROR Connected to microcontroller and ESC – indicating Error LED (green) Connected to microcontroller – flashing slowly during normal operation 8 Reset to Factory Default For reset to factory default values please follow instructions below: 1. 2. 3. 4. 5. Switch OFF power supply. Short two pads of programming connector pad-array (see figure 8.1). Switch ON power supply (on-board LED should be flashing fast / faster than during normal operation). Switch OFF power supply. Remove short circuit. Figure 8.1 Reset to factory defaults (bottom view of pcb – interface brick end) Copyright © 2015, 2016, 2017 TRINAMIC Motion Control GmbH & Co. KG TMCM-6210, TMCM-6211 Hardware Manual (V0.95 / 2017-MAR-01) 26 9 Operational ratings The operational ratings show the intended or the characteristic ranges and should be used as design values. In no case shall the maximum values be exceeded. Symbol Parameter Min Typ Max Unit +24V Power supply voltage input 10 24 27 V +24V_LOGIC Power supply voltage for on-board digital / logic (if supplied separately) Same as +24V supply input IPEAK Motor coil current for sine wave peak (chopper regulated, adjustable via software) 1 A IRMS Continuous motor current (RMS) 0.7 A I+24V Power supply current for driver TENV Environmental temperature at 6x 0.7A RMS motor current (no forced cooling) V
TMCM-6210-TMCL 价格&库存

很抱歉,暂时无法提供与“TMCM-6210-TMCL”相匹配的价格&库存,您可以联系我们找货

免费人工找货