D E SCR IPTION
T he TMP90 is a series of AC/DC desktop power adapters with 60 to 90 watts of continuous output power. They are enclosed in a 94V-1 rated case with an IEC 320/C14 or C18 inlet for medical and ITE applications. All models meet EN55011, EN55022 and FCC class B emission limits, and are designed for medical applications.
9 0 WATTS MEDICAL POWER ADAPTERS
TMP90 SERIES
( LV D )
RoHS
F EATU R E S
‧ Low safety ground leakage current IEC320/C14 (Class I) or C18 (Class II) Inlet 9 0 t o 2 6 4 VA C w i d e i n p u t r a n g e Optional output connectors O v e r v o l ta g e & o v e r c u r r e n t p r o t e c t i o n s 0.98 PFC 100% burn-in C o m p l i a n t w i t h C E C a n d E n e r g y S ta r e f f i c i e n c y l e v e l I V r e q u i r e m e n ts ( e x c e p t ≤ 1 2 V o u t p u t m o d e l s ) ‧ No load power consumption less than 0.5W ‧ Av e r a g e a c t i v e e f f i c i e n c y ≥ 8 5 % ‧ C o m p l i a n t w i t h R o H S r e q u i r e m e n ts ‧ ‧ ‧ ‧ ‧ ‧ ‧
S af et y Sta n da rd A ppr o va ls :
U L 60601-1 CSA C22.2 No. 601.1 T ÜV EN60601-1
I N PUT S PE C IF ICAT ION S
I n p u t v o l ta g e : Input frequency : Input current : Earth leakage current : 90 to 264VAC 47 to 63Hz 1.20A (rms) for 115VAC 0.60A (rms) for 230VAC 90µA max. @ 115VAC, 60Hz 150µA max. @ 230VAC, 50Hz
G ENERAL SPECIFICATIONS
S witching frequency: 50 KHz - 110 KHz P ower factor : 0 .98 Typical E fficiency : 8 5% min. (78% min. for TMP90-05, TMP90-06, TMP90-09 and TMP90-12) H old-up time : 1 5 msec minimum at 110VAC L ine regulation : ± 0.5% maximum at full load I nrush current : 4 0 amps @ 115VAC or 60 amps @ 230VAC, @ 25ºC cold start W ithstand voltage : 4 000VAC from input to output 1500VAC from input to ground 500VAC from output to ground M TBF : 1 50,000 hours minimum at full load at 25ºC a mbient, calculated per MIL-HDBK-217F E MC Performance (IEC60601-1-2: 2001) E N 5 5 0 11 : FCC: VCCI: EN61000-3-2: EN61000-3-3: EN61000-4-2: EN61000-4-3: EN61000-4-4: EN61000-4-5: EN61000-4-6: EN61000-4-8: E N 6 1 0 0 0 - 4 - 11 : C lass B conducted, Class B radiated C lass B conducted, Class B radiated C lass B conducted, Class B radiated H armonic distortion, Class A and D L ine flicker E SD, ±8KV air and ±6KV contact R adiated immunity, 3V/m F ast transient/burst, ±2KV S urge, ±1KV diff, ±2KV com. C onducted immunity, 3Vrms M agnetic field immunity, 3A/m Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms
O UTPUT SPECIFICATIONS
O utput voltage/current : Total output power : R ipple and noise : O ver voltage protection : O ver current protection : Temperature coefficient : Transient response : S ee rating chart S ee rating chart 2 % peak to peak maximum S et at 112-140% of its nominal output voltage P rotected to short circuit conditions ± 0.04%/ºC maximum M aximum excursion of 4% or better on all models, recovering to 1% of final value within 500µs after a 25% step load change
E N V IR O N M ENTA L SP E C IF ICATI O N S
Operating temperature: Storage temperature: Relative humidity: Derating: 0 ºC t o + 6 0 ºC - 4 0 ºC t o + 8 5 ºC 5% to 95% non-condensing Derate from 100% at +40ºC linearly to 50% at +60ºC
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com
MEDICAL GRADE
OUTPUT VOLTAGE/CURRENT RATING CHART
Output Product No. TMP90-05 TMP90-06 TMP90-09 TMP90-12 TMP90-13.5 TMP90-15 TMP90-18 TMP90-19 TMP90-24 TMP90-30 TMP90-48 Vnom. 5V 6V 9V 12V 13.5V 15V 18V 19V 24V 30V 48V Imin. 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A Imax. 12.0A 10.0A 7.78A 6.67A 6.3A 5.67A 5.0A 4.74A 3.75A 3.0A 1.87A
TMP90 SERIES
Tol. 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% Maximum Output Power 60W 60W 70W 80W 85W 85W 90W 90W 90W 90W 90W
NOTES: 1. Ripple and noise: Peak-to–peak with 20MHz bandwidth and 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor at rated line voltage and load ranges. 2. To order a model with IEC320/C18 inlet with class II insulation, add suffix “C2” , e.g. TMP90-12-C2.
MECHANICAL SPECIFICATIONS
N OTES: 1. Dimensions show in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Weight: 658 grams approx. 4. Standard output connector is a male 4-pin power DIN. Please contact TRUMPower for other connector options. 5. TMP90-05 and TMP90-06 output connectors are without lock.
P IN CHART
P IN Product No. TMP90-05 TMP90-09 TMP90-13.5 TMP90-18 TMP90-24 TMP90-48 TMP90-06 TMP90-12 TMP90-15 TMP90-19 TMP90-30 1 2 3 4 Shell
RETURN
OUTPUT +V
RETURN
OUTPUT +V
AC Ground
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com