F R201 T HRU F R207
2 .0 AMPS. Fast Recovery Rectifiers
V oltage Range 5 0 to 1000 Volts C urrent 2 .0 Amperes
F eatures
L ow forward voltage drop H igh current capability H igh reliability H igh surge current capability
D O-15
M echanical Data
C ases: Molded plastic E poxy: UL 94V-0 rate flame retardant L ead: Axial leads, solderable per MILSTD-202, Method 208 guaranteed P olarity: Color band denotes cathode end H igh temperature soldering guaranteed: 2 60 ℃ /10 seconds/.375”,(9.5mm) lead lengths at 5 lbs.,(2.3kg) tension W eight: 0.40 gram
D imensions in inches and (millimeters)
M aximum Ratings and Electrical Characteristics
R ating at 25 ℃ ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20% S ymbol F R FR T ype Number 2 01 2 02 M aximum Recurrent Peak Reverse Voltage 5 0 1 00 V RRM M aximum RMS Voltage 35 70 V RMS M aximum DC Blocking Voltage 5 0 1 00 V DC
M aximum Average Forward Rectified Current.375”(9.5mm) Lead Length @T A = 5 5 ℃ P eak Forward Surge Current, 8.3 ms Single Half Sine-wave Superimposed on Rated Load (JEDEC method ) M aximum Instantaneous Forward Voltage @ 2.0A M aximum DC Reverse Current @ T A=25 ℃ a t Rated DC Blocking Voltage @ T A=100 ℃ M aximum Reverse Recovery Time ( Note 1 ) T ypical Junction Capacitance ( Note 2 ) T ypical Thermal Resistance ( Note 3 )
FR 2 03
FR 2 04
FR 2 05
FR 2 06
FR 2 07
U nits V V V A A V uA uA nS pF
O
2 00 1 40 2 00
4 00 2 80 4 00 2 .0 60 1 .2 5 .0 100
6 00 4 20 6 00
8 00 1 000 5 60 7 00 8 00 1 000
I(AV) IFSM VF IR T rr Cj R θ JA R θ JL R θ JC TJ
1 50
O perating Temperature Range S torage Temperature Range
T STG N otes:1. Reverse Recovery Test Conditions: IF=0.5A, IR=1.0A, IRR=0.25A 2 . Measured at 1 MHz and Applied Reverse Voltage of 4.0 Volts D.C. 3 . Mount on Cu-Pad Size 10mm x 10mm on P.C.B.
250 30 60 18 5 -65 to +150 -65 to +150
5 00
C/W
℃ ℃
- 406 -
RATINGS AND CHARACTERISTIC CURVES (FR201 THRU FR207)
FIG.1- MAXIMUM FORWARD CURRENT DERATING CURVE
AVERAGE FORWARD CURRENT AMPERES
2.0 70
FIG.2- MAXIMUM NON-REPETITIVE PEAK FORWARD SURGE CURRENT
PEAK FORWARD SURGE CURRENT. (A)
60
1.5
50 40 30 20 10 0
8.3ms Single Half Sine Wave JEDEC Method
1.0
.5
Single Phase Half Wave 60Hz Resistive or Inductive Load 0.375"(9.5mm) Lead Length
0 25 50 75 100
o
0 125 150 175 AMBIENT TEMPERATURE. ( C)
1
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.3- TYPICAL FORWARD CHARACTERISTICS
20 10 100
FIG.4- TYPICAL JUNCTION CAPACITANCE
JUNCTION CAPACITANCE.(pF)
INSTANTANEOUS FORWARD CURRENT. (A)
60
3.0
40
1.0
Tj=25 0C
20
0.3
0.1
Tj=25oC Pulse Width=300 s 1% Duty Cycle
10 1 2 4 6 10 20 40 60 100 REVERSE VOLTAGE. (V)
.03
.01 .4 .6 .8 1.0 1.2 1.4 1.6 1.8 FORWARD VOLTAGE. (V)
FIG.5- REVERSE RECOVERY TIME CHARACTERISTIC AND TEST CIRCUIT DIAGRAM
50W NONINDUCTIVE 10W NONINDUCTIVE +0.5A (-) DUT (+) 50Vdc (approx) (-) PULSE GENERATOR (NOTE 2) 1W NON INDUCTIVE OSCILLOSCOPE (NOTE 1) (+) 0 -0.25A trr
NOTES: 1. Rise Time=7ns max. Input Impedance= 1 megohm 22pf 2. Rise Time=10ns max. Sourse Impedance= 50 ohms
-1.0A 1cm SET TIME BASE FOR 5/ 10ns/ cm
- 407 -
很抱歉,暂时无法提供与“FR202”相匹配的价格&库存,您可以联系我们找货
免费人工找货