• • • • • • 5X7 Surface Mount Package Re ow Process Compatible ACMOS, TTL, LVPECL and LVDS MIL-PRF-55310 Class B Screening (optional) Frequency Range: 1 MHZ to 800 MHZ Previous Model: C1250 • • • •
Applications
Military Systems Avionics and Instrumentation Test Equipment Medical Equipment
Performance Speci cations
Parameter
vs. operating temperature range (referenced to +25°C)
Min
-15 -25 -50 -100 -25 -50 -100 -65 -100 -15 -25 -50 -100 -25 -50 -100 -50 -100 -80 -100 -2 -1 -3 -1
Typ
Max
+15 +25 +50 +100 +25 +50 +100 +65 +100 +15 +25 +50 +100 +25 +50 +100 +50 +100 +80 +100 +2 +1 +3 +1
Units
1
Condition
0… +70°C 0… +70°C 0… +70°C 0… +70°C -40… +85°C -40… +85°C -40… +85°C -55… +125°C (custom number required) -55… +125°C @+25°C @+25°C @+25°C @+25°C 0… +70°C 0… +70°C 0… +70°C -40… +85°C -40… +85°C -55… +125°C -55… +125°C VS ± 5% Load ± 5% after 30 days of operation
Frequency Stabilities
ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm
Initial tolerance
Overall tolerance (Referenced to +25°C) (includes operating temperature and initial accuracy) vs. supply voltage change vs. load change vs. aging / 1 year vs. aging / year (following years)
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Performance Speci cations
Parameter
Supply voltage Supply voltage Supply voltage Current consumption (+5 VDC) Current consumption (+3.3 VDC or +2.5 VDC)
Min
4.75 3.135 2.375
Typ
5.0 3.3 2.5
Max
5.25 3.465 2.625 15 20 40 6 8 16 20 75 100
Units
VDC VDC VDC mA mA mA mA mA mA mA mA mA mA
Condition
Supply Voltage (Vs)
ACMOS or TTL 1.0 to 23.9 MHz ACMOS or TTL 24 to 49.9 MHz ACMOS or TTL 50 to 125.00 MHz ACMOS 1.0 to 14.9 MHZ ACMOS 15.0 to 39.9 MHZ ACMOS 40.0 to 59.9 MHZ ACMOS 60.0 to 84.9 MHZ ACMOS 85.0 to 125.0 MHZ LVPECL or LVDS No load 200 MHz
RF Output
Signal Load Signal Level (Vol) 4.5 3.0 2.25 10 6 3 45 40 55 60 TTL 10 0.4 2.4 5 3 45 40 55 60 LVPECL 50 Vs -1.62 Vs1.025 1000 600 45 55 10 0.5 40 ohm VDC VDC ps ps % ps ps ps into Vcc-2V or Thevenin Equivalent -40....+85°C operating temp -40....+85°C operating temp < 100 MHz >= 100 MHz @ 50% Vdd BW = 10Hz to 20 MHz BW = 12KHz to 20 MHz 10,000 Samples - Rising edge pF VDC VDC ns ns % % with Vs=5.0V and 15pF load with Vs=5.0V and 15pF load 1.0 to 23.9 MHz 24.0 to 125 MHz @ 1.4V < 15 MHz @ 1.4V >= 15 MHz 15 ACMOS 50 0.5 0.3 0.25 pF VDC VDC VDC VDC VDC VDC ns ns ns % % with Vs=5.0V and 15pF load with Vs=3.3V and 15pF load with Vs= 2.5V and 15pF load with Vs=5.0V and 15pF load with Vs=3.3V and 15pF load with Vs=2.5V and 15pF load 1.0 to 23.9 MHz 24.0 to 79.9 MHz 80.0 to 125.0 MHz @ 50% Vs< 15 MHz @ 50% Vs=> 15 MHz
Signal Level (Voh) Rise and fall times for ACMOS (measured 10% to 90%) Duty cycle Signal Load Signal Level (Vol) Signal Level (Voh) Rise and fall times for ACMOS (measured 20% to 80%) Duty cycle Signal Load Signal Level (Vol) Signal Level (Voh) Rise and fall times for ACMOS (measured 20% to 80%) Duty cycle Jitter (rms) Period Jitter (pk-pk)
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Parameter
Signal Load Signal Level (Vol) Signal Level (Voh) Di erential Voltage (Vod) Common Mode (O set) Voltage (Vos) Start-up Time Rise \ Fall Time Duty cycle Jitter (rms) Period Jitter (pk-pk)
Min
60
Typ
100 1.2 1.4
Max
LVDS 140
Units
ohm VDC VDC
Condition
Between outputs
240 1.125
330 1.2
460 1.375 10
mVpeak V ms ps % ps ps ps measured @ 20% to 80% of Vod @ 50% of Vod BW = 10Hz to 20 MHz BW = 12KHz to 20 MHz 10,000 Samples - Rising edge
600 45
1000 55 5 1 40
Absolute Maximum Ratings
Supply voltage (Vs) Operable temperature range Storage temperature range -55 -62 7.0 +125 +125 V °C °C with Vs=5.0VDC and 3.3 VDC
Additional Parameters
Screening Vectron Veri cation Class B, MIL-PRF-55310, Rev.D Logic “0“ input = Outputs disabled (Tri-state) Logic “1“ or oating input = Outputs enabled) Logic “0“ or oating input = Outputs enabled Logic “1“ input = Outputs disabled (Tri-state) < 2 grams Handling & processing note Standard (CMOS and LVDS) Standard (LVPECL)
Output Enable
Weight Processing & Packing
Standard Environmentals
Vibration Shock Acceleration Temperature Cycling Thermal Shock Solderability Leak Test (Fine and Gross) MIL-STD-202, Method 204, Condition G (30 G, 10Hz-2000Hz) MIL-STD-202, Method 213, Condition I (100 G, 6ms, Sawtooth) MIL-STD-883, Method 2001, Condition A (5000 G, Y1 Plane) MIL-STD-883, Method 1010, Condition B MIL-STD-883, Method 107, Condition B MIL-STD-202, Method 208 MIL-STD-883, Method 1014, Condition A1 and C1
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Outline Drawing / Enclosure
Type LCC (ACMOS or TTL)
Package Code 0 Height “H” 1.88mm
Pin Connections
1 2 3 4 Enable/Disable or N/C Ground (Case) Output Supply
Type LCC (LVPECL or LVDS)
Package Code 1 Height “H” 1.88mm
Pin Connections
1 2 3 4 5 6 Enable/Disable or N/C Enable/Disable or N/C (custom number required) Ground (Case) Output Complementary Output Supply
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Outline Drawing / Enclosure
J leads are tinned with Alpha Pb/Sn 63/37 solder.
Type J LEAD (ACMOS or TTL)
Package Code 2 Height “H” 3.40 mm 1 2 3 4
Pin Connections
Enable/Disable or N/C Ground (Case) RF Output Supply Voltage
J leads are tinned with Alpha Pb/Sn 63/37 solder.
Pin Connections
1 2 3 4 5 6 Enable/Disable or N/C N/C Ground (Case) RF Output Complementary Output Supply Voltage
Type J LEAD (LVPECL or LVDS)
Package Code 3 Height “H” 3.40 mm
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Ordering Information
PX - 700 0 - D A T - F K X B - 10M0000000
Frequency Product Family PX: PXO Package 5 x 7 mm Package Code 0: 4 pad LCC 1: 6 pad LCC 2: 4 J Lead 3: 6 J Lead Supply Voltage D: 5 Vdc E: 3.3 Vdc H: 2.5 Vdc RF Output Code A: ACMOS B: TTL C: LVPECL D: LVDS Temperature Range C: -55°C to +125°C E: -40°C to +85°C T: 0°C to +70°C Screening Option B: “B” Level screening X: No Screening Enable Code A: Enable Hi, Tristate C: Enable Lo, Tristate X: No Enable Temp. Stability Code D: ±15ppm F: ±25ppm K: ±50ppm S: ±100ppm X: Use with Overall Tolerance Code Accuracy Code OR Overall Tolerance (Pullability) Code D: ±15ppm F: ±25ppm K: ±50ppm P: ±80ppm S: ±100ppm
Notes: 1. Contact factory for improved stabilities or additional product options. Not all options and codes are available at all frequencies. 2. Unless other stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25°C). 3. Phase noise degrades with increasing output frequency. 4. Subject to technical modi cation. 5. Contact factory for availability.
For Additional Information, Please Contact
USA:
Vectron International 267 Lowell Road Hudson, NH 03051 Tel: 1.888.328.7661 Fax: 1.888.329.8328
Europe:
Vectron International Landstrasse, D-74924 Neckarbischofsheim, Germany Tel: +49 (0) 3328.4784.17 Fax: +49 (0) 3328.4784.30
Asia:
Vectron International 1F-2F, No 8 Workshop, No 308 Fenju Road WaiGaoQiao Free Trade Zone Pudong, Shanghai, China 200131 Tel: 86.21.5048.0777 Fax: 86.21.5048.1881
Disclaimer
Vectron International reserves the right to make changes to the product(s) and or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Rev: 6/19/2009 DAB Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com