VCB1 series 3.3, 5.0 volt CMOS Oscillator Features • CMOS output • Output frequencies to 160 MHz • Tri-state output for board test and debug • 0/70 or –40/85 °C operating temperature • Product is compliant to RoHS directive and fully compatible with lead free assembly Applications The VCB1 Crystal Oscillator • SONET/SDH/DWDM • Ethernet, Gigabit Ethernet • Storage Area Network • Digital Video • Broadband Access • Microprocessors/DSP/FPGA Description fo Output Buffer / Disable Vectron’s VCB1 Crystal Oscillator (XO) is quartz stabilized square wave generator with a CMOS output, operating off a 3.3 or 5.0 volt supply. The VCB1 uses fundamental or 3 overtone crystals, for output frequencies < 80MHz, resulting in low jitter performance, typically 0.5ps rms in the 12 kHz to 20MHz band. rd Vectron International 267 Lowell Road, Hudson NH 03051 Tel: 1-88-VECTRON-1 e-mail: vectron@vectron.com Performance Characteristics Table 1. Electrical Performance, 5V option Parameter Symbol Frequency fO 1 Operating Supply Voltage VDD Absolute Maximum Supply Voltage IDD Supply Current, Output Enabled 0.032768 to 2.0 MHz 2.01 to 30 MHz 30.01 to 50 MHz 50.01 to 160.00 MHz Output Logic Levels 2 Output Logic High VOH 2 Output Logic Low VOL Output Rise/Fall Time 0.032768 to 2.00 MHz 2.01 to 20.00 MHz 20.01 to 160.00 MHz 3 Duty Cycle (ordering option) Operating Temperature (ordering option) Storage Temperature 4 Stability (ordering option) 5 Output Enable/Disable Output Enabled Output Disabled Start-up time 2 Min 0.032768 4.5 -0.7 Typical 5.0 Maximum 160.000 5.5 7.0 10 15 40 50 Units MHz V V mA 0.9*VDD 0.1*VDD 10 8 5 V V ns tR/tF SYM 40/60 or 45/55 0/70 or -40/85 -55 125 ±20, ±25, ±32, ±50, ±100 4.0 0.8 10 % °C °C ppm V ms 1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended. 2. Figure 1 defines these parameters. Figure 2 illustrates the operating conditions under which these parameters are tested and specified. 3. Symmetry is measured defined as On Time/Period. 4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration (not under operation). 5. Output will be enabled if enable/disable is left open. tR tF IDD 4 V DD V OH 50% V OL On Time Period + - .1 µF . 01 µF IC VC 1 + - 2 3 1 5pF Figure 1. Output Waveform Figure 2. Typical Output Test Conditions (25±5°C) Vectron International 267 Lowell Rd, Hudson NH 03051 Tel: 1-88-VECTRON-1 e-mail: vectron@vectron.com VCB1 Data Sheet Table 2. Electrical Performance, 3.3V option Parameter Symbol Frequency fO 1 Operating Supply Voltage VDD Absolute Maximum Operating Voltage IDD Supply Current, Output Enabled 0.032786 to 2.0 MHz 2.01 to 30 MHz 30.01 to 50 MHz 50.01 to 160 MHz Output Logic Levels 2 Output Logic High VOH 2 Output Logic Low VOL 2 tR/tF Output Rise/Fall Time 0.032768 to 2.00 MHz 2.01 to 20.00 MHz 20.01 to 160.00 MHz 3 Duty Cycle (ordering option) SYM Operating Temperature (ordering option) Storage Temperature 4 Stability (ordering option) 5 Output Enable/Disable Output Enabled Output Disabled Start-up time Min 0.032768 2.97 -0.5 Typical 3.3 Maximum 160.000 3.63 5.0 8 10 20 35 Units MHz V V mA 0.9*VDD 0.1*VDD 12 10 6 40/60 or 45/55 0/70 or –40/85 -55 125 ±20, ±25, ±32, ±50, ±100 2.0 0.5 10 V V ns % °C °C ppm V ms 1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended. 2. Figure 3 defines these parameters. Figure 4 illustrates the operating conditions under which these parameters are tested and specified. For Fo>90MHz, rise and fall time is measured 20 to 80%. 3. Symmetry is measured defined as On Time/Period. 4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration (not under operation). 5. Output will be enabled if enable/disable is left open. tR tF IDD 4 V DD V OH 50% V OL On Time Period + - .1 µF . 01 µF IC VC 1 + - 2 3 1 5pF Figure 3. Output Waveform Figure 4. Typical Output Test Conditions (25±5°C) Vectron International 267 Lowell Rd, Hudson NH 03051 Tel: 1-88-VECTRON-1 e-mail vectron@vectron.com VCB1 Data Sheet Enable/Disable Functional Description Under normal operation the Enable/Disable is left open or set to a logic high state. When the E/D is set to a logic low, the oscillator stops and the output is in a high impedance state. This helps reduce power consumption as well as facilitating board testing and troubleshooting. Tri-state Functional Description Under normal operation the tri-state is left open or set to a logic high state. When the tri-state is set to a logic low, the oscillator remains active but the output buffer is in a high impedance state. This helps facilitate board testing and troubleshooting. Table 3. Outline Diagrams and Pin Out Pin # 1 2 3 4 Symbol E/D or NC GND fO VDD Function Tri-state, Enable/Disable or NC Electrical and Case Ground Output Frequency Supply Voltage Figure 5, Package drawing Vectron International 267 Lowell Rd, Hudson NH 03051 Tel: 1-88-VECTRON-1 e-mail vectron@vectron.com VCB1 Data Sheet Reliability The VCB1 qualification tests have included: Table 4. Environnemental Compliance Parameter Mechanical Shock Mechanical Vibration Temperature Cycle Gross and Fine Leak Resistance to Solvents MIL-STD-883 MIL-STD-883 MIL-STD-883 MIL-STD-883 MIL-STD-883 Conditions Method 2022 Method 2007 Method 1010 Method 1014 Method 2015 Handling Precautions Although ESD protection circuitry has been designed into the the VCB1, proper precautions should be taken when handling and mounting. VI employs a Human Body Model and a Charged-Device Model (CDM) for ESD susceptibility testing and design protection evaluation. ESD thresholds are dependent on the circuit parameters used to define the model. Although no industry wide standard has been adopted for the CDM, a standard HBM of resistance = 1.5kohms and capacitance = 100pF is widely used and therefore can be used for comparison purposes. Table 5. ESD Ratings Model Human Body Model Charged Device Model Minimum 1000 1500 Conditions MIL-STD-883 Method 3115 JESD 22-C101 Suggested IR profile Devices are built using lead free epoxy and can also be subjected to standard lead free IR reflow conditions, Table 6 shows max temperatures and lower temperatures. A peak temperature of 240°C minimum should be used to reflow the lead solder. Table 6. Reflow Profile (IPC/JEDEC J-STD-020B) Parameter Symbol Preheat Time Ramp Up Time Above 217 C Time To Peak Temperature Time At 260 oC (max) Time At 240 °C (max) Ramp Down o Value 150 sec Min, 200 sec Max 3 oC/sec Max 60 sec Min, 150 sec Max 480 sec Max 10 sec Max 60 sec Max 6 oC/sec Max tS R UP tL t AMB-P tP tp2 R DN Vectron International 267 Lowell Rd, Hudson NH 03051 Tel: 1-88-VECTRON-1 e-mail vectron@vectron.com VCB1 Data Sheet Ordering Information: VCB1 Product Family Crystal Oscillator ½ Size DIP Voltage Options A: +5.0 Vdc +/-10%, 15pF B: +3.3 Vdc +/-10%, 15pF C: +3.0 Vdc +/-5%, 15pF E: +5.0 Vdc +/-10%, 50pF F: +3.3Vdc +/-5%, 50pF B 3 B- 25M00 Output Frequency In MHZ Electrical Options 3: Tri-state, 45/55% Duty The following codes are not recommended for new designs 0: No tri-state, 40/60% Duty 1: Tri-state, 40/60% Duty 2: No tri-state, 45/55%Duty 5: Enable, 40/60% Duty 6: Enable, 45/55% Duty Stability Options A: ±100ppm, 0 to 70°C C: ±100ppm, -40 to 85°C B: ±50ppm, 0 to 70°C D: ±50ppm, -40 to 85°C E: ±25ppm, 0 to 70°C F: ±25ppm, -40 to 85°C G: ±20ppm, 0 to 70°C Note: Not all combinations are available. Tri-state with a 45/55% is the most common Electrical code and is recommended for most applications. Devices will be shipped in Anti Static Tubes For Additional Information, Please Contact: USA: Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON E UROPE: L andstrasse, D-74924, Neckarbischofsheim, Germany • Tel: 49 (0) 7268 8010 • Fax: 49 (0) 7268 801281 ASIA: Vectron Asia Pacific Sales 1F~2F. No.8 Workshop No.308 Fenju Rd., WaiGaoQiao Free Trade Zone, Pudong New Area Shanghai, China 200131 •Tel: 8621 50480777 • Fax: 8621 50481881 June23, 2006 www.vectron.com Vectron International 267 Lowell Rd, Hudson NH 03051 Tel: 1-88-VECTRON-1 e-mail vectron@vectron.com
VCB1-B3F-25M00
1. 物料型号: - 型号为VCB1,是Vectron International公司生产的Crystal Oscillator(晶体振荡器)。

2. 器件简介: - VCB1系列是一款3.3V或5.0V供电的CMOS输出晶体振荡器,输出频率可达到160MHz。它使用基本模式或第三泛音晶体,以实现低于80MHz的输出频率,从而获得低抖动性能,典型值为12kHz至20MHz频带内0.5ps的均方根值。

3. 引脚分配: - Pin#1:E/D或NC(三态,使能/禁用或无连接) - Pin#2:GND(电气和机箱地) - Pin#3:fo(输出频率) - Pin#4:VDD(供电电压)

4. 参数特性: - 频率范围:0.032768MHz至160.000MHz - 工作供电电压:3.3V或5V选项,典型值为5.0V - 绝对最大供电电压:-0.7V至7.0V - 供电电流:在不同频率下有不同的典型值,从10μA至50μA不等 - 输出逻辑电平:高电平为0.9VDD,低电平为0.1VDD - 输出上升/下降时间:在不同频率下有不同的典型值,从10ns至8ns不等 - 占空比:可定制为40/60%或45/55%

5. 功能详解: - 该振荡器具有CMOS输出,支持高达160MHz的输出频率,具有三态输出功能,便于板级测试和调试。支持0/70°C或-40/85°C的工作温度范围,并且符合RoHS指令,完全兼容无铅装配。

6. 应用信息: - 应用于SONET/SDH/DWDM、以太网、千兆以太网、存储区域网络、数字视频、宽带接入以及微处理器/DSP/FPGA等领域。